| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ZWIN-CHL1006 |
| Application | Online Chlorophyll-a Monitoring |
| Measurement Principle | Chlorophyll Fluorescence Detection |
| Chlorophyll-a Range | 0–500 µg/L |
| Limit of Detection (LOD) | 0.01 µg/L |
| Accuracy | <5% FS |
| Resolution | 0.01 µg/L |
| Response Time | <15 s |
| Operating Temperature | 0–50 °C |
| Dimensions (Ø × L) | 34 × 225 mm |
| Housing Materials | POM + Titanium Alloy + 316L Stainless Steel |
| Ingress Protection | IP68 (1 bar) |
| Power Supply | 12–24 VDC |
| Output Interface | RS485 with Modbus RTU Protocol |
| Self-Cleaning Function | Yes |
| Light Source | High-Brightness LED |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | ZWIN-VOCS |
| Price Range | USD 1,400 – 7,000 |
| Detection Principle | Photoionization Detection (PID) |
| Instrument Type | Continuous Online Analyzer |
| Typical Configuration | Total VOC (TVOC) Monitor |
| Measurement Range | 0–1000 ppm |
| Resolution | 0.01 ppm |
| Accuracy | ≤ ±5% FS |
| Response Time | T90 < 5 s |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZWIN-YC06-PLAT |
| Price Range | USD 1,400 – 7,200 (FOB) |
| Measured Pollutants | CO, CO₂, NO₂, PM₂.₅, PM₁₀ |
| Measurement Principle | Optical Scattering (PM), Electrochemical (Gases), Piezoelectric (Noise), Ultrasonic/Cup Anemometry (Wind), Capacitive (RH), Thermistor/RTD (Temp), Piezoresistive (Baro) |
| Display | 7-inch capacitive touchscreen |
| Data Transmission | 3G/4G LTE, RS485, Ethernet |
| Environmental Rating | IP65 enclosure, IP67 sensors |
| Power Options | AC220V ±10% or solar-battery hybrid (optional) |
| Compliance | GB 3095–2012, HJ 653–2013, HJ 93–2013, ISO 12103-1 (dust calibration reference), ASTM D1319 (for hydrocarbon interference mitigation in CO/NO₂ sensing) |
| Brand | ZWINSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZWIN-YCB06 |
| Instrument Type | Portable |
| Measurement Principle | Beta-Ray Absorption |
| Measured Parameter | PM10 |
| Measurement Range | (0–1000) µg/m³ or (0–10000) µg/m³ (selectable) |
| Sampling Flow Rate | 16.7 L/min |
| Minimum Detection Limit | ≤2 µg/cm² |
| Filter Spot Area | 1.68 cm² |
| Spot Center-to-Center Spacing | ~18.84 mm ± 0.5 mm |
| Full-Scale Loading | 1.5 mg/cm² |
| Resolution | ±2% |
| Max. Permissible Error | ≤±20% |
| Sampling Tube Material | Stainless Steel (Note: “Drill alloy” in source is nonstandard |
| Sampling Tube Length | 500 cm |
| Operating Temperature | 0–300 °C |
| Relative Humidity | ≤80% RH |
| Flue Gas Pressure Range | −10 to +10 kPa |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Detector | Scintillation Detector with Photomultiplier Tube |
| Data Update Interval | 5 s |
| Data Storage | Onboard non-volatile memory |
| Repeatability | ≤±2% |
| Flow Accuracy | ±2% (at nominal 16.7 L/min) |
| Timing Drift | <10 s per 24 h |
| Acoustic Noise | ≤65 dB(A) |
| System Leak Rate | <200 Pa pressure decay within 1 min after sealing at −5 kPa vacuum |
| Ambient Operating Conditions | Indoor/outdoor portable deployment |
| Brand | ZWINsoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ZWINsoft1.0 |
| Pricing | Upon Request |
| Brand | ZWINSOFT |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Z WIN-AQMS-PLAT |
| Pollutant Parameters | SO₂, NO₂, CO, O₃, PM₂.₅, PM₁₀ |
| Compliance Framework | Designed for integration with China’s National Environmental Monitoring Network (CNEMN), aligned with HJ 653–2013, HJ 654–2013, and GB 3095–2012 standards |
| Brand | ZwinSoft |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ZWIN-1.0 |
| Price Range | USD 7,000 – 14,000 (FOB) |
| Measurement Principle | Integrated Sensor Network Data Aggregation & GIS-Based Spatial Analytics |
