Common Laboratory Equipment
Filter
Showing 10381–10410 of 18041 results
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Liquidator 96 |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104 |
| Readability | 0.1 mg |
| Max Capacity | 120 g |
| Pan Diameter | Ø90 mm |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Net Weight | 4.5–4.7 kg |
| Calibration | Fully Automatic Internal Calibration |
| Compliance | ISO/GLP-compliant data logging (date/time stamp), supports audit-ready workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME104E |
| Maximum Capacity | 120 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.5–4.7 kg |
| Calibration | Internal (one-key auto-calibration) |
| Built-in Applications | 10 (e.g., formulation, counting, density, % weighing, checkweighing, statistics) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204 |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.5–4.7 kg |
| Internal Calibration | Yes |
| Built-in Applications | 10 (e.g., formulation, counting, density, % weighing, checkweighing, statistics) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | ME204E |
| Maximum Capacity | 220 g |
| Readability | 0.1 mg |
| Repeatability | 0.1 mg |
| Linearity | ±0.2 mg |
| Stabilization Time (typical) | 2 s |
| Sensitivity to Temperature Drift | 2.0 ppm/°C |
| Pan Diameter | Ø90 mm |
| Net Weight | 4.7 kg |
| Calibration | Internal (built-in motorized calibration mass) |
| Compliance | ISO/IEC 17025, GLP, GMP (21 CFR Part 11-ready with optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | OptiMax™ |
| Temperature Range | −40 to 180 °C (jacket) |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Vessel Volume | 8–1000 mL |
| Stirring Speed | 30–1200 rpm (±5 rpm) |
| Dimensions | 388 × 414 × 539 mm (W × D × H) |
| Weight | 35 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Type | Single-Channel Manual Pipette |
| Sterilization | Autoclavable (full liquid end, including seals and piston) |
| RFID Integration | Yes, for GLP/GMP-compliant service and calibration traceability |
| Ergonomic Design | Low-force plunger activation, optimized grip geometry, glove-compatible volume lock |
| Tip Ejection | Reinforced high-density polymer ejector arm with one-step removal for cleaning |
| Compliance | Designed to support ISO 8655, ASTM E1154, and FDA 21 CFR Part 11–aligned laboratory documentation workflows |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | L-10XLS+/L-20XLS+/L-100XLS+ |
| Channel Count | 1 |
| Maximum Volume | 2000 µL |
| Accuracy | ±1% at 20 µL, ±0.8% at 200 µL |
| Automation Level | Manual |
| Sterilization | Fully Autoclavable (Liquid End, Sleeve, Ejector) |
| RFID Integration | Yes (for Calibration Tracking & Inventory Management) |
| Tip Ejection System | LTS™ LightTouch System with High-Density Polymer Ejector |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickFlow |
| Quotation | Upon Request |
| Ultimate Vacuum | Not Applicable |
| Maximum Pumping Speed | Not Applicable |
| Dimensions | Not Specified |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | E4 XLS+ |
| Channel Configurations | 1-, 6-, 8-, and 12-channel |
| Volume Range | 0.5–10 µL, 1–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 20–300 µL, 100–1000 µL, 100–1200 µL, 200–2000 µL, 500–5000 µL, 1–10 mL, 2–20 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Pipet-Lite XLS+ |
| Volume Range | 0.1–20 mL (multiple fixed-volume variants) |
| Sterilization | Autoclavable (121°C, 20 min) |
