| Frequency Range | 9 kHz–3 GHz (6600/6600D: up to 1 GHz) |
|---|---|
| Power Range | 100 nW–1 W (-40 dBm to +30 dBm) |
| Linearity | ±0.2 dB (typ.) |
| Measurement Units | dBm, W, Vrms |
| Interface | USB 1.0/1.1/2.0 (6600/6600D: RS-486) |
| Probe Integration | Integrated sensor and meter architecture |
| RMS Detection | True RMS, >70 dB dynamic range |
| Bidirectional Measurement | Forward & reverse power |
| Calibration | Reference-source-free operation |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 7000 |
| Frequency Range | 150 kHz – 1 GHz |
| Input A (Conducted) | 150 kHz – 30 MHz, 50 Ω BNC |
| Input B (Radiated) | 30 MHz – 1 GHz, 50 Ω N-type |
| Built-in LISN | 2 × 16 A, 50 Ω/50 µH |
| VSWR | <1.2 (≥10 dB attenuation), <2 (≥0 dB attenuation) |
| Max Input | <127 dBµV (sinusoidal AC) |
| Detectors | Peak, Quasi-Peak, Average (hardware-based) |
| Measurement Uncertainty | ±2 dB (150 kHz–30 MHz), ±2–3 dB (30–300 MHz), ±2–4 dB (300–1000 MHz) |
| Display Units | dBµV, dBµV/m, dBpW |
| IF Bandwidths | 9 kHz / 120 kHz (CISPR-compliant) |
| AM/FM Demodulation Module | Integrated with headphone output |
| Dimensions | 364 × 120 × 376 mm |
| Weight | 5 kg |
| Operating Temperature | 5–40 °C |
| Power Supply | 115/230 VAC ±10%, 50/60 Hz, max. 30 VA |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 + 9030 |
| Frequency Range | 10 Hz – 3 GHz |
| Detection Modes | Peak (PK), Quasi-Peak (QP), Average (AVG), RMS |
| Interface | RS-232, Bluetooth (optional), High-Speed Optical Fiber (≥2.5 GB/s) |
| Compliance | CISPR 16-1-1, CISPR 16-2-3, MIL-STD-461G, EN 55032/55035, IEC 61000-4-3 |
| Built-in Signal Generator | 10 Hz – 50 MHz, programmable output |
| Scalar Network Analysis Capability | Yes |
| Real-Time FFT Processing | Yes |
| Internal Memory | High-capacity embedded storage |
| Preselector | Integrated analog preselector with pulse-handling capability |
| Digital LO Architecture | Fully synthesized complex digital IF local oscillator |
| Adaptive RF Attenuation | FPGA-controlled, DSP-driven automatic gain control |
| Click Analyzer | Optional (1-channel internal, 3-channel external) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010 |
| Type | CISPR 14-1 Compliant Click Analyzer Module |
| Channel Options | Single-channel or 4-channel (base unit + optional 3-channel expansion) |
| Compliance | Fully compliant with CISPR 14-1:2005, including all clauses E3 and E4 |
| Detection Mode | Quasi-Peak (QP) and Peak, with real-time IF dynamics |
| Data Storage | High-capacity internal memory for full event logging (duration, interval, amplitude, timestamp per click) |
| Analysis Engine | Automated click rate (N) calculation, upper-quartile (UQ) method implementation, exception clause auto-application, “Smart Test” adaptive sequencing |
| Reporting | Fully automated, standards-mandated report generation (PDF/CSV), including all CISPR 14-1 required parameters and metadata |
| Receiver Architecture | Full-digital, integrated quasi-peak receiver with real-time QP value display |
| Software Interface | PC-based control with live waveform/event visualization, multi-level event filtering, and GLP-compliant audit trail support |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 3 GHz / 6 GHz) |
