Empowering Scientific Discovery

Dandong Bettersize Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
ModelBeNano 90
Measurement PrincipleDynamic Light Scattering (DLS) and Static Light Scattering (SLS)
Particle Size Range0.3 nm – 15 µm
Size Reproducibility≤1%
Temperature Control Range−15 °C to 120 °C
Temperature Stability±0.1 °C
Detection Angle90°
Laser Wavelength671 nm (solid-state)
CorrelatorMulti-speed mode, 25 ns minimum sampling interval, 4000 channels, 10¹¹ dynamic linear range
DetectorAPD
Intensity Control0.0001%–100%, auto/manual
Analysis AlgorithmsCumulants, General Purpose, CONTIN, NNLS
Output ParametersHydrodynamic Diameter (D<sub>H</sub>), Polydispersity Index (PDI), Diffusion Coefficient (D), Interparticle Interaction Parameter (k<sub>D</sub>), Intensity/Volume/Area/Number Distributions, Molecular Weight (342 Da – 2 × 10⁷ Da), Solution Viscosity & Refractive Index, Viscoelastic Moduli (G*, G′, G″), Complex Viscosity (η*), Creep Compliance (J)
Optional ModulesFlow Mode (coupled with FFF/GPC/SEC), 0° PD+CMOS Module for Refractive Index & Sedimentation-Based Concentration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Regional ClassificationDomestic (China)
ModelBT-9300ST
PricingUpon Request
Dispersion MethodWet Dispersion
Instrument TypeBenchtop Laboratory Laser Diffraction Analyzer
Measurement Range0.05–1500 µm
Repeatability≤1% (D50, NIST-traceable standard reference materials)
Single-Measurement Time≤1 s
Optical SystemPatented Dual-Lens Configuration
Laser SourceHigh-Power Fiber-Coupled Laser (638 nm)
Detector Array88-Channel Photodiode Array (Forward, Side, and Backward Scattering)
Scattering TheoryMie Scattering (default), Fraunhofer Diffraction (optional)
Regulatory ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982
Data IntegrityFDA 21 CFR Part 11 Compliant Audit Trail & Electronic Signature Support
Dispersion SystemIntegrated Auto-Circulating Wet Module with Ultrasonic Probe (0–50 W, adjustable), Auto-Fill, Auto-Drain, Bubble Elimination, and Self-Cleaning Functions
Operating ModesSOP-Driven One-Touch Mode, Manual Mode, Continuous Monitoring Mode
Power Supply100–240 VAC, 50/60 Hz, 2.5 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelBeNano 180 Zeta Max
PriceUpon Request
Particle Size Range0.3 nm – 15 μm
Temperature Control Range−15°C to 120°C
Temperature Stability±0.1°C
Sample Volume3 μL – 1 mL
Zeta Potential Measurement RangeNo Practical Limit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelBT-1700
Instrument TypeStatic
Measurement Range0.3–10,000 µm
Magnification Options160×, 200×, 400×, 800×
Repeatability Error≤1% (D₅₀ deviation against national standard reference materials)
Accuracy Error≤1% (D₅₀ deviation against national standard reference materials)
IlluminationDual-mode (transmitted + reflected light)
Particle Recognition Speed≥10,000 particles/minute
Camera Resolution12 MP
Scan Area Diameter50 mm
Analysis Time per Sample≤10 minutes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBettersize2000S
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Spray Laser Particle Size Analyzer
Measurement Range0.1–2000 µm
Repeatability≤1% (D50 deviation against certified reference materials)
Measurement Time≤10 s
Optical SystemFourier Transform Configuration with Parallel Beam Path
Scattering TheoryMie Scattering (default), Fraunhofer Diffraction (optional)
Detector Array76-element photodiode array (forward and side scattering)
Sample Zone Length Adjustment0–700 mm (Standard), 0–1200 mm (Extended/Elevating/Comprehensive configurations)
IP RatingIP65
Laser SourceHigh-power semiconductor laser
MaterialFull stainless-steel construction
Data ComplianceFDA 21 CFR Part 11 audit trail support
Standards ConformanceISO 13320, GB/T 19077, GB/T 41949
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBettersize3000
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser Particle Size Analyzer
Measurement Range0.01–3500 µm
Repeatability≤0.5%
Measurement Time<10 s
Optical PrincipleMie Scattering (default), Fraunhofer Diffraction (optional), Dynamic Imaging
Detector Array96-element photodetector (forward, side, and backward angles)
