| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | NTU |
| Measurement Principle | 90° Infrared Light Scattering at 880 nm |
| Turbidity Range | 0–4000 NTU (5 selectable sub-ranges) |
| TSS Range | 0–4500 mg/L |
| Resolution | 0.01–1 NTU / mg/L |
| Accuracy | < ±5% of reading |
| Temperature Compensation | Integrated CTN sensor (±0.5 °C) |
| Output | Modbus RTU over RS-485 (standard), SDI-12 (optional) |
| Power Supply | 5–12 VDC |
| Typical Current Draw | 820 µA (RS-485, 1 Hz) |
| Peak Pulse | 500 mA |
| Enclosure Material | PVC, Delrin®, Quartz, PMMA, Polyamide |
| Dimensions | Ø27 mm × 170 mm |
| Weight | 300 g (sensor + 3 m cable) |
| Pressure Rating | 5 bar |
| IP Rating | IP68 |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −10 to +60 °C |
| Calibration Standards | NF EN 872 (0–500 mg/L), NFT 90 105-2 (>500 mg/L) |
| Max Refresh Rate | < 1 s |
| Brand | AQUALABO |
|---|---|
| Origin | France |
| Model | Ponsel |
| Measurement Principle | Luminescence-based Optical (OPTOD) |
| DO Range | 0.00–20.00 mg/L (ppm), 0–200% saturation |
| Resolution | 0.01 mg/L |
| Accuracy | ±0.1 mg/L (±0.1 ppm, ±1% saturation) |
| Response Time (t₉₀) | <60 s |
| Temperature Compensation | CTN thermistor |
| Storage Temperature | −10°C to +60°C |
| Output Interface | Modbus RTU over RS-485 (standard), SDI-12 (optional) |
| Power Supply | 5–12 V DC |
| Current Consumption | Standby: 25 µA |
| RS-485 mode (1 reading/s) | avg. 4.4 mA |
| SDI-12 mode (1 reading/s) | avg. 7.3 mA |
| Dimensions | Ø25 mm × 146 mm (sensor body only) |
| Weight | 450 g (sensor + 3 m polyurethane cable) |
| Housing Material | 316L stainless steel |
| Max. Operating Pressure | 5 bar |
| Connector | 9-pin waterproof subminiature connector with polyurethane overmold |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS TreeQinetic |
| Application | Non-destructive in-situ assessment of trunk and root anchorage stability under controlled tensile loading |
| Measurement Principle | Quasi-static mechanical displacement-based biomechanical response analysis |
| Key Components | Wireless elastometer (±2 mm, 0.1 µm resolution), dual-axis inclinometer (±15°, 0.002° resolution), digital forcemeter (0–60 kN, 0.01 kN resolution), overload indicator, Bluetooth-enabled data hub, and proprietary TreeQinetic software suite |
| Compliance | Designed for field use in accordance with DIN EN 1991-1-4 (wind actions), ISO 17225-6 (biomass stability reference frameworks), and GLP-aligned data integrity protocols |
| Power | Rechargeable Li-ion battery pack (10 h typical runtime at 20°C) |
| Wireless Range | Up to 30 m (line-of-sight, Bluetooth 5.0) |
| Mechanical System | Winch assembly rated for 2800 kg pulling force |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS-3 |
| Sensor Count | 6 or 12 |
| Sensor Cable Length | 3.5 m |
| Measurement Principle | Elastic Wave Propagation Time-of-Flight Tomography |
| Spatial Resolution | 1 µs time resolution |
| Operating Battery Life | >6 h |
| Charging Time | 2 h |
| GPS Accuracy | 0–20 m |
| Display | Color LCD (real-time tomographic visualization) |
| Data Transfer | USB 2.0 or Bluetooth (range: 0.5–10 m) |
| Dimensions | 55 × 42 × 13 cm |
| Weight | 8.9 kg |
| Integrated Height Measurement | Yes |
