Common Laboratory Equipment
Filter
Showing 3721–3750 of 4952 results
| Brand | New Biolink |
|---|---|
| Model | UHP-RO Series |
| Max Operating Pressure | 20 MPa |
| Membrane Type | High-Pressure Tolerant RO Element with Open-Channel Feed Spacer |
| Feed Compatibility | High-Salinity Wastewater (TDS up to 120,000 mg/L) |
| Recovery Rate | ≥75% (system-dependent) |
| Origin | Beijing, China |
| Application | Laboratory-Scale Wastewater Concentration and Brine Minimization |
| Brand | ADVANTEC (Yan Hua Dong Yang) |
|---|---|
| Origin | Japan |
| Model | 10-905 |
| Type | Manual Date/Number Embossing Punch |
| Max. Sheet Capacity | 10 sheets (64 g/m² paper, 8-digit imprint) |
| Cycle Time | 1.5 s/cycle (50 Hz) / 1.2 s/cycle (60 Hz) |
| Dimensions | 214 × 295 × 485 mm |
| Weight | 12.7 kg |
| Die Block Compatibility | MOLE 905-208 |
| Power Supply | None (Manual Operation) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet Air |
| Volume Range Options | 0.1–2 µL (Gray), 0.5–10 µL (Pink), 2–20 µL (Beige), 10–100 µL (Orange), 20–200 µL (Yellow), 100–1000 µL (Blue), 500–5000 µL (Green), 1000–10000 µL (White) |
| Increment Resolution | 0.002–10 µL (model-dependent) |
| Operating Principle | Air-displacement positive displacement hybrid mechanism with low-force plunger actuation |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet FII & VII |
| Type | Manual Single-Channel Adjustable-Volume Pipette |
| Volume Range | 10–1000 µL |
| Accuracy | ±0.5% to ±1.2% (varies by volume) |
| Coefficient of Variation (CV) | ≤0.2% to ≤0.6% (volume-dependent) |
| Tip Compatibility | BMT2-series and F-series sterile filtered tips (e.g., BMT2-SG, FSGRB, BMT2-LE, FLERB) |
| Operating Principle | Air-displacement positive displacement (FII: fixed-volume |
| VII | triple presettable volumes) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | ACCUPENSER JR |
| Instrument Type | Manual Adjustable Bottle-top Dispenser |
| Automation Level | Manual |
| Volume Range Options | 0.2–10 mL (AJ-1), 0.4–20 mL (AJ-2), 1–50 mL (AJ-5), 2–100 mL (AJ-10) |
| Minimum Increment | 0.05 mL (AJ-1), 0.1 mL (AJ-2 & AJ-5), 0.25 mL (AJ-10) |
| Coefficient of Variation (CV) | ≤0.1% |
| Bottle Compatibility | Standard 500 mL and 1 L reagent bottles (neck dimensions identical) |
| Bottle Dimensions (W × H, mm) | 75 × 210 (165), 100 × 210 (165), 146 × 210 (165) — values in parentheses indicate collapsed height when vernier head is folded |
| Materials in Contact with Liquids | Chemically resistant polymers |
| Sterilization | Autoclavable at 121°C for 20 minutes |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Custom-Made Pipettes |
| Instrument Type | Single-Channel Manual Pipette |
| Automation Level | Manual |
| Channel Count | Single |
| Volume Range | Custom-Defined (Typically 0.1–10,000 µL) |
| Accuracy & Precision | Compliant with ISO 8655 (per customer-specified calibration range) |
| Regulatory Compliance | Designed to support GLP/GMP workflows and FDA 21 CFR Part 11–aligned documentation protocols |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Dispet Ex |
| Dispensing Range | 0.2–10 mL (DP-10), 0.4–20 mL (DP-20), 1–5 mL (DP-5), 2–10 mL (DP-10) |
| Minimum Increment | 0.05–0.25 mL |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤0.2% |
| Bottle Compatibility | Ø22 mm (for DP-5/DP-10), up to Ø45 mm (with optional adapters) |
| Adapter Options | DP-1118 (18 mm), DP-1119 (19 mm), DP-1122 (22 mm), DP-1124 (24 mm), DP-1125 (25 mm), DP-1128 (28 mm), DP-1133 (33 mm), DP-1138 (38 mm), DP-1145 (45 mm) |
| Included Accessories | One 220 mm flexible PTFE-lined tubing (user-cuttable) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28, GL-32, GL-45 (bottles sold separately) |
| Liquid Contact Materials | Chemically resistant PTFE, FEP, and ETFE components |
