Electronic Measurement Instruments
Filter
Showing 151–180 of 215 results
| Brand | Pico Technology |
|---|---|
| Origin | United Kingdom |
| Instrument Type | Digital Storage Oscilloscope |
| Model | EP031 |
| Channels | 2 |
| Bandwidth | 20 MHz (10 MHz at ±50 mV range) |
| Vertical Resolution | 12-bit |
| Sampling Rate | 200 MS/s (dual-channel) |
| Memory Depth | 250 M samples |
| Input Range | ±50 mV to ±200 V across 12 ranges |
| Input Impedance | 1 MΩ |
| Input Coupling | Software-selectable AC/DC |
| Overvoltage Protection | ±250 V (DC + AC peak) per input |
| Timebase Range | 100 ns/div to 5000 s/div |
| Protocol Decoding | CAN, CAN FD, LIN, FlexRay, SENT |
| Math Channels | Built-in RPM, frequency, and custom arithmetic functions |
| Probe Auto-Detection & Auto-Ranging | Yes |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1000 |
| Processor | Motorola DSP56002 & Intel 80C186/187 |
| Input Resolution | 18-bit per channel |
| ADC Interface | IEEE-488 (GPIB) |
| Self-test | On power-up |
| Power Supply | 180–250 VAC / 90–125 VAC, 50–60 Hz |
| Max Power Consumption | 40 W |
| Dimensions | 460 × 448 × 132 mm |
| Weight | 12 kg |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–80 °C |
| Storage Humidity | ≤92% RH, non-condensing |
| Software Platform | Windows-based |
| Harmonic Standards Compliance | IEC 61000-3-2, IEC 61000-3-4, IEC 61000-4-7, IEC 555-2 |
| Flicker Standards Compliance | IEC 61000-3-3 (replaces IEC 1000-3-3), IEC 60468 (Amend. 1), IEC 60555-3 (Amend. 1), IEC 60868 (Amend. 1) |
| Voltage Input Range | 90–300 Vrms (flicker: 40–504 Vrms) |
| Current Input Range | 5 mA–16 A (shunt ranges: 0.16 / 0.8 / 4 / 20 A) |
| Voltage Channel Input Impedance | >8 MΩ |
| Current Channel Impedance | <3.03 mΩ (max range) |
| Max Potential Difference | 150 mV |
| Accuracy | Better than ±0.2% for harmonics |
| Anti-aliasing Filter Attenuation | 70 dB |
| Transient Harmonic Smoothing | Low-pass filter, 1° phase shift (1.5 s period) |
| Measurement Modes | Single-shot, time-limited, continuous |
| Data Storage | Ring-buffer architecture retaining last 2.5 minutes of continuous measurement |
| FFT Points | 2048 |
| Frequency Range | 45–65 Hz (extendable to 16–2500 Hz) |
| Flicker Metrics | Pst, Plt, Pmax, P50%, P10%, P3%, P1%, P0.1%, CPF, d(t), dmax, dc |
| Voltage Fluctuation Resolution | ±2% error for d(t) and dmax |
| AC Power Supply Options | TPS 1500 (1-phase, 1.5 kVA), TPS-K10 (3-phase, 10 kVA), TPS-K20 (3-phase, 20 kVA) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 1008 |
| Generator Output | 160 A (continuous), 1200 A (transient) |
| Continuous Field Levels | 1–100 A/m (IEC/EN 61000-4-8 Classes 1–5) |
| Transient Field Levels | 300–1000 A/m |
| Coil Dimensions | 1.035 m × 1.035 m × 35 mm |
| Antenna Factor | 0.87 |
| Coil Inductance | ~0.6 µH |
| Coil Resistance | 670 µΩ |
| Generator Dimensions (W×D×H) | 385 × 215 × 400 mm |
| Generator Weight | 28 kg |
| Coil + Trolley + Stand Total Weight | 50 kg |
| Power Supply | 198–264 V AC, 50/60 Hz |
| Interface | RS232/RS485 (DB9) |
| Safety | Interlock-enabled, thermal cutoff, ≤4 Vrms open-circuit voltage |
| Compliance | IEC/EN 61000-4-8, EU Directives 89/336/EEC & 73/23/EEC |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 3 GHz / 6 GHz) |