| Optional Electronic Caliper Range | 160–2150 mm (stainless steel) |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | TMS3 |
| Weight | 73 g |
| Dimensions | 61 mm × 41 mm × 20 mm |
| IP Rating | Fully Sealed, Waterproof & Dustproof |
| Tilt Measurement Accuracy | ±0.03° |
| Sampling Frequency | 20 Hz (50 ms interval) |
| Measurement Axes | 3D (X/Y/Z, cardinal directions) |
| Operating Temperature Range | −20 °C to +50 °C |
| Battery Capacity | 250 mAh |
| Continuous Operation | >15 days |
| Charging | Wireless (Qi-compatible) |
| Data Storage | 256 MB (≈20 days at 20 Hz) |
| Communication | Bluetooth 2.1 |
| Sensor Mounting | Omnidirectional |
| Control Sensor Height | 2–3 m above ground |
| Base Sensor Placement | At root collar / anchorage zone |
| Brand | Argus |
|---|---|
| Origin | Germany |
| Model | PiCUS TreeTronic 3 |
| Measurement Principle | Electrical Resistance Tomography |
| Max Electrode Count | 24 |
| Minimum Electrodes Required | 10 |
| Max Output Current | 20 mA |
| Max Output Voltage | 80 V |
| Measurement Modes | Two-point & Three-point |
| Electrode Cable Length | 3.5 m |
| Tree Diameter Range | 3–250 cm (extendable) |
| Onboard Storage | >100 scans |
| Display | Color LCD (real-time ERT visualization) |
| Data Transfer | USB 2.0 / Bluetooth |
| Integrated GPS & Bluetooth | Yes |
| Battery Life | >4 h continuous operation |
| Charging Time | ≤2 h |
| Weight | 8.9 kg |
| Dimensions | 55 × 42 × 13 cm |
| Optional Electronic Dendrometer | Range 160 mm–2150 cm, Stainless Steel Construction, LED Display, Bluetooth Sync |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS1 |
| Pricing | Upon Request |
| Brand | AMS |
|---|---|
| Origin | USA |
| Model | AMS 209.55 / 209.56 / 209.57 / 209.58 |
| Connection Thread | 5/8" UNC |
| Core Diameter Options | 5.72 cm (2.25") or 8.26 cm (3.25") |
| Handle Length | 45.72 cm (18") |
| Split-Sample Auger Dimensions | 3.49 cm × 15.24 cm or 5.08 cm × 15.24 cm |
| Rod Length | 1.2 m (4 ft) per section |
| Plastic Liner ID | 3.49 cm or 5.08 cm × 15.24 cm |
| Wrench Length | 30.48 cm (12") |
| Stainless Steel Brush Diameter | 3.81 cm or 5.08 cm × 30.48 cm |
| Standard Configuration Includes | 3 soil-specific augers (general, sand, clay), rubber-coated T-handle, split-sampling auger, slide hammer, 3 extension rods, 1 liner (25 liners in 209.58), 2 plastic caps (50 caps in 209.58), 2 fixed wrenches, 1 adjustable wrench, 1 stainless steel brush, fluoropolymer film (50 sheets in 209.56/209.58), #2 stainless steel trowel (209.56/209.58), heavy-duty portable case |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS2 |
| Pricing | Upon Request |
| Construction Material | Stainless Steel |
| Sampling Depth | Up to 3.65 m |
| Kit Components | Main Sampling Probe, Internal Liner Tube, Handle, Adapter, Extension Rod |
| Brand | AMS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS3 |
| Quotation | Upon Request |
| Sampling Capacity | 0.5 L |
| Standard Sampling Depth | 7.62 m (extendable) |
| Minimum Well Casing ID | 5.08 cm |
| Body Material | Stainless Steel |
| Sample Tube Material | Fluoropolymer |
| Valve Material | Fluoropolymer |
| Overflow Cap Material | Fluoropolymer |
