| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | DTM-II |
| Price | USD 7,000 (FOB) |
| Frequency Range | 100–20 kHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±0.5% |
| Dynamic Elastic Modulus Range | Corresponding to measured resonance frequency |
| Modulus Resolution | 0.05 GPa |
| Modulus Accuracy | ±0.1 GPa |
| System Relative Error | ±0.15% |
| Damping/Internal Friction (Q⁻¹) | 1×10⁻⁵ to 0.1 |
| Test Temperature | Ambient to 1750 °C |
| Shear Modulus Measurement | Yes |
| Poisson’s Ratio Calculation | Yes |
| Data Interface | RS-232/USB (optional) |
| Display Modes | Resonance Frequency, Dynamic Elastic Modulus, Spectral Plot, Damping Index |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (PRC) |
| Model | GTM- |
| Price Range | USD 1,400 – 2,800 |
| Load Capacity Options | 0–5 kN, 0–10 kN, 0–20 kN, 0–50 kN |
| Measurement Accuracy | ±0.15% FS (Load), ±0.5% FS (Deformation) |
| Deformation Range | ±5 mm |
| Displacement Rate | 0–1 mm/min (adjustable) |
| Temperature Capability | GTM-1 — Ambient only |
| Sample Dimension Tolerance | Parallelism ≤0.02 mm, Perpendicularity ≤0.02 mm, Surface Roughness Rz ≤1.60 µm |
| Strain Gauge Length Limits | ≤1 mm (3-point bend), ≤5 mm (4-point bend) |
| Compliance Standards | GB/T 10700–2006, GB/T 6569, GB/T 1182, GB/T 1031 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | HY-7721C |
| Price | USD 1,760 (FOB Tianjin) |
| Standard Compliance | GB/T 6670–2008, ASTM D3574, ISO 8307 |
| Drop Height (Method A) | 500 ± 0.5 mm |
| Drop Height (Method B) | 460 ± 0.5 mm |
| Ball Mass (Method A) | 16.8 ± 1.5 g |
| Ball Mass (Method B) | 16.3 g |
| Ball Diameter | 16.0 ± 0.5 mm |
| Sample Dimensions | 100 × 100 × 50 mm (L × W × H) |
| Rebound Accuracy | < ±1.5% |
| Measurement Output | Average rebound height, average rebound percentage, statistical summary per test set |
| Control System | Industrial PLC + 7-inch TFT touch HMI (Chinese UI) |
| Data Output | Integrated thermal micro-printer (desktop type) |
| Sensor | High-speed optical distance sensor (non-contact, 1 kHz sampling) |
| Brand | IMCE |
|---|---|
| Origin | Belgium |
| Model | HT1600-DS |
| Sample Capacity | 2 simultaneous specimens |
| Operating Temperature Range | Up to 1600 °C |
| Optional Vertical Dilatometer Integration | Yes |
| Compliance | ASTM E1876, ISO 12680, DIN 51045 |
| Brand | IMCE |
|---|---|
| Model | HTVP1600/1700C (HT1050/1600/1700) |
| Operating Temperature Range | Ambient to 1600 °C / 1700 °C |
| Temperature Stability | ±1 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Resonance Frequency Range | 10 Hz–150 kHz (±0.5 Hz) |
| Damping/Internal Friction Measurement Range | 1×10⁻⁵–0.1 |
| Elastic Modulus Accuracy | <0.1% at RT, <5% at elevated temperature |
| Elastic Modulus Range | 10 MPa–880 GPa |
| Shear Modulus & Poisson’s Ratio | Calculated from resonance spectra |
| Atmosphere Control | Inert, oxidizing, reducing, vacuum-compatible |
| Detection Method | Non-contact laser Doppler vibrometry |
| Compliance | ASTM E1876, ASTM C1259 |
| Brand | IMCE |
|---|---|
| Model | HTVP1600C |
| Measurement Principle | Resonant Frequency Method |
| Frequency Range | 1–100 kHz |
| Damping Factor (tan δ) | 1×10⁻⁵ to 0.1 |
| Temperature Range | Ambient to 1600 °C |
| Atmosphere Control | Yes |
| Compliance | ASTM E1876-99 |
| Output Parameters | Young’s Modulus, Shear Modulus, Poisson’s Ratio, Internal Friction (Q⁻¹) |
| Brand | IMCE |
|---|---|
| Model | HTVP650C |
| Measurement Principle | Impulse Excitation Technique (IET) / Resonance Frequency Analysis |
