Elemental Analyzer
Filter
Showing 91–120 of 531 results
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | CS-d |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace & Resistance Furnace |
| Carbon Range | 0.0012–70 mg |
| Sulfur Range | 0.0006–30 mg |
| Sensitivity | 0.01 ppm |
| Accuracy | ±0.2 ppm or ±0.5% RSD |
| Analysis Time | 45 s |
| Brand | Eltra |
|---|---|
| Origin | Germany |
| Model | CS-r |
| Measurement Principle | Infrared Absorption |
| Heating System | Horizontal Resistance Furnace (600–1550 °C) |
| Max. Sample Weight | 500 mg |
| Detection Range | 20 ppm to 100% |
| IR Cells | Up to 4 |
| Compliance | ASTM, DIN, EN, ISO |
| Optional Elements | C, S, H (configurable combinations) |
| Sample Port | Optimized Low-Blank Design |
| Detector Cell | Gold-Plated IR Cells |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | OH-p 2 |
| Instrument Type | Oxygen/Hydrogen Analyzer |
| Analysis Time | 120–180 s |
| Pulse Furnace Power | Up to 8,500 W |
| Detection Principle | Non-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Hydrogen |
| Sample Form Compatibility | Solid rods, granules, powders |
| Max. Sample Weight | 2 g |
| Compliant Standards | ASTM E1019, DIN EN 3976 |
| Carrier Gas Options | Argon (economical), Helium |
| Optional | Automatic Graphite Crucible Cleaner |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | OH-p |
| Instrument Type | Oxygen/Hydrogen Analyzer |
| Analysis Range | Oxygen 0.1 ppm – 2.0 wt%, Hydrogen 0.01 ppm – 1000 ppm |
| Analysis Time | Oxygen 85 s, Hydrogen 100 s |
| Furnace Max Temperature | 3000 °C |
| Furnace Power | 8.5 kW |
| Detection Principle | Inert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity Detection (H) |
| Sample Form | Solid, granular, or chip-shaped inorganic materials (e.g., metals, ceramics, refractories) |
| Calibration | Single-point and multi-point linear regression |
| Cooling Options | Tap water, recirculating chiller, or heat exchanger |
| Compliance Support | ASTM E1019, ISO 14284, ISO 22371, USP <232>/<233>, GLP/GMP-ready data audit trail |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ON-p 2 |
| Analysis Time | 120–180 s |
| Pulse Furnace Power | Up to 8.5 kW |
| Maximum Furnace Temperature | 3000 °C |
| Sample Weight Capacity | Up to 2000 mg |
| Detection Principle | Non-Dispersive Infrared (NDIR) for Oxygen, Thermal Conductivity Detection (TCD) for Nitrogen |
| Compliance | ASTM E1019, DIN EN 3976 |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ON-p |
| Instrument Type | Oxygen and Nitrogen Analyzer |
| Analysis Range | 0.1 ppm – 2% |
| Analysis Time | 90 s |
| Detection Limit (N) | 0.01 ppm |
| Furnace Max Temperature | 3000 °C |
| Furnace Power | 8.5 kW |
| Detection Principle | Inert Gas Fusion Coupled with IR Absorption (O) and Thermal Conductivity (N) |
| Carrier Gas Options | He or Ar |
| Software | ELTRA Analytical Software (Supports CFR 21 Part 11 Compliance, Audit Trail, Multi-Point Calibration, Report Export, Comment Annotation) |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | ELEMENTRAC ONH-p 2 |
| Analysis Elements | Oxygen, Nitrogen, Hydrogen |
| Analysis Range | O: 0.1 ppm–2.0 wt% |
| N | 0.1 ppm–2.0 wt% |
| H | 0.01 ppm–1000 ppm |
| Detection Limits | O: 0.1 ppm |
| N | 0.1 ppm |
| H | 0.01 ppm |
| Analysis Time | 120–180 s (typical) |
| Pulse Furnace Power | up to 8.5 kW |
| Maximum Furnace Temperature | 3000 °C |
| Detection Principle | O by Non-Dispersive Infrared (NDIR) Absorption |
| Carrier Gases | He (99.995% purity), N₂ or Ar (99.995% purity), 2–4 bar |
| Power Supply | 3-phase, 400 V, 50/60 Hz, max. 8.5 kVA |
| Dimensions (W×H×D) | 56 × 78 × 64 cm |
| Weight | ~165 kg |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | H-500 |