| Included Components | Measured cable, cable controller, T-handle actuator, cable control accessories, fluoropolymer sample tube, fluoropolymer-valved top cap, overflow cap, two fluoropolymer tube caps |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQS1 |
| Particle Measurement | PM1, PM2.5, PM10, TSP |
| Gas Measurement | O₃ (0–0.5 ppm), NO₂ (0–0.5 ppm), VOCs (0–0.5 ppm) |
| Meteorological Inputs | Temperature, Relative Humidity, Barometric Pressure, Wind Speed & Direction, Solar Radiation, Rainfall |
| Noise Measurement | 30–100 dB(A) |
| Sampling Method | Pump-aspirated with heated inlet (PM), dual-stage active flow control |
| Detection Limits | PM <1 µg/m³ |
| Accuracy | PM ±(2 µg/m³ + 5% of reading) |
| Operating Temperature | −10 °C to +45 °C |
| Enclosure | IP65 fiberglass housing with aluminum solar radiation shield |
| Power | 100–260 VAC (31.3 W) or 12 VDC (34.3 W) |
| Data Storage | 32 GB SSD (≥5 years at 1-min interval) |
| Connectivity | Wi-Fi, Ethernet, optional 4G HSPA cellular modem |
| Software | Aeroqual Connect (on-device web interface), Aeroqual Cloud (secure encrypted cloud platform) |
| Compliance | Designed for alignment with ISO 12103-1 (aerosol calibration), EN 14625 (O₃ monitoring), EN 14626 (NO₂ monitoring), and US EPA EQOA requirements for near-reference-grade performance |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AEROQUAL Series 500 |
| Sensor Compatibility | Interchangeable modular sensor heads (sold separately) |
| Power | Rechargeable 12 V DC Li-ion battery (2700 mAh, ~8 h runtime) |
| Data Logging | 8,188 total readings (including up to 2,706 temperature/humidity records) |
| Communication | USB (RS-232 via adapter), 0–5 V analog output |
| Environmental Rating | IP20 / NEMA 1 |
| Dimensions | 195 × 122 × 54 mm (with sensor head) |
| Weight | <460 g (<16 oz) |
| Operating Range | 5–45 °C, 0–95 %RH (non-condensing) |
| Certifications | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | AQM 65 |
| Power Supply | 90–264 VAC, 47–63 Hz |
| Operating Temperature | −35 °C to +50 °C |
| Enclosure Rating | IP65 |
| Dimensions (standard) | 1310 × 510 × 290 mm (H×W×D) |
| Weight | ~25 kg |
| Core Computing Platform | Intel Atom N2600, 1.6 GHz, 2 GB RAM, 32 GB SSD, Ubuntu Linux |
| Communication | Wi-Fi, Ethernet (LAN), optional cellular GPRS modem |
| Gas Sampling | 12 V brushless diaphragm pump, PTFE-lined stainless steel inlet |
| Thermal Management | DC compressor (R134a), 12–24 V, 60 W resistive heater |
| Data Transmission | Aeroqual Cloud (encrypted), FTP/email export (optional), SMS/email alerts (optional) |
| Calibration Options | AirCal 1000 (portable), AirCal 8000 (integrated) |
| Certified Sensor Modules | Gill WindSonic (ultrasonic wind), Vaisala WXT536 (weather), Cirrus MK427 Class 1 (noise), Novalynx pyranometer (solar radiation) |
| Measured Gases | O₃ (0–0.5 ppm), NO₂ (0–0.2 ppm), NOₓ (0–0.5 ppm), CO (0–25 ppm), SO₂ (0–10 ppm), H₂S (0–10 ppm), CO₂ (0–2000 ppm), VOC (0–20 ppm) |
| Particulate Matter | PM₁/PM₂.₅/PM₁₀/TSP via optical particle counter (±5 µg/m³ + 15% of reading) and turbidimeter (±2 µg/m³ + 5% of reading) |
| Meteorological Parameters | Wind speed/direction, temperature, relative humidity, barometric pressure, rainfall, solar irradiance |
| Noise Monitoring | 30–100 dB(A), Class 1 accuracy per IEC 61672-1 |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | WS-APM02 |
