| Brand | Ottescience |
|---|---|
| Origin | Tianjin, China |
| Model | MH-2800D |
| Temperature Range | Ambient +5 °C to 200 °C |
| Temperature Stability | ±0.1 °C |
| Temperature Accuracy | ±0.15 °C |
| Timer Range | 1–999 min |
| Block Capacity | 2 standard blocks or 1 double-size block |
| Heating Power | 400 W @ 220 V / 50 Hz |
| External Dimensions (W×H×D) | 240 × 92 × 215 mm |
| Chamber Dimensions (W×H×D) | 150 × 51 × 95 mm |
| Over-Temperature Protection | 200 °C (hardware limit), +5 °C deviation alarm |
| Brand | Ottesens |
|---|---|
| Origin | Tianjin, China |
| Model | AS3120B |
| Capacity | 10 L (tank volume), 3 L (usable cleaning volume) |
| Ultrasonic Frequency | 40 kHz / 60 kHz dual-frequency selectable |
| Ultrasonic Power Output | 500 W (adjustable from 1% to 100%) |
| Timer Range | 1–999 min (digital control) |
| Lid | Acoustic-dampening hinged cover included |
| Drain | Manual valve |
| Construction | Stainless steel tank, corrosion-resistant aluminum housing |
| Dimensions (W×L×H) | 265 × 160 × 240 mm (external) |
| Power Input | 220 V AC, 50/60 Hz |
| Compliance | CE-marked per EN 61000-6-3 (EMC) and EN 61000-6-2 (immunity) |
| Brand | Ottesens |
|---|---|
| Origin | Tianjin, China |
| Model | MTN-5800 / MTN-5800A |
| Heating Method | Water Bath |
| Temperature Range | Ambient to 96 °C |
| Temperature Stability | ±0.2 °C |
| Tube Diameter Compatibility | 10–29 mm (standard) / 30–55 mm (optional) |
| Gas Flow Rate | 0–25 L/min |
| Sample Positions | 12 or 24 |
| Heating Power | 1000 W |
| Control Type | Manual (MTN-5800) / Motorized Vertical Adjustment (MTN-5800A) |
| Safety Features | Auto water-level cutoff, drain valve, overheat protection |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | FOGBOOSTER |
| Quotation | Available Upon Request |
| Chamber Volume | Not Applicable |
| Heating Power | None |
| Operating Temperature | Ambient (Cold Fogging Only) |
| Disinfectant Type | Anhydrous Formulation (GD-6) |
| External Dimensions (L×W×D) | Not Specified |
| Brand | AIRSENSE |
|---|---|
| Origin | Germany |
| Model | Surf-Ex |
| Certification | ATEX Zone 1 & Zone 21 compliant |
| Decontamination Method | Spray-Extraction with Integrated Vacuum Recovery |
| Max Effective Coverage | 200 cm (80 in) |
| Max Hose Extension Length | 15 m |
| Collection Capacity | Compatible with standard 20–60 L containment drums |
| Pump Type | Explosion-proof diaphragm pump |
| Inlet Diameter | Large-diameter suction port for bulk particulate and sorbent material removal |
| Application Scope | Surface decon of sensitive equipment interiors, aircraft fuselages, ship compartments, infrastructure, and contaminated soil/sorbents |
| Compliance | Meets EU Directive 2014/34/EU (ATEX), IEC 60079-0/-10/-14, and supports GLP-aligned documentation workflows |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Microstat |
| Temperature Range | 1.5 K to 300 K (depending on configuration) |
| Cooling Method | Closed-cycle helium cryocooler or liquid helium flow cryostat |
| Optical Access | Dual windows (UV to FIR transmission, optional AR coatings) |
| Electrical Feedthroughs | Up to 24 low-noise coaxial or twisted-pair leads |
| Footprint | Compact benchtop design (< 300 mm × 300 mm base) |
| Vibration Isolation | Active/passive hybrid stage stabilization |
| Compliance | CE, UKCA, RoHS |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MicrostatHiRes |
| Temperature Range | 2.7 K – 500 K (with optional rotary pump) / 3.4 K – 500 K (standard) |
| Base Temperature Stability | ±0.1 K |
| Helium Consumption at 4.2 K | < 0.70 L/hr (with low-loss transfer line) |
| Cool-down Time from RT to 4.2 K | ~15 min (with pre-cooled transfer line) |
| Working Distance | 2.2 mm |
| Sample Vibration | < 20 nm (measured in SEM environment) |
| Mass | 1.5 kg |
| Controller | Mercury iTC |
| Communication Interfaces | RS232, USB (serial emulation), TCP/IP, GPIB |
