| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NITROSOURCE PSA |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 55–2600 L/min |
| Output Pressure | 4–11 bar |
| Nitrogen Purity | 95%–99.9995% |
| Dew Point | −40 °C |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | UHP-10ZA-S, UHP-35ZA-S, UHP-50ZA-S, UHP-75ZA-S, UHP-150ZA-S, UHP-200ZA-S, UHP-300ZA-S |
| Hydrocarbon Content | < 0.1 ppm |
| Output Flow Rate | 1.0–30.0 L/min |
| Dew Point | ≤ –40 °C (typical, after integrated drying) |
| Inlet Connection | 1/8″ or 1/4″ Swagelok® |
| Outlet Connection | 1/8″ or 1/4″ Swagelok® |
| Dimensions (W×H×D) | 340 × 455 × 425 mm (UHP-10ZA-S to UHP-75ZA-S) |
| Weight | 10.2–14.2 kg |
| Filtration Stages | OIL-X EVOLUTION A0 (coalescing), catalytic oxidation unit, OIL-X EVOLUTION AA (0.01 µm final particulate) |
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | UHPN2-550C-E / UHPN2-750C-E / UHPN2-1500C-E / UHPN2-3000C-E |
| Nitrogen Purity | >99.9995% |
| Flow Rate | 0.55–3.0 L/min |
| Outlet Pressure | 5–7 bar (adjustable) |
| Integrated Oil-Free Compressor | Yes |
| Air Inlet Requirement (for non-C models) | 3–11.7 L/min @ 9 bar |
| Dimensions (W×H×D) | 345×869×417 mm (UHPN2-550/750-C) / 345×869×667 mm (UHPN2-1500/3000-C) |
| Weight | 44–93 kg |
| Compliance | ISO 9001 certified design, CE marked, meets IEC 61000-6-3/6-4 EMC requirements |
| Brand | Parker Domnick Hunter |
|---|---|
| Origin | United Kingdom |
| Model | UHPN2 |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 1 L/min |
| Output Pressure | 100 psi (5 bar) |
| Nitrogen Purity | >99.9995% |
| Dew Point | −62 °C |
| Hydrocarbon Content | <0.1 ppm |
| Particulate Class | ISO 8573-1:2010 Class 2 |
| Certifications | CE, UL |
| Compressor Type | Integrated Oil-Free Modular Air Compressor |
| Control Interface | LCD Microprocessor Controller |
| Operating Mode | ECO Adaptive Demand-Based Operation |
| Regeneration | Fully Auto-Regenerating PSA System |
| Molecular Sieve Technology | Snowstorm™ Packing |
| Noise Reduction | Acoustically Enclosed Compressor Housing |
| Monitoring | Three Independent Pressure Gauges |
| Maintenance Alert | Real-Time Predictive Maintenance Notification |
| Brand | Parker |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | UHPZN2-1000C-E |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) |
| Output Flow Rate | 1.0 L/min |
| Output Pressure | 5–7 bar (adjustable) |
| Nitrogen Purity | ≥99.9995% (v/v) |
| Hydrocarbon Content | <0.1 ppm (as CH₄ equivalent) |
| Dew Point | ≤–70 °C (at 5 bar) |
| Integrated Oil-Free Compressor | Yes |
| Dimensions (W×H×D) | 534 × 586 × 966 mm |
| Weight | 79.6 kg |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | FID-2500 |
| Output Purity | 99.9995% H₂ |
| Zero Air THC | <0.1 ppm |
| Capacity | Supports up to 11 FID detectors |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 483 × 584 × 356 mm (W × D × H) |
| Weight | 42 kg |
| Compliance | CE, UL 61010-1, ISO 8573-1 Class 1 for compressed air feed |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | MGG-400 |
| Gas Purity | <0.05 ppm THC (as methane) |
| Output Capacity | Sufficient for 5–6 FID detectors |
| Regulatory Compliance | Designed for GLP/GMP-aligned laboratories |
| Noise Level | <45 dB(A) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions | 43.2 × 48.3 × 27.9 cm (W×D×H) |
| Weight | 22.7 kg |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model Series | NitroFlow Lab, N2-04 / N2-14 / N2-22 / N2-35 / N2-45 / N2-80 / N2-135 |
| Flow Rate Range | 4–467 L/min |
| Nitrogen Purity | ≥99.5% (standard models), up to 99.999% (LCMS-SF series) |
| Technology | Hollow-Fiber Membrane Separation |
| Power Requirement | None (for air-fed split-system configurations) |
| Compliance | Phthalate-free, VOC-free, MS-compatible design |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | TOC-1250 |
| Gas Output Purity | < 0.1 ppm HC, < 0.5 ppm CO₂ |
| Flow Rate | Up to 12 L/min |
| Operating Pressure | 5–10 bar (adjustable) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 500 × 580 mm |
| Weight | 28 kg |
