| Brand | Xuxin Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | ST-1535C |
| Price Range | USD 700 – 7,000 |
| Principle | Microcoulometric Titration |
| Standards Compliance | GB/T 18612-2011, GB/T 22904, SY/T 7329-2016, Q/SH1020 2093-2016 |
| Bias Voltage Range | 0–500 mV (continuously adjustable) |
| Detection Method | Coulometric |
| Measurement Range | 0.1–10,000 mg/L Cl (dilutable for high concentration |
| Detection Limit | 0.1 mg/L (as Cl) |
| Sample Types | Liquid, solid, and gaseous (with compatible autosamplers) |
| Temperature Control Range | Ambient to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Carrier Gases | Industrial-grade N₂ and O₂ |
| Operating Environment | 5–45 °C, 10–80% RH |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 2500 W |
| Precision (RSD) | ≤2% (at 100 mg/L, 5 µL injection), ≤3% (at 10 mg/L), ≤8% (at 1 mg/L), ≤20% (at 0.1 mg/L) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | i-301 |
| Portability | Portable |
| Intended Use | Laboratory |
| Conductivity Range | 0.000 µS/cm to 200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–80 ppt |
| Temperature Range | −5 to 55 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.1 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color TFT capacitive touchscreen |
| Calibration | Auto-identification of standard solutions |
| cell constant options | 0.01, 0.1, and 1.0 cm⁻¹ |
| Compliance | IP54 ingress protection |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-211 |
| Form Factor | Benchtop |
| Intended Use | Laboratory |
| Conductivity Range | 0.01 μS/cm to 100 mS/cm |
| TDS Range | 0.01 mg/L to 100 g/L |
| Resistivity Range | 0.01 Ω·cm to 100 MΩ·cm |
| Salinity Range | 0.01 ‰ to 100 ‰ |
| Temperature Range | 0–100 °C |
| Accuracy | ±1% FS (conductivity), ±0.5 °C (temperature) |
| Minimum Resolution | 0.01 μS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color capacitive touchscreen |
| Calibration | Auto-recognition of 8 standard solutions (including ISO/ASTM-compliant KCl standards), single-point or multi-point calibration |
| Compensation | Automatic and manual temperature compensation (ATC/MTT) |
| Data Management | Statistical analysis (mean, SD, min/max), audit-trail-capable storage, print-ready export, GLP/GMP-compliant metadata tagging |
| Protection Rating | IP54 |
| Electrode Compatibility | Standard 1.0 cm⁻¹ cell (optional 0.1 or 0.01 cm⁻¹ cells for low-conductivity samples) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | L-311 |
| Portability | Portable |
| Intended Use | Laboratory |
| Conductivity Range | 0.000 µS/cm to 200 mS/cm |
| TDS Range | 0 to 100 g/L |
| Resistivity Range | 0 to 10 MΩ·cm |
| Salinity Range | 0 to 80 ppt |
| Temperature Range | −5 to 55 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.1 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm (conductivity), 0.1 °C (temperature) |
| Display | 7-inch color TFT capacitive touchscreen |
| Compliance | IP54 |
| Calibration | Auto-recognition of 8 standard solutions (including ISO and GB standards), single-point or multi-point calibration supported |
| Electrode Constant Options | 0.01, 0.1, 1.0 cm⁻¹ (1.0 cm⁻¹ electrode supplied) |
| Data Management | Statistical analysis (min/max/avg/stdev), storage ≥1000 data points, print-ready output, audit-trail-capable logging, firmware upgradability, power-failure recovery, factory reset |
| Temperature Compensation | Automatic (linear & non-linear NIST/ISO models) and manual modes |
| Language Support | English & Chinese UI |
| Environmental Rating | IP54 |
| Brand | YSI |
|---|---|
| Origin | USA |
| Model | EC300A |
| Portability | Portable |
| Application Environment | Laboratory & Field |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–10 MΩ·cm |
| Salinity Range | 0–70 ppt |
| Temperature Range | −10°C to +90°C |
| Conductivity Accuracy | ±1% FS (full-scale) or ±1% reading + offset per range |
| Temperature Accuracy | ±0.2°C or ±0.4% of range (whichever is greater) |
| Conductivity Resolution | 0.01 μS/cm (lowest range), 0.1 mS/cm (highest range) |
| Temperature Resolution | 0.1°C |
| Probe Type | Stable 4-electrode conductivity cell |
| Waterproof Rating | IP65 (instrument body) |