| Software Integration | LabVIEW driver library and virtual instrument support |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 13,500 – 40,500 (FOB UK) |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat Dry |
| Price Range | USD 42,000 – 70,000 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry |
| Temperature Range | < 3 K to 300 K |
| Cool-down Time | ≤120 min to 10 K |
| Optical Aperture | Up to 28 mm diameter |
| Numerical Aperture | f/1 |
| Electrical Feedthroughs | Up to 12 leads |
| Cooling Options | Air-cooled or water-cooled cryocooler |
| Vibration Level | < 10 µm (when mounted on optical table) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, compatible with GLP/GMP data integrity requirements |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PlasmaPro 100 Cobra |
| Wafer Capacity | Single-wafer and batch processing up to 200 mm |
| Temperature Range | −150 °C to +400 °C |
| Electrode Cooling/Heating | Liquid nitrogen, recirculating chiller, or resistive heating |
| RF Power Delivery | Top-mounted electrode with dual-frequency (LF/RF) capability |
| ICP Source Options | 65 mm, 180 mm, 300 mm |
| Process Pressure Range | Wide operational window enabled by high-pumping-speed vacuum system |
| Substrate Thickness Compatibility | Up to 10 mm |
| Backside He–cooling | Integrated electrostatic chuck with helium backside cooling |
| Endpoint Detection | Real-time optical emission spectroscopy (OES) monitoring |
| Chamber Architecture | Symmetric, low-inductance plasma chamber with uniform gas distribution and high-conductance pumping path |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox 5 mK |
| Cooling Principle | Helium-3/Helium-4 Dilution Refrigeration |
| Base Temperature | < 5 mK |
| Magnet Compatibility | Integrated or Standalone Oxford Superconducting Magnets (up to 18 T) |
| Cryogenic Architecture | Dry, Helium-Free Operation |
| System Configuration | Turnkey Cryostat with Vibration-Isolated Mixing Chamber and Thermal Anchoring Stages |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox |
| Cooling Principle | Continuous He-3/He-4 Dilution Refrigeration |
| Base Temperature | ≤ 10 mK (typical) |
| Experimental Bore Diameter | 360 mm |
| Secondary Insert Capacity | Up to 2 × ISO100 feedthroughs |
| Additional Feedthroughs | Up to 2 × KF40 + 2 × KF25 |
| Thermal Management | Patented Gas-Gap Heat Switch System |
| Magnet Integration | Fully compatible with Oxford Instruments superconducting magnets |
| Software Platform | Web-based, cross-platform control with audit-trail logging |
| Maintenance Cycle | Extended via automated gas-handling bypass system |
| Sample Exchange | Optional bottom-loading rapid sample transfer mechanism integrated at secondary insert level |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | SpectromagPT |
| Temperature Range | 1.6 K – 300 K |
| Magnetic Field Strength | Up to 7 T |
| Optical Access | Dual-axis (parallel & perpendicular to field) |
| Sample Chamber Diameter | 30 mm |
| Temperature Stability (standard probe) | ±0.1 K |
| Cool-down Time (room temp → 4 K) | ~40 h |
| Probe Cool-down Time (to <2 K, cold insert) | <90 min |
| Field Ramp Time (to max field) | ≤60 min |
| Continuous Operation Duration | >4 weeks |
| Cryocooler Type | Closed-cycle, helium-free |
| Sample Exchange | Top-loading, no lock-in mechanism required |
| Thermal Environment | Static exchange gas cooling (no convective flow) |
| Optional Sample Stage | ±15 mm axial translation + 360° rotation about vertical axis |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TeslatronPT |
| Maximum Magnetic Field | 18 T |
| Temperature Range | 1.5 K to 300 K (standard VTI) |
| Sample Bore Diameter | 50 mm |
| Cooling Method | Single-pulse-tube cryocooler |
| Sample Access | Top-loading probe mechanism |
| Vibration Level | Ultra-low (suitable for SQUID, STM, and optical spectroscopy) |
| Internal Cold Trap | Yes |