| Compliance | CE, UL 61010-1, ISO 8573-1 Class 1 for hydrocarbons and CO₂ |
| Brand | Parker |
|---|---|
| Origin | USA |
| Model | UHPN2-1100UK / HPN2-2000UK |
| Flow Rate | 1.1 L/min (UHPN2-1100UK), 2.0 L/min (HPN2-2000UK) |
| Purity | 99.9999% (UHPN2-1100UK), 99.99% (HPN2-2000UK) |
| Input | Compressed Air |
| Certification | CE, UKCA, ISO 9001-compliant design |
| Dimensions | Compact benchtop footprint (<450 mm W × 400 mm D × 500 mm H) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | Parr Modular Reaction System (MRS) with 16-Station High-Throughput Configuration |
| Reactor Type | Benchtop Batch/Parallel Autoclave Reactor |
| Heating Method | Electric Cartridge Heaters with Aluminum Block Thermal Management |
| Control Architecture | Dual 4871 Process Controllers with 16 × 4875 Power Modules |
| Pressure Rating | Up to 2000 psi (13.8 MPa) |
| Temperature Range | Ambient to 350 °C |
| Vessel Capacity | Standard 4560 Microreactors (25–100 mL) |
| Stirring | Magnetic or Mechanical Drive Options |
| Safety Features | Rupture Discs, Pressure Relief Valves, Interlocked Access Doors |
| Compliance | Designed per ASME BPVC Section VIII Div. 1, CE Marked for EU Lab Use |
| Software Interface | Parr PC-Based Control Suite (Supports ASTM E2500-19, FDA 21 CFR Part 11 Audit Trail & Electronic Signature Ready) |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 3900 Series |
| Operating Pressure | Up to 5 atm |
| Max. Temperature | 80 °C |
| Drive Mechanism | Motorized Oscillating Motion |
| Heating Method | External Electric Heating Jacket |
| Temperature Control | PID Controller with Internal Thermocouple Feedback |
| Safety Certification | Explosion-Proof Options Available |
| Compliance | Designed for GLP-compliant hydrogenation research in pharmaceutical development |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4500 Series |
| Vessel Capacity | 0.075–2 L |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 3000–5000 psi (207–345 bar) |
| Vacuum Capability | Yes (rated for full vacuum to full positive pressure) |
| Drive Type | Magnetic Coupling or Gear-Driven Stirring |
| Temperature Range | Up to 540 °C |
| Certifications | ASME Section VIII Div. 1, UL/cUL, CSA, CE, ISO 9001 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4520 |
| Volume Range | 1000 mL – 2000 mL |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Vacuum Capability | Not Designed for Vacuum Service |
| Regulatory Compliance | Compliant with ASTM G187 (High-Pressure Reaction Vessel Safety), FDA-relevant design principles for pharmaceutical process development |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4530 Series |
| Vessel Capacity | 1000 mL / 2000 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm (13.2 MPa) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4540 Series |
| Vessel Capacity | 600 mL / 1200 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 345 atm (5000 psi) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Configuration | Benchtop & Floor-Standing Options |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4550 Series |
| Volume Options | 3.75 L (1 gal) and 7.5 L (2 gal) |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, uV, ISO 9001 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4555 Series |
| Price Range | USD $130,000–$260,000 (FOB) |
| Usable Volume | 10 L to 18.75 L |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy C-276, Hastelloy C-2000 |
| Vacuum Capability | Not rated for vacuum service |
| Certification | ASME Section VIII Div. 1, UL/cUL Listed (uV), ISO 9001:2015, CSA C22.2 No. 61010-1, CE Marked |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4560 Pressure Stirred Autoclave |
| Volume Range | 100–600 mL (Models 4561–4568) |
| Max Operating Pressure | 200 bar |
| Max Operating Temperature | 225–350 °C |
| Configuration | Benchtop Miniature Autoclave System |
| Certification | ASME BPVC Section VIII Div. 1 Compliant Vessels |
| Drive Type | Magnetically Coupled or Mechanical Seal Stirring Assembly |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4590 Series |
