BrandElementar
OriginGermany
Modelsoli TOC cube
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Detection Limit2 ppb C
Repeatability<1.5% RSD
ComplianceDIN 19539 (2022), DIN 15936 (2008)
Sample ThroughputUp to 92 samples unattended
Carbon Quantification Range0.001–100 wt% C
Heating ControlDirect crucible-proximal temperature monitoring with programmable ramp rates and hold times
Gas SwitchingOn-the-fly carrier gas switching during thermal program for selective ROC/TIC separation
Ash RemovalIntegrated automatic ash removal module
Sample FormSolids (soil, sludge, sediment, compost, waste, biomass)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelacquray TOC
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodUV/Persulfate Wet-Chemical Oxidation
Measurement Range0–20,000 ppm C
Detection Limit2 ppb C
Accuracy±1% of reading
Resolution0.01 ppm C
Repeatability<1.5% RSD
ComplianceDesigned for ASTM D5997, ISO 8245, USP <643>, and EPA Method 415.3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modeliso TOC cube
Instrument TypeLaboratory-based TOC/TNb Isotope Ratio Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement RangeC: 5–60,000 ppm
N25–60,000 ppm
Accuracy±2%
Isotopic Precision≤0.1‰ (δ¹³C and δ¹⁵N)
ResolutionHigh Mass Resolution for ¹³C/¹²C and ¹⁵N/¹⁴N ratio determination
Detection CapabilityCoupled to Isoprime IRMS for compound-specific isotopic analysis
Sample IntroductionDirect liquid injection up to 3 mL
AutomationIntegrated 32-position liquid autosampler
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelenviro TOC
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement Range0–100,000 ppm C
Accuracy±3% of reading
Resolution0.001 ppb C
Detection Limit0.005 ppm C
Repeatability≤1% RSD
Sample ThroughputUp to 60 samples unattended
Solid & Liquid Sample CapabilityYes, fully automated without hardware modification
TNb Detection OptionElectrochemical (EC) cell or integrated Chemiluminescence Detector (CLD)
ComplianceDesigned for ASTM D7573, ISO 8245, USP <643>, EN 1484, and EPA Method 415.3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandElementar
OriginGermany
Modelvario TOC cube
Instrument TypeLaboratory TOC Analyzer
Detection PrincipleNon-Dispersive Infrared (NDIR) Absorption
Oxidation MethodHigh-Temperature Catalytic Combustion
Measurement Range0–50,000 ppm C
Detection Limit3 ppb C
Repeatability<1.5% RSD
Sample FormsLiquid and Solid
AutomationIntegrated 50-position Liquid Autosampler
Optional Detection ModesNDIR, Chemiluminescence (CLD), Electrochemical (EC) for TOC or Total Bound Nitrogen (TNb)
Solid TIC ModuleAvailable as add-on unit
ComplianceDesigned for GLP/GMP environments