| Design | Handheld, portable, ergonomic manual dispenser |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET EX II |
| Type | Manual Bottle Top Dispenser |
| Volume Range | 0.2–10 mL |
| Minimum Graduation | 0.05 mL |
| Accuracy | ±0.1% of full scale |
| Maximum Permissible Error | ±0.5% of set volume |
| Pressure Resistance | Up to 6 bar |
| Temperature Resistance | Up to 120 °C |
| Material Compatibility | Chemically resistant PTFE, FFKM, and glass-reinforced PPS components |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | DISPET Mini |
| Dispensing Volumes | 100–250 mL (±2.0%), 500–1000 mL (±1.0%), 1000–2000 mL (±1.0%) |
| Coefficient of Variation (CV) | ≤0.4% (100–250 mL), ≤0.2% (500–2000 mL) |
| Bottle Neck Compatibility | GL-28 standard thread |
| Liquid Contact Materials | Chemically resistant PTFE, ETFE, and FEP components |
| Regulatory Compliance | Designed for ISO 8655-compliant volumetric dispensing procedures |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL2100DG |
| Type | Manual Multi-Channel Continuous Dispenser |
| Dispensing Range Options | 0.2–1.0 mL (00-21DG-1), 0.4–2.0 mL (00-21DG-2), 1.0–5.0 mL (00-21DG-5), 2.0–10.0 mL (00-21DG-10) |
| Minimum Increment | 0.01–0.10 mL depending on model |
| Display Resolution | 0.01 mL (DG-1/DG-2), 0.02 mL (DG-5), 0.10 mL (DG-10) |
| Fluid Contact Materials | PTFE, Tygon® tubing, polypropylene, Pyrex® glass, ceramic, platinum-iridium alloy |
| Housing | Impact-resistant polymer shell protecting internal glass and piston components |
| Ergonomics | Single-hand operation, lightweight design (<300 g) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL3100 |
| Pipette Type | Manual Multi-Channel Pipette |
| Volume Range Options | 0.2–1.0 mL, 0.4–2.0 mL, 1.0–5.0 mL, 2.0–10.0 mL |
| Minimum Increment | 0.1 mL (for 0.2–1.0 & 0.4–2.0 mL ranges), 0.5 mL (for 1.0–5.0 & 2.0–10.0 mL ranges) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Tip Compatibility | Nichiryo Standard Clear Tips (00-MPT-1, 00-MPT-2, 00-BMT2-X, 00-BMT2-Z) |
| Piston Material | PTFE-Coated Stainless Steel |
| Tip Packaging | 1000 or 2000 per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL5100 |
| Pipette Type | Single-Channel Manual Pipette |
| Adjustable Volume Range | 15–25 mL and 30–50 mL (via interchangeable volume adjustment tubes) |
| Accuracy | ±1.0% |
| Coefficient of Variation (CV) | ≤1.0% |
| Compatible Tip Type | Nichiryo TL50 Series (e.g., 00-51TL50) |
| Tip Packaging | 50 pcs per pack |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8100 |
| Type | Motorized Multi-Step Electronic Dispenser |
| Sample Volume Range | 1 µL – 5 mL (configurable via 7 interchangeable syringe barrels) |
| Accuracy | ±0.8% to ±2.5% (volume-dependent) |
| Precision (CV) | ≤0.3% to ≤4.0% (volume-dependent) |
| Max. Dispensing Cycles per Fill | 10–58 (barrel-dependent) |
| Sterilization | Autoclavable at 121 °C for 20 min (all barrels except 3.0 mL and 60 mL) |
| Syringe Tip Length | 50 mm |
| Materials | PP (standard), PE (N3 and Z barrels) |
| Drive Mechanism | Pulse-driven positive displacement |
| Compliance | Designed for GLP-compliant liquid handling workflows |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | MODEL8800 |
| Instrument Type | Multi-Channel Manual Continuous Dispenser |
| Number of Channels | 8 |
| Operating Range | 10–100 µL (6 preset volumes: 10, 20, 25, 40, 50, 100 µL) |
| Accuracy | ±2.0% (at specified volumes) |
| Coefficient of Variation (CV) | ≤1.2% |
| Syringe Options | A (520 µL), B (1300 µL) |
| Max. Sequential Dispensing Cycles | 50 (at 10 µL), 25 (at 20/25 µL), 12 (at 40/50/100 µL) |
| Dimensions (with syringes installed) | 285 × 82 × 23 mm |
| Sterilization Compatibility | Autoclavable at 121°C for 20 min |
| Actuation | Manual lever-driven continuous dispensing |
| Brand | AS ONE (Nichiryo) |
|---|---|
| Origin | Japan |
| Manufacturer | Nichiryo Co., Ltd. |