| Tip Compatibility | LTS (Low-Torque Seal) and universal conical tips |
| Ergonomic Design | Integrated finger hooks, thumb cushion, internal dampening mechanism |
| Compliance | ISO 8655 compliant |
| RFID | Embedded for asset tracking |
| Channel Options | 1-, 6-, 8-, and 12-channel |
| Adjustable Spacing | 9–14 mm (8-channel), 9–19 mm (6-channel) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | USA |
| Model | Pipet-One / LTS / XLS |
| Type | Manual Single-Channel Pipettes |
| Compliance | ISO 8655, GLP/GMP-ready |
| Tip Compatibility | LTS (Low-Torque Seal) and Universal Conical |
| Calibration Support | MCP Calibration Workstation (ISO 8655-compliant) |
| Ergonomics | Optimized grip geometry, reduced tip ejection force (<15 N), adjustable volume lock |
| Brand | RAININ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | Single-Channel / Multi-Channel / Classic / Electronic / Manual |
| Pricing | Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model No. | 30551512 |
| Vacuum Range | –20 kPa to –70 kPa |
| Maximum Aspiration Rate | 15 mL/s |
| Dimensions (W × D × H) | 460 × 200 × 400 mm |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Domestic |
| Model No. | 30564095 |
| Instrument Type | Single-Channel Pipette |
| Automation Level | Motorized |
| Channel Count | Single |
| Volume Range | 10–1000 µL |
| Maximum Capacity | 10 mL |
| Accuracy Tolerance | ±3–10% |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RX-10 |
| Application Scope | Jacketed laboratory reactors (mL to L scale) |
| Integrated PAT Compatibility | In-situ pH, FTIR, FBRM, PVM, particle size analysis |
| Control Interface | Touchscreen + iC/iControl software suite |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signature, data integrity features |
| Thermal Control Integration | Compatible with external chillers, heaters, and circulators |
| Data Acquisition | Synchronized timestamped logging of temperature, stirring speed, dosing volume, pH, and PAT sensor streams |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Product Type | Pre-sterilized, Recyclable Tip Rack System |
| Material Composition | Primarily PETE (Polyethylene Terephthalate) |
| Sterilization | Gamma-irradiated, ISO 11137 compliant |
| Environmental Certification | 100% recyclable per ISO 14021 |
| Packaging Efficiency | 50% less plastic vs. conventional tip racks |
| Compressibility | High — post-use volume reduction >60% in waste stream |
| Regulatory Compliance | Meets EU Directive 2002/96/EC (WEEE) and EN 13432 for recoverability |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-2000 |
| Instrument Type | High-Pressure Homogenizer |
| Max Operating Pressure | 2,000 psi |
| Max Flow Rate | 2,000 mL/min |
| Feed Temperature Range | up to 75 °C (165 °F) |
| Compressed Air Requirement | 24 SCFM at 50 psi, dew point −17.7 °C to 1.6 °C |
| Minimum Sample Volume | 100 mL |
| Dimensions | 44 × 44 × 51 cm |
| Weight | 16.8 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Drive Mechanism | Pneumatic |
| Clean-in-Place (CIP) | Yes |
| Sterilization Compatibility | Autoclavable & SIP-capable |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-2000 |
| Pricing | Available Upon Request |
| Max Operating Pressure | 2,000 psi |
| Max Flow Rate | 2,000 mL/min |
| Feed Temperature Limit | 75 °C (165 °F) |
| Compressed Air Requirement | 24 SCFM at 50 psi, Dew Point: −17.7 to 1.6 °C |
| Minimum Sample Volume | 100 mL |
| Dimensions | 44 × 44 × 51 cm |
