Environmental Monitoring Instruments
Filter
Showing 691–720 of 2621 results
| Brand | Azure Cloud & Wind Confluence |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | YL-CQC10 |
| Instrument Type | Online Water Quality Analyzer |
| Measurement Parameters | Velocity, Depth, Flow Rate, Temperature |
| Flow Range | 0.01–6.50 m/s |
| Velocity Accuracy | ±1.0% ± 1.2 cm/s |
| Velocity Resolution | 0.75 mm |
| Water Temperature Range | Not specified (standard ambient range) |
| Temperature Accuracy | ±0.8 °C |
| Water Level Range | 0–10 m |
| Level Accuracy | ±0.2% ± 0.2 cm |
| Flow Rate Range | 1 L/s – 99,999,999 m³/h |
| Power Supply | Internal Li-ion battery |
| Communication | RS485, Modbus RTU protocol |
| Data Storage | 100,000 records |
| Measurement Modes | Manual & automatic (interval configurable from 0 to 120 min in 5-min increments) |
| velocity averaging duration | 10–120 s (auto), 60/100 s (manual) |
| Physical Configuration | Portable host unit with submersible sensor, telescoping pole (2 m standard, customizable extension) |
| Display | Backlit LCD |
| Key | Brand: Baineng |
|---|---|
| Model | N-SPC-25W |
| Rated Power | 25 W |
| Nominal Voltage | 18 V (for 12 V battery systems) |
| Peak Voltage (Vmp) | 17.9 V |
| Peak Current (Imp) | 1.4 A |
| Open-Circuit Voltage (Voc) | 22.41 V |
| Short-Circuit Current (Isc) | 1.54 A |
| Dimensions | 350 × 540 × 16 mm |
| Weight | 2 kg |
| Cell Type | Monocrystalline Silicon |
| Encapsulation | Tempered Glass + Aluminum Frame, IP65-rated waterproof lamination |
| Output Connector | DC 5.5×2.1 mm male plug |
| Cable Length | 2 m |
| Junction Box | Standard non-diode, lead-wire-free design |
| STC Conditions | 1000 W/m², AM1.5, 25 °C |
| Brand | Baoying |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | C800 |
| Price Range | USD 14,000 – 57,000 |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Baseline 9000 |
| Detection Principle | Flame Ionization Detection (FID) |
| Instrument Type | Benchtop Laboratory Analyzer |
| Configuration | Multi-Component VOC Analyzer |
| Detection Limit | <0.1 ppm (as propane) |
| Measuring Range | 10 ppm–10% (propane) or 10 ppm–50% (methane), factory-configurable per application |
| Operating Sample Temperature | Up to 191°C (376°F) |
| Sample Filtration Requirement | Pre-filtered, non-condensing, particle size <10 µm |
| Display | Graphical LCD with real-time parameter visualization |
| Communication Interfaces | RS-232/RS-485 serial, Ethernet, analog (4–20 mA / 0–10 V), digital I/O, relay outputs |
| Calibration | User-scheduled automatic zero/span calibration |
| Flow Control | Electronic FlowGuard™ system with integrated fuel/air/sample flow regulation, electronic back-pressure regulator, and sample bypass |
| Ignition | Automatic FID ignition sequence |
| Software | 9000 Keeper PC Utility for method storage, configuration upload/download, and firmware management |
| Mounting Options | Benchtop or 19-inch rack-mountable |
| Compliance | Designed for use in environments requiring EPA Method 25A, ASTM D6348, ISO 11843-2, and USP <467> compliant VOC monitoring workflows |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Baseline 9200 |
| Pricing | Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE piD-TECH eVx |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | eV-NXT 045-110 |
| Price | Upon Request |
| Detection Range | 0–10,000 ppm |
| LOD | 500 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 0.6 mV/ppm |
| Calibration Gas | 2000 ppm Isobutylene (standard) |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 3.3 V DC nominal |
| Power Consumption | < 80 mW (active mode) |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | eV-NXT 045-111 |
| Detection Range | 0–2,000 ppm |
| LOD | 100 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 2.4 mV/ppm |
| Measurement Condition | 100 ppm |
| Operating Voltage | Low-Voltage DC |
| Power Consumption | Ultra-Low |
| Intrinsic Safety Rating | Certified |