| Frequency Range | 1–100 kHz |
| Elastic Modulus Accuracy | < ±0.1% |
| Repeatability | < ±0.2% |
| Damping Resolution | down to 1×10⁻⁵ |
| Sample Dimensions | Length 20–300 mm, Width 2–130 mm |
| Maximum Operating Temperature | 650 °C (upgradable to 1100 °C) |
| Compliance | ASTM C1259, ASTM E1187 |
| Software | Integrated IET data acquisition & analysis suite with temperature correlation module |
| Excitation | Automated electromagnetic impulse system |
| Data Output | Young’s modulus (E), Shear modulus (G), Poisson’s ratio (ν), Resonant frequencies (f₁, f₂, …), Internal friction (Q⁻¹) |
| Brand | IMCE |
|---|---|
| Model | RFDA MF Professional |
| Origin | Belgium |
| Application | Non-destructive dynamic mechanical characterization of ceramics, metals, and advanced materials |
| Temperature Range | Ambient to 1750 °C |
| Atmosphere Control | Yes |
| Damping Measurement Range | 1×10⁻⁵ to 0.1 (dimensionless) |
| Measured Parameters | Resonant frequency, elastic modulus (E), shear modulus (G), Poisson’s ratio (ν), internal damping (Q⁻¹ or tan δ) |
| Compliance | ASTM E1876, ISO 12680, DIN 51045-1, applicable to GLP/GMP environments with audit trail enabled in RFDA MF Software |
| Brand | Labthink |
|---|---|
| Model | XLW-PC |
| Type | Universal Tensile & Mechanical Property Tester for Flexible Packaging Materials |
| Accuracy Class | 0.5 |
| Force Capacity Options | 50 N, 100 N, 250 N (standard), 500 N (default), 750 N, 1000 N (customizable) |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Maximum Travel | 1000 mm |
| Specimen Width | 30 mm (standard grip), 50 mm (optional) |
| Dimensions | 450 × 450 × 1410 mm (L×W×H) |
| Weight | 68 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Compliance | ISO 37, ASTM D882, ASTM D1938, ASTM D3330, ASTM F88, ASTM F904, GB/T 1040.1–1040.5, GB/T 4850, GB/T 12914, GB/T 16578.1, JIS P8113, QB/T 2358, QB/T 1130 |
| Brand | Labthink |
|---|---|
| Model | XLW(PC) |
| Application | Tensile Strength, Elongation at Break, and Elastic Modulus Testing for Flexible Packaging Films and Soft Materials |
| Standards Compliance | ISO 37, ASTM D882, GB/T 1040.1–1040.5, GB/T 8808, ASTM F88, JIS P8113 |
| Load Capacity | 500 N (standard) |
| optional ranges | 50 N, 100 N, 250 N, 750 N, 1000 N |
| Accuracy Class | 0.5 |
| Test Speeds | 50, 100, 150, 200, 250, 300, 500 mm/min |
| Maximum Travel | 1000 mm |
| Sample Width | 30 mm (standard clamp), 50 mm (optional) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Dimensions (L×W×H) | 450 × 450 × 1410 mm |
| Net Weight | 68 kg |
| Software | Lystem™ Laboratory Data Sharing System, GLP/GMP-compliant audit trail, multi-sample statistical analysis, curve overlay, historical data comparison |
| Brand | IMCE |
|---|---|
| Origin | Belgium |
| Model | LT80 |
| Operating Temperature Range | 77 K to 473 K (Liquid Nitrogen–Free) |
| Cooling Method | Closed-Cycle Mechanical Cryocooler |
| Price | €100,000 |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GTM-1 / GTM-2 |
| Load Capacity Options | 0–5 kN, 0–10 kN, 0–20 kN, 0–50 kN |
| Measurement Accuracy (Load) | ±0.15% FS |
| Deflection Range | ±5 mm |
| Deflection Accuracy | ±0.5% FS |
| Crosshead Speed | 0–1 mm/min (adjustable) |
| Temperature Capability | GTM-1 — Ambient only |
| Sample Dimension Tolerance per GB/T 1182 & GB/T 1031 | Parallelism ≤0.02 mm, Perpendicularity ≤0.02 mm, Surface Roughness Rz ≤1.60 µm |
| Compliance Standards | GB 10700–2006, GB/T 6569, GB/T 1182, GB/T 1031 |