Environmental Monitoring Instruments
Filter
Showing 571–600 of 2621 results
| Brand | Assemblad |
|---|---|
| Origin | Italy |
| Model | OPA105.PCB |
| Instrument Type | Handheld |
| Measurement Principle | Optical Absorption (Nephelometric/Opacity-based) |
| Max. Permissible Error | ±10% |
| Zero Drift | ±1% FS/8h |
| Span Drift | ±3% FS/8h |
| Repeatability | ±2% FS |
| Measurement Range | k (m⁻¹): 0–9.99 m⁻¹ (0.01 m⁻¹ resolution) |
| Opacity (%) | 0–99.9% (0.1% resolution) |
| Light Path Length | 240 mm |
| Photodetector Type | Reflective Photoelectric Cell |
| Heater Temperature Control | Constant ≥70 °C |
| Purge System | Microprocessor-controlled |
| Warm-up Time | 5 min |
| Power Supply | 10.5–15 V DC (internal rechargeable battery, 7.2 Ah), or 100–240 V AC adapter included |
| Operating Temperature | +5 to +40 °C |
| Dimensions | 290 × 198 × 175 mm |
| Net Weight | 5 kg |
| Communication Interface | RS-232 serial output |
| Compliance | EEC Directive 72/306 (predecessor to EU 2007/46/EC), OIML R99:2008 Class 00 (when integrated with INFRAGAS analyzers) |
| Software Support | PC-based configuration, calibration, and data logging via proprietary Windows application |
| Compatible Interfaces | INFRAGAS 205/305 & 309 gas analyzers, OM00538EST002b/NET protocol |
| Brand | AST / ST |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | DM5200 |
| Instrument Type | Radiation Dose Rate Meter |
| Measurement Range | 0.01–200 µSv/h |
| Energy Response | 0.048–3.00 MeV (≤±20% relative to ¹³⁷Cs) |
| Basic Relative Error | ≤±10% |
| Repeatability | ≤5% RSD per single measurement |
| Accuracy (95% confidence, 15 s integration) | ≤±10% |
| Alarm Thresholds | 0.25, 2.5, 10, 20 µSv/h (user-selectable) |
| Integration Time | 1–60 s (adjustable in 1 s increments) |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | Two 1.5 V D-cell batteries |
| Power Consumption | ≤150 mW |
| Dimensions | 330 × 230 × 90 mm |
| Weight | 1.5 kg |
| Detector | NaI(Tl) scintillation crystal |
| Display | Dot-matrix LCD with Chinese UI |
| Interface | Touch-sensitive keypad |
| Units | µSv/h (default), selectable µR/h |
| Battery Monitoring | Real-time voltage monitoring with low-battery alert |
| Brand | ATAGO |
|---|---|
| Origin | Japan |
| Model | PAL-Soil |
| Measurement Range (w/w) | 0–200% |
| Measurement Range (v/v) | 0–100% |
| Accuracy (w/w) | ±2% (0–40%), ±5% (41–100%) |
| Accuracy (v/v) | ±1% (0–60%), ±2% (61–100%) |
| Temperature Range | 10–40°C (ATC) |
| Resolution | 0.1% |
| Power | 2 × AAA batteries |
| IP Rating | IP65 |
| Dimensions | 5.5 × 3.1 × 10.9 cm |
| Weight | 100 g (instrument only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 100X |
| Instrument Type | Aerosol Testing System |
| Compliance Standards | NIOSH 42 CFR Part 84, GB 2626, EN 13274-7:2019, ASTM F3502-21 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 2i |
| Instrument Type | Aerosol Photometer |
| Price Range | USD $6,800 – $13,600 (est.) |
| Compliance | ISO 14644-3, NSF/ANSI 49, IEST-RP-CC034, EN 12469, CE, UKCA, EN 61010-1:2010, EN 61326-1:2006, FCC Part 15 Subpart B, ISED ICES-003 Issue 7 |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm (10.1 in × 13 in × 6 in) |
| Weight | 8.6 kg (19 lbs) |
| Power Input | 100–250 V AC, 50/60 Hz auto-ranging |
| Flow Rate | 28.3 L/min ±10% (1 ft³/min) |
| Dynamic Range | 0.0001–120 mg/m³ |
| Sensitivity | ±1% of reading (0.01–100% range) |
| Repeatability | ±0.5% of reading (0.01–100% range) |
| Zeroing | Automatic at startup |
| Alarm | User-configurable audible, visual, and haptic |
