| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario MACRO cube |
| Measured Elements | C, H, N, S, O |
| Sample Capacity | up to several hundred mg per analysis |
| C/N Ratio Tolerance | up to 7000:1 |
| Detection Limit for S | down to 2 ppm (with optional IR detector) |
| Standard Autosampler | 60-position |
| Detector Options | Thermal Conductivity Detector (TCD), optional Infrared (IR) detector for S, TIC, O, Cl |
| Patented Technology | APT (“Adsorption Purge and Trap”) gas separation system |
| Furnace & TCD Warranty | 10 years |
| Compliance | Designed for ASTM D5373, ISO 19786, ISO 29540, EN 15407, USP <281>, EPA Method 5050 |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario MAX cube |
| Measured Elements | C, N, S |
| Sample Capacity | up to 5 g (solid) or 5 mL (liquid) |
| Carrier Gas Options | He or Ar (switchable without hardware modification) |
| Warranty | 10 years on combustion furnace and TCD detector |
| Compliance | ASTM D5373, ISO 16968, EN 15148, USP <28>, GLP/GMP-ready |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Instrument Type | Dumas Combustion Method |
| Automation Level | Fully Automated Nitrogen Analyzer |
| Measurement Range | 0–500 mg absolute nitrogen or 0–100 % N |
| Repeatability | ±0.05 % absolute (at 250 mg glutamic acid) |
| Sample Mass Capacity | ≤5 g solid or ≤5 mL liquid |
| Recovery Rate | ≥99.5 % |
| Power Supply | 100/110/200/230 V, 50/60 Hz, 1.8 kW |
| Dimensions (W×D×H) | 55 × 55 × 61 cm (including autosampler) |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | UNICUBE |
| Measured Elements | C, H, N, O, S, Cl |
| Analysis Time | ~7–8 min per sample |
| Detection Limit | 50 ppm |
| Sample Mass Range | 0.1 mg – 1,000 mg |
| Detectors | Thermal Conductivity Detector (TCD), Non-Dispersive Infrared (NDIR) Detector, Electrochemical Detector |
| Combustion Temperature | Up to 1800 °C (transient, with Sn boat) / 1200 °C (stable furnace zone) |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario ISOTOPE cube |
| Detection Principle | High-Temperature Catalytic Combustion + Gas Chromatographic Separation + Cryogenic Trapping + Isotope Ratio Mass Spectrometry (IRMS) Interface |
| Sample Throughput | Up to 80 samples unattended |
| C/N Ratio Range | Up to 8000:1 |
| S/N Ratio Range | Up to 1000:1 |
| H₂ Converter Option | Available for CHNS simultaneous analysis |
| VLS Liquid Autosampler Option | Supported |
| Chrome HD Hydrogen Isotope Kit | Optional for δ²H in water with dual-inlet–level precision |
| Dynamic Mass Range | 0.1 µg – 50 mg C |
| Warranty | 10 years on combustion furnace and TCD cells |
| Compliance | Designed for GLP/GMP environments |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | BiovisION Honey |
| Instrument Type | Dedicated Liquid Chromatography–Isotope Ratio Mass Spectrometry (LC-IRMS) System |
| Measurement Precision | δ¹³C ≤ 0.06‰, δ¹⁵N ≤ 0.06‰ |
| Measured Isotopes | ¹³C, ¹⁵N, ¹⁸O, ²H, ³⁴S |
| Mass Range | 1–96 Da |
| Resolution (m/Δm) | 100 |
| Sensitivity (M/I at m/z 44) | <1200 |
| Warranty | 10-year combustion furnace warranty |
| Brand | IsoPrime |
|---|---|
| Origin | United Kingdom |
| Model | isoprime GC5 |
| Detection Sensitivity | low-picomole level |
| Reaction Furnace Temperature | up to 1500 °C |
| Software | IONOS with Peak Mapping |
| Compatibility | Agilent 7890B GC system |
| Solvent Elimination | complete |
| Combustion Efficiency | quantitative (>99.9%) |
| Maintenance Interval | extended due to robust reaction tube design |
| Regulatory Compliance | supports GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | iso CHROM LC Cube |
| Application | Continuous-Flow Liquid Chromatography–Isotope Ratio Mass Spectrometry (LC-IRMS) Interface |
| Principle | High-Temperature Catalytic Combustion (1050 °C) |
| Conversion | Quantitative Oxidation of Organic Carbon → CO₂ |
| Compatibility | Universal HPLC Systems (All Makes & Models) |
| Peak Broadening | <5% Added Bandwidth vs. Direct UV Detection |
| Isotopic Fidelity | No Measurable Isotopic Fractionation (δ¹³C and δ¹⁵N preserved within ±0.2‰, per ASTM D7639-22 validation protocols) |
| Compliance | Designed for GLP/GMP Environments |
| Brand | Elementar |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | isoFLOW |
| Instrument Type | Dedicated Continuous-Flow Sample Introduction System & Interface Components |
| Isotopic Precision | δ¹³C < 0.006‰, δ¹⁵N < 0.006‰ |
| Elemental Coverage | C/H/O/N/S |
| Mass Range | 1–96 Da |
| Resolution | >110 m/Δm (10% valley separation) |
| Sensitivity | <800 (M/I, m/z 44, DI) |
| Brand | Elementar |
|---|---|
| Origin | UK |
| Model | isoprime visION |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Measurement Precision | δ¹³C ≤ 0.06‰, δ¹⁵N ≤ 0.06‰ |
| Measured Isotopes | ¹³C, ¹⁵N, ¹⁸O, ²H, ³⁴S |
| Mass Range | 1–96 Da |
| Resolution | 100 (10% valley) |
| Sensitivity (M/I at m/z 44) | <1200 |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario EL cube |
| Measured Elements | C, H, O, N, S |
| Sample Mass Range | 0.01–500 mg |
