Elemental Analyzer
Filter
Showing 61–90 of 531 results
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GALILEO ON |
| Price | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G4 ICARUS Series 2 |
| Detection Principle | High-frequency induction combustion coupled with UV absorption (SO₂) and infrared absorption (CO₂) |
| Analysis Time | < 60 s per cycle including auto-cleaning |
| Filter Pore Size | 3 µm |
| Signal-to-Noise Ratio (SO₂) | 10× improvement vs. conventional IR |
| Dynamic Range (SO₂) | 50-year linear calibration stability |
| Compliance | ASTM E1019, ISO 15350, DIN 51018, USP <231>, GLP/GMP-ready data integrity architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G4 PHOENIX DH |
| Detection Principle | Thermal Desorption Mass Spectrometry (TDMS) & Thermal Conductivity Detection (TCD) |
| Detection Limit | <1 ng/g (with optional quadrupole MS) / <50 ng/g (standard TCD) |
| Furnace Max Temp | 900 °C (IR-heated, low thermal mass) |
| Sample Chamber Diameter | 30 mm |
| Calibration | 10-volume automated gas standard system |
| Compliance | Fully compatible with ISO 3690, AWS A4.3, ASTM E1442, EN ISO 17025 |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G6 LEONARDO |
| Technique | Inert Gas Fusion (IGF) with Thermal Conductivity Detection (TCD) for H/N |
| Detection Limits | < 0.1 ppm (ng/g) for H and N (1 g sample) |
| Maximum Furnace Temperature | > 3000 °C (water-cooled electrode furnace) |
| Carrier Gas | Argon (He-free operation) |
| Compressed Air Consumption | 0 L/min |
| Compliance | ASTM E1019, ISO 14284, ISO 15350, USP <233>, GLP/GMP-ready software architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | G8 GALILEO |
| Detection Principle | Inert Gas Fusion (IGF) coupled with Thermal Conductivity Detection (TCD) and Mass Spectrometry (MS) |
| Mass Range | 0–100 amu/mz |
| Detection Limits | <1 ppb (ng/g) for H, O, N (1 g sample) |
| Measurement Method | Direct gas-phase analysis via Smart Molecule Sequence™ |
| Furnace Options | Water-cooled graphite electrode furnace with FusionControl™ real-time non-contact temperature monitoring |
| Optional External IR Furnace | For diffusion hydrogen analysis per ISO 360 and AWS A4.3 |
| Compliance | Designed for GLP/GMP environments |
| Automation | Fully automated sample/crucible handling, electrode cleaning, and 10-step gas dosing calibration |
| MS Configuration | Industrial-grade quadrupole mass spectrometer optimized for H₂, N₂, O₂, Ar, and H₂O detection with reference channel stabilization |
| Particle Filtration | Integrated high-capacity dust collector + inline particulate filter |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | S1 TITAN |
| Detection Principle | Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Elemental Range | Ti to Bi (including Au, Ag, Pt, Pd, Rh, Ru, Ir, Ni, Cu, Fe, Zn, Sn, Pb, Cd, Cr, Co, Mn, Sb, Ti) |
| Detector | SharpBeam™ Optimized Silicon Drift Detector (SDD) with Optional Pin-Proof Shield™ |
| X-ray Tube | 50 kV Max Excitation |
| Display | High-Contrast LCD Touchscreen |
| Optional Accessories | Integrated CCD Color Camera, Micro-Spot Collimation, Desktop/Tripod Mount, Remote Control Interface |
| Compliance | Designed for GLP/GMP environments |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Type | Total Reflection X-ray Fluorescence (TXRF) Spectrometer |
| Model | Blood Heavy Metal Analyzer |
| Element Range | Al (13) to U (92) |
| Detection Limit | 2 pg |
| Sample Volume (Liquid/Suspension) | 1–50 µL |
| Sample Mass (Powder) | <10 µg |
| Detector | 4th-Generation XFlash® SDD Silicon Drift Detector |
| Cooling | Peltier (No Liquid Nitrogen Required) |
| Energy Resolution | <160 eV at Mn Kα (100 kcps) |
| Automation Options | 1-position or 25-position Auto-sampler |
| Compliance | ASTM D7782, ISO 17294-2, USP <232>/<233>, GLP/GMP-ready data integrity features |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2100 W |