| Aerosol Compatibility | PAO-4, DOP, DOS/DEHS, Ondina, PEG, Krydol, corn oil, mineral oil, paraffin |
| Data Output | Thermal printer, USB port |
| Data Storage | Up to 150,000 scan records (CSV + PDF) |
| Calibration System | ATI CALIBRA™ 800 aerosol generator with gravimetric traceability and multi-point linearity verification (patent-pending) |
| Software Compliance | 21 CFR Part 11–compliant audit trail, encrypted storage, password protection, electronic signatures (iProbe Plus only) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer | ATI (American Technology Inc.) |
| Type | Imported |
| Model | 4B |
| Price Range | USD $1,200 – $6,500 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 5D |
| Price Range | USD $6,800 – $13,600 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 6D |
| Price Range | USD $6,800 – $13,600 (FOB USA) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | iProbe Plus |
| Instrument Type | Aerosol Detector |
| Compliance | IEC 60068-2-27 (Shock), IEC 60068-2-6 (Vibration), IEC 60068-2-14 (Temperature Cycling), IEC 60068-2-27 (Thermal Shock) |
| Operating Temperature Range | −20 °C to +70 °C |
| Data Storage Capacity | ~150,000 scans |
| Output Formats | CSV, PDF |
| Interface | USB-A port for data export and firmware update |
| Display | 4.3-inch color touchscreen |
| Valve Control | Integrated upstream/downstream/zero valve control via touchscreen |
| Security | Password protection, encrypted data storage, audit-trail compliant with FDA 21 CFR Part 11 |
| Ergonomics | Contoured grip with finger grooves and thumb rest |
| Unique Feature | 10-second “rewind” function (patent pending) |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | TDA-100 |
| Pricing | Upon Request |
| Brand | ATI |
|---|---|
| Origin | USA |
| Model | TDA-2i |
| Dimensions | 25.7 cm × 33 cm × 15.2 cm |
| Weight | 8.6 kg (host 7.5 kg + probe & accessories 1.1 kg) |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Flow Rate | 28.3 L/min ±10% |
| Detection Range | 0.0001% – 100.0% (aerosol penetration) |
| Sensitivity | ±1% of reading (≥0.01% to 100%) |
| Repeatability | ±0.5% of reading (≥0.01% to 100%) |
| Light Source | Solid-state, low-power, low-heat scattering cavity LED (50,000–100,000 hr lifetime) |
| Aerosol Compatibility | PAO-4, DOP, Ondina, PEG, Krydol, Corn Oil, Mineral Oil, Paraffin |
| Alarm | Audible + visual flashing on host and iProbe display |
| Data Output | USB interface (standard), thermal printer (optional) |
| Reporting Modes | Continuous, Summary, Monitoring |
| Compliance | NSF/ANSI 49, IEST-RP-CC001, ISO 14644-3, EN 61010-1:2010, EN 61326-1:2006, CE, FCC |
| Brand | ATI |
|---|---|
| Origin | USA |
| Instrument Type | Ultrasonic Anemometer |
| Measurement Principle | Orthogonal Acoustic Time-of-Flight |
| Axes | 3D (U, V, W) |
| Wind Speed Range | ±65 m/s (model-dependent) |
| Temperature Range | −50 °C to +70 °C (extended to +250 °C) |
| Accuracy | Wind Speed ±0.01 m/s, Orthogonality ±0.1°, Sonic Temperature ±0.05 °C |
| Resolution | Wind Speed 0.001–0.01 m/s (configurable), Wind Direction 0.1°, Temperature 0.01 °C |
| Output | RS-232C/RS-422 serial (ASCII, UART), programmable baud rate (4800–460,800 bps), data rate 1/3600 Hz to 200 Hz |
| Power | 9–32 VDC, <100 mA |
| IP Rating | Fully sealed for outdoor deployment |
| Probe Dimensions (V-model) | 17.8 × 17.8 × 17.8 cm |
| Weight | <1.0 kg |
| Compliance | Designed for GLP-aligned atmospheric research, compatible with eddy covariance systems per ASTM D5116 and ISO 16000-28 |
| Brand | ATOMTEX |
|---|---|
| Model | AT1103M |