| Weight | 4 kg (main unit) |
| Power Supply | DC battery-operated (integrated Li-ion) |
| Compliance | Fully compliant with CISPR 16-1-1:2023, EN 55016-1-1, MIL-STD-461G, DO-160G, FCC Part 15/18 |
| Calibration Architecture | Fully digital signal path with built-in RF self-calibration source |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, CISPR-Average, CISPR-RMS |
| RBW Filters | Digital implementation per CISPR 16-1-1 (200 Hz, 9 kHz, 120 kHz, 1 MHz) |
| Software Control | Native Narda STS EMCO software |
| Module Architecture | Pre-calibrated hot-swap functional modules (e.g., click noise analyzer, LISN interface, near-field probes) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010 |
| Frequency Range | 10 Hz – 30 MHz (expandable to 2.7 GHz) |
| RF Input | 50 Ω, BNC female |
| Attenuator | 0–35 dB (5 dB steps) |
| Preamp Gain | 10 dB / 20 dB (post-preselector) |
| Max Input (non-destructive) | 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density) |
| Preselector | 7 filters (<9 kHz, 9–150 kHz, 150 kHz–500 kHz, 500 kHz–3 MHz, 3–10 MHz, 10–20 MHz, 20–30 MHz) |
| IF Bandwidths (6 dB) | 10 Hz, 100 Hz, 1 kHz, 10 kHz |
| Detector Modes | Peak, Quasi-Peak, RMS, Average (parallel) |
| Measurement Time | 1 ms – 30 s |
| Display Units | W, V, A, dBm, dBµV, dBµA, dBpW, dBµV/m, dBµA/m |
| Span/Division | 1–100 kHz |
| IF Resolution | 0.1–10 kHz |
| Amplitude Accuracy (S/N > 20 dB) | ±1.0 dB (1–150 kHz), ±0.8 dB (150 kHz–30 MHz) |
| Tracking Generator | 10 Hz–50 MHz, output 60–90 dBµV (0.1 dB steps), accuracy ±0.3 dB (9 kHz–30 MHz) |
| Demodulation | AM/FM |
| Interfaces | RS-232, USB, IEEE-488 (optional), wireless (optional) |
| Operating Temperature | 0–40 °C |
| Power | 12 V DC |
| Dimensions | 235 × 105 × 330 mm |
| Weight | 5 kg |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | 9010F |
| Frequency Range | 10 Hz to 30 MHz (extendable to 3 GHz / 6 GHz / 18 GHz with optional modules 9030 / 9060 / 9018) |
| Compliance | CISPR 16-1-1, MIL-STD-461, DO-160 |
| Detection Modes | Peak, Quasi-Peak, Average, RMS, RMS-Average, CISPR-Average, APD |
| IF Bandwidths | 200 Hz, 9 kHz, 1 kHz–300 kHz (6 dB) |
| Resolution | 0.1 Hz |
| Frequency Accuracy | <1 ppm |
| Input Impedance | 50 Ω (BNC-f) |
| VSWR | <1.20 @ 10 dB attenuation |
| Max. Input Level | 137 dBµV (CW), 97 dBµV/MHz (pulse spectral density) |
| Built-in Preamp | +20 dB |
| Attenuation | 0–35 dB (5 dB steps) |
| Real-time FFT Sweep Speed | <5 s for CISPR Band A, <20 s for Band B (QPK, 1 s dwell) |
| Operating Temperature | –5 °C to +45 °C |
| Weight | 4.1 kg (with integrated Li-ion battery) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMM 9030 |
| Pricing | Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM 9060 |
| Frequency Range | 30 MHz – 6 GHz |
| Frequency Resolution | 0.1 Hz |
| Measurement Accuracy | < 2 ppm |
| Input Impedance | 50 Ω, N-type female |
| VSWR | < 1.2 @ 0 dB attenuation, < 2.0 @ full attenuation |
| Attenuation Range | 0–55 dB (5 dB steps) |
| Pre-amplifier Gain | 10 dB |
| Max. Input Level (non-damaging) | 137 dBµV (1 W sine), 97 dBµV/MHz (pulse spectral density) |
| Preselector | Low-pass + six band-pass filters covering 30 MHz–1000 MHz and >1000 MHz |