| Particle Measurement Principle | Optical Particle Counter (OPC) with Right-Angle Laser Scattering |
| Measured Fractions | TSP, PM₁₀, PM₂.₅, PM₁ |
| Mass Concentration Range | PM₁: 0–200 µg/m³, PM₂.₅: 0–2000 µg/m³, PM₁₀: 0–5000 µg/m³, TSP: 0–5000 µg/m³ |
| Detection Limit | <1 µg/m³ |
| Accuracy | ±(5 µg/m³ + 15% of reading) |
| Sample Flow Rate | 1.0 L/min |
| Inlet Length | 36 cm with integrated heating element |
| Output Interfaces | RS-232 (legacy mode), 4× 4–20 mA analog outputs, 2× relay outputs |
| Averaging Intervals | 1 min, 5 min, 10 min, 15 min, 30 min, 1 hr, 2 hr, 4 hr, 8 hr, 12 hr, 24 hr |
| Operating Temperature | −10°C to +50°C |
| Relative Humidity Range | 10–95% RH (non-condensing) |
| Enclosure Rating | IP65 |
| Housing Material | Lockable GRP cabinet with integrated solar radiation shield |
| Dimensions (H×W×D) | 483 × 330 × 187 mm (including radiation shield and mounting bracket) |
| Weight | <13 kg |
| Meteorological Parameters | Wind speed & direction, air temperature, relative humidity, barometric pressure, precipitation, global solar radiation, photosynthetically active radiation (PAR) |
| Power Options | 100–260 V AC (15 W / 24 W) or 12 V DC (15 W / 24 W) |
| Data Storage | High-capacity internal memory |
| Communication | Optional wireless telemetry module (e.g., LTE/4G, LoRaWAN) |
| Compliance | Designed for continuous ambient air quality monitoring in accordance with ISO 12103-1 (test dust), EPA EQOA-PM-01 guidance, and EU Directive 2008/50/EC Annex III technical requirements for PM monitoring |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | DusT Sentry |
| Particle Measurement Principle | Optical Particle Counting (OPC) via Right-Angle Laser Scattering |
| Measured Parameters | TSP, PM₁₀, PM₂.₅, PM₁ |
| Optional Integrated Gases | VOCs, NO₂, O₃ |
| Sampling Flow Rate | 1.0 LPM |
| Detection Limit | <1 µg/m³ |
| Accuracy | ±(5 µg/m³ + 15% of reading) |
| Resolution | 0.1 µg/m³ |
| Data Logging Interval | 1 min to 24 h |
| Operating Temperature | −10 °C to +45 °C |
| Power Supply | 100–260 VAC (24.7 W) or 12 VDC (27.2 W) |
| Enclosure | IP65-rated GRP cabinet with aluminum solar radiation shield |
| Weight | <13 kg |
| Dimensions | 483 H × 330 W × 187 D mm (incl. shield & mounting hardware) |
| Data Storage | 32 GB SSD (≥5 years at 1-min intervals) |
| Certified | MCERTS-approved for precision and repeatability |
| Comms | Wi-Fi, Ethernet, optional HSPA 3G cellular modem |
| Software | Aeroqual Connect (browser-based local configuration), Aeroqual Cloud (secure encrypted remote data access, diagnostics, calibration logging, alarm management) |
| Brand | Aeroqual |
|---|---|
| Origin | New Zealand |
| Model | Series 500 |
| Instrument Type | Portable |
| Detectable Gases | CO, CO₂, NO, H₂S, O₃ |
| Response Time | ≤120 s (T90, gas-dependent) |
| Measurement Accuracy | ±0.5–10% of reading + offset (gas- and sensor-specific) |
| Measurement Range | 0.001–10,000 ppm (gas-dependent) |
| Data Logging Capacity | 8,188 records (including 2,706 temperature/humidity entries) |
| Power | Rechargeable 12 V DC Li-ion battery (2.7 Ah), ~8 h operation |
| Dimensions (with sensor head) | 195 × 122 × 54 mm |
| Weight (with battery & sensor head) | <460 g |
| IP Rating | IP20 / NEMA 1 |