| Gas Exchange Mode | Static exchange gas (no forced flow across sample) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Triton |
| Cooling Power | >12 µW @ 20 mK (Triton 500), >6 µW @ 20 mK (Triton 300) |
| Base Temperature | < 10 mK |
| Sample Space | Ø290 mm × H240 mm (extendable to 440 mm) |
| Magnetic Field Compatibility | Up to 14 T |
| Helium-3 Inventory | 18 L (Triton 500), 11 L (Triton 300) |
| Cool-down Time | < 24 h |
| Operating Temperature Range | 10 mK – 30 K (full field) |
| Cryocooler | 1–2 W Pulse Tube Refrigerator |
| Compliance | Fully compatible with ISO/IEC 17025-aligned lab infrastructure, supports GLP/GMP audit trails via optional integrated logging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TritonXL |
| Minimum Base Temperature | < 5 mK |
| Refrigeration Power | 1000 µW at 100 mK |
| Maximum Magnetic Field Compatibility | Up to 16 T |
| Integrated Cryocoolers | Dual 1.5 W Pulse Tube Refrigerators |
| Standard Warranty | 3 years (covers all system components, including third-party cryocoolers, pumps, and electronics) |
| Service Support | Factory-authorized service network across UK, Germany, USA, China, Japan, and India |
| Vibration Mitigation | Remote pump rack, rigid floor-standing cryostat support, electrical isolation between cryostat, gas lines, and pump station |
| Gas Handling System | Dry, oil-free pumping stack (roots + diaphragm + turbomolecular pumps), fully welded pneumatic circuit with high-integrity solenoid valves |
| Sample Access | Top- and bottom-loading options |
| RF Wiring Capacity | Up to 72 semi-rigid coaxial lines with optimized attenuators |
| Optical Integration | Optional fiber feedthroughs or optical windows |
| Control Interface | Advanced software suite with remote command protocol (TCP/IP), hardware interlocks, and audit-trail-capable operation logging |
| Brand | Deepflow |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Region of Origin | Domestic (China) |
| Model | CY0G0TNP2 |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | P500 |
| Pricing | Available Upon Request |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurin i4 |
| Isolation Start Frequency | 0.6 Hz |
| Peak Isolation Performance | −40 dB at 10 Hz (99% vibration attenuation) |
| Settling Time | 0.3 s |
| Degrees of Freedom | 6-DOF active compensation |
| Power Supply | Standard AC outlet (no compressed air required) |
| Load Auto-Adaptation | Yes |
| Transport Lock | Integrated and automatic |
| Structural Stiffness | High intrinsic rigidity for positional stability |
| Compliance | Designed for ISO 14644-1 Class 5–8 cleanroom environments and compatible with GLP/GMP-aligned lab infrastructure |
| Brand | Park Accurion |
|---|---|
| Origin | Germany |
| Model | Accurion Nano Series |
| Type | Active 6-DOF Vibration Isolation System |
| Operating Frequency Range | Active isolation from 0.7 Hz, passive isolation up to 200 Hz |
| Setup Time | < 0.3 s |
| Power Supply | Standard AC mains (no compressed air required) |
| Controller | External low-heat, EMI-isolated electronics unit |
| Structural Frame | Optional welded steel support table with high horizontal & vertical stiffness |
| Compliance | Designed for ISO 14644-1 Class 5 cleanroom-compatible environments and GLP/GMP-aligned lab infrastructure |
| Sample Load Capacity | Optimized for light-weight, high-sensitivity instruments (e.g., AFM, optical interferometers, nanoindenter stages) |
| Brand | Park SYSTEMS |
|---|---|
| Origin | Germany |
| Model | i4 |
| Dimensions | 400 × 500 × 90 mm |
| Payload Capacity | 0–120 kg |
| Active Isolation Bandwidth | 0.6/1 Hz to 200 Hz |
| Degrees of Freedom | 6-DOF |
| Settling Time | ≤ 0.3 s |
| Power Supply | Standard AC Mains (No Compressed Air Required) |
| Stiffness at 1 Hz | 20–30× Higher Than Passive Air Tables |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | CDAS HL 65 |
| Flow Rate | 55–300 m³/h |
| Operating Pressure | 4–16 bar |
| Pressure Dew Point | –20 °C to –70 °C |