| Measured Parameters | PM₂.₅, PM₁₀, TSP, VOCs, NO₂, SO₂, NH₃, wind speed/direction, humidity, temperature (configurable per deployment) |
| Measurement Range | 0–1,000 µg/m³ (PM), 0–50 ppm (gases) |
| Sampling Interval | 1 minute (configurable) |
| Sampling Flow Rate | 1.0 L/min ±5% |
| LOD (PM) | 1 µg/m³ |
| Flow Stability | ±2% over 24 h |
| Origin | Beijing |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZY-10 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Other Flue Gas Analyzer |
| Indication Error | ≤ Class 0.5 |
| Repeatability | ≤ 2% |
| Response Time | ≤ 60 s |
| Stability | ≤ 5% |
| Magnification | 10× |
| Objective Aperture | 50 mm |
| Ringelmann Scale Range | 0–5 (inclusive) |
| Visual Observation Accuracy | ≤ Class 0.5 |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZY-80 |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Visual Smoke Opacity Analyzer |
| Accuracy Class | ≤0.5 |
| Repeatability | ≤2% |
| Response Time | ≤60 s |
| Stability | ≤5% |
| Magnification | 15× |
| Observation Distance | 10–2000 m |
| Objective Aperture | 80 mm |
| Lingerman Scale Range | 0–5 |
| Reticle Imaging Magnification | 2× |
| Dimensions | 605 × 110 × 110 mm |
| Includes | Tripod Mount |
| Optional Accessory | Universal DSLR/Digital Camera Adapter Bracket |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZYET-5100 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | ≤ ±5% FS |
| Repeatability | ≤ 2% RSD |
| Response Time | ≤ 90 s (T₉₀) |
| Stability | ≤ ±5% FS/8 h |
| Measurement Principles | Electrochemical (O₂, NO, NO₂, SO₂, CO) |
| O₂ Range | 0–20.9 vol% |
| NO | 0–1000 ppm |
| NO₂ | 0–100 ppm |
| SO₂ | 0–2000 ppm |
| CO | 0–2000 ppm |
| Ambient Temp | 0–200 °C |
| Flue Gas Temp | 0–400 °C |
| Static Pressure | −30 to +30 kPa |
| Differential Pressure | 0–2.5 kPa |
| Resolution | O₂: 0.1 vol% |
| Gases | 1 ppm |
| Temp | 1 °C |
| Pressure | 0.01 kPa (Static), 1 Pa (Differential) |
| Accuracy | O₂: ±0.5% FS |
| Gases | ±5% FS |
| Temp | ±1% (Ambient), ±2% (Flue) |
| Pressure | ±3% FS |
| Data Storage | 500 measurement sets |
| Power | Internal 6 V × 2 rechargeable battery |
| Dimensions (W×D×H) | 417 × 234 × 318 mm |
| Weight | ~10 kg (configuration-dependent) |
| Operating Environment | −0°C to +40°C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZYET-5101 |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Portable Flue Gas & Particulate Analyzer |
| Indication Error | ≤5% FS |
| Repeatability | ≤2% RSD |
| Response Time | ≤90 s |
| Stability | ≤5% drift over 2 hours |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYJY-DZ02 |
| Instrument Category | Soil Moisture / Matric Potential Analyzer |
| Rainfall Intensity Range | 20–200 mm/h |
| Rainfall Uniformity Coefficient | >0.85 |
| Rainfall Regulation Accuracy | ±6 mm/h |
| Response Time for Intensity Adjustment | <30 s |
| Rain Gauge Orifice Diameter | Φ200 ± 0.6 mm |
| Rain Gauge Resolution | 0.1 mm |
| Controller Supply Voltage | AC 220 V, 50 Hz |
| Operating Temperature | 0–60 °C |
| Operating Relative Humidity | ≤95% RH |
| Data Logger Storage Capacity | Unlimited (SD card or internal flash) |
| Sampling Interval | ≥3 s (configurable) |
| Nozzle Types | Three interchangeable nozzles (9 mm, 11 mm, 13 mm diameter) |
| Spray Angle | 45° |
| Redundant Hydraulic Architecture | Yes |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYJY-DZ10 |
| Instrument Type | Soil Moisture & Infiltration Simulation System |
| Rainfall Area | 2–100 m² (customizable) |
| Rainfall Height | 3–4 m (customizable) |
| Rainfall Intensity Range | 20–200 mm/h |
| Rainfall Uniformity Coefficient | >85% |
| Intensity Resolution | ±6 mm/h |
| Rainfall Duration | Programmable (unlimited) |
| Control Mode | PC-based real-time monitoring with pressure, valve status, and intensity feedback |