| Weight | 4 kg (main unit) |
| Power Supply | DC battery-operated (integrated Li-ion) |
| Compliance | Fully compliant with CISPR 16-1-1:2023, EN 55016-1-1, MIL-STD-461G, DO-160G, FCC Part 15/18 |
| Calibration Architecture | Fully digital signal path with built-in RF self-calibration source |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, CISPR-Average, CISPR-RMS |
| RBW Filters | Digital implementation per CISPR 16-1-1 (200 Hz, 9 kHz, 120 kHz, 1 MHz) |
| Software Control | Native Narda STS EMCO software |
| Module Architecture | Pre-calibrated hot-swap functional modules (e.g., click noise analyzer, LISN interface, near-field probes) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM CA0010 |
| Frequency Range | 150 kHz – 30 MHz |
| Frequency Accuracy | ±100 Hz |
| Amplitude Range | 20 dBµV – 95 dBµV |
| Amplitude Accuracy | ±0.1 dB |
| Pulse Rise Time | ≥100 µs |
| Pulse Interval | ≥100 µs |
| Time Step Resolution | 10 µs |
| Pulse Repetition Rate | 1 Hz – 500 Hz |
| Repetition Rate Accuracy | ±1 Hz |
| Amplitude Flatness | ≤1.8 dB (150 kHz – 30 MHz) |
| Amplitude Resolution | 0.1 dB |
| Max Input Level | 140 dBµV (2 W) |
| Built-in LISN | Single-phase, 16 A, compliant with CISPR 16-1-2 (150 kHz – 30 MHz) |
| RF Connector | BNC (F) |
| Operating Temperature | −5 °C to +45 °C |
| Dimensions | 235 mm × 105 mm × 335 mm |
| Weight | 4.1 kg |
| Standards Compliance | CISPR 16-1-1, CISPR 16-1-2, CISPR 14-1 |
| Dynamic Range Enhancement | Integrated preselector |
| Signal Generation Capabilities | CW, click, and CISPR pulse signals |
| Software Resolution | 500 µs QP detection, full IF bandwidth display |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Type | RF Power Amplifier |
| Power Range | 15 W to 10,000 W |
| Compression Point | 1 dB typical |
| Stability | High long-term amplitude and phase stability |
| Configuration | Benchtop or rack-mountable (model-dependent) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2PB |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measurement Range | 0.1–0.5 µm & 0.5–20.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle-exceedance alarm |
| Data Interface | iPad-compatible wireless data acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready software architecture (user authentication, electronic signatures, change control logs) |
| Display & Control | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor cleaning fluids, ultrapure water (UPW), photomasks, silicon wafers, flat-panel display substrates, PCB etchants & rinsates, nano/microfiltration effluents, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Resonant EOM |
| Price | Upon Request |
| Brand | Red Sun Instrument |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HRDQ-37 |
| Price | USD 5,300 (FOB) |
| Compliance | GB 1409, GB 5654, GB/T 1693, ASTM D150-1998(2004) |
| Max Test Voltage | 10 kV AC (40–70 Hz) |
| Standard Capacitor | 100 pF built-in |
| Accuracy Class | Capacitance Ratio ±0.001%, tanδ ±0.5% |
| Measurement Method | Current-Comparator-Based Schering Bridge with Magnetic-Flux Balance Null Detection |
| Input/Output Terminals | HD, HS, LD, LS + Shielded Guard Pairs |
| Brand | Other brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | AD300 |
| Pricing | Upon Request |