| Model | 00-NSTP (equivalent to AS ONE catalog no. 2-5001-01) |
| Dispensing Range | 1–5000 µL |
| Dispense Increment | 1 µL |
| Drive Type | Motorized (Electric) |
| Channel Configuration | Single-Channel |
| Compliance | CE-marked, ISO 8655-compliant design principles |
| Calibration | Factory-calibrated per ISO 8655-6 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NPLO2 |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.5 µL – 50 mL (via interchangeable syringe barrels) |
| Accuracy | ±0.3% to ±5% (volume-dependent) |
| Precision (CV) | <0.2% to <8.0% (volume-dependent) |
| Sterilizable Options | Yes (selected syringe barrels) |
| Compatible Tips | BMT-UT tips (NS-V), NS-ASP adapters (NS-Y/Z), Eppendorf 4780-compatible syringes |
| Syringe Material | Polypropylene (barrel), Polyethylene (plunger) |
| Max Sequential Dispensing Cycles | 48 |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet ECO |
| Pipette Type | Single-channel Manual Pipette |
| Volume Range | 20 µL – 10 mL |
| Maximum Capacity | 10 mL |
| Accuracy | ±3.0% to ±6.0% |
| Precision (CV) | ≤3.0% to ≤6.0% |
| Tip Compatibility | Nichiryo Glass Tips (S, L, X, Z series) |
| Operating Principle | Air-displacement with ceramic piston and PTFE-coated tip cone |
| Sealing | Dual O-ring tip ejection mechanism |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | EX II MULTI |
| Pipette Type | Manual Multi-Channel Pipette |
| Channels | 8 or 12 |
| Volume Range Options | 0.5–10 µL (V), 5–100 µL (S), 20–200 µL (L), 30–300 µL (K) |
| Minimum Increment | 0.01 µL (V), 0.1 µL (S), 0.2 µL (L), 1 µL (K) |
| Sterilization | Full-unit autoclavable at 121°C for 20 min |
| Tip Compatibility | BMT2-UT/UTWR/UTWRB, FUT/FUTRB, BMT2-SG/SGR/SGRB, FSE/FSERB, FAG/FAGRB, BMT2-K/KR/KRB |
| Material | UV-resistant polymer housing |
| Weight Reduction | ~30% vs. previous generation |
| Ergonomic Design | Rotatable 360° plunger knob, reduced plunger force, serviceable modular construction |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX II |
| Type | Manual Single-Channel Pipette |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Sterilization | Autoclavable at 121°C for 20 min |
| Tip Ejection | Non-contact, plastic ejector mechanism |
| Sealing Material | PTFE in air-tight components |
| Piston Material | Ceramic (for ≥200 µL models) |
| Filter Tip Compatibility | Integrated filter sleeve (≥1000 µL models) |
| Volume Adjustment | Digital dial with lockable knob |
| Minimum Increment | 0.002–10 µL (model-dependent) |
| Tip Compatibility | BMT2-series tips (UT, SS, SG, LE, X, Z) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Nichipet EX Plus II |
| Pipette Type | Manual Single-Channel |
| Volume Range | 0.1–10,000 µL |
| Maximum Capacity | 10 mL |
| Accuracy | ±2.0% |
| Tip Compatibility | BMT2-series (UT, SS, SE, L, X, Z) |
| Sterilization | Autoclavable (121°C, 20 min) & UV-Capable |
| Calibration | In-lab adjustable via integrated locking dial |
| Piston Material | Ceramic (≥100 µL), Fluoropolymer-coated stainless steel (≤10 µL) |
| O-rings | FKM (fluoroelastomer) |
| Spring | Corrosion-resistant alloy |
| Chemical Resistance | Verified against strong acids, bases, ketones, esters, aldehydes, and inorganic/organic solvents |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | NSS-1000II Basic |
| Type | Benchtop Robotic Liquid Handler |
| Configuration | Standalone or Integrated Platform |
| Programming Interface | C-language or Visual Basic SDK |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Application Scope | Life Sciences, Pharmaceutical R&D, Clinical Diagnostics, Chemical Laboratories |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Model | Pipette Mate NEO |
| Power Source | Rechargeable Lithium-Ion Battery (Charging Time: 4 h |
| Input Voltage | 100–240 V, 50/60 Hz, 0.2 A |
| Filter | Hydrophobic PTFE, 20 mm × 0.2 µm |
