| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD300 Standard |
| Portability | Portable |
| Conductivity Range | 0.00 μS/cm to 200.0 mS/cm (5-range auto-ranging) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 to 110 °C |
| Accuracy | ±1.0% FS (conductivity), ±0.5 °C (temperature) |
| Resolution | 0.01 μS/cm (min), 0.1 °C (temperature) |
| Temperature Compensation | Automatic/manual (0–50.0 °C), selectable reference temp (15, 20, 25 °C) |
| Calibration | 1–4 point, with built-in calibration guidance and validation check |
| Data Storage | 100 sets (manual & auto), GLP-compliant |
| Interface | USB |
| IP Rating | IP57 |
| Display | 68 × 53 mm LCD with white backlight and real-time clock |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Basic |
| Form Factor | Benchtop |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS |
| Minimum Resolution | 0.1 μS/cm |
| Calibration | 1–3 point auto-calibration with guidance & verification |
| Electrode Constants Supported | K = 0.1, 1, 10 |
| Temp Compensation | Auto/manual (0–50 °C) |
| Data Storage | 50 manual entries with min/max tracking |
| Display | 80 × 58 mm LCD, large-font |
| IP Rating | IP54 |
| Compliance | CE-marked for laboratory and industrial use |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Educational |
| Form Factor | Benchtop |
| Conductivity Range | 0–200 mS/cm (with sub-ranges: 0–200 μS/cm, 200–2000 μS/cm, 2.00–20.00 mS/cm, 20.0–200.0 mS/cm) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS (conductivity), ±0.5 °C (temperature) |
| Minimum Resolution | 0.1 μS/cm |
| Temperature Compensation | Automatic/manual (0–50 °C) |
| Electrode Constants Supported | K = 0.1, 1.0, 10.0 cm⁻¹ |
| Calibration | 1–3 point auto-calibration with built-in guidance and validation |
| Standard Solution Recognition | CH & USA series (8 total) |
| Data Storage | 50 manual entries with min/max tracking |
| Display | 80 × 58 mm LCD, large-font interface |
| IP Rating | IP54 |
| Compliance | Designed for GLP-compliant educational and industrial QA/QC workflows |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD400 Standard |
| Form Factor | Benchtop |
| Measurement Parameters | Single-parameter (Conductivity) |
| Conductivity Range | 0–200 mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–100 °C |
| Accuracy | ±1.0% FS |
| Minimum Resolution | 0.1 µS/cm |
| Calibration | 1–3 point auto-calibration with guidance and validation |
| Electrode Constants Supported | K = 0.1, 1.0, 10.0 cm⁻¹ |
| Temp. Compensation | Automatic/manual (0–50 °C), selectable °C/°F |
| Display | 80 × 58 mm backlit LCD with large-font digits |
| Data Storage | 200 sets with min/max tracking |
| Interface | RS-232 with PC communication software |
| Ingress Protection | IP54 |
| Compliance | Designed for GLP-compliant laboratory and industrial process monitoring environments |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD510 Standard |
| Form Factor | Benchtop |
| Conductivity Range | 0.00 μS/cm to 2000 mS/cm (6 sub-ranges) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.4 °C (temperature) |
| Minimum Resolution | 0.01 μS/cm |
| Temperature Compensation | Automatic/manual (0–50.0 °C), selectable β coefficient |
| Electrode Constant Selection | Yes |
| Data Storage | 500 sets (manual/auto), GLP-compliant |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight, time stamping |
| Calibration | 1–4 point, with CH/USA standard sets (8 preloaded) and custom solution support |
| Special Modes | Ultra-pure water stabilization, auto-endpoint hold, factory reset |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | CD510 Professional |
| Form Factor | Benchtop |
| Conductivity Range | 0.00 µS/cm to 2000 mS/cm (6 auto-ranging segments) |
| TDS Range | 0–100 g/L |
| Resistivity Range | 0–100 MΩ·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | −10 °C to 110 °C |
| Accuracy | ±0.5% FS (conductivity), ±0.4 °C (temperature) |
| Minimum Resolution | 0.01 µS/cm |
| Temp Compensation | Automatic/manual (0–50.0 °C), selectable β coefficient |
| Electrode Constant Selection | Yes |