| Instrument Type | Hydrogen Analyzer |
| Analysis Range (Low-H) | 0.1 ppm – 200 ppm |
| Analysis Range (High-H) | 10 ppm – 2% |
| Accuracy (Low-H) | ±0.1 ppm or ±1% |
| Accuracy (High-H) | ±2 ppm or ±1% |
| Sensitivity (H) | 0.01 ppm |
| Analysis Time | 2–3 min |
| Maximum Sample Mass | 10 g |
| Sample Dimensions | ≤ 0.8 × 6 cm |
| Furnace Max Temperature | 1000 °C (1 °C adjustable) |
| Carrier Gas | High-purity N₂ |
| Detector Configuration | Dual thermal conductivity cells with differential sensitivity |
| Brand | ELTRA |
|---|---|
| Origin | Germany |
| Model | SURFACEC-800 |
| Measurement Principle | Infrared Absorption |
| Heating System | Resistance Furnace |
| Measurement Range (Low) | 0.1–100 µg C/cm² |
| Measurement Range (High) | 1–1,000 µg C/cm² |
| Analysis Time | 60–90 s |
| Maximum Furnace Temperature | 1000 °C (1 °C adjustable) |
| Carrier Gas | Oxygen |
| Detection System | Dual Independent IR Cells |
| Calibration | Certified Reference Materials or Standard Gases |
| Flow Control | Electronic Mass Flow Controller |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | RLTD-05 / RLTD-10 |
| Pricing | Available Upon Request |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS CL |
| Price | Upon Request |
| Measurement Principle | Coulometric Titration (Absolute Method) |
| Sample Types | Liquids (including viscous), Gases (incl. LPG), Solids, Slurries, Polymers, Fuels, Environmental Matrices |
| Compliance | ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, GB/T 18612, SH/T 1757, GB/T 23971-B, SH/T 0677-A, UOP 779, ISO 9562, NF EN 12260, NF EN 14077 |
| Detection Range | 0.1 ppm to 80 wt% Cl (matrix-dependent, no dilution required) |
| Electrolyte Options | Three grades for low-, medium-, and high-concentration applications |
| Dual-Cell Architecture | Two independent coulometric titration cells |
| Furnace | F2-type high-temperature combustion furnace, max. 1100 °C |
| Carrier Gases | O₂ (99.998%, 3 bar) and Ar (99.995%, 3 bar) |
| Sample Introduction | 20–80 µL liquid |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 66 × 83 × 56 cm |
| Weight | 32 kg |
| Warranty | 5-year hardware warranty |
| Language Interface | English, French, Spanish, German, Russian, Chinese |
| Safety Features | Automated acid-free dry/wash system, light-shielded semi-pressurized titration cell, integrated gas flow control and pressure monitoring |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS N |
| Measurement Element | Nitrogen |
| Measurement Principle | Chemiluminescence Detection |
| Detection Limit | 5 ppb |
| Quantitation Range | 10 ppb – 10 % |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS S |
| Measurement Element | Sulfur |
| Measurement Principle | Ultraviolet Fluorescence (UVF) |
| Detection Limit | 5 ppb |
| Quantitation Limit | 10 ppb |
| Measurement Range | 5 ppb – 10% w/w |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Gas Requirements | O₂ ≥99.998% at 3 bar, Ar ≥99.995% at 3 bar |
| Power Supply | 110/230 V, 50/60 Hz, 800 W |
| Dimensions (W×H×D) | 51 × 78 × 56 cm |
| Weight | 32 kg |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HELIOS S&N |
| Measurement Elements | Sulfur (S), Nitrogen (N) |
| Measurement Principle | UV Fluorescence (S) / Chemiluminescence (N) |
| Detection Limit | 5 ppb (S), 5 ppb–10% (N) |
| Quantitation Range | 10 ppb–10% (S & N) |
| Furnace Temperature Range | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Display | 7-inch touchscreen interface |
| Languages | English, French, Spanish, German, Russian, Chinese |
| Compliance | ASTM D5453, D6667, D7183, D7551, D4629, D6069, D5762 |
| Brand | Eraly & Associés |
|---|---|
| Origin | France |
| Model | HELIOS SN&CL |
| Measurement Elements | Sulfur (S), Nitrogen (N), Chlorine (Cl) |