| Quantum Efficiency | 70% @ 650 nm (Si), 55% @ 800 nm / 20% @ 1550 nm (InGaAs) |
| Dark Count Rate | 25 cps @ −20 °C (Si), 2000 cps @ −40 °C (InGaAs) |
| Dead Time | 65 ns (Si), 1.5 µs (InGaAs) |
| Timing Resolution | < 40 ps FWHM (typical, dependent on TCSPC system) |
| Operating Temperature Range | −40 °C to +85 °C |
| Power Supply | +5 V DC |
| Interface | SMB for TTL output & gating, USB-C for configuration and data streaming |
| Detector Active Area | 500 µm diameter |
| Optical Input | FC/PC fiber connector |
| Dimensions | 127.1 × 76.2 × 41.28 mm |
| Weight | 350 g |
| Brand | OEM |
|---|---|
| Origin | China (Domestically Engineered & Manufactured) |
| Manufacturer Type | Authorized Distributor |
| Product Category | Import-Grade Domestic Instrumentation |
| Model | Resonant Photodetector (RPD) |
| Pricing | Upon Technical Consultation |
| Brand | Rohde & Schwarz |
|---|---|
| Origin | Germany |
| Model | R&S ZNA |
| Frequency Range | 9 kHz to 1.5 GHz / 3.2 GHz / 7.5 GHz (base configurations) |
| Extended Frequency Range | Up to 750 GHz with harmonic mixers (e.g., R&S ZVA-Z/ZC series) |
| Dynamic Range | >130 dB (typ. at mid-band, depending on configuration and IF bandwidth) |
| Port Count | 2-port or 4-port configurations available |
| Internal Signal Sources | Up to four phase-coherent synthesized sources |
| Internal Local Oscillators | Up to two dedicated LOs for mixer measurements |
| Receivers | Up to eight independent receivers |
| Pulse Modulation | Up to four integrated pulse modulators/generators |
| Power Sweep Range | –40 dBm to +13 dBm (with optional step attenuators) |
| Brand | ROOKO |
|---|---|
| Model | FT-300A Series |
| Measurement Principle | Four-Terminal (Kelvin) Method with Constant Current Source |
| Resistance Range | 10⁻⁸ Ω to 2×10⁷ Ω (FT-320 variant supports 0–10 A high-current output) |
| Resistance Accuracy | ≤ ±0.3% of reading |
| Voltage Resolution | 0.1 µV |
| Temperature Compensation | Built-in, automatic |
| Display | Backlit LCD with bilingual (English/Chinese) interface |
| Data Output | USB interface for optional PC software |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments |
| Brand | ROOKO |
|---|---|
| Model | FT-305 |
| Origin | Zhejiang, China |
| Impedance Range | 10³–10¹⁷ Ω |
| Test Voltage | 0–1000 V (adjustable) |
| Accuracy | ±1% for <1 GΩ, ±20% for ≥10 TΩ |
| Power Consumption | 5 W |
| Interface | USB + RS-232 |
| Operation Modes | Local LCD/Keypad & PC Software Control |
| Compliance | Designed for ASTM D257, IEC 62631-3-1, GB/T 1410 |
| Brand | SAF |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | J0GSAP5401 |
| Frequency Range | 24.300–43.000 GHz |
| DANL | –100 dBm @ RBW = 100 kHz (–150 dBm/Hz) |
| RBW Options | 100 / 300 / 1000 kHz |
| VBW Options | 1 / 3 / 10 / 30 / 100 kHz |
| Minimum Span | 10 MHz |
| Maximum Span | Full Bandwidth (18.7 GHz) |
| Sweep Time | 0.2 s @ 100 MHz Span |
| Amplitude Accuracy | ±1 dB |
| RF Input | 50 Ω SMA (female) |
| Interface | USB Type-C (power & data) |
| Battery | Dual 3500 mAh Li-ion |
| Operating Time | Up to 4 h |
| Operating Temperature | –15 °C to +55 °C |
| Dimensions | 135 × 83 × 34 mm |
| Weight | 0.57 kg |
| IP Rating | IP54 |
| Display | Resistive LCD Touchscreen (glove-compatible) |
| Brand | Santec |
|---|---|