| IF Bandwidths (3 dB) | 3, 10, 30, 100, 300 kHz, 1 MHz |
| IF Bandwidths (6 dB) | 120 kHz (CISPR 16-compliant) |
| Noise Floor | < 2 dBµV (QP, 200 Hz BW, 9–150 kHz), < −2 dBµV (AV, same BW) |
| Detectors | Peak, Quasi-Peak, Average, RMS, Smart Detector |
| Parallel Detection | Supported for Peak, QP, RMS, AV |
| Sweep Time | 1 ms – 30 s (CISPR 16 default) |
| Display Units | dBm, dBµV |
| SNR | > 20 dB |
| Amplitude Probability Distribution (APD) Capability | Yes |
| Tracking Generator Output | 10 Hz – 30 MHz, AM demodulation via PMM 9010 |
| Interface | High-speed optical fiber (≥2.5 Gb/s), RS-232 (service only) |
| Power Supply | 10–15 VDC, 2.5 A |
| Operating Temperature | 0 °C – 40 °C |
| Dimensions | 235 × 105 × 105 mm |
| Weight | 2.0 kg |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | ASN / LISN |
| Pricing | Available Upon Request |
| Current Ratings | 2 A to 500 A |
| Impedance Configurations | 50 Ω // (1 Ω + 5 µH), 50 Ω // (5 Ω + 50 µH), 150 Ω, and ISO 7637-2 compliant variants |
| Standards Compliance | CISPR 22, CISPR 25, ISO 7637-2, MIL-STD-461G (CE102, CS101, CS106), EN 55032, EN 55035 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BC-01 |
| Frequency Range | 30–200 MHz |
| Impedance | 50 Ω |
| Polarization | Linear (Vertical/Horizontal) |
| VSWR | ≤2.5:1 (typ. across band) |
| Gain | −2.5 to +1.5 dBi (frequency-dependent) |
| Connector | N-type (female) |
| Max Input Power | 1 kW (CW), 5 kW (peak, pulsed) |
| Operating Temperature | −40 °C to +70 °C |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | C106209 |
| Price Range | USD 1,400 – 7,000 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | PMM CA0010 |
| Frequency Range | 150 kHz – 30 MHz |
| Frequency Accuracy | ±100 Hz |
| Amplitude Range | 20 dBµV – 95 dBµV |
| Amplitude Accuracy | ±0.1 dB |
| Pulse Rise Time | ≥100 µs |
| Pulse Interval | ≥100 µs |
| Time Step Resolution | 10 µs |
| Pulse Repetition Rate | 1 Hz – 500 Hz |
| Repetition Rate Accuracy | ±1 Hz |
| Amplitude Flatness | ≤1.8 dB (150 kHz – 30 MHz) |
| Amplitude Resolution | 0.1 dB |
| Max Input Level | 140 dBµV (2 W) |
| Built-in LISN | Single-phase, 16 A, compliant with CISPR 16-1-2 (150 kHz – 30 MHz) |
| RF Connector | BNC (F) |
| Operating Temperature | −5 °C to +45 °C |
| Dimensions | 235 mm × 105 mm × 335 mm |
| Weight | 4.1 kg |
| Standards Compliance | CISPR 16-1-1, CISPR 16-1-2, CISPR 14-1 |
| Dynamic Range Enhancement | Integrated preselector |
| Signal Generation Capabilities | CW, click, and CISPR pulse signals |
| Software Resolution | 500 µs QP detection, full IF bandwidth display |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | Click4E |
| Compliance | CISPR 14-1:2005 (incl. Exceptions E3 & E4) |
| Channel Configuration | 1–4 channels (software-activated, hardware-expandable) |
| Measurement Mode | Fully automatic parallel testing or manual single-channel operation |
| Detection Method | Quasi-Peak (QP) detection per CISPR 16-1-1 |
| Data logging | Per-pulse duration, interval, amplitude, and timestamp per IEC/CISPR requirements |
| Report generation | Auto-generated, audit-ready PDF/CSV with full traceability |