| Measurement Principles | UV Fluorescence (S), Chemiluminescence (N), Coulometric Titration (Cl) |
| Detection Limits | 5 ppb (S), 5 ppb–10% (N), 50 ppb–80+% (Cl) |
| Quantitation Ranges | 10 ppb–100 ppm (S), 10 ppb N–10% (N), <0.1 ppm–80+% (Cl) |
| Combustion Furnace Temperature | Up to 1100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Volume | 20–80 µL (liquid), 10 mL (gas), 20 µL (LPG) |
| Carrier Gases | O₂ (99.998%, 3 bar), Ar (99.995%, 3 bar) |
| Built-in Languages | English, French, Spanish, German, Russian, Chinese |
| Brand | ERALYTICS |
|---|---|
| Origin | Austria |
| Model | ERAOIL |
| Type | Rotating Disk Electrode Optical Emission Spectrometer (RDE-OES) |
| Detection Principle | Arc Spark Optical Emission Spectrometry |
| Measurement Time | ≤30 s per sample |
| Elements Quantified | Up to 32 metallic elements |
| Detection Limit (LOD) | Sub-ppm for most elements (standard configuration) |
| Sample Types | Lubricants, fuels, coolants, process water, hydraulic fluids |
| Compliance | ASTM D6728, ASTM D6595, NB/SH/T 0865 |
| Integrated System | Built-in 10-inch color touchscreen, embedded industrial PC, automated electrode dresser, and active ventilation unit |
| Dimensions & Portability | Compact benchtop footprint |
| Sample Preparation | None required — direct liquid analysis |
| Gas Requirement | None (no carrier gas, no plasma gas) |
| Brand | ESI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CS995 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | 20 MHz High-Frequency Induction Furnace |
| Power Output | 2200 W |
| Carbon Range | 0.00006–6.0000 wt% (extendable to 99.999%) |
| Sulfur Range | 0.00006–0.5000 wt% (extendable to 99.999%) |
| Sensitivity | 0.001 ppm for both C and S |
| Precision | RSD < 0.5% |
| Compliant with GB/T 20123–2006 and ISO 15350 | 2000 |
| Analysis Time | 20–100 s (typical: 35 s) |
| Sample Mass (steel standard) | 0.5 g nominal |
| Dust Filter Pore Size | 0.4 µm metallic sintered filter |
| Optical Path | Gold-plated CO₂/SO₂ absorption cells |
| IR Source | Platinum-based thermal emitter (800 °C operating temperature) |
| Detection Wavelengths | CO₂ at 4.26 µm, SO₂ at 7.4 µm |
| Modulation Frequency | 64 Hz |
| Data Acquisition | 24-bit ADS1224 ADC, 20 Hz real-time sampling |
| Communication | USB 2.0 host interface + Agilent 1521/2521 optical fiber link between furnace and detector |
| Software Platform | Windows-based Delphi application with ACCESS database backend |
| Brand | ESI |
|---|---|
| Model | EDX9000A |
| Element Range | Na (11) – U (92) |
| Detection Limit | 1 ppm |
| Quantification Range | 1 ppm – 99.99 wt% |
| Excitation Source | 50 W Rh-target X-ray tube, 0–50 kV |
| Detector | AmpTek high-resolution silicon drift detector (SDD) |
| DPP Analyzer | 4096-channel digital pulse processor |
| Sample Chamber Dimensions | 460 × 310 × 95 mm |
| Vacuum Chamber | Φ150 mm × 75 mm |
| Instrument Dimensions | 560 × 380 × 410 mm |
| Weight | 45 kg |
| Operating Environment | −10 °C to 35 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3017 |
| Analysis Principle | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Determinator |
| Nitrogen Range | 0–100% |
| Repeatability | ±0.5% RSD |
| Sample Mass Capacity | ≤5 g (solid) |
| Dimensions (L×W×H) | 480 mm × 480 mm × 600 mm |
| Brand | EuroVector |
|---|---|
| Origin | Italy |
| Model | EA3100 |
| Measurable Elements | C, H, N, S, O |
| Analysis Time | CN ≤ 3 min |
| Detection Limit | ppm-level |
| Measurement Accuracy | ±0.1% (relative) |
| Sample Introduction | Tin or silver capsules, filled to capacity |
| Detector Type | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | TurboFlash dynamic combustion up to 1800 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | FASP-01 |