| Power Supply | 220 V AC |
| Structural Design | Tool-free quick-connect modular assembly |
| Service Life | ≥15 years |
| Data Storage Capacity | 1000 hours of rainfall intensity logs |
| Brand | Zykx |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | InLab-2300 |
| Instrument Type | Portable |
| Measurement Principle | Infrared Spectrophotometry (Dual-Wavelength & Full-Spectrum Scan) |
| Measurement Range | 0.00–100 mg/L (water sample, standard 4 cm quartz cuvette) |
| Detection Limit | <0.12 mg/L (CCl₄ extract) |
| <0.003 mg/L (water sample, 40 | 1 extraction ratio, 4 cm cuvette) |
| Accuracy | ±0.4 mg/L (C < 10 mg/L) |
| Repeatability | ≤1% (for 20 & 40 mg/L oil standards) |
| Resolution | 0.001 mg/L |
| Measurement Frequency | 5 samples/min |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Baseline Drift | <0.001 AU/60 min |
| Absorbance Range | 0.0000–3.000 AU |
| Linear Correlation Coefficient | R > 0.999 |
| Power Supply | 220 V ±22 V, 50 Hz ±1 Hz, 40 VA |
| Dimensions | 470 × 380 × 210 mm |
| Weight | ~12 kg |
| Operating Environment | 5–35 °C, 20–90% RH |
| Battery Life | ~8 h (integrated Li-ion) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX |
| Application | Field-based soil erosion simulation, rainfall-runoff-sediment process monitoring, slope hydrology research |
| Rainfall Area | 8–50 m² (customizable) |
| Rainfall Height | ≤3.2 m |
| Rainfall Intensity Range | 15–150 mm/h |
| Raindrop Diameter | 0.5–6 mm (7 selectable classes, 3 pre-configured) |
| Rainfall Uniformity Coefficient | ≥0.85 |
| Rainfall Measurement Accuracy | ±0.01 mm/h |
| Rainfall Regulation Resolution | 5 mm/h |
| Sediment Concentration Range | 1–400 kg/m³ (±5% error <100 kg/m³ |
| Runoff Flow Rate Range | 3–2400 mL/s (±3% error) |
| Sampling Interval | 20–300 s |
| Slope Adjustment Range | 0–30° |
| Portable Steel Flume Dimensions | Adjustable from 2×4 m to 3×5 m |
| Vehicle Platform | Great Wall Fengjun 5 pickup truck |
| Power Supply | Onboard generator + optional solar/battery backup |
| Data Transmission | Wireless telemetry (optional) |
| Compliance | Designed for ASTM D422, ISO 11277, USLE/RUSLE framework implementation, GLP-aligned data logging architecture |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | PCD-2015 |
| Pricing | Upon Request |
| Display | 4.3" Color Touchscreen (Chinese UI) |
| Power | Rechargeable Li-ion Battery (24 h continuous operation) |
| Dimensions | 260 × 155 × 50 mm |
| Weight | 1.3 kg |
| Connectivity | USB 2.0, Bluetooth 4.2 (optional) |
| Data Storage | Internal memory for ≥10,000 measurement records |
| Enclosure | Anodized aluminum alloy, IP67-rated |
| Printer Support | Optional thermal printer module |
| Compliance | Meets technical requirements of HJ/T 96–2003, HJ/T 99–2003, and HJ 506–2009 (China EPA) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | PTB-200M |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) + Colorimetry |
| Target Elements | Cu, Cd, Pb, Zn, As, Hg, Mn, Sb, Ni (expandable) |
| Detection Time | ≤5 min per sample |
| Accuracy | RSD ≤2% (at Cd 50 µg/L) |
| Resolution | 1 ppb |
| Detection Limits | ≤0.5 µg/L (ASV mode) |
| Measurement Range (ASV) | 0.1 µg/L – tens of mg/L |
| Measurement Range (Colorimetry) | 0.01–5 mg/L (for Cr(VI), Ni, Mn, Cu, Cr, Pb, Zn, Fe, Co, etc.) |
| Compliance | Aligns with EPA Method 7063, ISO 8692, GB/T 5750.6–2023, and ASTM D3559 |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PTB-2020 |
| Pricing | Upon Request |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | PTB-CL20 |
| Instrument Type | Portable |
| Measurement Principle | DPD Colorimetric Method (N,N-Diethyl-p-phenylenediamine) |
| Measurand | Free Residual Chlorine |
