Empowering Scientific Discovery

Dalian Lidi Fluid Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandART Photonics
OriginGermany
ModelFORO-L-3/5-F10
Spectral Range3–5 µm
Lens MaterialZnSe
Lens TypePlano-Convex
Focal Length10 mm
Numerical Aperture0.35
Outer Diameter25 mm
ThreadM24×1
HousingAnodized Aluminum (Black)
AR CoatingOptimized for 3–5 µm
Compatible ConnectorsSMA, FC/PC
Weight~45 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandART Photonics
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPIR Fiber
Spectral Range3–17 µm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandART Photonics
OriginGermany
ModelCIR Fiber 1.5–6 µm
Spectral Range0.18–1.2 µm (UV-VIS)
Detector TypeCCD
Resolution30
Sensitivity400
Signal-to-Noise Ratio1001
Core Diameter Options200–1500 µm
Numerical Aperture0.22 ± 0.02 (25° full acceptance angle)
Operating Temperature−40 °C to +600 °C (copper-coated variant)
Connector TypesHP-SMA, D-80
Cable Lengths1.5 m, 3.0 m (custom lengths from 5 cm to 50 m)
Cladding MaterialFluorine-doped fused silica
Core MaterialHigh-OH⁻ or Low-OH⁻ fused silica
Jacketing OptionsNylon, Tefzel, acrylic, aluminum, copper
Protective SheathingPVC-coated stainless steel coil, silicone-coated stainless steel bend protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAdvanced Fiber Tools
OriginGermany
Detector TypeCMOS
Spectral Range1500–2600 nm
Resolution2300
Sensitivity2000
Core MaterialLow-OH Fused Silica
Cladding MaterialFluorinated Fused Silica
Coating OptionsAcrylate (−40°C to +85°C), Silicone (−40°C to +180°C), Polyimide (−190°C to +385°C)
Numerical Aperture0.22 ± 0.02
Core/Clad Ratio1.1, 1.2, or 1.4
BiocompatibilityISO 10993-compliant
Sterilization CompatibilityETO, Steam, Electron Beam, Gamma
Radiation & Laser Damage ResistanceYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandINSION
OriginGermany
Model2C UV VIS
Optical ArchitectureSingle-beam
Detector TypePhotodiode Array
Spectral Range2 × 350–1050 nm
Wavelength Accuracy< 10 nm FWHM
Spectral Resolution< 10 nm FWHM
Sensitivity> 2.0 × 10¹⁵ counts·nm/W·s at 650 nm
Optical InterfaceDual SMA 905 connectors
CalibrationFactory-calibrated, no user recalibration required
Mechanical StabilitySolid-state design, no moving parts
Operating Temperature Range5–40 °C
Dimensions≤ 65 × 45 × 25 mm
Weight< 120 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0