| Compatible Pipettes | 1–100 mL glass or plastic serological pipettes |
| Sterilization | Autoclavable at 121 °C for 20 min (liquid-contact components only) |
| Weight | 167 g |
| Certifications | CE, RoHS |
| Operating Environment | Compatible with laminar flow hoods and UV sterilization workflows |
| Ergonomics | Integrated speed control dial, vertical stand-alone design (no support rack required) |
| Brand | Nichiryo |
|---|---|
| Origin | Japan |
| Type | Sterilizable Disposable Pipette Tips |
| Packaging Options | Bulk (1000 pcs) and Rack (96-well or 50-well formats, sterilized or non-sterilized) |
| Volume Range | 0.1–10 µL, 0.5–10 µL, 2–200 µL, 50–300 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL |
| Material | High-purity polypropylene (PP) |
| Sterilization | Autoclavable at 121 °C for 20 minutes |
| DNase/RNase-Free | Yes (except X and Z series) |
| UV-Compatible | Yes |
| Brand | NIL |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NIL-4i |
| Pricing | Contact for Quotation |
| Wafer Size | 4 in |
| Imprintable Area | 2 in diameter |
| Imprint Pressure Range | 0–25 PSI (upgradable to 100 PSI) |
| Mold Substrate Dimensions | 5 × 0.090 in |
| Typical Throughput | < 5 min/wafer |
| Controller Platform Dimensions | 5.8 × 16.5 × 12 in |
| Main Platform Dimensions | 17 × 16 × 15 in |
| Weight (Controller) | 18.5 lb |
| Weight (Main Unit) | 45 lb |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤65% RH |
| Compressed Air Supply | Filtered, 70–100 PSI |
| Vacuum Source | ≤−14 PSI |
| Power Input | 110–220 VAC, 2 A, 50/60 Hz |
| Cleanroom Class | ISO Class 6 (Class 1000) or better |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | General-Purpose Ultrasonic Cleaner |
| Tank Capacity | 30 L |
| Ultrasonic Frequency | 40 kHz (Sweep Mode) |
| Ultrasonic Power Output | 840 W |
| Power Adjustment | Yes (40–99% in 1% increments) |
| Heating Range | Ambient to 80 °C |
| Timer Range | 1–999 min |
| Sound-Dampening Lid | Included |
| Auto Fill/Drain Port | Equipped |
| Frequency Options | Four selectable frequencies with independent time settings per frequency |
| Display | Digital LED showing real-time temperature and remaining time |
| Safety | Power interruption memory function |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manifold Benchtop Freeze Dryer |
| Application Scale | Pilot-Scale |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm + 440 mm (condenser height) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | Scientz-25T |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 2.5 m² |
| Ultimate Vacuum | ≤10 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −85 °C |
| Dimensions (W×D×H) | 2300 × 1200 × 2200 mm |
| Control System | PLC + Touchscreen HMI |
| Data Compliance | FDA 21 CFR Part 11–Ready Audit Trail & Exportable Log Files |
| Refrigeration Technology | Single-Unit Self-Contained Cascade Refrigeration System |
| Valve Actuation | Individual Silicone Rubber Stopper Valves per Flask |
| Optional Accessories | Customizable Flask Racks, Glass Vials, Vacuum Inlet Nozzles, Nitrogen Backfill Valve |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-500C |
| Max Ultrasonic Power | 900 W |
| Ultrasonic Frequency | 22 ± 1 kHz |
| Max Heating Power | 1000 W |
| Temperature Range | 0–99 °C |
| Bath Volume | 6 L |
| Probe Diameter | Φ10 mm |
| Power Adjustment Range | 15–100% |
| Sonication Time Setting | 1–999 min (with pulse mode: on-time 1–99 s, off-time 1–99 s) |
| Cooling Compressor Power | 500 W |
| Temperature Stability | ≤ ±1 °C |
| Brand | Ningbo Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SCIENTZ-IIDM |
| Microwave Power | 1000 W |
| Microwave Frequency | 2450 MHz |
| Temperature Control Range | Ambient to 300 °C |
| Temperature Control Accuracy | ±1 °C |
| Cavity Material | Stainless Steel Interior |