| Storage | High-capacity embedded flash memory for ≥10⁶ pulse events |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EHP-50C |
| Frequency Range | 5 Hz – 100 kHz |
| Axes | Simultaneous X/Y/Z vector measurement |
| Calibration Data Storage | Built-in EEPROM |
| Interface | Optical fiber (compatible with PMM 8053A field meter) |
| Signal Processing | Integrated DSP with selectable 7-band spectral resolution |
| Operating Temperature | −10 °C to +40 °C |
| Physical Form Factor | Compact cubic probe (dimensions not specified) |
| Power Management | Internal rechargeable battery with charging port |
| Status Indication | LED indicators for power/on/off and operational mode |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | EP600 / EP601 |
| Frequency Range | 100 kHz–9.25 GHz (EP600), 10 kHz–9.25 GHz (EP601) |
| Flatness | ±0.4 dB (typ.), ±0.5 dB (typ.) |
| Dynamic Range | 0.14–140 V/m (60 dB), 0.5–500 V/m (60 dB) |
| Linearity | ±0.4 dB (50 MHz, 0.3–100 V/m |
| Resolution | 0.01 V/m |
| Isotropy | ±0.5 dB (±0.3 dB typical) |
| Overload | 300 V/m (EP600), 1000 V/m (EP601) |
| Sampling Rate | 22 samples/s (max), adjustable down to 0.03 samples/s |
| Digital Filter | Adjustable low-pass, 2.3–28 Hz |
| Power Supply | Rechargeable 3 V Li-Mn battery (capacity: mAh not specified) |
| Operating Time | 80 h |
| Charging | Trickle charge, full capacity in 48 h |
| Temperature Sensor Resolution | 0.1 °C |
| Battery Voltage Sensing Resolution | 10 mV |
| Dimensions | ≤53 mm (probe body: 17 mm, sensor core: 17 mm) |
| Weight | 25 g (including 1 m fiber pigtail) |
| Connector | 20-UNF female |
| Fiber Interface | Duplex optical fiber, standard length 10 m (20/40 m optional) |
| PC Interface | USB via fiber-optic transceiver |
| Compliance | CE, RoHS, IEC 61000-4-3 (radiated immunity test support), ISO/IEC 17025 traceable calibration |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | FR4003 |
| Frequency Range | 9 kHz – 30 MHz |
| Frequency Resolution | 1 Hz |
| Frequency Accuracy | ±1 ppm |
| Internal Attenuation | 0–30 dB (10 dB steps) |
| Preamp Gain | 20 dB |
| Field Strength Limit | 500 V/m (CW, ATT ≥ 20 dB) |
| Noise Floor | 13 dBμV/m (peak), 2 dBμV/m (average) |
| Spurious Response Suppression | < −10 dBμV (ATT = 0 dB, avg, dwell time 10 ms, auto RBW, 50 Ω port) |
| Measurement Accuracy | ±0.8 dB |
| Compliance | CISPR 16-1-1, CISPR 12/16/25, MIL-STD-461, DO-160 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Lamp Test Accessories Kit |
| Pricing | Available Upon Request |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model Range | L2-16A, L3-32, L3-64, L2-D, L3-100, L3-500, L1-150, L5-50-1-01, L5-70-1-01, L5-100-1-01 |
| Current Ratings | 2 A to 350 A |
| Impedance Networks | 50 Ω // (5 Ω + 50 µH), 150 Ω, 50 Ω // (1 Ω + 5 µH) |
| Compliance | CISPR 16-1-2, CISPR 22, CISPR 25, ISO 7637-2, MIL-STD-461G (RS103, CS106), EN 55032/55035 |
| Control Interface | TTL/RS-232 compatible with PMM receivers (e.g., PRM9000, EMI Suite) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | LP-02 |
| Pricing | Available Upon Request |
| Frequency Range | 200–3000 MHz |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Type | RF Power Amplifier |
| Power Range | 15 W to 10,000 W |
| Compression Point | 1 dB typical |