| Measurement Range | 0.01–10 mg/L (auto-ranging with dilution support for >2 mg/L) |
| Accuracy | ±5% FS |
| Resolution | 0.01 mg/L |
| Detection Limit | 0.01 mg/L |
| Data Storage | 1000 measurements with non-volatile memory |
| Display | 3.5" color LCD with Chinese GUI |
| Power Supply | 5 × AA rechargeable or alkaline batteries (1.2 V each) |
| Operating Temperature | 5–40 °C |
| Operating Humidity | <85% RH (non-condensing) |
| Dimensions | 200 × 100 × 70 mm |
| Weight | 0.5 kg |
| Light Source | Solid-state cold LED (lifetime >50,000 h) |
| Compliance | Designed per ISO 7393-2 and EPA Method 334.0 principles |
| Battery Life | >10 hours continuous operation |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | SCI-025 |
| Sampler Type | Automatic Proportional Water Sampler |
| Sampling Method | Time-Proportional & Flow-Proportional |
| Single Sample Volume | 1–9999 mL (adjustable) |
| Sampling Volume Accuracy | ±5% |
| Proportional Sampling Accuracy | ±10% |
| Sampling Rate | 100–1200 mL/min (adjustable) |
| Sampling Interval | 1–9999 minutes (adjustable) |
| Maximum Suction Lift | ≤8 m |
| Sample Bottle Capacity | ≤1000 mL |
| Number of Sample Bottles | 1–24 |
| Refrigerated Storage Temperature | 4 °C ±1 °C |
| Operating Ambient Temperature | −20 °C to +60 °C |
| Power Supply | AC 220 V, 50 Hz, ±15% |
| Dimensions (W×D×H) | 1050 × 550 × 550 mm |
| Weight | ≤60 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | ZYKX |
| Price Range | USD 14,000 – 28,000 |
| CO₂ Range | 0–3000 ppm |
| Accuracy | ±(1% FS + 1.5% RDG) |
| Channel Capacity | 1–16 configurable |
| Data Logging Interval | 1–60 min adjustable |
| Operating Temp | −20 to +60 °C |
| Operating Humidity | 0–100% RH (non-condensing) |
| Power Supply | 12 VDC |
| Chamber Dimensions | Ø160 mm × 170 mm H |
| Cable & Tubing Length | Standard 5 m (customizable) |
| Display | LCD |
| Memory | 2 MB standard (expandable) |
| Communication | USB / RS-232 / GPRS (SIM card & data plan not included) |
| Chamber Actuation | Motor-driven slow-close mechanism with pressure compensation |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX-08 |
| Instrument Type | Portable/handheld water quality analyzer |
| Measured Parameters | pH, Nitrite (NO₂⁻), Hydrogen Sulfide (H₂S), Ammonia Nitrogen (NH₃-N), Dissolved Oxygen (DO), Temperature, Salinity, Residual Chlorine |
| Measurement Principle | Colorimetric (for NO₂⁻, NH₃-N, H₂S, residual chlorine) and electrochemical/optical probe-based (for DO, pH, temperature, salinity) |
| DO Range | 0–12 mg/L |
| pH Range | 0–14 |
| Temperature Range | 0–50 °C |
| Salinity Range | 0–50 ppt |
| Residual Chlorine Range | 0–2.5 mg/L |
| NH₃-N Range | 0–10 mg/L |
| NO₂⁻ Range | 0–0.3 mg/L |
| H₂S Range | 0–12 mg/L |
| DO Resolution | 0.001 mg/L |
| pH Resolution | 0.1 |
| Temperature Resolution | 0.1 °C |
| Salinity Resolution | 0.1 ppt |
| Repeatability | ≤2% |
| Accuracy | ±5% FS (full scale) |
| Power Supply | 4 × 1.5 V button cells |
| Housing | Anodized aluminum alloy |
| Compliance | Designed for field-deployable aquaculture monitoring per ISO 7027 (turbidity reference), ASTM D1293 (pH), ASTM D888 (DO), and EPA 365.3 (phosphate-free colorimetric methods) |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX-700 |
| Instrument Type | Handheld Weather Station |
| Temperature Range | −50 °C to +80 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| RH Range | 0–100% |
| RH Resolution | 1% |
| RH Accuracy | ±2% |
| Barometric Pressure Range | 100–1300 hPa |
| Pressure Resolution | 0.1 hPa |
| Pressure Accuracy | ±0.3 hPa |
| Wind Speed Range | 0–75 m/s |
| Wind Speed Resolution | 0.1 m/s |
| Wind Speed Accuracy | ±(0.3 m/s or 3%) |
| Wind Direction Range | 0–360° |
| Wind Direction Resolution | 1° |