Refractive Index MeasurementYes (real & imaginary components)
ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982, FDA 21 CFR Part 11
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBettersize3000Plus
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser Diffraction Analyzer
Measurement Range0.01–3500 µm
Repeatability≤0.5%
Measurement Time≤10 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
ModelBettersize2600
Dispersion MethodDry & Wet Dispersion
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.02–2600 µm (wet), 0.1–2600 µm (dry)
Repeatability≤0.5% (D50 of NIST-traceable standards)
Single Measurement Time≤1 s
Optical SystemPatented Forward-Reverse Fourier Hybrid Optical Path
Detector Channels92 (covering forward, side, and backward scattering angles)
Laser SourceHigh-Power Polarized Fiber Laser
Refractive Index MeasurementIntegrated Real-Time Sample RI Determination
ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982
Data IntegrityFDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signatures
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBettersize2000
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser Diffraction Particle Size Analyzer
Measurement Range0.02–2000 µm
Repeatability≤0.5% (D50 of NIST-traceable standard samples)
Single Measurement Time≤1 s
Optical SystemPatented Dual-Lens Optical Configuration
Laser SourceHigh-Power Fiber-Coupled Semiconductor Laser
Detector Array90-Channel Photodiode Array (Forward & Backward Scattering)
ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982
Data IntegrityFDA 21 CFR Part 11–Compliant Audit Trail & Electronic Signature Support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Product CategoryDomestic
ModelBetterPyc 380
Instrument TypeMulti-Function True Density Analyzer
Measurement PrincipleGas Pycnometry (Gas Displacement Method)
Accuracy±0.02%
Repeatability±0.01%
Resolution0.0001 g/cm³
Operating Pressure Range0–22 psig (0–152 kPag)
Compatible GasesNitrogen or Helium
Gas Inlet ModesFlow Mode & Vacuum Mode
Tubing ConnectionΦ4 mm
Sample Cup Volumes10 cm³ / 35 cm³ / 100 cm³
Sample Chamber Volume100 cm³
Temperature Range10–65 °C
Relative Humidity Range20–80 % RH
Single Measurement Time< 120 s
Pressure Sensor AccuracyBetter than 0.1 %
Power Supply100–240 VAC, 50/60 Hz, 1.4 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBulk Density Tester
ModelBT-100
ComplianceGB/T 16913–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instruments Co., Ltd.
ModelBeNano Zeta
Particle Size Range1 nm – 120 µm
Temperature Control Range−15°C to 120°C
Temperature Stability±0.1°C
Zeta Potential Measurement RangeNo practical limitation
Electrophoretic Mobility Range> ±20 µm·cm/V·s
Conductivity Range0 – ≥270 mS/cm
Laser Wavelength671 nm (solid-state laser, optional wavelengths available)
Detection Angle12°
CorrelatorMulti-mode (fast/medium/slow), 25 ns minimum sampling interval, up to 4000 channels, 10¹¹ dynamic linear range
DetectorAPD
Intensity Control0.0001% – 100%, auto/manual
Measurement PrinciplePhase Analysis Light Scattering (PALS)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
ModelBT-2800
OriginLiaoning, China
ManufacturerBettersize Instruments Co., Ltd.
Instrument TypeDynamic
Measurement Range4–400 µm
Magnification20×–1400×
Repeatability Error≤1% (D50, certified reference material)
Accuracy Error≤1% (D50, certified reference material)
High-Speed CCD120 fps
Particle Recognition Speed≥10,000 particles/min
Power Supply100–240 VAC, 50/60 Hz, 4 A
Dimensions610 × 300 × 450 mm
Weight22 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelBT-2900
Instrument TypeDynamic
Measurement Range30–10,000 µm (dry dispersion)
Sample Dispersion MethodDry & Wet
Magnification0.132×–10× (interchangeable lenses)
Repeatability Error≤1% (D50 deviation vs. national standard reference material)
Accuracy Error≤1% (D50 deviation vs. national standard reference material)
High-Speed Camera1.5 MP, 120 fps
Particle Recognition Speed≥10,000 particles/min
Power Supply220 VAC, 50/60 Hz, 4 A
Dimensions610 × 300 × 440 mm
Weight26 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instruments Co., Ltd.