| Data Storage | 500 entries (manual/automatic), GLP-compliant |
| Interface | USB |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight, time stamping |
| Calibration | 1–4 point, supports CH/USA standards (8 preloaded + custom solutions) |
| Special Modes | Ultra-pure water stabilization, auto-endpoint hold, factory reset |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | PC5200 |
| Form Factor | Benchtop |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Conductivity Range | 0.00 μS/cm to 2000 mS/cm (6 sub-ranges) |
| Conductivity Resolution | 0.01/0.1/1 μS/cm |
| Conductivity Accuracy | ±0.5% FS |
| Resistivity Range | 0 to 100 MΩ·cm |
| TDS Range | 0 to 100 g/L |
| Salinity Range | 0 to 100 ppt |
| Temperature Range | −10 to 100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Compensation | Automatic or manual (0–50.0 °C) |
| Electrode Constant Selection | Yes |
| Temp. Coefficient Selection | Yes |
| Data Storage | 1000 sets (manual & auto) |
| Interface | USB |
| Compliance | GLP-compliant data management |
| IP Rating | IP54 |
| Display | 90 × 68 mm LCD with white backlight and time stamp |
| Brand | Alalis |
|---|---|
| Model | pH300 Standard |
| Type | Portable pH Meter |
| Measurement Range | -2.00 to 19.99 pH |
| Resolution | 0.01/0.1 pH |
| Accuracy | ±0.01 pH |
| Temperature Compensation | Automatic/Manual (0–100 °C) |
| Calibration Buffers | CH, USA, and NIST series (15 total) |
| Data Storage | 500 groups with USB export |
| Display | 68 × 53 mm LCD with white backlight |
| IP Rating | IP57 |
| Input Connector | 8-pin waterproof socket |
| Compliance | Supports GLP-compliant data logging and audit-ready calibration records |
| Brand | Alalis |
|---|---|
| Model | pH300 Professional |
| Type | Portable pH Meter |
| Measurement Parameters | Dual (pH & mV) |
| pH Range | −2.00 to 19.99 pH |
| pH Resolution | 0.01 / 0.1 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration Buffers | CH, USA, and NIST series (15 total) |
| Calibration Points | 1–5 point auto-calibration with on-screen guidance |
| Temperature Compensation | Automatic or manual (0–100 °C) |
| Data Storage | 500 groups with timestamp, recall, and deletion |
| Connectivity | USB interface with PC software |
| Display | 68 × 53 mm LCD with white backlight and real-time clock |
| Enclosure Rating | IP57 |
| Electrode Interface | 8-pin waterproof socket |
| Default Electrodes | Tri-combination pH electrode + plastic-body ORP electrode |
| Special Modes | High-purity water pH mode, ammonia-added pure water pH mode |
| Power | Auto-off with low-battery indicator |
| Compliance | Designed for GLP-compliant field and lab use |
| Brand | Alalis |
|---|---|
| Model | pH400 Basic |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Calibration Options | 1–3 point, with CH and USA buffer series (6 total standard buffers) |
| Data Storage | 50 manual entries with min/max recall |
| Display | 80 × 58 mm LCD, large-font interface |
| Enclosure Rating | IP54 |
| Default Electrode | Plastic-body tri-combination pH electrode |
| Power | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Model | pH400 Educational |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 |
| pH Resolution | 0.01 / 0.1 |
| pH Accuracy | ±0.01 |
| Temperature Compensation | Automatic or Manual (0–100 °C) |
| Calibration Options | 1–3 point, with CH and USA buffer series (6 standard buffers supported) |
| Display | 80 × 58 mm LCD, large-font interface |
| Data Storage | 50 manual entries with min/max recall |
| IP Rating | IP54 |
| Included Electrode | Rugged composite plastic-body pH electrode |
| Compliance | Designed for GLP-compliant educational and QC environments |
| Brand | Alalis |
|---|---|
| Model | pH400 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (ORP) |
| pH Range | 0.00–14.00 pH |
| pH Resolution | 0.01 / 0.1 pH |
| pH Accuracy | ±0.01 pH |
| mV Range | ±1999 mV |
| mV Resolution | 1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | 0.0–100.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.5 °C |