| Dimensions (L×W×H) | 320 × 400 × 730 mm |
| Weight | 23 kg |
| Electrical Supply | 220–240 VAC ±10%, 50/60 Hz |
| Safety Certifications | CE, CSA |
| Repeatability | RSD <0.8% |
| Nitrogen Detection Range | 0.02–220 mg N |
| Cooling Water Management | Intelligent Flow Control with Auto-Shutoff |
| Steam Power Control | Adjustable 10–100%, Programmable Steam Gradient |
| Safety Systems | Dual-flow cooling water sensor, steam generator pressure monitoring, sample tube presence detection, transparent safety shield with interlock, reagent/waste/water level sensing |
| Voltage Stabilization | Integrated line regulator for consistent steam output |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Kjeldahl Nitrogen Determinator |
| Model | K-375 |
| Nitrogen Range | 0.02–200 mg N |
| Distillation Time | 1–9999 min (typical: 4 min/sample) |
| Repeatability | RSD ≤ 1% |
| Sample Weight Capacity | ≤ 5 g (solid), ≤ 200 mL (liquid) |
| Nitrogen Recovery Rate | ≥ 99.5% |
| Max Power Consumption | 2.4 kW |
| Dimensions (L×W×H) | 458 × 670 × 431 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Manufacturer | BUCHI AG |
| Product Type | Automated Sample Handler (KjelSampler) |
| Model | K-376 / K-377 |
| Instrument Category | Kjeldahl Nitrogen Analyzer Accessory |
| Nitrogen Determination Range | 0.02 – 200 mg N |
| Distillation Time per Sample | ≤240 s |
| Repeatability | RSD < 1 % |
| Sample Weight Capacity | Solids ≤ 5 g, Liquids ≤ 200 mL |
| Nitrogen Recovery Rate | >99.5 % (for 1–200 mg N) |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 505 × 750 × 655 mm |
| Brand | BUCHI |
|---|---|
| Origin | Switzerland |
| Product Category | Imported Instrument |
| Compliance Standards | AOAC, EPA, ISO, DIN |
| Automation Options | Manual to Fully Automated |
| Safety Features | Integrated Steam Trap, Overpressure Protection, Acid Fume Containment |
| Service Support | Global Technical Assistance, Method Validation Guidance, GLP-Compliant Documentation |
| Brand | BUCK |
|---|---|
| Origin | USA |
| Instrument Type | Benchtop Laboratory Analyzer |
| Principle | Cold Vapor Atomic Absorption Spectrometry (CVAAS) |
| Detection Wavelength | 253.7 nm |
| Detection Limit | 10 pg/L (ppt) under controlled clean-lab conditions |
| Sample Cell Path Length | 400 mm fused silica window |
| Background Correction | Online Deuterium Lamp (D₂) |
| Output Interfaces | RS-232 serial port, analog output (0–1 V or 4–20 mA) |
| Sample Introduction | Air-driven purge-and-trap with integrated desiccant and charcoal filtration |
| Dimensions (W×D×H) | 991 × 279 × 305 mm |
| Weight | 21 kg |
| Power Requirement | 220 V, 50 Hz, 80 W |
| Compliance | Fully compliant with U.S. EPA Method 245.1 |
| Calibration | Up to 8-point linear or quadratic calibration curves |
| Operational Features | Quick-Purge button for flow-cell cleaning, Peak-Picker peak-area integration, GLP-ready data handling |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Range | 0.1–200 mg N |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% RSD |
| Sample Mass | 1 g |
| Recovery Rate | >99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 × 390 × 697 mm |
| Linear Range | 0.1–200 mg N |
| Brand | C. Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Type | Kjeldahl Nitrogen Determinator |
| Model | VAPODEST® 200 |
| Automation Level | Semi-Automatic |
| Nitrogen Range | 0.1–200 mg |
| Distillation Time | 2–4 min per sample |
| Repeatability | ±1% |
| Sample Weight (solid) | ≤5 g |
| Recovery Rate | 99.5% |
| Power Consumption | 2200 W |
| Dimensions (L×W×H) | 527 mm × 390 mm × 697 mm |
| Compatible Acid Titration Range | Universal (any standard acid concentration) |
| Brand | Cambridge Sensotec |
|---|---|
| Origin | United Kingdom |
| Model | Rapidox 6100 |
| Gas Measurement Range | SF₆ 0–100% (±0.5% FS), H₂O −60 to +20 °C dew point (±2 °C), SO₂ 0–100 ppm (±2%), HF 0–25 ppm (±1 ppm), CF₄ 0–80% (±1%), O₂ 0–100% (±1%) |