| Filter Certification | ISO 8573-1 compliant (OIL-X series) |
| Desiccant Cartridge Lifetime | 5 years |
| Warranty | 10 years |
| Installation | Pallet-truck compatible |
| End Cap Type | Threaded |
| Purge Control | Tool-free adjustable minimum operating pressure setting |
| Flow Optimization | Low-pressure-drop valve architecture with robust cylinder design |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | HFX |
| Nitrogen Generation Principle | Membrane Separation |
| Output Flow Rate | 40–1200 L/min |
| Output Pressure | 4–10 bar |
| Nitrogen Purity | 95–99.5% |
| Dew Point | −50 °C |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | LCMS20-0 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 20 L/min |
| Output Pressure | 100 psi (7 bar) |
| Nitrogen Purity | ≥99.9% |
| Dew Point | −40 °C |
| Dimensions (W×H×D) | 510×705×555 mm |
| Weight | 89 kg |
| Compressor Integration | Air-integrated (LCMS20-1 variant available) |
| Compliance | ISO 9001 certified design, CE marked, compliant with IEC 61010-1 for laboratory equipment safety |
| Brand | Parker |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 20H / 40H / 60H |
| Hydrogen Generation Principle | Pure Water Electrolysis |
| Output Flow Rate | 160–500 mL/min (model-dependent) |
| Output Pressure | 5–100 psi (adjustable) |
| Hydrogen Purity | ≥99.9999% |
| Power Consumption | 50 W (at nominal load) |
| Gas Outlet | 1/8″ Swagelok® compression fitting |
| Dimensions (W×H×D) | 245 × 643 × 724 mm |
| Weight | 34 kg |
| Dryer Type | Integrated desiccant-based purification module |
| Safety Certifications | CE, UKCA, UL-compliant design architecture |
| Compliance | Designed to meet ISO 8573-1:2010 Class 1 for gaseous impurities (H₂O, O₂, total hydrocarbons), compatible with GLP/GMP laboratory environments and FDA 21 CFR Part 11 data integrity requirements when integrated with validated software |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | G6 / G7 |
| Nitrogen Flow Rate | 0.6 L/min (G6), 3.0 L/min (G7) |
| Air Flow Rate | 1.5–3.0 L/min (G6), 3.0 L/min (G7) |
| Nitrogen Purity | ≥99.999% |
| Dew Point (Air) | ≤–40 °C |
| Outlet Pressure | 5 bar |
| Dimensions (W×H×D) | 345×842×413 mm (G6), 345×874×663 mm (G7) |
| Weight | 54 kg (G6), 80 kg (G7) |
| Integrated Oil-Free Compressor | Yes |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | H-MD |
| Hydrogen Generation Principle | Deionized Water Electrolysis |
| Hydrogen Purity | 99.99995% |
| Power Consumption | 100 W |
| Flow Rates | 160 / 250 / 500 / 1100 mL/min |
| Dryer Technology | Regenerable Dual-Column Micro Dryer |
| Moisture Content | <1 ppm |
| Safety | 7-Mode Fault Protection System |
| Compliance | ISO 9001 Certified Design |
| Brand | Parker Domnick Hunter DH |
|---|---|
| Origin | United Kingdom |
| Model | Hunter H |
| Hydrogen Generation Principle | Pure Water Electrolysis |
| Output Pressure | 5–100 psi |
| Hydrogen Purity | >99.99995% |
| Power Consumption | 100 W |
| Certifications | CE, UL |
| Water Reservoir Capacity | 5 L |
| Continuous Operation | 24/7, 365 days/year |
| Safety Features | Automatic H₂ Leak Detection, Water Level & Conductivity Monitoring, Self-Diagnostic System, Eco-Friendly Filter |
| Optional | Auto-Refill Function |
| Compliance | ISO 9001 certified manufacturer |
| Brand | Parker Domnick Hunter |
|---|---|
| Origin | United Kingdom |
| Model | LCMS64/65 (Hunter Series) |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve |
| Output Flow Rate | 18 L/min |
| Output Pressure | 7 bar |
| Nitrogen Purity | >99.999% (for collision gas stream) |
| Dew Point | −40 °C |
| Certifications | CE, UL |
| Compliance | ISO 9001 certified manufacturing |
| Phthalate-Free Construction | Yes |
| Integrated Oil-Free Compressor | Yes |
| Control Interface | LCD microprocessor-based controller |
| Monitoring | Five inline pressure gauges |
| Maintenance Alerts | Automated system diagnostics and service prompts |