| Power Supply | One 9V alkaline battery (≈150 h typical life) |
| Dimensions | 18.6 × 7.0 × 3.7 cm |
| Weight | 430 g (with battery) |
| Warranty | 1 year limited warranty on instrument, probe, and cable |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST109B-HP880 |
| Measuring Range | pH 0–14 |
| Accuracy | ±0.1 pH |
| Temperature Compensation | 0–99.9 °C (25 °C reference, automatic) |
| Output Signals | 4–20 mA (2-wire), RS485 (Modbus RTU) |
| Power Supply | 24 VDC (wide-input tolerant) |
| Protection Rating | IP65 |
| Response Time | <30 s |
| Stability | ±0.02 pH/24 h |
| Brand | YST (Dalian Yist) |
|---|---|
| Origin | Liaoning, China |
| Model | YST109B-HP880 |
| pH Range | 0–14 |
| ORP Range | −2000 to +2000 mV |
| pH Accuracy | ±0.02 |
| ORP Accuracy | ±5 mV |
| Temperature Compensation | 0–99.9 °C (reference 25 °C |
| Output Signals | 4–20 mA (2-wire), RS485 (Modbus RTU) |
| Power Supply | 24 VDC (wide-range, solar-compatible) |
| Media Compatibility | Aqueous solutions, weakly corrosive liquids (pH 2–12), suspensions |
| Drift Stability | ±0.02 pH/24 h |
| Enclosure Rating | IP65 |
| Response Time | <30 s |
| ADC Resolution | 24-bit |
| Calibration Modes | Manual & Automatic (single-/two-point) |
| Data Logging | 30-day local history storage |
| Electrode Options | Glass, antimony, or refillable gel-filled pH electrodes |
| Brand | YST (Dalian Yist) |
|---|---|
| Model | YST109B-HP880 |
| Measurement Range | pH 0.00–14.00 |
| Accuracy | ±0.1 pH |
| Resolution | 0.01 pH |
| Temperature Compensation | 0–60 °C (Automatic) |
| Power Supply | DC 12 V |
| Power Consumption | ≤1 W |
| Protection Rating | IP65 |
| Operating Temperature | −10 °C to 50 °C |
| Communication Protocol | RS485 Modbus-RTU |
| Brand | YST (Dalian Yist Instruments) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measurement Range | -1999 to +1999 mV |
| Accuracy | ±2 mV @ 25 °C |
| Response Time | ≤10 s (to 90% of final value) |
| Temperature Compensation | Automatic, 0–100 °C |
| Output Signals | Isolated 4–20 mA + RS485 digital interface |
| Sensor IP Rating | IP68 |
| Transmitter IP Rating | IP65 |
| Operating Ambient | 0–60 °C, ≤90% RH (non-condensing, away from strong magnetic fields) |
| Power Supply | 220 V ±10%, 50 Hz |
| Installation Type | Submersible (tank/pipeline) |
| Brand | YSTorp (Dalian Yistorp) |
|---|---|
| Origin | Liaoning, China |
| Model | YST209B-RP880 |
| Measuring Range | ORP –1999 to +1999 mV (0.1 mV resolution) |
| Accuracy | ±1 mV (ORP), ±0.5 °C (Temperature, 0–60.0 °C) |
| Automatic Temperature Compensation (ATC) | 0.0–120.0 °C (reference 25 °C) |
| Output | 4–20 mA isolated analog output |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Enclosure Rating | IP65 |
| Dimensions | 96 × 96 × 110 mm (panel cutout: 92 × 92 mm) |
| Installation Options | Flow-through, submersible, flanged, pipe-mounted, sidewall-mounted |
| Operating Environment | 0–60 °C ambient, RH <85 % non-condensing |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | CIMPS-Pro Zennium |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A, ±10 A |
| Current Accuracy | 0.02% of reading |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V, ±20 V |
| AC Impedance Frequency Range | 10 µHz – 8 MHz |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7 |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Accuracy | < 0.0025% |
| Potential Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (2 × 10⁻¹⁸ A) |
| Small-Signal Rise Time | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7c |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Scan Range | ±14 V |
| Potentiostatic Range | ±5 V / ±14 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Input Impedance | >10 TΩ (HIZ option: 1000 TΩ) |
| AC Voltage Perturbation | 0–6 V (24-bit resolution) |
| AC Current Perturbation | 0–2 A (24-bit, 12 ranges) |
| Grounding Modes | Grounded & Floating |
| IR Compensation Range | 0–10 MΩ |
| Bandwidth | DC–6 MHz |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | IM7x |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| EIS Frequency Range | 10 µHz – 12 MHz |
| Potentiostat Bandwidth | DC – 15 MHz |
| ADC Resolution | 32 bit |
| Input Impedance | >10 TΩ |
| Applied Potential Range | ±15 V |