| Analysis Time | 3–5 minutes per sample |
| Enclosure | IP66-rated Peli™ carry case |
| Weight | 17 kg |
| Internal Compressor Output | 10 bar |
| Battery Life | Up to 8 hours (Li-ion) |
| Display | 7-inch full-color touchscreen |
| Data Export | USB flash drive (Excel-compatible .csv format) |
| Onboard Thermal Printer | Yes |
| Language Options | Multi-language UI with password-protected access |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Costech ECS 4024 |
| Price Range | USD 13,500 – 27,000 |
| Brand | DAJ |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | WGJ-III |
| Pricing | Upon Request |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | AKN-3240 |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.01–240 mg N per sample |
| Distillation Time | 0–9 min/sample |
| Titration Precision | RSD < 0.0012 µL/step |
| Minimum Titration Volume | 1–20 µL/step (auto-adjusted based on standard acid concentration) |
| Recovery Rate | >99.5% |
| Power Adjustment Range | 0–1500 W |
| Linearity | RSD <1.0% across 1× to 4× sample mass (same matrix) |
| Repeatability (RSD) | <0.5% |
| Digestion Tube Compatibility | Ø42 × 300 mm (supports both 300 mL and 650 mL tubes) |
| Data Storage Capacity | ≥200,000 sample records (≥7 years at typical lab throughput) |
| Compliance | Supports audit-trail-enabled operation per GLP/GMP requirements |
| Origin | Hunan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | DHF83 |
| Price Range | USD 1,400 – 7,200 |
| Origin | Italy |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | EasyChem Plus |
| Price | Upon Request |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | acquray TOC |
| Detection Principle | High-Energy UV-Persulfate Wet Oxidation |
| LOD (TOC in Water) | 2 ppb |
| Sample Types | Liquid (aqueous), Solid, Suspended Particulates |
| Optional Modules | Solid TOC, TN (Total Nitrogen), TP (Total Phosphorus) |
| Automation | Optional Autosampler (up to 109 positions) |
| Compliance | Designed for ISO 8245, ASTM D5903, USP <643>, EPA Method 415.3 & 9060A |
| Calibration | Fully Automated Predefined Calibration Sequences |
| Maintenance | Predictive Alert System with Access-Optimized Component Layout |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | rapid CS cube |
| Detection Principle | High-Temperature Combustion + Non-Dispersive Infrared (NDIR) Detection |
| Sample Throughput | Up to 60 samples unattended (standard), optional 80/120-position autosamplers |
| LOD (S in coal) | ≤2 ppm |
| Warranty | 10 years on combustion furnace and thermal conductivity detector (TCD) |
| Compliance | Designed for ISO 15594, ASTM D4294, ASTM D7622, and USP <281> carbon/sulfur testing environments |
| Software | vario LINK with full audit trail, 21 CFR Part 11-compliant user management and electronic signature support |
| Optional Modules | Chlorine detection (solid-state electrochemical sensor), TOC/TIC dual-module configuration |
| Origin | Germany |
|---|---|
| Manufacturer | Elementar Analysensysteme GmbH |
| Type | vario Series |
| Compliance | ASTM D5373, ISO 10694, USP <28>, EPA Method 405.1, EN 15148 |
| Detection Range | C/H/N/S/O/Cl |
| Sample Mass | 0.1 mg – 800 mg |
| Combustion Temperature | up to 1200 °C (1800 °C peak with tin foil) |
| Gas Supply | He or Ar carrier gas, O₂ for combustion |
| Data System | Windows-based software with audit trail, 21 CFR Part 11 optional |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CHS-580A |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | Vertical Resistance Furnace (Ceramic Tube, Max. 1550 °C, Adjustable in 1 °C Increments) |
| Sample Capacity | Up to 500 mg (Including Heterogeneous Materials) |
| Analysis Time | 60–180 s per Sample |
| Combustion Power | Up to 2000 W |
| C Range | 0.005–100 wt% |
| H Range | 0.01–15 wt% |
| S Range | 0.005–20 wt% (Customizable Ranges Available) |
| Autosampler Options | 36-position or 130-position Crucible Carousels |