| Type | Portable Dose Rate Meter |
| Detector | Be-window NaI(Tl) Scintillator (Ø9×2 mm) |
| Measured Quantity | Ambient Dose Equivalent Rate H′(0.07) |
| Measurement Range | 50 nSv/h – 100 µSv/h |
| Energy Range | 5–160 keV |
| Energy Response | ±35% (5–60 keV), ±30% (60–160 keV) |
| Accuracy | ±15% (full range), ±5% (calibration sources: ⁵⁵Fe, ²⁴¹Am, ¹⁰⁹Cd, ⁵⁷Co) |
| Operating Temperature | 0–+40 °C |
| Relative Humidity | ≤90% at +35 °C |
| IP Rating | IP54 |
| Weight | 0.8 kg |
| Dimensions | 233×85×67 mm |
| Power | Rechargeable Ni-MH battery (6 V), AC 220 V / 50 Hz, DC 12 V |
| Battery Life | ≥24 h |
| Data Storage | 100 measurement records + 256-channel MCA spectrum storage |
| Compliance | IEC 60846, CISPR 22:1997, IEC 61000-4-2:1995, IEC 61000-4-3:1995 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (plastic scintillator with heavy metal admixture) |
| Measuring Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123 variant |
| Energy Range | 15 keV – 10 MeV |
| β Detection | Yes (with optional collimator/filter cap) |
| Display | Backlit LCD |
| Data Storage | 100 measurements |
| Interface | RS-232, 300–19200 baud |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power | Rechargeable 6 V battery / AC 220 V / DC 12 V |
| Compliance | IEC 61000-4-2:1995, IEC 61000-4-3:1995, CISPR 22:1997 |
| Brand | ATOMTEX |
|---|---|
| Origin | Belarus |
| Model | AT1121 |
| Detection Principle | Scintillation (Plastic Scintillator with Heavy Metal Mixture, 30 × 15 mm) |
| Measured Quantity | Ambient Dose Equivalent H*(10) |
| Continuous Dose Rate Range | 50 nSv/h – 10 Sv/h |
| Short-Term Dose Rate Range | 5 µSv/h – 10 Sv/h |
| Pulse Dose Rate Capability | Down to 10 ns (for AT1123/AT1123A variants only) |
| Energy Range | 15 keV – 10 MeV |
| β Detection Capability | Yes |
| Operating Temperature | −30 °C to +40 °C |
| IP Rating | IP54 |
| Weight | 0.9 kg |
| Dimensions | 233 × 85 × 67 mm |
| Power Supply | Rechargeable 6 V battery (≥12 h), AC 220 V, or DC 12 V |
| Data Interface | RS-232, 300–19200 baud |
| Memory Capacity | 100 measurement records |
| Display | Backlit LCD |
| Alarm | Audible and visual threshold alerts |
| Brand | Atomtex |
|---|---|
| Model | AT1320 |
| Detector Type | Scintillation-based Gamma Spectrometer |
| Detector Crystal | NaI(Tl), Ø63×63 mm |
| Activity Range (¹³⁷Cs) | 3.7–1,000,000 Bq/kg (or Bq/L) |
| Activity Range (⁴⁰K) | 50–20,000 Bq/kg |
| Activity Range (²²⁶Ra & ²³²Th) | 10–10,000 Bq/kg |
| Energy Range | 50–3000 keV |
| Energy Resolution (¹³⁷Cs, 662 keV) | 7.0–8.5 % FWHM |
| Intrinsic Nonlinearity | ≤1 % |
| Relative Uncertainty in Specific Activity Measurement | ≤±20 % |
| Minimum Detectable Activity (¹³⁷Cs in 1 L Marinelli beaker, 3 h, P=0.95) | 3.0 Bq/L |
| Sample Density Range | 0.1–3.0 g/cm³ |
| Operating Temperature | 0–40 °C |
| Power Supply | 220 V ±10 %, 50 Hz ±2 Hz |
| Power Consumption | ≤8 VA |
| Continuous Operation Time | ≤24 h |
| 24-h Drift | ≤3 % |
| Dimensions (Detector) | 97×405 mm, 3.0 kg |
| Dimensions (Processing Unit) | 200×109×35 mm, 0.62 kg |
| Shielding Assembly | Ø600×700 mm, 110 kg |
| AC Adapter | 92×62×52 mm, 0.8 kg |
| EMC Compliance | IEC/EN 61000-4-2:1995, IEC/EN 61000-4-3:1995, IEC/EN 61000-4-4:1995, IEC/EN 61000-4-11:1994, CISPR 22:1997 |
| Brand | Atomtex |
|---|---|
| Model | AT2140 / AT2140A |
| Type | Personal Dose Rate & Dose Meter (γ-ray) |
| Dose Rate Range (AT2140) | 0.01 μSv/h – 10 mSv/h |
| Dose Rate Range (AT2140A) | 0.01 μSv/h – 100 mSv/h |
| Dose Range | 0.01 μSv – 9.99 Sv |
| Dose Measurement Range | 0.1 μSv – 1.99 Sv |