| Onboard Fault Detection | Yes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-112 |
| Detection Range | 0–200 ppm |
| LOD | 10 ppb |
| T90 | < 3.5 s |
| Typical Sensitivity | 12 mV/ppm |
| Operating Condition | 100 ppm |
| Power Requirements | Low-voltage, low-power design |
| Compliance | Intrinsically Safe (IS) certified |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-113 |
| Detection Range | 0–20 ppm |
| LOD | 1.0 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 118 mV/ppm |
| Measurement Condition | 10 ppm |
| Operating Voltage | Low-Voltage DC |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-114 |
| Detection Range | 4 ppm |
| LOD | 0.5 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 545 mV/ppm |
| Measurement Condition | 1 ppm |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE PID-TECH eV-NXT |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-010 |
| Pricing | Available Upon Request |
| Certification | UL, CAN/CSA C22.2 No. 60079-0, ATEX II 2G Ex d [ia] IIC T4 Ga, IECEx Ex d [ia] IIC T4 Ga |
| Detection Range | 0–10,000 ppm isobutylene equivalent |
| Minimum Detectable Quantity (MDQ) | 500 ppb (isobutylene) |
| T90 Response Time | < 2 s (typical) |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Output Signal | 0–5 V DC analog |
| Power Supply | 5.0 V ±0.1 V DC |
| Ingress Protection | IP67-rated housing |
| Filter Configuration | Dual-stage particulate & hydrophobic membrane filter |
| Temperature Drift | < 0.05% FS/°C |
| Humidity Compensation | Electrode-based active suppression |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-011 |
| Price | Upon Request |
| Detection Range | 2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 100 ppb |
| T90 Response Time | < 2 s (typical) |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Design | Intrinsically Safe, 4-Series Compatible Form Factor |
| Lamp Lifetime | Extended Operational Life |
| Temperature Sensitivity | Negligible |
| Humidity Compensation | Electrode-Based Suppression |
| Filtering | Dual-Stage Particle Protection |
| Signal Stability | Internal Linear Regulator Circuitry |
| Maintenance | Field-Serviceable, Cleanable Electrodes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-014 |
| Pricing | Available Upon Request |
| Detection Range | 2 ppm |
| Minimum Detectable Quantity (MDQ) | 0.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Certification | UL, CAN/CSA C/US, ATEX II 1G, IECEx Ex ia IIC T4 Ga |
| Sensor Architecture | 4-Series Compatible Form Factor |
| Lamp Life | > 12,000 hours |
| Operating Temperature Range | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based suppression |
| Filtering | Dual-stage particulate protection |
| Power Supply | Internal linear regulation for signal stability |
| Maintenance | Field-serviceable, cleanable electrode assembly |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ |
| Detection Range | 0–2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 10 ppb |
| T90 Response Time | < 2 s (typical) |
| Certifications | UL, CAN/CSA C22.2 No. 152, ATEX II 2G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga |
| Intrinsic Safety Design | Yes |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based humidity suppression |
| Dual-Stage Particle Filtration | Integrated |
| Signal Stability | Internal linear voltage regulation |
| Structural Compatibility | 4-Series electrochemical sensor footprint |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | A-ToxII |
| Instrument Type | Online |
| Test Organism | Algae (Chlorella vulgaris, ISO 8692:2012 compliant) |
| Operating Temperature | 0–35 °C |
| Reagent Storage Temperature | 0–30 °C |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | BBE Moldaenke GmbH |
| Type | Imported Instrument |
| Model | Algae Torch Online |
| Application | Real-time in-situ chlorophyll a and phycocyanin quantification in natural and engineered water systems |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Algae Torch |