| Cell Voltage Range | ±32 V |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Current Resolution | ±2 aA (±2 × 10⁻¹⁸ A) |
| Output Current Accuracy | ±0.025% of reading ± 0.01% of FS (≥3 µA to 300 mA) |
| Rise Time (Small Signal) | 150 ns – 200 µs (5 auto-ranging steps) |
| IR Compensation | Real-time, adaptive EIS-based |
| Grounding Mode | Switchable floating/grounded |
| Communication Interface | Gigabit Ethernet |
| Internal Storage | 40 GB SSD |
| Software Platform | Zahner Lab (Windows 11, Linux, macOS compatible) |
| API Support | Python/C++ SDK included |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium Pro |
| Current Range | ±3 A |
| Current Resolution | ±2 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32 bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 0.0025%, 10,000 steps/decade |
| Impedance Measurement Range | 10 µΩ to 100 GΩ (depending on probe configuration) |
| IR Compensation | Real-time, adaptive |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA), ±0.2% of reading + ±0.1% of full scale (100 mA–3 A), ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| Compliance Voltage | ±32 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA (32-bit DAC/ADC) |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic EIS-based compensation |
| Grounding Mode | Switchable floating/grounded configuration |
| ADC/DAC Resolution | 32-bit HDP (High Dynamic Precision) architecture |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA) / ±0.2% of reading + ±0.1% of full scale (100 mA–3 A) / ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±2 aA (±2×10⁻¹⁸ A) |
| ADC Resolution | 32 bit |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic |
| Grounding Mode | Switchable floating/grounded |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% (100 mΩ–10 MΩ), ±2% (1 mΩ–100 mΩ or 10 MΩ–10 GΩ) |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Switchable Floating Ground |
| IR Compensation | Real-time, automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Current Resolution | 2 × 10⁻¹⁸ A |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% @ 100 mΩ–10 MΩ |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Floating (for high-isolation applications, e.g., autoclaves, buried pipelines) |
| IR Compensation | Real-time automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| Software | Thales XT (real-time control, multi-channel visualization, offline analysis via Zahner Analysis) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | ZenniumPro |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Resolution | ±5 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| IR Compensation | Real-time, automatic |
| Grounding Modes | Switchable floating/grounded |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Impedance Accuracy | 1 mΩ–10 GΩ (±2%), 100 mΩ–10 MΩ (±0.2%) in POT mode |
| Software | Thales XT + Zahner Analysis (EIS fitting, CIMPS, Z-HIT, NFRA) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-FA |
| Price | Upon Request |
| Potential Range | −1000 to +1000 mV |
| Reference Electrode Input Impedance | ≥1 × 10¹² Ω |
| Detection Sensitivity | ≤0.01 µg/kg |
| Input Bias Current | Available upon manufacturer consultation |
| Potential Increment | Available upon manufacturer consultation |
| Scan Rate | Available upon manufacturer consultation |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-S1 |
| Pricing | Available Upon Request |
| Detection Principle | Isothermal Nucleic Acid Amplification with Real-Time Fluorescence Monitoring |
| Temperature Control Accuracy | ±0.5 °C |
| Fluorescence Excitation/Emission | Dual-Channel (FAM/HEX or equivalent) |
| Sample Throughput | 1–14 samples per run, up to 5 targets simultaneously |
| Detection Time | As low as 20 min for preliminary positive call |
| Data Storage | On-device SD card + cloud synchronization (AES-256 encrypted) |
| Compliance | Designed in alignment with ISO/IEC 17025 laboratory competence requirements and GB/T 27403–2019 (China National Standard for Molecular Testing in Food Safety Laboratories) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | RTS2-InSitu |
| Pricing | Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | STS Series |
| Pricing | Available Upon Request |