ModelBeNano 180
Particle Size Range0.3 nm – 10 μm
Size Measurement Reproducibility≤1%
Temperature Control Range−15 °C to 120 °C
Temperature Control Accuracy±0.1 °C
Measurement Time≤60 s
Detection Angle173° (backscattering) + optional 11.2°
Laser Wavelength671 nm (solid-state laser)
CorrelatorMulti-speed mode, 25 ns minimum sampling interval, 4000 channels, 10¹¹ dynamic linear range
DetectorAPD
Sample Volume≥40 μL (customizable)
Max. Sample Concentration≤40% w/v
Analysis AlgorithmsCumulants, General Purpose, CONTIN, NNLS
Supported MeasurementsHydrodynamic Diameter (D<sub>H</sub>), Polydispersity Index (PDI), Diffusion Coefficient (D), Interparticle Interaction Parameter (k<sub>D</sub>), Intensity/Volume/Area/Number Distributions, Molecular Weight (342 Da – 2 × 10⁷ Da), Solution Viscosity & Refractive Index, Microrheological Parameters (G*, G′, G″, η*, J)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Product OriginDomestic (China)
ModelBeNano 90 Zeta
PriceUpon Request
Particle Size Range0.3 nm – 15 μm
Temperature Control Range−15 °C to 120 °C
Temperature Stability±0.1 °C
Measurement PrinciplesDynamic Light Scattering (DLS), Electrophoretic Light Scattering (ELS), Static Light Scattering (SLS)
Sample Volume3 μL – 1 mL
Zeta Potential RangeNo Practical Limit
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBeVision D3
Instrument TypeDynamic
Measurement PrincipleDynamic Image Analysis (DIA)
Optical SystemDual-CMOS Imaging System (BeVision D3 Pro variant) / Single-CMOS (other variants)
Measuring Range0.5–16,000 µm (model-dependent
ISO-compliant range2–8,000 µm)
Camera Resolution5 MP
Light SourceGreen LED and/or Blue LED
Repeatability (D50, standard reference material)≤0.5%
SoftwareBeVision 5.0
ComplianceISO 13322-2, ISO 9276, GB/T 21649, GB/T 15445
Dimensions (L×W×H)686 × 300 × 325 mm
Weight24 kg
Power Supply100–240 VAC, 50/60 Hz
PC RequirementsIntel Core i9 (14th gen), 32 GB RAM, Windows 10+, 1 TB SSD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
ModelBettersize2600E
Dispersion MethodDry & Wet
Instrument TypeLaboratory Laser Particle Size Analyzer
Measurement Range0.1–1500 µm
Repeatability≤0.5%
Single Measurement Time<1 s
Optical PrincipleMie Scattering (default), Fraunhofer Diffraction (optional)
Detector Channels90 (forward, side, and backward scattering)
Laser SourceHigh-power polarized fiber laser
Optical DesignInverted Fourier optical system with tilted sample cell (patented)
Refractive Index MeasurementYes (patented)
Wet DispersionAutomatic water circulation system with anti-dry-burn ultrasonic disperser (0–50 W, adjustable)
Dry DispersionStandard auto-feeder (5–20 g)
ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982
Data SecurityFDA 21 CFR Part 11 compliant
Regulatory AlignmentSupports GLP/GMP audit trails and SOP-driven workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
ModelBT-103
Measurement PrincipleFixed-base funnel method (gravity-fed conical pile formation)
Measured ParameterAngle of Repose (θr)
ComplianceGB/T 16913–2008, USP <1174>, Ph. Eur. 2.9.36
OriginLiaoning, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBT-102
Instrument TypePowder Flowability Tester
ComplianceASTM B213, ASTM B527, ISO 4490, ISO 3953
Funnel Orifice Options2.5 mm and 5.0 mm
Standard Cup MaterialStainless Steel (304)
Cup Volume25 mL
Timing Resolution0.1 s
Mass Measurement Accuracy±0.05 g
Density Reporting Precision±0.01 g/cm³
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instruments Co., Ltd.
ModelBeNano 180 Zeta
Particle Size Range0.3 nm – 10 μm
Temperature Control Range−15°C to 120°C
Temperature Stability±0.1°C
Zeta Potential RangeNo practical limit
Minimum Sample Volume40 μL (customizable)
Detection Angles173° + 11.2°
Max. Sample Concentration≤40% w/v
Zeta Measurement PrinciplePhase Analysis Light Scattering (PALS)
Electrophoretic Mobility Range> ±20 μm·cm/V·s
Conductivity Range0 – ≥270 mS/cm
Molecular Weight Range342 Da – 2 × 10⁷ Da
Laser Wavelength671 nm (solid-state), optional wavelengths available
CorrelatorMulti-speed mode, 25 ns minimum sampling interval, 4000 channels, 10¹¹ dynamic linear range
DetectorAPD
Intensity Control0.0001% – 100%, auto/manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeIn-line Laser Particle Size Analyzer
Repeatability≤2% (D50, GB Standard Reference Material)
Particle Size Range0.1–2000 µm
Sediment Concentration Range0.001–100 kg/m³
Optical Path AdjustmentAuto-adaptive 0.5–40 mm
Max Submersion Depth800 m (customizable)
IP RatingIP68
Operating Temperature0–55 °C
Depth Sensor Range0–200 m (±0.01 m accuracy)
Temperature Sensor Range−20–85 °C (±0.01 °C accuracy)
Laser SourceHigh-power fiber-coupled polarized laser
Detector Array80-element forward + side-scatter detector (0.0163°–42° angular coverage)
Data Transmission ModesWired (real-time), 4G Wireless (real-time), Offline (SD card storage, 16 GB)
Battery Standby Time≥24 h
ComplianceGB/T 15966–2017
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelBeScan Lab
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeDirect Manufacturer
Instrument TypeLaboratory Laser Particle Size Analyzer
Measurement Range0.1–1000 µm
Repeatability≤1% (D50 deviation vs. certified reference materials)
Measurement Time≤10 s per run
Dispersion MethodWet Dispersion
Optical PrincipleMie Scattering Theory (default), Fraunhofer Diffraction (optional)
Detector Array80-channel photodiode array (forward + side scattering)
Laser SourceHigh-power fiber-coupled laser
Optical DesignSingle-lens Fourier optical system
ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, USP <429>, EP 2.9.38, ChP 0982
Data IntegrityFDA 21 CFR Part 11–compliant audit trail and electronic signature support
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0