| Calibration | 1–3 point automatic pH calibration with CH and USA buffer series (6 total standard buffers) |
| Temperature Compensation | Automatic or manual (0–100 °C) |
| Data Storage | 200 sets with min/max recall |
| Interface | RS-232 with PC communication software |
| Display | 80 × 58 mm LCD, large-font, backlit |
| Enclosure Rating | IP54 |
| Default Electrode | Plastic-body tri-combination pH electrode |
| Power | 9 V DC adapter |
| Brand | Alalis |
|---|---|
| Model | pH510 Basic |
| Type | Benchtop pH/mV/Temperature Meter |
| Measurement Principle | Potentiometric pH Determination via Glass Electrode |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH (selectable) |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10.0 to 110.0 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Options | CH, USA, and NIST buffer series (15 total standard buffers) |
| Calibration Points | 1–5 point automatic calibration with guided prompts and electrode diagnostics |
| Temperature Compensation | Automatic or manual (0.0 to 100.0 °C) |
| Display | 90 × 68 mm LCD with white backlight, large-font numeric readout, real-time clock |
| Data Storage | 500 sets (manual + auto-log), min/max tracking |
| GLP Compliance | Timestamped records, electrode ID logging, calibration history retention |
| Connectivity | USB interface with PC software |
| Environmental Rating | IP54 (dust-protected, splash-resistant) |
| Power | 7.9 V DC adapter |
| Electrode | Integrated high-quality plastic-body triple-junction pH electrode with built-in temperature sensor |
| Special Modes | High-purity water pH mode, ammonia-added pure water mode, redox (E<sub>H</sub>) mode, auto-hold endpoint stabilization |
| Brand | Alalis |
|---|---|
| Origin | Shanghai, China |
| Model | pH510 Professional |
| Instrument Type | Benchtop |
| Parameter Types | Dual (pH & mV) |
| pH Measurement Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Calibration Buffers | CH, USA, and NIST series (15 standard solutions + user-defined) |
| Temperature Compensation | Automatic or manual (0–100.0 °C) |
| Data Storage | 500 sets (manual & auto), with min/max tracking |
| Display | 90 × 68 mm LCD with white backlight, time stamp |
| Connectivity | USB interface |
| Enclosure Rating | IP54 |
| Compliance | GLP-compliant data management |
| Brand | Alalis |
|---|---|
| Model | pH510 Standard |
| Type | Benchtop pH Meter |
| Measurement Parameters | pH and mV (Redox) |
| pH Range | −2.000 to 19.999 pH |
| pH Resolution | 0.001 / 0.01 / 0.1 pH |
| pH Accuracy | ±0.002 pH |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.03% FS |
| Temperature Range | −10 to 110 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.4 °C |
| Temperature Compensation | Automatic or Manual (0 to 100.0 °C) |
| Calibration Options | 1–5 point automatic calibration with CH, USA, and NIST buffer series (15 total standard buffers) |
| Special Modes | High-purity water pH mode, ammonia-added pure water pH mode, ORP (E<sub>H</sub>) mode |
| Display | 90 × 68 mm LCD with white backlight, time stamp, large-font readability |
| Data Storage | 500 groups (manual & auto), min/max tracking |
| GLP Compliance | Yes (audit-trail enabled data logging) |
| Connectivity | USB interface with PC software |
| Enclosure Rating | IP54 |
| Power Supply | 9 V DC adapter |
| Key | Brand: All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-300C |
| Form Factor | Benchtop |
| Conductivity Range | 5 × 10⁻⁶ – 1 × 10⁸ mS/cm |
| TDS Range | 0–100 g/L |
| Resistivity Range | 1 × 10⁻⁸ – 2 × 10⁶ Ω·cm |
| Salinity Range | 0–100 ppt |
| Temperature Range | 0–40 °C |
| Accuracy | ±0.05% of reading |
| Minimum Resolution | 0.1 μΩ |
| Voltage Ranges | 2 mV / 20 mV / 200 mV / 2 V (±0.1% rdg, resolution down to 0.1 μV) |
| Current Output | 0–1000 mA DC, adjustable |
| ranges | 1 μA to 1000 mA (±0.2% rdg ±2 digits) |
| Display | 4.3-inch LCD with auto-unit conversion |
| Interface | Dual-language (English/Chinese), PC-compatible via optional software |
| Dimensions | 330 × 340 × 120 mm |
| Power | 220 V ±10%, 50/60 Hz |