| Operating Environment | 5–45 °C, 0–95% RH (non-condensing) |
| Compliance | FCC Part 15, EN 50082-1:1997, EN 50081-1:1992 |
| Brand | Haglof Inc. |
|---|---|
| Origin | Sweden |
| Model | Postex |
| Dimensions | 93 × 63 × 72 mm |
| Weight (instrument) | 243 g |
| Weight (tripod assembly) | 4.85 kg |
| Ultrasonic Range | ≥30 m (with 360° adapter: ≥20 m) |
| Laser Range | 0.46–700 m |
| Laser Accuracy | ±4 cm |
| Angular Accuracy | ±0.1° |
| Angular Resolution | 0.1° |
| Distance Resolution (ultrasonic) | 0.01 m |
| Distance Resolution (laser, DME mode) | 0.01 m |
| Operating Temperature | −20 °C to +45 °C |
| IP Rating | IP67 / NEMA 6 |
| Laser Class | IEC 60825-1:2001 Class 1M, FDA 21 CFR Part 1040.10 Class 1 |
| Battery | Internal 3.7 V rechargeable Li-ion (~9,000 measurements per charge |
| Interface | USB Mini-B, Bluetooth SPP (PIN: 1234), IR |
| Data Output Format | NMEA or ASCII |
| Tripod Arm Extension | Up to 125 cm from center |
| Reflector Beacon (A/B/C) | Ø70 mm, 85 g each, 1.5 V AA alkaline, max. 9 mW |
| Brand | UGT |
|---|---|
| Origin | Germany |
| Model | FOG II |
| Measurement Principle | Pressure-based CO₂ evolution from HCl–CaCO₃ reaction |
| Display | Backlit LCD with membrane keypad |
| Power | 3×AA alkaline or rechargeable batteries |
| Measurement Range | 0–100% CaCO₃ (w/w) |
| Accuracy | ±0.5% CaCO₃ |
| Resolution | 0.1% CaCO₃ |
| Linearity (r²) | ≥0.999 |
| Temperature Compensation | Built-in sensor, 5–50 °C |
| Sample Mass | 0.5–5 g |
| Analysis Time | ~30 s per sample |
| Data Storage | Last 50 measurements |
| Ingress Protection | IP65 |
| Dimensions (L×W×H) | 200×94×39 mm |
| Weight | 350 g |
| Housing Material | UL 94 HB-rated ABS |
| Keypad | Polyester (PET) membrane |
| Display Coating | Scratch-resistant resin |
| Standard Kit | Analyzer unit, glass reaction vials, 100 mL sampling bottle, silicone tubing, precision micro-scale (0.01 g resolution), batteries, operation manual, and rugged carry case |
| [Brand | DiJiang |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DJ-212X |
| Pricing | Upon Request |
| Data Logger | 8 single-ended analog inputs, 4 pulse inputs, 3 voltage excitation terminals, 12 x 12V switch outputs, 8 SDI-12 ports, 4 RS485/RS232 interfaces |
| Analog Resolution | 12-bit (0–5000 mV range, 1.47 mV basic resolution, ±(0.1% of reading + 2 LSB) accuracy from −20 °C to +40 °C) |
| Internal Storage | 32 MB (supports ≥64,384 records at 1-hr interval ≈ 7.3 years) |
| Power | 11–24 V DC (solar + 12 V / 65 Ah sealed lead-acid battery) |
| Sleep current | 0.24 mA, Measurement current: 12 mA (excl. sensors), LTE transmission avg.: 40 mA |
| Communication | Modbus RTU over RS485/RS232, SDI-12, LTE CAT1 (embedded SIM), GPS + barometric pressure + board temperature sensors onboard |
| Enclosure | IP65, 350 × 250 × 120 mm, 4.5 kg |
| Inner Chamber | SUS304 stainless steel, diameters φ300–φ900 mm × heights 300–900 mm |
| Outer Chamber | Food-grade PP polymer, diameters 500–1100 mm × heights 450–1050 mm |
| Load Cell | Alloy aluminum or stainless steel platform |
| Drainage Sensor | Tipping bucket with reed switch, 0.2 mm (4.28 mL) resolution, ±4% accuracy |
| Soil Tri-sensor | Volumetric water content 0.88–81.88%, temperature −40 to +80 °C, EC 0–23,000 µS/cm, IP68 |
