Empowering Scientific Discovery

Dandong Bettersize Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBTPM-MWS1 Constant Temperature & Humidity Weighing System
Measurement MethodGravimetric Filter Weighing
Measured ParametersPM₁₀ / PM₂.₅ / PM₁
Measurement Range0–52 mg
Cycle Time24 h
Sampling Flow Rate1.0 L/min
LOD1 µg/m³
Flow Stability±1% (not 100%)
Pre-conditioning Capacity60 × 47 mm filters / 36 × 90 mm filters / 30 filter tips or cartridges
Balance Resolution0.01 mg (0.001 mg optional)
Temperature Control Range15–30 °C (±0.5 °C)
Humidity Control Range40–60 %RH (±3 %RH)
Vibration Isolation4-stage active/passive damping platform
Electrostatic NeutralizationIonizing air bar (non-radioactive, CE-compliant)
Power SupplyAC 220 V / 50 Hz, 2000 W
Operating Environment10–40 °C, 10–75 %RH
Data InterfaceWireless tablet integration with real-time logging and export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBTPM-AWS2
Measurement MethodMembrane Gravimetry
Measured ParametersPM10, PM2.5
Measurement Range0–52 mg/m³
Sampling Cycle24 h
Sampling Flow Rate1.05 L/min ±2%
LOD1 µg/m³
Flow Stability≤±1% over 24 h
Balance Resolution0.01 mg (10 µg) or optional 0.001 mg (1 µg)
Temperature Control Range15–30 °C (adjustable, ±0.1 °C stability)
Humidity Control Range40–60 %RH (adjustable, ±3 %RH stability)
Vibration IsolationDual-Stage Quadruple-Level Isolation (4-level balance + 4-level chassis)
Electrostatic NeutralizationIonizing air bar (non-radioactive, CE-compliant)
Sample Capacity (per cycle)200 × 47 mm filters / 100 × 90 mm filters / 60 × filter tips or quartz/ceramic filter tubes
Identification SystemsRFID (47/90 mm filters), QR Code (47/90 mm), Barcode (filter tips/tubes), Binary-coded positional encoding
Conditioning Time0–48 h programmable
Water Replenishment Interval≤30 days (closed-loop humidification system)
Power SupplyAC 220 V / 50 Hz, 2000 W
ComplianceHJ 618–2011, HJ 656–2013, HJ 836–2017, ISO 12103-1, ASTM D1856, USP <661>, GLP-aligned audit trail logging
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ManufacturerBettersize Instrument Co., Ltd.
ModelBTPM-AWS1
Measurement MethodGravimetric Filter Weighing
Measured ParametersPM10, PM2.5
Measurement Range0–52 mg/m³ (as mass loading on filter)
Sampling Duration24 h per cycle
Sampling Flow Rate1.05 m³/h (±2% accuracy)
LOD1 µg/m³ (based on 24-h sampling at 1.05 m³/h and 47 mm filter)
Flow Stability±0.5% over 24 h
Balance Resolution0.01 mg (10⁻⁵ g)
Temperature Control25 ± 1 °C
Humidity Control50 ± 3 %RH
Anti-static SystemIntegrated ionizing neutralization
Vibration Isolation4-stage active/passive damping platform
Max. Batch Capacity80 filters (20 for simultaneous weighing + 40 pre-conditioning)
Filter Format47 mm diameter, any material (glass fiber, quartz, PTFE, cellulose ester)
EnclosureSealed laminar-flow chamber with HEPA-filtered air
ImagingBuilt-in CCD camera (1920×1080, timestamped, metadata-embedded)
Noise Level≤15 dB(A)
Power SupplyAC 220 V / 50 Hz, 2000 W