| Relative Measurement Error | ±15% max. |
| Calibration Accuracy | ±5% max. |
| Sensitivity to ¹³⁷Cs | 1.8 cps/(μSv·h⁻¹) |
| Energy Response Range | 50 keV – 3 MeV |
| Energy Dependence (vs. 662 keV ¹³⁷Cs) | ±30% (AT2140), ±25% (AT2140A) |
| Angular Dependence (±60°, ¹³⁷Cs/⁶⁰Co) | ±25% |
| (²⁴¹Am) | ±60% |
| Response Time (Dose Rate >1 � | Sv/h): ≤10 s (AT2140), ≤5 s (AT2140A) |
| Operating Temperature | −20°C to +50°C (AT2140), −30°C to +60°C (AT2140A) |
| Relative Humidity (non-condensing) | ≤95% at 35°C |
| IP Rating | IP40 |
| Drop Resistance | 1.0 m onto hard surface |
| Power Supply | 2 × AA batteries |
| Battery Life | 5,000 h (AT2140), 10,000 h (AT2140A) |
| Dimensions & Weight | 111 × 70 × 28 mm, 0.11 kg |
| Brand | ATOMTEX |
|---|---|
| Origin | Imported (Non-China) |
| Manufacturer Type | Authorized Distributor |
| Model | AT2503 |
| Measurement Range (Hp(10)) | 1 µSv – 10 Sv |
| Dose Rate Range (Hp(10)) | 0.1 µSv/h – 0.5 Sv/h |
| Energy Response | 50 keV – 1.5 MeV |
| Dose Accuracy (¹³⁷Cs) | ±5% |
| Dose Rate Accuracy | ±25% (0.1–1 µSv/h), ±15% (>1 µSv/h) |
| Energy Dependence | ±30% |
| Alarm Thresholds | 8 programmable independent levels |
| Detector Type | Energy-compensated GM tube with built-in background tracking |
| Communication | IR interface to reader, RS-232 to PC |
| Calibration | Traceable to water-equivalent phantom (30 × 30 × 15 cm) |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AUF Universal Gas Filter |
| Pricing | Upon Request |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Model | C16531-050GD / C16531-100GD |
| Spectral Range | 400–1000 nm |
| Peak Wavelength | 630 nm |
| Chip Temperature | −20 °C |
| Photon Detection Efficiency (PDE) | 55–65 % |
| Dark Count Rate | 20–450 cps |
| Afterpulsing Probability (100–500 ns) | ≤0.1 % |
| Comparator Output | TTL-compatible |
| Max Count Rate | 20 MHz (C16531-050GD), 7 MHz (C16531-100GD) |
| Active Area | 50 µm or φ100 µm |
| Supply Voltage | ±5 V DC |
| Brand | Auniontech |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Topaz5D |
| Resolution | 1920 × 1080 |
| Pixel Size | 2.5 µm |
| Package | Chip-Scale Package (CSP) |
| Power Consumption | <200 mW |
| Output | Simultaneous 2D + RAW 3D data streams |
| Illumination Requirement | Ambient indoor/outdoor lighting only |
| Depth Range | 4 cm to >150 cm |
| Frame Rate | Up to 30 fps (with OpenCL/CUDA-compatible processing unit) |
| SDK | Topaz5D 5D Processing SDK |
| Compliance | RoHS-compliant packaging, CE-marked evaluation hardware |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-5 |
| Detection Principle | Ionization Chamber / GM Tube (Internal) + External Probe Compatibility |
| Energy Range | 45 keV – 3 MeV (γ/X-rays) |
| Dose Rate Range (Digital) | 0.1 µSv/h – 999 mSv/h |
| Dose Rate Range (Analog) | 1 µSv/h – 1000 mSv/h |
| Power Supply | IEC 6LR61 9 V battery |
| Certification | PTB-certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Interface | RS232 serial port |
| Max. External Cable Length | 100 m (probe-dependent) |
| Alarm Functions | Programmable dose & dose rate thresholds |
| Data Storage | Non-volatile memory for accumulated dose |
| Auto-probe Recognition | Yes (e.g., “ext 17” display upon connection) |
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-5 |
| Detection Principle | GM tube-based photon (γ/X-ray) dosimetry |
| Energy Range | 45 keV – 3 MeV |
| Dose Rate Range (analog) | 1 µSv/h – 1000 mSv/h |
| Dose Rate Range (digital) | 0.1 µSv/h – 999 mSv/h |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | PTB-certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Interface | RS232 serial port |