| Pricing | Available Upon Request |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FASP-ECO |
| Pricing | Available Upon Request |
| Key | Brand: Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Model | TY-Ca08 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | AC 220 V, 50 Hz |
| Operating Temperature Range | 5–40 °C |
| Power Consumption | ≤30 W |
| Dimensions (W×D×H) | 468 × 368 × 136 mm |
| Weight | 13.8 kg |
| Analysis Time | 15 × n seconds (n ∈ ℕ) |
| recommended default | 30 s |
| CaO Quantification Range | 0.1–100 wt% |
| CaO Precision (Standard Deviation) | ≤0.09% |
| Sample Preparation | Manual toggle-type tablet press with adjustable die cavity height |
| Compliance | Designed for routine industrial QA/QC per ISO 29581-1 (cement), ASTM C114 (standard test methods for chemical analysis of hydraulic cement) |
| Brand | FocusSens / Beijing Michem Technology Ltd. |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | MiX5 |
| Pricing | Available Upon Request |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1 – 210 mg N |
| Distillation Flow Rate | ~40 mL/min |
| Repeatability | ≤1% RSD |
| Recovery Rate | >99.5% (for 1–200 mg N) |
| Power Consumption | 3000 W |
| Dimensions (L×W×H) | 500 mm × 480 mm × 760 mm |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | Kjeltec™ 9 Distillator |
| Instrument Type | Kjeldahl Nitrogen Distillation Unit |
| Automation Level | Semi-Automatic |
| Nitrogen Determination Range | 0.1–210 mg N |
| Distillation Time | 3.5 min |
| Repeatability | ±1% RSD |
| Sample Weight Capacity | Solids: 0.2–2 g |
| Semi-solids | 2–5 g |
| Liquids | 10–25 g |
| Nitrogen Recovery Rate | >99.5% |
| Power Rating | 3000 W |
| Dimensions (L×W×H) | 500×480×790 mm |
| Brand | FOSS |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Automated Kjeldahl Nitrogen Determinator |
| Automation Level | Fully Automated |
| Model | SINO KT8400 |
| Compliance Standards | AOAC, EPA, DIN, ISO |
| Sample Throughput | Compatible with 20-position autosamplers (e.g., FOSS 8420/8460) |
| Safety Features | SAFE™ steam-controlled distillation, interlocked transparent safety door, integrated temperature-controlled distillate cooling |
| Software Options | FOSS Compass LIMS-ready software with GLP-compliant audit trail, network printer/tare balance integration |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Model | CS5000 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) Absorption |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.00001–12.0 wt% |
| Sulfur Range | 0.00001–45.0 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1.0 ppm (C/S) or RSD ≤ 0.5% (C), ≤ 1.0% (S) |
| Analysis Time | 20–40 s |
| Dimensions | 650 × 790 × 920 mm (W×D×H) |
| Weight | 150 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, voltage fluctuation < ±0.2% |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Product | Yes |
| Model | CS5000 |
| Measurement Principle | Infrared Absorption Spectroscopy |
| Heating System | High-Frequency Induction Furnace |
| Carbon Range | 0.00001–12 wt% |
| Sulfur Range | 0.00001–45 wt% |
| Sensitivity | 0.000001 wt% |
| Precision | ±1.0 ppm |
| Analysis Time | 20–40 s |
| Furnace Output Power | Adjustable (0–2.5 kW typical for HF induction) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ONH5000 |
| Instrument Type | Oxygen-Nitrogen-Hydrogen Analyzer |
| Oxygen Range | 0.00001–3.0 wt% |
| Nitrogen Range | 0.00001–3.0 wt% |
| Hydrogen Range | 0.00000–0.25 wt% |
| Oxygen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Nitrogen Precision | ±0.0001 wt% or RSD ≤ 1.0% |
| Hydrogen Precision | ±0.00002 wt% or RSD ≤ 2.0% |
| Sensitivity | 0.000001 wt% |
| Typical Analysis Time | 120–180 s (including purge, delay, and measurement) |