| Working Pressure | Up to 575 bar |
| Maximum Temperature | Up to 600 °C |
| Vessel Volume Options | 25 mL – 18.75 L |
| Construction Materials | ASTM-certified alloys (e.g., 316 SS, Hastelloy C-276, Inconel 600, Titanium Grade 2, Zirconium), borosilicate glass, or PTFE-lined configurations |
| Stirring Options | Magnetic drive (0–1800 rpm), gear-driven, pneumatic, or explosion-proof motorized agitators |
| Heating Methods | Electric heating mantle, aluminum block heater, steam/oil jacket |
| Closure Types | Clamp-style (open-loop) or threaded (screw-cap) head design |
| Certifications | ASME Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4632 |
| Price Range | USD 68,000 – 109,000 (estimated) |
| Maximum Operating Pressure | 10,000 psi (68.9 MPa) |
| Maximum Temperature | 200 °C |
| Extraction Vessel Volume | 2 L |
| Siphon Cup Volume | 450 mL |
| Solvent Flow Cycles | 15–22 cycles/hour |
| Total Extraction Duration | Up to 6 h |
| Compliance | ASTM D2307, ASTM D3455, IEC 60851-5, UL 1446 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | Parr 4871 |
| Configuration | Fully Automated Continuous Flow Tubular Reactor System |
| Core Components | Integrated Gas/Liquid Feed System, Jacketed Tubular Reactor with Preheater & Circulating Water Bath, Product Collection & Back-Pressure Regulation, Automated Sampling Unit, PARR 4871 Process Control System |
| Compliance Framework | Designed to support GLP-compliant process development and ASTM D6866 / ISO 13877-aligned biofuel characterization workflows |
| Regulatory Readiness | Supports 21 CFR Part 11–compliant audit trails via optional software validation package |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Parr 4871 |
| Pricing | Available Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 4871 High-Pressure, Precision-Temperature-Controlled Corrosion Research System |
| Pricing | Upon Request |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4878 |
| Operating Pressure | 5000 psi |
| Operating Temperature | 500 °C |
| Sample Capacity | 6 vials |
| Dimensions | 35 × 40 × 110 cm |
| Compliance | Compatible with all standard Parr autoclaves and pressure vessels |
| Purge Function | Integrated automated inert-gas purge cycle |
| Control Interface | Touchscreen HMI with graphical workflow display |
| Connectivity | iOS/Android remote monitoring support |
| Footprint | 33 × 33 cm |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 5100 |
| Capacity Range | 300 mL – 1800 mL |
| Vessel Material | Borosilicate Glass (Class A) |
| Maximum Operating Pressure | 10 atm (glass vessel) / 65 atm (stainless steel variant) |
| Maximum Temperature | 200 °C |
| Stirring Speed | Up to 1800 rpm |
| Sealing System | O-ring–based open-loop closure with high-temp elastomer (FKM/Viton®) |
| Jacket Type | Optional glass-jacketed, stainless steel, or removable electric heating mantle |
| Vacuum Capability | Not rated for vacuum service |
| Compliance | Designed per ASTM E2479 and ISO 17025–aligned laboratory practice guidelines |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 5400 |
| Type | Continuous Tubular High-Temperature High-Pressure Reactor System |
| Maximum Temperature | 300–600 °C (customizable) |
| Maximum Pressure | 200–350 bar (customizable) |
| Tube Diameter | 1/2″ to 4″ |
| Tube Length | 12″ to 70″ |
| Construction Materials | Stainless Steel, Alloy 400, Hastelloy C-276, Hastelloy B3, Titanium Grades 2/4/7, Monel 400, Nickel 200 |
| Brand | PARR |
|---|---|
| Model | Parr Acid Digestion Bomb |
| Construction | Stainless Steel Body with PTFE (Teflon) Liner |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1800–5000 psig |
| Sample Volume Capacity | 23–125 mL |
| Application | Closed-Vessel Acid Digestion for Trace Element Analysis |
| Compliance | Designed for ASTM D5174, EPA Method 3050B/3051A/3052, ISO 11466, and USP <231> sample preparation workflows |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Parr ASTM G146 |
| Pricing | Upon Request |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | G-T-O |