Elemental Analyzer
Filter
Showing 151–166 of 166 results
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart CN/CNS |
| Detection Principle | Dynamic Flash Combustion coupled with Gas Chromatographic Separation |
| Detector Options | TCD (standard), optional chemiluminescence or IR detectors |
| Combustion Temperature | up to 1800 °C (Sn capsule mode) |
| Warranty | 15 years on combustion furnace and TCD detector |
| Automation | Fully software-controlled oxygen injection, sample weighing, and combustion timing |
| Compliance | Designed for GLP/GMP environments |
| Carrier Gas Options | Helium (standard), Argon (cost-optimized alternative) |
| Modular Configurations | Upgradable to CHNS, CHN, NC, NCS, N, S, O modes |
| Sample Types | Solids (soils, sediments, biomass, coal, polymers), liquids (oils, extracts, aqueous solutions), and heterogeneous matrices |
| Throughput | Up to 120 samples/day with dual autosamplers (solid + liquid) |
| Software Platform | EagerQ™ v3.2 with method templates, calibration wizards, and raw data export (CSV, XML, PDF) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Elemental Analyzer |
| Nitrogen Measurement Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Mass Requirement | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Linear Range | 0.001–500 mg N |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Sample Capacity | Up to 125 positions (with optional 4-position carousel) |
| Compliance | ASTM D5142, AOAC 992.15, ISO 14891, EN ISO 16634-1/-2, USP <28>, FDA 21 CFR Part 11 ready (via EagerSmart software audit trail) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.001–500 mg N |
| Reproducibility | <0.3% RSD |
| Sample Weight | ≥1 g |
| Recovery Rate | 99.5–100% |
| Digestion/Combustion Time | 3–4 min per sample |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 620 × 580 × 500 mm |
| Linearity Range | 0.001–500 mg N |
| Sample Capacity | Up to 125 positions (with optional multi-rack configuration) |
| Gas Flow Control | Electronic Flow Control (EFC) |
| Software Platform | EagerSmart™ Operating Software |
| Compliance | ASTM D515, ISO 13878, AOAC 992.15, USP <467>, EN ISO 13878, and GLP/GMP-ready audit trail support |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Model | FlashSmart |
| Element Range | CHNSO, CHNS, CHN, NCS, NC, N, S, O (configurable modes) |
| Analysis Time | 5–10 min (sample-weight- and matrix-dependent) |
| Detection Limit | <40 ppm (S: down to 4 ppm with FPD/IR |
| Measurement Precision | ≤0.05% RSD |
| Sample Introduction | Up to 500 µL liquid or 1 g solid |
| Detector Options | Thermal Conductivity Detector (TCD), Flame Photometric Detector / Infrared Detector (FPD/IR), Isotope Ratio Mass Spectrometer (IRMS) interface, Chlorine (Cl) measurement module |
| Combustion Temperature | Up to 1800 °C |
| Compliance | Designed for GLP/GMP environments |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP304 |
| Pricing | Upon Request |
| Brand | Timepower |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | TP304 |
| Pricing | Upon Request |
| Brand | TimePower |
|---|---|
| Model | TP304 |
| Origin | Beijing, China |
| Manufacturer | TimePower (Domestic Producer) |
| Measurement Principle | Photometric Colorimetry (Based on Lambert-Beer Law) |
| Display | 5.0-inch TFT color touchscreen (Chinese UI) |
| Range | 0.0–200 μg/L |
| Accuracy | ±3% F.S. |
| Resolution | 0.1 μg/L |
| Repeatability | ≤1% |
| Stability | ±1.5% F.S. / 4 h |
| Operating Temp. | 5–45 °C |
| Humidity | ≤90% RH (non-condensing) |
| Power Supply | AC 85–265 V, 45–65 Hz |
| Power Consumption | ≤30 W |
| Dimensions | 260 × 200 × 180 mm |
| Weight | 3.2 kg |
| Data Storage | 256 entries (circular buffer) |
| Light Source | Imported monochromatic cold LED |
| Calibration | Automatic zero calibration (blank), periodic curve calibration recommended |
| Compliance Context | Designed for routine QC in power plant water chemistry per ASTM D1066, ISO 5667-3, and DL/T 938 (Chinese thermal power industry standard) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Model | DMA-500 |
| Pricing | Upon Request |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection (No Acid Digestion Required) |
| Automation | 100-Position 4-Axis Robotic Autosampler |
| Thermal Treatment | Dual-Zone PID-Controlled Ashing & Catalytic Combustion Furnace |
| Trapping System | Constant-Power Heated Mercury Trap with Rapid Thermal Ramp |
| Detection Architecture | Tandem Dual-Absorption Cells + Dual-Beam Light Source Correction |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DMA-600 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Sample Introduction | Direct Solid/Liquid/Gas Injection |