| Brand | Hefei Kejing |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | AlN-QCM-50.8mm |
| Price Range | USD 1–999 |
| Substrate | c-plane Sapphire (0001) ±1.0° |
| Diameter | 50.8 mm ±1 mm |
| Thickness | 10–5000 nm |
| Conductivity Type | Semi-Insulating |
| Dislocation Density | XRD FWHM <0002> < 500 arcsec, <10-12> < 1500 arcsec |
| Effective Area | >80% |
| Surface Finish | Single-Side Polished |
| Packaging | Class 1000 Cleanroom, Class 100 Clean Bag or Individual Cassette |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Model | 012613 |
| Electrode Type | Rotating Ring-Disk Electrode (RRDE) |
| Ring Outer Diameter | 7 mm |
| Ring Inner Diameter | 5 mm |
| Disk Diameter | 4 mm |
| Insulator Diameter | 12 mm |
| Total Length | 25 mm |
| Insulator Material | PEEK (resistant to organic solvents) |
| Compatible System | ALS RRDE-3A Rotating Ring-Disk Electrode Instrument |
| Polishing Compatibility | PK-3 Electrode Polishing Kit |
| Electrode Material Options | Multiple disk/ring material combinations available (e.g., Pt, Au, GC, Ag, Ni, Cu, and custom bimetallic configurations) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Model | GC3mm / 013490 |
| Disk Diameter | 3 mm |
| Insulator Diameter | 12 mm |
| Total Length | 25 mm |
| Electrode Material | Interchangeable (e.g., Pt, Au, GC, Ni, Cu, Ag, Glassy Carbon) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Model No. | 013491 |
| Disk Material | Glassy Carbon |
| Disk Diameter | 5 mm |
| Insulator Diameter | 12 mm |
| Total Length | 25 mm |
| Insulation | PTFE (Teflon) Sleeve |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Model 2325 |
| Instrument Type | Portable Electrochemical Workstation |
| Current Range | ±50 mA |
| Current Resolution | 1 × 10⁻⁷ A (100 fA) |
| Potential Accuracy | ±4.0 mV |
| Potentiostatic Range | ±4.0 V |
| Dual-Channel Capability | Yes |
| Impedance Spectroscopy Support | Not Integrated |
| Dimensions | 220 × 150 × 55 mm |
| Weight | 1.2 kg |
| Interface | USB 2.0 |
| Operating System Compatibility | Windows 7/10/11 (32 & 64-bit) |
| Brand | ALS |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RHEK/013597 |
| Instrument Type | Reference Electrode for Electrochemical Measurements |
| Electrolyte Compatibility | 1.2 mol/L HCl (pH ≈ 0, [H⁺] ≈ 1 M) |
| Reference Scale | Defined vs. Standard Hydrogen Electrode (SHE) |
| Brand | ALS (Japan) |
|---|---|
| Model | RRDE-3A |
| Rotation Speed Range | 100–8,000 rpm |
| Gas Purge Control | Programmable ON/OFF timer (up to 9999 s) |
| Display | LCD showing speed, purge duration, model ID, serial number, cumulative motor runtime, maintenance alerts |
| Electrode Compatibility | Standard 7 mm OD coaxial ring-disk electrodes |
| Motor Type | DC servo motor with PI closed-loop speed control |
| Coupling | Insulated elastomeric coupling + PTFE-insulated dual-shaft assembly |
| Cell Interface | Open-cell design with universal potentiostat pin connections |
| Remote Control | TTL/RS-232 interface compatible with ALS Model 2325 bipotentiostat and third-party electrochemical workstations |
| Operating Modes | Manual or computer-controlled (rotation ON/OFF, speed setpoint, purge gas ON/OFF) |
| Origin | USA |
|---|---|
| Distribution Model | Authorized Distributor |
| Import Status | Imported |
| Model | 3010 |
| Conductivity Range | 0.01 µS/cm to 200.0 mS/cm |
| TDS Range | 0.0–80.0 ppt |
| Resistivity Range | 0.01 µS/cm to 200.0 mS/cm (inverted scale) |
| Salinity Range | 0.0–80.0 ppt |
| Temperature Range | −10.0 to 120.0 °C |
| Accuracy | ±0.5% of full scale (FS) for conductivity |
| Minimum Resolution | 0.01 µS/cm (at low range) |
| Electrode Constants Supported | 0.1, 1.0, and 10.0 cm⁻¹ |
| Temperature Compensation | Automatic (NTC 10 kΩ thermistor), user-adjustable α (0.00–4.00 %/°C) and reference temperature (15.0–25.0 °C) |
| TDS Factor | Adjustable (0.30–1.00) |
| Calibration Memory | Yes |
| Power Supply | 9 V alkaline battery (IEC 6LR61) |
| Operating Environment | 0–50 °C, <90% RH |
| Weight | ~260 g |
| Dimensions | 186 × 70 × 37 mm |
| Certifications | CE compliant |