| Weight | 16.8 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Drive Type | Pneumatic, Explosion-Proof Certified |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-5000 |
| Instrument Type | High-Pressure Homogenizer |
| Max Operating Pressure | 5,000 psi |
| Max Flow Rate | 950 mL/min |
| Feed Temperature Range | –15–165 °F (–26–74 °C) |
| Compressed Air Requirement | 28 SCFM at 50 psi, Dew Point: –17.7–1.6 °C |
| Minimum Sample Volume | 100 mL |
| Dimensions | 44 × 44 × 51 cm |
| Weight | 16.8 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Cleaning | In-line CIP-capable |
| Certification | Validated for Steam Sterilization (SIP) and Autoclave Compatibility |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HC-8000/3A |
| Pricing | Available Upon Request |
| Max. Operating Pressure | 1,000–8,000 psi |
| Max. Flow Rate | 1,000 mL/min |
| Max. Feed Temperature | 75 °C (165 °F) |
| Compressed Air Requirement | 57 SCFM at 50 psi, dew point −17.7 to 1.6 °C (0–35 °F), 15 hp (11 kW) |
| Minimum Sample Volume | 250 mL |
| Dimensions | 58 × 38 × 58 cm |
| Weight | 26.7 kg |
| Construction Material | Electropolished 316 Stainless Steel |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110EH30 |
| Instrument Type | High-Pressure Homogenizer |
| Max Operating Pressure | 30,000 psi (2070 bar) |
| Max Flow Rate | 450 mL/min |
| Max Feed Temperature | 75 °C |
| Motor Power | 5 HP (3.7 kW) |
| System Fluid Volume | 100 mL |
| Compressed Air Requirement | 50 psi, 1 SCFM, dew point 0–35 °F |
| Minimum Sample Volume | 120 mL |
| Dimensions | 84 × 87 × 148 cm |
| Weight | 205 kg |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M-110P |
| Instrument Type | High-Pressure Homogenizer |
| Drive System | Hydraulic |
| Max Pressure | 30,000 psi |
| Flow Rate | 110–150 mL/min |
| Minimum Sample Volume | 25 mL |
| Interaction Chamber Material | Diamond (U.S. Patented) |
| Piston Material | Zirconia |
| Temperature Control | Integrated Inline Cooling System |
| Power Supply | 220 V AC |
| Brand | MicaSense |
|---|---|
| Model | Altum |
| Sensor Type | Integrated Multispectral + LWIR Thermal + RGB Imaging System |
| Spectral Bands | 5 Discrete Multispectral (Blue, Green, Red, Red Edge, NIR) + Uncooled Microbolometer Thermal (11 µm) |
| Thermal Resolution | 160 × 120 px |
| Multispectral Resolution | 2064 × 1544 px per band (3.2 MP × 5) |
| Pixel Size | 3.45 µm (MS), 12 µm (LWIR) |
| FOV (MS) | 48° × 36.8° |
| FOV (Thermal) | 57° × 44.4° |
| GSD @ 120 m | 5.2 cm (MS), 81 cm (Thermal) |
| GSD @ 60 m | 2.1 cm (MS), 41 cm (Thermal) |
| Thermal Sensitivity | <50 mK |
| Output Format | Radiometrically Calibrated 16-bit TIFF |
| Storage Interface | USB 2.0 (up to 128 GB removable flash) |
| Weight | 357 g |
| Dimensions | 82 mm × 67 mm × 64.5 mm |
| Shutter | Global Shutter (Circular Aperture) |
| Data Interface Options | Ethernet or UART for real-time camera control and telemetry |
| Compliance | Designed for ASTM E2912-23 (Aerial Remote Sensing), ISO 18436-3 (Condition Monitoring), and compatible with FDA 21 CFR Part 11–compliant workflows when deployed in GLP/GMP agricultural research environments |
| Brand | MICCRA |
|---|---|
| Origin | Germany |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 50 × 245 mm |
| Processing Volume | 0.1–500 mL |
| Speed Range | 3,000–30,000 rpm |
| Input Power | 145 W |
| Output Power | 95 W |
| Weight | 900 g |
| Protection Rating | IP20 / Class II |
| Speed Control | Electronic, Stepless, and Stability-Regulated |
| Brand | MicCRA |
|---|---|
| Origin | Germany |