| Stability | High long-term amplitude and phase stability |
| Configuration | Benchtop or rack-mountable (model-dependent) |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | RA-01, RA-01-HV, BC-01, LP-02, LP-03, AS-02, AS-03 |
| Frequency Range | 9 kHz – 6 GHz |
| Max Input Power | 1000 W (LP-series), 300 W (Horn) |
| Gain | up to 18.77 dBi |
| Compliance | CISPR 16-1-4, ANSI C63.4, IEC 61000-4-3 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model Series | RA-01, RA-01-HV, BC-01, LP-02, LP-03, AS-02, AS-03 |
| Frequency Range Coverage | 9 kHz – 6 GHz (system-dependent) |
| Antenna Types | Rod, Biconical, Log-Periodic, Multi-Antenna Sets |
| HV Rating | Up to 20 kV/m (RA-01-HV, 150 kHz–30 MHz) |
| Compliance | Designed for CISPR 16-1-4, ANSI C63.4, MIL-STD-461, IEC 61000-4-3 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Product Types | Triaxial Loop Antenna (RF-300), BALUN Transformer, Coupling/Decoupling Network (CDN), Impedance Stabilization Network (ISN), Lamp Simulator (Incandescent, Fluorescent, LED Driver Emulator), V-Network, Conical Metallic Shielding Enclosure |
| Import Status | Imported |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model | SHC-1, SHC-1/1000, SHC-2 |
| Impedance | 1500 Ω |
| Attenuation | 35 dB (SHC-1 & SHC-1/1000), 30 dB (SHC-2) |
| Max Voltage Rating | 1 kV (SHC-1/1000 only) |
| Compliance | CISPR 16-1-2:2023, IEC 61000-4-6 |
| Brand | PMM |
|---|---|
| Origin | Italy |
| Model Series | SHC-Series |
| Impedance | 1500 Ω |
| Attenuation | SHC-1 & SHC-1/1000: 35 dB |
| SHC-2 | 30 dB |
| Max Input Voltage | SHC-1/1000: 1 kV<sub>DC/AC<sub>rms</sub></sub> |
| Compliance | CISPR 16-1-2:2023 Edition |
| Application | Conducted Emission Testing per EN 55032, EN 55022, FCC Part 15, MIL-STD-461G |
| Brand | PMM |
|---|---|
| Model | XC 9010 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Pricing | Upon Request |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMM9010/03P |
| Pricing | Upon Request |
| Brand | PULUODY |
|---|---|
| Model | PMT-2PB |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Sensor Generation | 8th-Generation Dual-Laser Optical Sensor |
| Measurement Range | 0.1–0.5 µm & 0.5–20.0 µm (customizable to 1–100 µm or 4–70 µm(c) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic Flow Regulation |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable particle-exceedance alarm |
| Data Interface | iPad-compatible wireless data acquisition system |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + embedded touchscreen version) |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Compliance | Supports GLP/GMP audit trails, FDA 21 CFR Part 11–ready software architecture (user authentication, electronic signatures, change control logs) |
| Display & Control | 7-inch color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Application Scope | Semiconductor cleaning fluids, ultrapure water (UPW), photomasks, silicon wafers, flat-panel display substrates, PCB etchants & rinsates, nano/microfiltration effluents, polymer solutions, and insoluble particulate analysis in organic solvents |
| Brand | Auniontech (HaoLiang) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Resonant EOM |
| Price | Upon Request |