| Brand | AMETEK |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 12 decades, 2 A to 40 pA |
| Current Accuracy | <0.4% (full scale, 20 µA–2 A) |
| Potential Accuracy | ±10 V |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (optional ±20 A) |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Current Resolution | 1.2 fA |
| Input Impedance | >10¹³ Ω |
| Capacitance | <5 pF |
| Slew Rate | >15 V/µs |
| Rise Time | <250 ns |
| Minimum Time Resolution | 20 µs |
| Minimum Potential Step | 2.5 µV |
| Noise | <50 µV RMS (typical) |
| IR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Current Interruption | 16-bit DAC |
| Voltage Output Range | ±100 V |
| Power Amplifier Output | ±100 V / ±2 A |
| Bandwidth | >15 MHz (3 dB) |
| Software | PowerSuite (PowerCV, PowerEIS, PowerPULSE, PowerSTEP, PowerCORR, PowerSINE) |
| Interface | USB |
| Operating System | Windows 98/2000/NT/XP/Vista/7 |
| Dimensions | 58 cm W × 47.6 cm D × 22.9 cm H |
| Weight | 31 kg |
| Operating Temperature | 0–50 °C (ideal at 25 °C) |
| Relative Humidity | ≤95% non-condensing |
| Altitude | up to 2000 m |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | Model 263A Potentiostat/Galvanostat |
| Instrument Type | Benchtop Electrochemical Workstation |
| Current Range | 7 decades, 100 mA to 100 nA |
| Current Resolution | 2 pA (min) |
| Potential Range | ±20 V |
| Compliance Voltage | ±20 V |
| Slew Rate | >1 V/µs |
| Rise Time | <1 µs |
| Input Impedance | >10¹² Ω in parallel with <20 pF |
| Electrometer Input Bias Current | <50 pA at 25°C |
| Minimum Time Resolution | 30 µs |
| Minimum Potential Step | 250 µV |
| Noise | <50 µV rms (typical) |
| EIS Frequency Range | Up to 100 kHz (with optional EIS module) |
| Communication Interfaces | IEEE-488 (GPIB), RS-232C |
| Software | PowerSuite (PowerSINE, PowerCORR, PowerCV, PowerSTEP) |
| Operating Temperature | 0–50 °C |
| Dimensions | 44.5 × 47.0 × 14.0 cm (W×D×H) |
| Weight | 16 kg |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | ParStat 4000 |
| Current Range | ±4 A (standard), ±20 A (optional) |
| Current Resolution | 1.2 fA (at 40 pA range) |
| Current Accuracy | ±0.5% ±4 pA (40–200 pA), ±0.2% of reading ±0.2% of range (2 nA–20 A) |
| Potential Range | ±10 V |
| Potential Accuracy | ±0.2% of reading ±2 mV |
| Potentiostatic Bandwidth | 3.75 MHz |
| EIS Frequency Range | 10 µHz to 5 MHz |
| Sampling Rate | 1 MS/s (synchronized potential/current/auxiliary), 500 kS/s (3 × 16-bit ADC) |
| Input Impedance | ≥10¹³ Ω |
| Leakage Current | ≤2 pA (at <25°C) |
| CMRR | 60 dB @ 100 kHz |
| Compliance Voltage | ±48 V |
| Rise Time (−1.0 V to +1.0 V) | <100 ns |
| Scan Rate | up to 10 kV/s (10 mV step) |
| iR Compensation | Positive feedback & dynamic iR compensation |
| Operating Temperature | 10–50°C |
| Dimensions (L×W×H) | 515 × 490 × 195 mm |
| Weight | 23 kg |
| Certifications | CE compliant |
| Brand | AMETEK–Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParSTAT MC Multi-Channel Electrochemical Workstation |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±2 A (standard) |
| Current Accuracy | 20 nA–2 A: ±0.2% of reading or ±0.2% of range |
| 4 nA | <0.5% ±20 pA |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK-Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSTAT 3 Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading or ±0.2% of range |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | AMETEK Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | VersaSTAT 3F Electrochemical Workstation |
| Current Range | ±650 mA (standard), ±2 A (internal optional) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range (20 nA to 2 A) |
| Potential Accuracy | ±2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Floating Ground Architecture | Yes (isolated electrode connections and rear-panel interfaces) |
| Data Acquisition | 3 × 16-bit, 500 kS/s |
| Input Impedance | ≥10¹² Ω |
| Leakage Current | ≤5 pA at <25°C |
| CMRR | 60 dB @ 100 kHz (typical) |
| Compliance | CE certified, compatible with GLP/GMP environments requiring audit-trail-capable software (via VersaStudio with optional 21 CFR Part 11 modules) |