| Dual Sample Preparation Pathways | Catalytic Thermal Decomposition + Gold Amalgamation OR Stannous Chloride Reduction + Gold Amalgamation |
| Furnace Control | PID Temperature Regulation (Ashing & Catalytic Combustion Zones) |
| Mercury Trap | Constant-Power Heated Trap |
| Absorption Cell | Dual-Temperature-Controlled Flow-Through Cells (Heated to Maintain Hg⁰ in Vapor Phase) |
| Optical System | Dual-Beam Reference Compensation |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER NS |
| Detection Principle | UV Fluorescence for Sulfur / Chemiluminescence for Nitrogen |
| Sample Types | Liquids, Gases, LPG, Solids |
| Measurement Range | S and N from sub-ppb to percent level |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Control & Data Management Software |
| Compliance | ASTM D5453, D7183, D7184 |
| Optional Autosamplers | 105-position 2-mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled UVF and CLD detectors with active feedback loops |
| Automation Level | Fully automated combustion, gas flow control, calibration, and data validation |
| Brand | TE/Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Liquids, Gases, Liquefied Petroleum Gas (LPG), Solids |
| Measurement Range | 0.0025–1000 mg absolute chlorine |
| LOD | 0.025 mg/L |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional Software |
| Compliance | ASTM D5808, ASTM D7042, ISO 16939, IP 566, UOP 390, EN ISO 16939, SH/T 0689 |
| Optional Autosamplers | 105-position 2 mL vial XYZ autosampler (with auto-dilution & auto-calibration), Gas/LPG autosampler, 20-position solid autosampler |
| Detector | Temperature-controlled microcoulometric cell with closed-loop feedback control |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | CN802 |
| Detection Principle | High-Temperature Combustion (Dumas Method) coupled with NDIR CO₂ detection and TCD N₂ detection |
| Sample Throughput | Up to 30 samples unattended |
| Sample Form | Solid and liquid (up to 1 g) |
| Carrier Gases | Helium or Argon (switchable without hardware modification) |
| Compliance | AOAC, AACC, ASBC, ISO, DIN, IFFO, OIV, ASTM, EPA |
| Detection Technologies | NDIR for CO₂, LoGas™ TCD for N₂ |
| Moisture Removal | DriStep™ integrated desiccant system |
| Automation | 30-position autosampler (expandable to 90 positions with additional trays) |
| Software Platform | CNSoft™ + Ermes Cloud Connectivity |
| Regulatory Support | Audit trail, user management, electronic signatures (21 CFR Part 11 ready) |
| Brand | Xianjian |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Measurement Range | 0.1–240.0 mg N per sample |
| Distillation Time | 3–8 min per sample |
| Accuracy | Relative Error ≤ 0.3% |
| Repeatability | Parallel Difference ≤ 0.2% |
| Sample Weight Capacity | ≤ 8.0 g (solid), ≤ 30.0 mL (liquid) |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Power Consumption | 1700 W |
| Dimensions (L×W×H) | 580 × 430 × 750 mm |
| Brand | Yanrui |
|---|---|
| Model | ONH-530 |
| Origin | Chongqing, China |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Elemental Analyzer |
| Analysis Elements | O, N, H |
| Sample Types | Ferrous & non-ferrous metals, ceramics, superconductors, semiconductors, refractory materials (e.g., steel, iron, copper, zirconium, titanium, tantalum, niobium, rare earths, hard alloys) |
| Analysis Principle | Inert gas fusion coupled with infrared absorption (O, H) and thermal conductivity detection (N) |
| Analysis Range | Low-O: 0.0001–3.0 wt% |
| Optional high-O | 0.1–50.0 wt% |
| Low-N | 0.0001–3.0 wt% |
| Optional high-N | 0.1–60.0 wt% |
| H | 0.00001–0.50 wt% |
| Detection Limit | 0.1 ppm (O, N) |
| Precision | O/N: ±0.0001 wt% or RSD ≤ 1.0% |
| H | ±0.0002 wt% or RSD ≤ 2.0% |
| Analysis Time | < 180 s per sample |
| Pulse Electrode Furnace Power | 8.5 kW (max. 9 kW), operating current ≤ 1500 A, peak temperature > 3500 °C |
| Balance Resolution | 0.1 mg |
| Reagents | Magnesium perchlorate (H₂O trap), sodium hydroxide asbestos (CO₂ absorbent), copper oxide (CO → CO₂ converter) |
| Dimensions (W×D×H) | 700 × 770 × 820 mm |
| Net Weight | ~165 kg |
| Compliance | Designed to support GLP/GMP workflows |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YP-DYS2 |
| Price | USD 2,350 (FOB Qingdao) |
| Brand | Zhiyue Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KDN-380F |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | Solids 0.3–8.0 g |
| Distillation Time | 5–8 min per sample |
| Repeatability | ±0.3% RSD |
| Recovery Rate | ≥99.5% |
| Power Rating | 1300 W |
| Dimensions (L×W×H) | 420 × 340 × 710 mm |