BrandBettersize
ModelBT-Online1A
Measurement PrincipleMie Scattering Theory (default), Fraunhofer Diffraction Theory (optional)
Particle Size Range0.1–2000 µm
Accuracy & Repeatability Error≤0.5% (D50 deviation against NIST-traceable or ISO-certified reference standards)
Optical SystemDual-path Fourier-optics architecture (patented forward + reverse Fourier configuration)
Detector Array92-channel photodetector (forward, side, and backward scattering)
Laser SourceHigh-power fiber-coupled laser
Sampling MethodsVenturi negative-pressure sampling (direct pipe insertion), auger-assisted Venturi sampling, or concentrator-enhanced Venturi sampling
Lens ProtectionDual-layer aerodynamic air curtain
typical maintenance-free interval12 months
Dispersion MediumCompressed air or inert gas (N₂), 0.1–0.8 MPa
Test Interval ModesContinuous measurement or programmable interval (minimum 1 s)
Monitoring Channels1–4 independent process lines (1-to-N configuration)
Dispersion ModesStandard dispersion (e.g., cement) and high-energy dispersion (e.g., alumina, hard ceramics)
Enclosure RatingIP65
Output InterfacesModbus-RTU, Modbus-TCP, 4–20 mA analog output
Data Integrity ComplianceFDA 21 CFR Part 11 (audit trail, electronic signatures, role-based access control)
Standards ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022
Power SupplyAC 220 V, 50/60 Hz, 200 W
Reporting ParametersFull size distribution, D10/D50/D90/D97/D98, volume-weighted mean D[4,3], surface-weighted mean D[3,2], specific surface area, and user-defined size fraction contents (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
ModelBT-Online1
Measurement PrincipleMie Scattering Theory (default), Fraunhofer Diffraction Theory (optional)
Particle Size Range0.1–1000 µm
Accuracy & Repeatability≤1% D50 deviation against NIST-traceable or ISO-certified reference standards
Laser SourceHigh-power fiber-coupled laser
Detector Array68-element photodiode array (forward + side scattering)
Optical DesignPositive Fourier transform optical system
Sampling MethodsVenturi negative-pressure sampling via笛-type probe or auger sampler
Lens ProtectionDual-layer aerodynamic air curtain
Dispersing MediumCompressed air or inert gas (N₂), 0.1–0.8 MPa
Test IntervalContinuous or user-defined discrete intervals (minimum 1 s)
Monitoring Channels1–4 independent process lines (1:1 to 1:4 configuration)
Dispersion ModesStandard (e.g., cement) and high-energy (e.g., alumina, hard ceramic powders)
Ingress ProtectionIP65
Output InterfacesModbus-RTU, Modbus-TCP, 4–20 mA analog output
Data Security ComplianceFDA 21 CFR Part 11 (audit trail, electronic signature, role-based access)
Standards ComplianceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022, GB/T 19077–2016, ISO 13320:2009, Q/ASA 001–2021
Power Supply100–240 VAC, 50/60 Hz, 3 A
Measured ParametersFull size distribution, D10/D50/D90/D97/D98, volume-weighted mean diameter D[4,3], surface-area-weighted mean diameter D[3,2], specific surface area, and user-definable fraction content (e.g., <3 µm, 3–32 µm, >45 µm, >80 µm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
ModelBT-Online2
PricingUpon Request
Measurement Range0.02–2000 µm
PrincipleMie Scattering Theory (default), Fraunhofer Diffraction Theory (optional)
Accuracy & Repeatability≤0.5% D50 deviation vs. NIST/ISO reference standards
CalibrationBuilt-in standard sample verification protocol
Laser SourceHigh-power fiber-coupled laser
Detector Array92-element photodetector array (forward, side, and backward scattering)
Optical DesignPatented dual-path Fourier/inverse-Fourier hybrid optical system with tilted flow cell
Sampling Methods(1) Peristaltic pump + direct suction probe
Minimum Test Interval3 min (including cleaning & priming)
Dispersion System600 mL recirculating chamber
Purified Water System40 L capacity with auto-refill, temperature stabilization (±0.5 °C), and filtration
Solvent Recovery SystemClosed-loop solvent storage, filtration, and reuse circuit
Monitoring Channels1–4 parallel process streams (1:1 to 1:4 configuration)
Output InterfacesModbus-RTU, Modbus-TCP, 4–20 mA analog output
Data Integrity ComplianceFDA 21 CFR Part 11 (audit trail, electronic signature, role-based access)
Standards ConformanceISO 13320:2020, GB/T 19077–2024, GB/T 41949–2022
Power SupplyAC 220 V, 50/60 Hz, 200 W
Key Reported MetricsD10, D50, D90, D97, D98, D[4,3], D[3,2], span, distribution trend plots