| Water Level Sensor | 0–1 m range, RS485 output, 316L stainless steel housing, −40 to +60 °C medium temp |
| Drainage Flow Rate | 1800 mL/min @ 12 V |
| Tripod | 2 m height, full SUS304 construction, 42 mm OD mounting pole] |
| Brand | DAIKI |
|---|---|
| Origin | Japan |
| Model | DIK-4201 |
| Infiltration Cylinder Dimensions (Large) | Ø300 mm × H350 mm, 6 kg |
| (Medium) | Ø290 mm × H350 mm, 5.5 kg |
| (Small) | Ø280 mm × H350 mm, 5 kg |
| Control Panel | 320 mm × 320 mm × 9 mm, 42 kg total system weight |
| Configuration | One large + one medium + one small infiltration cylinder, power adapter, control panel |
| Brand | Dianjiangkeji |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DJ-2132 |
| Pricing | Upon Request |
| Brand | Delta-T Devices |
|---|---|
| Origin | United Kingdom |
| Model | AP4 |
| Measurement Principle | Steady-state diffusion-based porometry |
| Weight | 3.0 kg (main unit), 130 g (sensor head) |
| Operating Time | Up to 20 h on internal rechargeable battery |
| Data Storage | 1500 readings |
| Interface | RS232 (9600 baud) |
| Compliance | Designed for GLP-aligned field and lab use |
| Software | Windows-compatible CSV export utility |
| Brand | Hansatech (distributed by SUSS, Germany) |
|---|---|
| Origin | United Kingdom |
| Model | M-PEA-1 |
| Power Supply | 12 V DC, 1 A |
| Operating Temperature | 0–40 °C |
| Dimensions | 230 × 190 × 85 mm |
| Weight | 1.4 kg |
| Data Interface | USB 2.0 |
| Sampling Rate | 10 µs |
| A/D Resolution | 16-bit |
| Actinic Light Source | High-intensity red LED (peak 625 nm, FWHM 20 nm), up to 5000 µmol m⁻² s⁻¹ |
| Far-Red Light Source | High-brightness LED with long-pass filter, >1000 µmol m⁻² s⁻¹ |
| P700⁺ Measurement | Modulated 820 nm LED (1–100% intensity, 1% step) |
| Fluorescence Detection | Low-noise, fast-response PIN photodiode with 730 nm ±15 nm bandpass filter |
| P700⁺ Detection | Low-noise, fast-response PIN photodiode with dedicated bandpass filtering |
| Optical Sealing | Quartz-glass encapsulation for dust, moisture, and contamination resistance |
| Brand | Delta-T Devices |
|---|---|
| Origin | United Kingdom |
| Model | PR2-4 |
| Measurement Principle | Frequency Domain Reflectometry (FDR) |
| Probe Depths | 10, 20, 30, and 40 cm |
| Output | Four analog voltage signals (0–1 V corresponding to 0–60 % vol) |
| Volumetric Water Content Range | 0–100 % vol (optimal accuracy: 0–40 % vol) |
| Accuracy | ±4 % vol (0–+40 °C, soil-specific calibration) or ±6 % vol (0–+40 °C, generic calibration) |
| Salinity Tolerance | 50–400 mS/m (pore water electrical conductivity) |
| Sensor Sensitivity Volume | Cylindrical zone of 10 cm diameter × 5 cm height (95 % contribution to reading) |
| Operating Temperature | –20 to +70 °C (optimal accuracy: 0–+40 °C) |
| IP Rating | IP67 (probe), IP52 (HH2 meter) |
| Power Supply | 5.5–15 V DC |
| Current Draw | <80 mA |
| Response Time | 1 s |
| Cable | Shielded 9-conductor, standard 1.5 m with M12 IP68 connector |
| Probe Material | Polycarbonate housing with stainless steel tip |
| Probe Dimensions | 750 mm length × 25.4 mm diameter |
| Probe Weight | 0.6 kg |
| HH2 Meter Display | 16×2 character LCD |
| HH2 Memory Capacity | 166–782 readings |
| HH2 Battery Life | ~4500 measurements on one 9 V alkaline cell |
| EMC Compliance | Meets EU EMC Directive 2014/30/EU |