| Model | D-27 |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (H×W×D) | 120 × 275 × 220 mm |
| Processing Volume Range | 0.1 mL to 50 L |
| Motor | 3-Phase Asynchronous, 2.7 kW |
| Max Speed | 36,000 rpm |
| Noise Level | 63 dB(A) |
| IP Rating | IP54 (Motor Unit), IP20 (HFU-27 Inverter) |
| Cooling | Integrated Circulating Water Cooling |
| Sealing | Pneumatic Air-Seal System with Lifetime Grease Lubrication |
| Drive Duty Cycle | S1 (Continuous Operation) |
| Inverter Output | 3×0–220 V AC, 3.8 kVA, 50–400 Hz (up to 600 Hz) |
| USB Interface | Yes |
| Weight | 9.5 kg (Motor Unit), 4.9 kg (HFU-27 Inverter) |
| Brand | MICCRA |
|---|---|
| Origin | Germany |
| Model | D-9 |
| Instrument Type | Probe-type Rotor-Stator Homogenizer |
| Dimensions (W×D×H) | 92 × 183 × 177 mm |
| Processing Volume | 0.1–20,000 mL (H₂O) |
| Speed Range | 3,000–25,000 rpm |
| Motor | Brushless DC (BLDC) |
| Input/Output Power | 950 W / 760 W |
| Speed Display | LED TFT |
| Speed Control | PID-regulated |
| Speed Accuracy | ±100 rpm |
| Housing Material | Anodized Hard-Aluminum Alloy |
| Noise Level | ≤55 dB(A) |
| Protection Rating | IP20 |
| Overload & Thermal Protection | Yes |
| Soft Start/Stop | Yes |
| Continuous Duty Cycle | 100% |
| Power Supply | 230 V, 50/60 Hz |
| Operating Ambient Temperature | 5–45 °C |
| Relative Humidity Limit | ≤85% RH |
| Brand | MICCRA |
|---|---|
| Origin | Germany |
| Model | DFK |
| Type | Inline Circulation Homogenization Chamber |
| Compatible Hosts | MICCRA D-9, D-15, D-27 |
| Rotor/ Stator Configurations | DFK 1.0 (20/30 mm), DFK 1.4 (20/30/40 mm) |
| Max Flow Rate (Water) | 10–45 mL/min |
| Max Shear Velocity | 30–46 m/s |
| Max Operating Pressure | 8–16 bar |
| Vacuum Capability | ≤1 mbar |
| Seal Options | FDA-compliant lip seal or mechanical seal |
| CIP/SIP Ready | Yes |
| Material | Electropolished AISI 316L stainless steel |
| Hardness (Rotor/Stator) | ≤6 Mohs |
| Surface Finish | Ra ≤0.4 µm |
| Brand | MicCRA |
|---|---|
| Origin | Germany |
| Model | DS Series (Stator Diameter: 5–14 mm) |
| Probe Types | DS-5 / PEDS-8 / PDS-14 |
| Stator Outer Diameter | 5 mm / 8 mm / 14 mm |
| Rotor Outer Diameter | 3.6 mm / 5.6 mm / 10.6 mm |
| Max Tip Speed | 7.3 m/s / 11.4 m/s / 21.6 m/s |
| Probe Length | 115 mm / 155 mm / 200 mm |
| Minimum Immersion Depth | 30 mm (DS-5), 80 mm (PEDS-8), 125 mm (PDS-14) |
| Recommended Sample Volume (Water) | 0.1–20 mL / 1–100 mL / 10–500 mL |
| Rotor Type | Shearing Rotor |
| Stator Type | Toothed (Peg-Type) Stator |
| Application Domain | Microscale Biological Homogenization |
| Brand | MICCRA |
|---|---|
| Origin | Germany |
| Model | D-4 / D-4P / D-4P Mul |
| Type | Probe-type Rotational Homogenizer |
| Dimensions (W×D×H) | 80 × 175 × 230 mm |
| Weight | 3 kg |
| Max. Sample Volume (H₂O) | 2 L (D-4), 5 L (D-4P & D-4P Mul) |
| Max. Viscosity | 8,000 mPa·s |
| Motor | Brushless DC |
| Input/Output Power | 450 / 360 W |
| Speed Range | 3,000–25,000 rpm (D-4), 1,500–15,000 rpm (D-4P/D-4P Mul) |
| Speed Setting Resolution | ±100 rpm |
| Timing Range | 0–999 h 59 min 59 sec |
| Programmable Steps | 6-segment (speed + time per step) |
| Temperature Monitoring | Yes (external probe optional), ±0.5 °C accuracy |
| Screen | 3.5″ TFT capacitive touchscreen |
| IP Rating | IP42 |
| Power Supply | 230 V AC, 50/60 Hz |
| Continuous Duty Cycle | 100% |
| Safety Features | Overload & thermal protection, soft start/stop, screen lock, max. temperature cutoff |
| Connectivity | Integrated Wi-Fi for remote monitoring and control via mobile device |