| C/N Ratio Capability | up to 7000:1 |
| C/S Ratio Capability | up to 5000:1 |
| Detection Principle | High-Temperature Combustion (1150 °C) + Thermal Conductivity Detection (TCD) for H₂, CO₂, N₂, SO₂, CO |
| Carrier Gas Options | Helium or Argon |
| Automation | Integrated 80-position autosampler |
| Furnace & TCD Warranty | 10 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | trace SN cube |
| Detection Limit (S) | 6 ppb |
| Detection Limit (N) | 15 ppb |
| Sample Types | Liquids, Liquefied Petroleum Gas (LPG), Gases, Solids |
| Analysis Time | 3–5 min per sample |
| Autosampler Capacity | 60 positions |
| Detection Principles | UV Fluorescence (S), Chemiluminescence (N) |
| Compliance | ASTM D5453, D7183, ISO 20846, ISO 20884, EN ISO 17025 |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario PYRO cube |
| Application | High-Temperature Elemental Analysis Coupled to Isotope Ratio Mass Spectrometry (EA-IRMS) |
| Sample Throughput | Up to 120 Samples (Integrated Autosampler) |
| Operating Modes | O/H and C/N/S Dual-Mode Configuration |
| Combustion Temperature | Up to 1800 °C |
| Detection Principle | Thermal Decomposition / High-Temperature Conversion Followed by Gas Chromatographic Separation and IRMS Detection |
| Compliance | Designed for GLP/GMP Environments |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | vario ISOTOPE select |
| Detection Principle | Combustion–TPD–IRMS Coupled Stable Isotope Ratio Analysis (δ¹³C, δ¹⁵N, δ³⁴S, δ¹⁸O) |
| Sample Throughput | Up to 120 samples unattended |
| Combustion Temperature | Up to 1,200 °C |
| Isotope Precision (1σ) | ≤ 0.1‰ for δ¹³C and δ¹⁵N (n ≥ 10, 0.5–2 mg organic matrix) |
| Gas Separation | Single-programmed TPD column for complete baseline-resolved CO₂, N₂, SO₂, CO separation |
| Compliance | Fully compatible with IRMS interfaces (e.g., IsoPrime, Delta V, Nu Instruments) |
| Brand | Elementar |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | precisION |
| Instrument Type | Stable Gas-Phase Isotope Ratio Mass Spectrometer |
| Measurement Precision | δ¹³C ≤ 0.06‰, δ¹⁵N ≤ 0.06‰ (1σ, long-term reproducibility) |
| Measured Isotopes | ¹³C, ¹⁵N, ¹⁸O, ²H, ³⁴S |
| Mass Range | Up to 96 Da |
| Resolution | >110 m/Δm (10% valley definition) |
| Sensitivity | 800 CO₂ molecules per ion (Direct Ionization mode, DI) |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | rapid N exceed |
| Analysis Principle | Dumas Combustion Method |
| Automation Level | Fully Automated |
| Nitrogen Measurement Range | 0–500 mg |
| Sample Mass | 1 g (typical) |
| Repeatability | SD < 0.05% |
| Recovery Rate | ≥99.9% |
| Power Consumption | 1300 W |
| Dimensions (L×W×H) | 420 × 550 × 550 mm |
| Linearity Range | 0–500 mg N |
| Linear Response up to 4× Nominal N Load | Confirmed |
| Compatible Standard Acid Titration Range | Not Applicable (Combustion-based, non-wet-chemistry) |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | rapid OXY cube |
| Measured Element | Oxygen (O) |
| Detection Principle | High-Temperature Pyrolysis to CO + Thermal Conductivity Detection |
| Temperature Range | Up to 1450 °C |
| Accuracy | < ±0.1% (relative) |
| Sample Mass Range | 1–300 mg |
| Standard Autosampler | 120-position integrated |
| Detector Warranty | 10 years on thermal conductivity cell |
| Interference Suppression | Patented column purge technology |
| Compliance | Designed for GLP/GMP environments |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | inductar CS cube |
| Measurement Principle | Infrared Absorption |
| Heating System | High-Frequency Induction Furnace |
| Sample Introduction | Top-loading |
| Detection Method | Dual-stage IR detection with catalytic oxidation |
| Automation Options | Manual loading or 89-position automated sampler |
| Software | Multi-language (including Chinese), LIMS-compatible, GLP/GMP-ready with audit trail capability |
| Compliance | Designed to support ISO 15350, ASTM E1019, and USP <231> for C/S determination in metals and inorganic materials |
| Sample Types | Steel, cast iron, copper, refractory metals, other metals and inorganic materials |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Model | rapid CS cube |
| Measurement Principle | Infrared Absorption |
| Heating System | Resistance Furnace |
| Carbon Range | 0–100% |
| Sulfur Range | 0–100% |
| Sensitivity | 1 ppm |
| Accuracy | ±1 ppm |
| Analysis Time | 5 min |
| Sample Throughput | Standard 60-position Autosampler |
| Optional Autosamplers | 80- or 120-position |
| Chlorine Detection Module | Optional solid-state electrochemical cell |
| TOC/TIC Capability | Yes (via external acidification + optional TIC module) |
| Sample Mass Range | 1 mg – 400 mg |
| Warranty | 10 years on combustion furnace and thermal conductivity detector |
| Brand | Elementar |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | isoprime 100 |
| Instrument Type | Continuous-Flow Stable Isotope Ratio Mass Spectrometer |
| Measurement Precision | ±0.06‰ (1σ) |
| Elemental Coverage | C, H, N, O, S |
| Mass Range | 1–100 Da |