| Wind Direction Accuracy | ±3° |
| Rainfall Measurement Principle | Optical |
| Rainfall Resolution Options | 0.001 mm / 0.01 mm / 0.2 mm |
| Power Input | 12–30 V DC |
| Heating Power | 30 W |
| Communication Interface | RS485 (RS232 optional) |
| MTBF | 8500 h |
| Operating Temperature | −50 °C to +80 °C |
| Storage Temperature | −50 °C to +80 °C |
| Power Supply Options | Mains, Solar, or Hybrid |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Model | ZYKX-JY12 |
| Rainfall Intensity Range | 20–200 mm/h |
| Rainfall Area | 12 m² (3 m × 4 m, customizable) |
| Rainfall Height | 4 m (customizable) |
| Uniformity Coefficient | >0.90 |
| Droplet Diameter Range | 0.4–8 mm |
| Intensity Adjustment Resolution | 6 mm/h |
| Response Time for Intensity Change | <30 s |
| Rain Gauge Orifice Diameter | Φ200 ± 0.6 mm |
| Rain Gauge Resolution | 0.1 mm |
| Controller Power Supply | AC 220 V, 50 Hz |
| Operating Temperature | 0–60 °C |
| Operating Humidity | ≤95% RH |
| Data Logger Storage Capacity | Unlimited (user-configurable) |
| Sampling Interval | ≥3 s (adjustable) |
| Communication Interface | RS232 |
| Design Service Life | >15 years |
| Self-Priming Pump | Head = 35 m, Flow Rate = 15 m³/h |
| Water Storage Tank Volume | 1 m³ |
| Nozzle Types | Three interchangeable stainless-steel nozzles (Φ9 mm, Φ11 mm, Φ13 mm), each with 45° spray angle and distinct flow/pressure characteristics enabling composite intensity modulation |
| Brand | ZYKX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | ZYS350 |
| Pricing | Upon Request |
| Detector | Si-PIN |
| Excitation Source | 45 kV / 200 µA Ag-anode micro-focus X-ray tube with integrated high-voltage generator |
| Elemental Range | Si (Z=14) to U (Z=92) |
| Quantified Elements | 37 heavy metals including Cr, Mn, Fe, Co, Ni, Cu, Zn, As, Se, Sr, Y, Zr, Mo, Ag, Cd, Sn, Sb, Ba, Hg, Pb, Bi, plus Si, S, K, Ca, Sc, Ti, V, Rb, Nb, I, Eu, Yb, Lu, Hf, Ga, Ge |
| Sample Form | Solid & powdered soils |
| Analysis Method | Fundamental Parameters (FP) + Direct Reading |
| Software | TECSYNC™ Remote Control Platform (Windows PC & Android mobile compatible) |
| Weight | ≤1.7 kg (with battery) |
| Display | 5″ industrial-grade transflective touchscreen (1080×720) |
| Battery | Rechargeable Li-ion, 6800 mAh, 7.2 V, >8 h continuous operation |
| Connectivity | Wi-Fi, Bluetooth 5.0, email report export, cloud sync |
| Safety | Auto X-ray shutdown when no sample detected |
| Environmental Rating | Operating temp: –20 °C to +60 °C |
| humidity | ≤90% RH non-condensing |
| Certification | CE, RoHS, ISO 9001, ASTM E1621–22 (XRF for soil screening), EPA Method 6200 compliant |
| Brand | Zyuyou |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | GA-6D |
| Pricing | Upon Request |
| Dilution Ratio Range | 1:1 to 1:100 (customizable) |
| Display | 7-inch capacitive touchscreen |
| Gas Path Materials | Passivated stainless steel tubing & PTFE tubing |
| Integrated Pump | Diaphragm pump (ambient pressure operation) |
| Output Channels | 6 independent concentration outlets |
| Control Method | Mass flow controllers (MFCs) |
| Operation Modes | Single-point dilution or multi-concentration sequential dilution |
| Data Management | Built-in method storage and recall |
| Software Interface | Multi-channel configurable, intuitive parameter setting |
| Origin | Shenzhen, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | μChem NIA 2000 |
| Price Range | USD 28,000 – 35,000 |
| Measured Parameters | Total Nitrogen (TN), Total Phosphorus (TP) |
| Instrument Type | Online Analyzer |
| Measurement Principle | Spectrophotometry (UV-Vis) |
| Detection Limit | 0.001 mg/L |
| Accuracy | ±3% of reading |
| Resolution | 0.001 mg/L |
| Power Consumption | 8 W (operational), 1.2 W (standby) |