Elemental Analyzer
Filter
Showing 121–150 of 531 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | ONH5000 |
| Power Supply | 8.0 kW Pulse Electrode Furnace |
| Max Furnace Temperature | >3500 °C |
| Detection Principles | Infrared Absorption (O), Thermal Conductivity (N, H) |
| Carrier Gases | He or N₂ |
| Compliance | ASTM E1019, ISO 14284, GB/T 11261–2022, GB/T 20123–2006 |
| Sample Form | Solid metallic & non-metallic materials |
| Measurement Elements | O, N, H (simultaneous or individual) |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0.003 mg – 50 mg N |
| Sample Weight | 0.5 mg – 1 g |
| Digestion/Combustion Time | 3–5 min per sample |
| Repeatability | < 0.5% RSD |
| Recovery Rate | > 99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 370 mm × 800 mm × 500 mm |
| Carrier Gas Options | Helium (high sensitivity) or Argon (cost-optimized) |
| Sample Forms | Solid, liquid, paste |
| Optional Autosampler | 64-, 100-, or 144-position pneumatic autosampler |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | KI 12/24 / KI 9/16 |
| Max. Heating Temperature | 650 °C / 600 °C |
| Heating Block Capacity | 4 × 500–750 mL flasks / 6 × 50–250 mL flasks |
| Voltage | 230 V AC |
| Frequency | 50–60 Hz |
| Power | 2320 W / 1800 W |
| Dimensions (W×D×H) | 650 × 380 × 950 mm |
| Weight | 35 kg / 25 kg |
| Compliance | Designed for ASTM D1142, ISO 5983-1, AOAC 984.13, and USP <467> residual solvent workflows |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | N-Realyzer |
| Principle | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.003–50 mg N |
| Repeatability | RSD < 0.5% |
| Max Sample Weight | 1 g |
| Recovery Rate | ≥99.5% |
| Power Consumption | 1400 W |
| Dimensions (L×W×H) | 600 × 550 × 722 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automatic |
| Repeatability | RSD < 0.5% |
| Sample Weight Capacity | up to 1 g |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Power Consumption | 1400 W |
| Dimensions (L × W × H) | 600 × 550 × 722 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | VAP500C |
| Instrument Category | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Detection Range | 0.1 mg N (absolute) |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | 10–160 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2300 W |
| Dimensions (L×W×H) | 960 mm × 600 mm × 1670 mm |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 200 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% RSD |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 300 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–200 mg |
| Distillation Time | 3.5 min |
| Repeatability | ±1% |
| Sample Weight Capacity | ≤5 g (solid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Linearity Range | 0.1–200 mg N |
| Water Consumption | ~3 L/min |
| Operating Voltage/Frequency | 230 V AC, 50/60 Hz |
| Net Weight | 34 kg |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 400 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤ ±1% RSD |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | VAPODEST 400 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automatic Steam Distillation System |
| Nitrogen Determination Range | 0.1–200 mg N |
| Distillation Time per Sample | 2–4 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity (Solid) | ≤5 g |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Cooling Water Flow Requirement | 5–7 L/min |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Model | Vapodest 450 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Nitrogen Detection Range | ≥0.1 mg N |
| Distillation Time | 3.5 min per sample |
| Repeatability | ≤±1% RSD |
| Sample Weight Capacity | ≤5 g (solid) / ≤20 mL (liquid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–200 mg N per sample |
| Steam Distillation Time | 3.5 min/sample |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | ≤5 g (solid) |
| Nitrogen Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MMS |
| Instrument Type | Online |
| Measurement Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Limit | ≤10 ng/m³ (CVAAS) |
| Repeatability | ≤1.0% (CVAAS) |
| Linearity Error | ±1% (CVAAS) |
| Sampling Points | 2–24 |
| Sample Line Purge Flow | 40–80 L/h per line |
| Measurement Cycle | 45 s–99 min (individually configurable per channel) |
| Standard Detector | VM-3000 (Range: 0.1–100, 1–1000, or 1–2000 µg/m³) |
| Trace Detector Option | UT-3000 (Range: 0.01–50 µg/m³) |
| Sample Flow Rate | ~80 L/h |
| Optical Wavelength | 253.7 nm UV absorption |
| Enclosure Rating | IP55 / NEMA 4X |
| Dimensions (W×H×D) | 553×600×500 mm to 800×2000×600 mm (configurable) |
| Weight | 35–175 kg (configuration-dependent) |
| Communication Interfaces | RS-232, Modbus RTU, Ethernet, optional fiber-optic cable |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 1200 |
| Detection Principle | Plasma Emission Spectroscopy |
| Measurement Range | 0–2 ppm, 0–10 ppm, 0–20 ppm, 0–100 ppm, 0–200 ppm N₂ in Ar |
| Accuracy | ±0.02 ppm (0–2 ppm range), ±0.25 ppm (0–10/0–20 ppm ranges), ±2.50 ppm (0–100/0–200 ppm ranges) |
| Sensitivity | ±0.01 ppm (Model 1200-A/1202-A), ±0.10 ppm (1200-B/1202-B), ±1.00 ppm (1200-C/1202-C) |
| Sample Flow Rate | 2 scfh (0.88 slpm) |
| Inlet/Outlet Fittings | 1/4" VCR inlet, 1/4" Swagelok outlet |
| Operating Temperature | 16–35 °C (60–95 °F) |
| Max Inlet Pressure | 10 psig |
| Measurement Cell Pressure | 6 psig |
| Normal Inlet Pressure | 2–7 psig |
| Output Signals | 4–20 mA analog, dry contact alarms |
| Power | 100 W, 115/230 VAC, 50/60 Hz |
| Dimensions | 13.34 × 42.23 × 37.15 cm |
| Weight | 11.3 kg |
| Brand | GOW-MAC |
|---|---|
| Origin | USA |
| Model | GOW-MAC 210 SA |
| Detection Principle | Flame Photometric Detection (FPD) |