| External Probe Support | Yes (up to 100 m cable length) |
| Auto-probe Recognition | Yes |
| Memory | Non-volatile dose storage |
| Alarm Functions | Programmable dose & dose rate thresholds |
| Display | Analog needle + digital LCD with real-time avg/max/accumulated values |
| Brand | AUTOMESS |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Alarm Functions | Adjustable Dose & Dose Rate Thresholds |
| Interface | RS232 Serial Port |
| External Probe Support | Up to 100 m cable length (model-dependent) |
| Certification | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Power Supply | IEC 6LR61 9 V battery |
| Compliance | Designed for IEC 60846, IEC 61017, and ISO 4037-3 referenced radiation protection applications |
| Brand | Automess |
|---|---|
| Origin | Germany |
| Model | 6150AD-6 |
| Type | Portable Dose Rate Meter |
| Measurement Principle | Ionization Chamber / GM Tube Based Photon Detection (γ/X-ray) |
| Energy Range | 60 keV – 1.3 MeV |
| Dose Rate Range (Digital) | 0.01 µSv/h – 9.99 mSv/h |
| Dose Rate Range (Analog) | 0.1 µSv/h – 10 mSv/h |
| Power Supply | IEC 6LR61 (9 V) Battery |
| Interface | RS232 Serial Port |
| External Probe Cable Length Options | 1.25 m, 3 m, 10 m, 20 m, 75 m, 100 m |
| Compliance | PTB Certified (Physikalisch-Technische Bundesanstalt, Germany) |
| Brand | Avisoft |
|---|---|
| Origin | Germany |
| Model | CM16/CMPA |
| Instrument Type | Ultrasonic Noise Recorder |
| Frequency Range | 2 kHz to 200 kHz |
| Self-Noise | 18 dB SPL |
| Sensitivity | 500 mV/Pa |
| Connector | XLR-5 Male |
| Dimensions | 36 × 36 × 60 mm |
| Weight | 65 g |
| Power Supply | External Polarization via UltraSoundGate Interface |
| Optional Field Accessory | USB Power Adapter |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AVVOR 8000, AVVOR 9000, HM1000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (Portable) & AVVOR 9000 (Online) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Measurable Elements (8000) | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Pd, Sn |
| Measurable Elements (9000) | Cu, Pb, Zn, Cd, Mn, Sb, Sb³⁺, Tl, Fe, Ni, As, Hg, Se, Cr, Cr⁶⁺, Co, Mo, Au, Ag, Pd, U |
| Detection Limit | Sub-ppb (ng/L) range for most metals |
| Output Interfaces | Dual 4–20 mA analog outputs (9000), RS-232/RS-485, optional wireless telemetry |
| Software | PC-based control & data logging with audit trail, GLP-compliant reporting |
| Enclosure Rating | IP67 (8000), NEMA 4X / IP66 (9000) |
| Power | Rechargeable Li-ion battery (8000) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 (HM-1, HM-2, HM-3) and AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurement Range | Sub-ppb to ppm |
| Electrode Options | Gold, Mercury-film, Bismuth-film, and Bare Carbon Working Electrodes |
| Output Interfaces | Dual 4–20 mA analog outputs, RS-232, RS-485 |
| Compliance | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, and EPA Method 7000B |
| Software | Onboard data logging with timestamped audit trail, GLP-compliant reporting |
| Enclosure Rating | IP65 (AVVOR 8000 series), IP67 (AVVOR 9000 outdoor cabinet) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Instrument Type | Portable (8000) & Online Continuous Analyzer (9000) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Cd, Pb, Zn, Ni, As, Hg, Cr (total & Cr⁶⁺), Fe, Mn, Sb, Tl, Se, Co, Mo, Ag, Au, Pd, Sn, U |
| Measurement Time | ≤30 min per sample (8000) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppt (ng/L) for key elements |
| Compliance | US EPA Methods 7063, 7472, 1001 |
