BrandElementar
OriginGermany
Modelvario MACRO cube
Measured ElementsC, H, N, S, O
Sample Capacityup to several hundred mg per analysis
C/N Ratio Toleranceup to 7000:1
Detection Limit for Sdown to 2 ppm (with optional IR detector)
Standard Autosampler60-position
Detector OptionsThermal Conductivity Detector (TCD), optional Infrared (IR) detector for S, TIC, O, Cl
Patented TechnologyAPT (“Adsorption Purge and Trap”) gas separation system
Furnace & TCD Warranty10 years
ComplianceDesigned for ASTM D5373, ISO 19786, ISO 29540, EN 15407, USP <281>, EPA Method 5050
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario MAX cube
Measured ElementsC, N, S
Sample Capacityup to 5 g (solid) or 5 mL (liquid)
Carrier Gas OptionsHe or Ar (switchable without hardware modification)
Warranty10 years on combustion furnace and TCD detector
ComplianceASTM D5373, ISO 16968, EN 15148, USP <28>, GLP/GMP-ready
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
ModelUNICUBE
Measured ElementsC, H, N, O, S, Cl
Analysis Time~7–8 min per sample
Detection Limit50 ppm
Sample Mass Range0.1 mg – 1,000 mg
DetectorsThermal Conductivity Detector (TCD), Non-Dispersive Infrared (NDIR) Detector, Electrochemical Detector
Combustion TemperatureUp to 1800 °C (transient, with Sn boat) / 1200 °C (stable furnace zone)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario ISOTOPE cube
Detection PrincipleHigh-Temperature Catalytic Combustion + Gas Chromatographic Separation + Cryogenic Trapping + Isotope Ratio Mass Spectrometry (IRMS) Interface
Sample ThroughputUp to 80 samples unattended
C/N Ratio RangeUp to 8000:1
S/N Ratio RangeUp to 1000:1
H₂ Converter OptionAvailable for CHNS simultaneous analysis
VLS Liquid Autosampler OptionSupported
Chrome HD Hydrogen Isotope KitOptional for δ²H in water with dual-inlet–level precision
Dynamic Mass Range0.1 µg – 50 mg C
Warranty10 years on combustion furnace and TCD cells
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario EL cube
Measured ElementsC, H, O, N, S
Sample Mass Range0.01–500 mg
C/N Ratio Capabilityup to 7000:1
C/S Ratio Capabilityup to 5000:1
Detection PrincipleHigh-Temperature Combustion (1150 °C) + Thermal Conductivity Detection (TCD) for H₂, CO₂, N₂, SO₂, CO
Carrier Gas OptionsHelium or Argon
AutomationIntegrated 80-position autosampler
Furnace & TCD Warranty10 years
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario PYRO cube
ApplicationHigh-Temperature Elemental Analysis Coupled to Isotope Ratio Mass Spectrometry (EA-IRMS)
Sample ThroughputUp to 120 Samples (Integrated Autosampler)
Operating ModesO/H and C/N/S Dual-Mode Configuration
Combustion TemperatureUp to 1800 °C
Detection PrincipleThermal Decomposition / High-Temperature Conversion Followed by Gas Chromatographic Separation and IRMS Detection
ComplianceDesigned for GLP/GMP Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario ISOTOPE select
Detection PrincipleCombustion–TPD–IRMS Coupled Stable Isotope Ratio Analysis (δ¹³C, δ¹⁵N, δ³⁴S, δ¹⁸O)
Sample ThroughputUp to 120 samples unattended
Combustion TemperatureUp to 1,200 °C
Isotope Precision (1σ)≤ 0.1‰ for δ¹³C and δ¹⁵N (n ≥ 10, 0.5–2 mg organic matrix)
Gas SeparationSingle-programmed TPD column for complete baseline-resolved CO₂, N₂, SO₂, CO separation
ComplianceFully compatible with IRMS interfaces (e.g., IsoPrime, Delta V, Nu Instruments)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelrapid OXY cube
Measured ElementOxygen (O)
Detection PrincipleHigh-Temperature Pyrolysis to CO + Thermal Conductivity Detection
Temperature RangeUp to 1450 °C
Accuracy< ±0.1% (relative)
Sample Mass Range1–300 mg
Standard Autosampler120-position integrated
Detector Warranty10 years on thermal conductivity cell
Interference SuppressionPatented column purge technology
ComplianceDesigned for GLP/GMP environments