| Detection Target | Total Sulfur in Gaseous or Liquid CO₂ |
| Detection Limit | <5 ppb for COS |
| Linear Dynamic Range | >3 orders of magnitude |
| Compliance | ISBT Methods 13 & 14 |
| Installation | Benchtop or Rack-Mountable |
| Operating Mode | Continuous or Discrete Flow |
| Calibration | Automated Onboard Calibration |
| Temperature Control | Factory-Set Constant-Temperature Detection Zone |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A), 1 isolated 4–20 mA output (max. 750 Ω), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered by external/flow signal |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Temp. | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Measurable Units | °dH, °f, ppm CaCO₃, mmol/L |
| Outputs | 4 programmable relay outputs (max. 250 V, 4 A), 1 × 4–20 mA (max. 750 Ω), 1 × RS485 |
| Inputs | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min, external trigger, or flow-signal synchronized |
| Rinse Duration | Configurable (15–1800 s) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Temp. | 10–40 °C |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered externally/flow-synchronized |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Units Supported | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Aqualysis 800A |
| Measurement Principle | Titrimetric Colorimetry |
| Measurement Time | 2–8 min (alkalinity-dependent) |
| Accuracy | ±2% of selected reagent upper limit |
| Repeatability | ±2% of selected reagent upper limit |
| Power Supply | 85–265 VAC, 47–63 Hz |
| Power Consumption | 25 VA (operational), 3.5 VA (standby) |
| Enclosure Rating | IP65 |
| Dimensions | 400 × 300 × 180 mm (H×W×D) |
| Weight | 4 kg |
| Display | Color LCD |
| Output Options | 4 programmable relay outputs (250 VAC, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface |
| Input Options | 2 programmable digital inputs (IN1: start analysis |
| IN2 | stop analysis) |
| Sampling Interval | 1–360 min (configurable) or triggered by external/flow signal |
| Rinse Duration | 15–1800 s (user-configurable) |
| Sample Water Requirements | pH 4–10 |
| Environmental Operating Range | 10–40 °C |
| Compatible Units | °dH, °f, ppm CaCO₃, mmol/L |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Aqualysis 800A |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (depending on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | English & Chinese |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS), configurable for measured value or temperature |
| Communication | RS485 Modbus RTU |
| Enclosure Rating | IP67-rated sealed housing |
| Electrode Compatibility | BSens710 (F⁻), BSens720 (Cl⁻), BSens730 (NH₃-N) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | PM 8202I |
| Pricing | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM 8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20,000 ppm F⁻ |
| Resolution | 0.0 / 0.1 / 1 ppm (user-selectable) |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm (dependent on range) |
| Temperature Compensation | –10 to 130 °C (manual or automatic |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Interface Language | English & Chinese |
| Data Storage Capacity | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Analog Outputs | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy ±0.1% FS, configurable for concentration or temperature) |
| Digital Communication | RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, moisture- and gas-resistant) |
| Electrode Compatibility | Bsens710 Fluoride ISE, Bsens720 Chloride ISE, Bsens730 Ammonia ISE |
| Calibration | Manual or scheduled two-point calibration with password-protected access |
| Brand | GreenPrima |
|---|---|
| Origin | UK |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PM8202I |
| Price | Upon Request |
| Measurement Range | 0.00–20000 ppm |
| Resolution | 0.0 / 0.1 / 1 ppm |
| Accuracy | ±0.01 / ±0.1 / ±1 ppm |
| Temperature Compensation | –10 to 130 °C (manual/automatic, NTC30K or PT1000) |
| Operating Temperature | –10 to 70.0 °C |
| Storage Temperature | –20 to 70.0 °C |
| Display | Backlit large-dot-matrix LCD |
| Language | Chinese/English |
| Data Storage | 600,000 records |
| Power Supply | 90–260 VAC, 50/60 Hz or optional 24 VDC |
| Output | Two isolated 4–20 mA outputs (max. loop resistance 500 Ω, accuracy 0.1% F.S.), RS485 Modbus RTU |
| Enclosure Rating | IP66/IP67 (fully sealed, waterproof & gas-tight) |
| Electrode Compatibility | Bsens710 (F⁻), Bsens720 (Cl⁻), Bsens730 (NH₃-N) |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PROCON3000 |
| Pricing | Available Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | GreenPrima |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PROCON5000 |
| Price | Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Polymetron 9610sc |
| Price | Upon Request |
| Measurement Range | 0.5–5000 µg/L as SiO₂ |
| Accuracy | ±1% or ±1 µg/L (0–500 µg/L), ±5% (500–5000 µg/L) |
| Repeatability | ±0.5 µg/L or ±1% (whichever is greater) |
| Detection Limit | 0.5 µg/L |
| Response Time | ~9 min at 25°C |
| Sample Pressure | 2–87 psi |
| Sample Temperature | 5–50°C |
| Flow Rate | 55–300 mL/min |
| Sampling Channels | 1, 2, 4, or 6 |
| Cycle Time | ~15 min |
| Reagent Consumption | ~2 L per reagent per 90 days |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Output Signals | Four 4–20 mA isolated analog outputs |
| Enclosure Rating | IP56 |
| Dimensions (H×W×D) | 804 × 452 × 360 mm |
| Weight | 20 kg (empty), 36.3 kg (fully loaded with reagents) |
| Mounting Options | Wall-mount, panel-mount, or benchtop |
| Tubing | Sample & bypass drain: 6 mm |
| Air purge inlet | 6 mm (1/4 in) |
| Chemical waste line | 9.5 mm (3/8 in) |
| Compatible Controllers | SC200, SC1000 |