| Measurement Parameters | Total Chlorophyll a (0–500 µg/L), Cyanobacterial Density, Turbidity (0–200 NTU), GPS Coordinates |
| Detection Time | <20 s |
| Resolution | 0.1 µg/L (Chl-a) |
| LOD | 0.15 µg/L |
| Excitation Wavelengths | 470 nm, 526 nm, 610 nm |
| Weight | 1.3 kg |
| Dimensions (H × Ø) | 500 mm × 60 mm × 68 mm |
| Power Supply | Internal Rechargeable Battery (AC Adapter: 110/240 V, 50/60 Hz) |
| Operating Temperature | 0–35 °C |
| Storage Temperature | 0–50 °C |
| IP Rating | IP68 |
| Depth Rating | 10 m (standard), 100 m (optional version) |
| Data Storage | 2000 measurements |
| Interface | USB |
| Software | bbe++ for Windows |
| Accessories | 10-m rope, telescopic pole, nylon backpack, underwater data cable extensions (10–30 m), sensor performance kits |
| Brand | BBE Moldaenke |
|---|---|
| Model | AlgaeTorch |
| Measurement Principle | In-situ algal pigment fluorescence detection (excitation at 470 nm, 525 nm, 610 nm) |
| Parameters | Total chlorophyll a / total algal density / cyanobacteria concentration |
| Range | 0–500 µg Chl-a/L |
| Response time | <20 s |
| Resolution | 0.1 ng Chl-a/L |
| Accuracy | ±0.015 ng Chl-a/L (total algae) |
| LOD | 0.1 µg Chl-a/L (single-species cyanobacteria) |
| Turbidity compensation | 0–200 FTU |
| Operating temperature | 0–35 °C |
| Depth rating | AlgaeTorch 10 (10 m), AlgaeTorch 100 (100 m) |
| Protection class | IP68 |
| Dimensions | 500 × 60 mm (H × Ø) |
| Weight | 1.3 kg |
| Power supply | 12 V DC (internal rechargeable battery) |
| Data interface | USB |
| Memory capacity | 2000 measurements |
| Software | bbe++ for Windows |
| Optional accessories | telescopic pole, shoulder strap, 10 m tether cable, probe performance kit |
| GPS module | integrated |
| Data output formats | ASCII, Excel (.xlsx), plain text |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | AOA |
| Application | Real-time online chlorophyll a and phytoplankton group quantification |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | BG00750001 |
| Instrument Type | Online Volatile Phenol Analyzer |
| Output Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, Ethernet (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Analyzer |
| Model | BG00750002 |
| Communication Options | 4–20 mA output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Automation Features | Fully automated analysis cycle, programmable measurement interval, auto-cleaning, auto-calibration (manual calibration supported), power-loss recovery with automatic restart |
| Brand | BBE/bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | BG00750003 |
| Instrument Type | Benchtop |
| Analyte | Chloride Ion |
| Measurement Range | 0.1 mg/L |
| Limit of Detection (LOD) | 0.8 mg/L |
| Response Time | 10 min |
| Measurement Accuracy | ≤2% |
| Operating Temperature Range | 0–45 °C |
| Communication Interfaces | 4–20 mA, RS232/RS485, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic (China-Made) |
| Model | bbe Cn-PWR II |
| Instrument Type | Online Analyzer |
| Communication Options | 4–20 mA analog output, RS232/RS485 serial interface, MODBUS RTU/TCP, TCP/IP (optional) |
| Brand | BBE / bbe Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Digestion Method (Online) |
| Wavelength | 600 nm (standard for Cr(VI)/Cr(III) absorbance ratio) |
| Measurement Range | 10–500 mg/L, 10–1000 mg/L, or 10–1500 mg/L (user-selectable range switching) |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ ±5% RSD |
| Limit of Detection (LOD) | 10 mg/L COD |
| Cycle Time | 30 minutes per analysis |
| Sample Volume per Cycle | 1.5–3 L |
| Compliance | Designed to meet ISO 6060 and EPA Method 410.4 requirements for online COD monitoring |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | Colifast ALARM |
| Pricing | Upon Request |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Colifast CALM |
| Pricing | Available Upon Request |
| Brand | BBE Moldaenke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Colifast Field Kit |
| Pricing | Available Upon Request |