| Model | HSL-1 / HSL-10 / HSL-20 / HSL-2100 |
| Wavelength | 1060 nm (HSL-1, HSL-10), 1310 nm (HSL-20, HSL-2100) |
| Output Power | ≥40 mW (HSL-1/10/20), >20 mW (HSL-2100) |
| Sweep Range | ≥75 nm (HSL-1), ≥90 nm (HSL-10), ≥105 nm (HSL-20), ≥170 nm (HSL-2100) |
| Sweep Rate | 10–400 kHz (HSL-1), 100 kHz (HSL-10 & HSL-20), 20 kHz (HSL-2100) |
| Coherence Length | >100 mm (theoretical, HSL-1), ≥10 mm (HSL-10), ≥16–20 mm (HSL-20), ≥6 mm (HSL-2100) |
| Tuning Technology | MEMS-based VCSEL (HSL-1), MEMS-scanned external cavity (HSL-10/20), Polygon-based scanning (HSL-2100) |
| Compliance | IEC 60601-1, CE Marked (Medical Use) |
| Interface | USB 2.0 |
| OEM Support | Yes |
| Application Domain | Ophthalmic OCT, Dental OCT, Endoscopic OCT, Industrial Metrology, Fiber Optic Sensing, Spectral Domain Interferometry |
| Brand | SATOVAC |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CT-D-600 |
| Quotation | Upon Request |
| Compatible Pump Displacement | ≤ 600 L/min |
| Brand | auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SATURN Series Transient Recorder for Time-Interval & Frequency Analysis |
| Pricing | Available Upon Request |
| Brand | ZEPTOOLS |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PicoFemto NI-100 |
| Pricing | Upon Request |
| Load Range | 100 mN |
| Force Resolution | 10 µN |
| Response Time | 50 ms |
| Closed-Loop XY Nanopositioning Stage | Travel ±20 µm (100 µm total), Positional Accuracy: 20 nm |
| Open-Loop XYZ Coarse Stage | XY ±10 mm, Z 10 mm, Minimum Step Size ≤1 nm |
| Dimensions (Nanoforce Stage Only) | 130 × 65 × 55 mm |
| Weight (Bare Stage) | ~300 g |
| Max Sample Size | 30 × 30 mm |
| Optional Modules | High-Temperature Heating (up to 400 °C), Electrical Biasing |
| Brand | Senbe |
|---|---|
| Model | DSJ-LJ |
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Pricing | Available Upon Request |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | SUPEC 2050 |
| Price | Contact for Quotation |
| Brand | Tektronix |
|---|---|
| Origin | USA |
| Model | MSO54 / MSO56 / MSO58 |
| Analog Bandwidth | 350 MHz – 2 GHz |
| Sample Rate | 6.25 GS/s (per channel) |
| Record Length | 62.5 M – 125 M points |
| FlexChannel Inputs | 4 / 6 / 8 analog channels (each convertible to 8 digital channels) |
| Max Digital Channels | 32 / 48 / 64 (with TLP058 logic probes) |
| Vertical Resolution | Up to 16 bits (via 12-bit ADC + DSP enhancement) |
| Display | 15.6-inch Full HD capacitive touchscreen |
| Optional Integrated AWG | 1-channel arbitrary/function generator |
| OS Option | Windows 10 IoT Enterprise (optional) |
| Serial Protocol Analysis | I²C, SPI, USB 2.0, Ethernet (10/100BASE-T), CAN, LIN, RS-232/422/485 |
| Jitter Analysis | Advanced real-time jitter decomposition and visualization |
| Brand | Tektronix |
|---|---|
| Origin | USA |
| Model | DPO7000C Series / MSO/DPO70000 Series |
| Analog Bandwidth | 500 MHz – 3.5 GHz (DPO7000C) |
| Sample Rate | 10 GS/s – 40 GS/s (DPO7000C) |
| Analog Channels | 4 |
| Digital Channels | 16 (MSO models) |
| Maximum Record Length | 500 Mpts (DPO7000C) |
| Brand | Tektronix |
|---|---|
| Origin | USA |
| Model | PWS2000 Series |
| Channel Configuration | Single-, Dual-, or Triple-Channel |
| Isolation | Fully Isolated Channels |
| Current Measurement Resolution | 0.1 mA |