| IR Cell Enhancement | Gold-Coated Optical Path for Extended Lifetime and Compatibility with Halogen- or Acid-Containing Samples |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CS-580A |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | Vertical Resistance Furnace with Ceramic Tube |
| Max. Furnace Temperature | 1550 °C (adjustable in 1 °C increments) |
| Sample Weight Capacity | Up to 500 mg |
| Analysis Time | 60–120 s per sample |
| Combustion Power Output | Up to 2000 W |
| Carbon Range | 0.005–100 wt% (customizable) |
| Sulfur Range | 0.005–20 wt% (customizable) |
| Detector Configuration | Up to four gold-coated NDIR cells |
| Autosampler Options | 36-position or 130-position ceramic crucible carousel |
| Compliance | Designed for ISO 9556 (steel), ISO 4935 (ferrous alloys), ASTM E1019, and USP <231> elemental impurity testing workflows |
| Brand | Eltra |
|---|---|
| Origin | Germany |
| Model | CS-i |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace (2.2 kW, up to 2,000 °C) |
| Measurement Range | C: 0.6 ppm – 6.0 wt%, S: 0.6 ppm – 4.5 wt% |
| Sensitivity | C: 0.1 ppm, S: 0.1 ppm |
| Accuracy | ±0.2 ppm |
| Analysis Time | 40 s |
| Detector Configuration | Up to 4 tunable infrared cells (including optional gold-plated cells for halogen- or acid-resistant applications) |
| Compliance | Designed for GLP/GMP environments |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CW-800 |
| Measurement Principle | Infrared Absorption |
| Heating System | Resistance Furnace (up to 1000 °C, adjustable in 1 °C increments) |
| Sample Introduction | Quartz Boat |
| Carrier Gas | Nitrogen (standard) |
| Detection | Dual Independent IR Cells (CO₂ and H₂O) |
| Cell Material | Gold-Plated IR Cells |
| Calibration | Single-Point and Multi-Point |
| Gas Flow Control | Electronic Mass Flow Controller |
| Compliance | Designed for GLP/GMP environments |
| Software | Multilingual, customizable reporting, real-time process monitoring |
| Analysis Time | ~2–3 min per sample |
| Sample Form | Solids (powders, granules, pellets) |
| Maintenance | Maintenance-free gas path |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CW-800M |
| Measurement Principle | Infrared Absorption |
| Heating System | Resistance Furnace |
| Temperature Range | Up to 1000 °C (adjustable in 1 °C increments) |
| CO₂ Measurement Range | 0–70 % |
| H₂O Measurement Range | 0–20 % |
| Sensitivity | 0.0001 % for both CO₂ and H₂O |
| Accuracy | ±0.02 % |
| Analysis Time | 2–30 minutes |
| Detection Cells | Dual independent gold-coated IR cells |
| Atmosphere Options | O₂ or inert gas (e.g., N₂) |
| Programmable Temperature Steps | Up to 5 per method |
| Compliance | Designed for GLP/GMP environments |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CHS-r |
| Measurement Principle | Infrared Absorption (CO₂, SO₂, H₂O detection) |
| Furnace Type | Horizontal Resistance Furnace with Ceramic Tube |
| Temperature Range | 600 °C to 1550 °C |
| Sample Weight Capacity | Up to 500 mg |
| Detection Range | 20 ppm to 100 wt% |
| Compliance | ASTM D5373, ASTM D7289, ISO 11725, ISO 20362, DIN 51721, EN 15407 |
| Key Features | Triple IR detection cells (C, H, S), gold-plated IR cells, low-blank sample inlet, oxygen flow control with electronic mass flow meter |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ELEMENTRAC CN-r |
| Analysis Principle | Dumas Combustion Method |
| Sample Throughput | <3 min per sample |
| Detection | Total Carbon (C) and Total Nitrogen (N), Protein Calculation (N × conversion factor) |
| Automation | Integrated Autosampler with RFID/Barcode Sample Recognition |
| Control System | Built-in Industrial PC with Touchscreen Interface |
| Gas Supply | High-Purity Oxygen Flow |
| Catalyst | Chromium-Free Oxidation Catalyst |
| Compliance | Designed for GLP/GMP environments |
| Sample Forms | Solids, Powders, Liquids, Pastes |
| Maintenance | Full consumables replacement in <20 min |