| Application Focus | High-Voltage Device Testing, Low-Current Sensitivity Applications, Battery-Powered Device Evaluation, Programmable Power Simulation |
| Brand | Tektronix |
|---|---|
| Origin | USA |
| Model | TTR500 Series |
| Frequency Range | 100 kHz to 6 GHz |
| Dynamic Range | >122 dB |
| Output Power Range | –50 dBm to +7 dBm |
| Trace Noise | <0.008 dB RMS |
| Port Configuration | 2-Port S-Parameter Measurement (S11, S21, S12, S22) |
| Software | VectorVu-PC™ |
| Compliance | SCPI-compliant, Touchstone file import/export (.s1p, .s2p), LabVIEW™ drivers, Windows API support |
| Warranty | 3 years |
| Brand | TESCOM (USA) |
|---|---|
| Origin | USA |
| Model | TV220E / TV220EX |
| Max Measurement Range | 5.58 km (Vp = 0.93) |
| Basic Accuracy | ±0.01% ±300 ps |
| Horizontal Resolution | 0.05–20 ns |
| Display Resolution | 1024 × 600 (7″ capacitive touchscreen, 800 cd/m² brightness) |
| Pulse Width Options | 2, 5, 25, 125, 250, 500 ns |
| Output Impedance | 75 Ω |
| Output Pulse Amplitude | 4–6 V |
| Velocity Factor (Vp) Range | 0.300–1.000 |
| Event Markers | >6 |
| Battery | 4-cell Li-ion, 60 Wh (>8 h typical operation) |
| Dimensions (TV220E) | 27 × 16 × 5 cm |
| Weight (TV220E) | 1200 g |
| IP Rating (TV220EX) | IP67 |
| Interface | F-type connector with swappable couplers |
| Connectivity | USB, Bluetooth Low Energy (BLE), Wi-Fi |
| Storage Capacity | >100 trace files |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 608-H1 |
| Operating Temperature Range | 0 to +50 °C |
| Storage Temperature Range | −40 to +70 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 10 to 95 %RH |
| Humidity Accuracy | ±3 %RH |
| Humidity Resolution | 0.1 %RH |
| Dew Point Calculation | Yes |
| Measurement Interval | 18 s |
| Battery Type | 9 V block battery |
| Battery Life | 8736 h (typ.) |
| Weight | 168 g |
| Dimensions | 120 × 89 × 40 mm |
| Housing Material | ABS |
| Temperature Sensor Type | NTC |
| Humidity Sensor Type | Capacitive |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7450 |
| AC Voltage Range | 12–1000 V |
| Operating Temperature | −10 to +50 °C |
| Storage Temperature | −15 to +60 °C |
| Relative Humidity | 0–80 % RH (non-condensing) |
| Weight | 63 g |
| Dimensions | 155 × 25 × 23 mm |
| Protection Rating | IP67 |
| Safety Category | CAT IV 600 V / CAT III 1000 V |
| Compliance | EN 61010-1, EN 61326-1 |
| Power Supply | 2 × AAA batteries |
| Integrated LED Illumination | Yes |
| Alarm Type | Visual (dual-color LED) + Audible (buzzer) |
| Sensitivity Modes | 2-level (Phase Detection / Voltage Presence Confirmation) |
| High-Frequency Interference Rejection | Built-in filter circuit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7601 |
| Type | True RMS Digital Multimeter |
| Safety Rating | CAT III 600 V / CAT IV 300 V |
| Display | 6000-count LCD with backlight |
| Auto Power Off (APO) | Yes |
| Low-Pass Filter (LPF) | Yes |
| Measurement Functions | AC/DC Voltage, AC/DC Current, Resistance, Continuity, Diode Test, Capacitance, Frequency, Duty Cycle, Temperature (via optional probe) |
| Compliance | IEC/EN 61010-1, IEC/EN 61326-1 (EMC) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0590 7701 |
| Measurement Type | True RMS AC/DC Clamp Multimeter |
| Voltage Range | 600 V AC/DC |