| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Aerosol Black Carbon Analyzer |
| Measurement Principle | Optical Attenuation (Filter-Based Transmission) |
| Wavelength Channels | 7-channel (370, 450, 520, 590, 660, 880, 950 nm) |
| Primary Output | Black Carbon Mass Concentration (µg/m³) and Wavelength-Dependent Absorption Coefficient (Mm⁻¹) |
| Compliance | QX/T 68–2007 (China Meteorological Administration Standard) |
| Flow Control | Integrated Precision Mass Flow Controller |
| Detection System | Dual Photodetector Correction + Charge-Integrating ADC Architecture |
| Data Output | Real-time, Continuous, On-line |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Type | Online Multicomponent Gas Analyzer |
| Detection Principle | Low-Temperature Preconcentration + Thermal Desorption + Capillary GC Separation + PID Detection |
| Response Rate | >40 °C/s (Heating Ramp Rate) |
| Sampling Method | Mass-Flow-Controlled (MFC) |
| Detector | High-Sensitivity Photoionization Detector (PID) |
| Column Technology | Capillary GC with Valve-Switched Backflush |
| Carrier Gas Control | Electronic Pressure Control (EPC) |
| Compliance | Designed for Continuous Emission Monitoring (CEM) and Ambient Air Quality Monitoring per EPA TO-15 / ISO 16017-1 |
| Sample Handling | Integrated Preconcentration Trap with Direct Resistive Heating |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BPM-200 |
| Measurement Principle | Beta-Ray Attenuation Method (β-ray) |
| Safety Rating | Explosion-Proof (Class I, Division 1, Group A–D compliant per UL 1203 / IEC 60079-0) |
| Sampling Flow Rate | 16.7 L/min (standardized per ISO 10473 and EPA PM2.5 Reference Method EQPM-0805-190) |
| Particle Size Cuts | TSP, PM₁₀, PM₂.₅ (interchangeable impactors) |
| Compliance | Meets technical requirements of HJ 653–2013 (China), EN 12341:2014, and compatible with US EPA Federal Equivalent Method (FEM) framework for continuous ambient PM monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | BPM-200M |
| Measurement Principle | Beta-ray Absorption (¹⁴C source) |
| Measured Parameters | PM₁₀ / PM₂.₅ |
| Measurement Ranges | 0–10 mg/m³, 0–20 mg/m³, 0–50 mg/m³, 0–100 mg/m³ (selectable) |
| Sampling Flow Rate | 2 L/min |
| Lower Detection Limit | 5 µg/m³ |
| Flow Stability | ≤ ±2% of setpoint over 24 h |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Buoy-3000 |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Ammonia-N, Total Phosphorus (TP), Total Nitrogen (TN), UV-COD, pH, Dissolved Oxygen (DO), Turbidity, Temperature, Chlorophyll-a, Phycocyanin (for Cyanobacteria), Oil-in-Water |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | BWATER-1000 |
| Instrument Type | Online Water Quality Analyzer |
| Measurable Parameters | COD, TOC, BOD₅, Turbidity, Color, Total Suspended Solids (TSS), Nitrate, Nitrite, Specific UV Absorbance at 254 nm (SUVA₂₅₄) |
| Compliance Standard | T/CWEC 13–2019 |
| Detection Principle | Dual-Beam UV-Vis Absorption Spectroscopy (190–800 nm) |
| Response Time | ≤15 s |
| Deployment Mode | Submersible In Situ Probe |
| Data Transmission | 4G Cellular Real-Time Uplink |
| Maintenance Interval | ≥3 months (with automatic cleaning cycle) |
| Reagent-Free Operation | Yes |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM/ODM) |
| Country of Origin | China |
| Model | BWATER-2000EX |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | BWATER-3100 |
| Output Interface | RS485 Modbus RTU / 4–20 mA analog |
| Measurement Principle | Time-of-Flight (ToF) at 60 GHz |
| Blind Zone | ≤10 mm |
| Resolution | 1 mm |
| IP Rating | IP68 |
| Average Power Consumption | 0.3 W |
| Operating Frequency | 60 GHz |
| Installation | Top-mounted, non-contact |
| Signal Processing | Adaptive surface fluctuation filtering |
| Dimensions | Ø50 mm × H95 mm |
| Brand | FPI (Hangzhou Focus Science & Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | CDMS-1000 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Response Time | 4 s |
| Measured Parameters | SO₂, NO, O₂, Relative Humidity, Flue Gas Temperature, Static Pressure, Flow Velocity, Particulate Matter (PM) |
| Detection Principle | NDIR (SO₂, CO), UV Absorption (NO), Electrochemical Cell (O₂), Capacitive/Hygrometric (Humidity), PT100/Thermocouple (Temperature), Piezoresistive (Pressure), Pitot Tube or Ultrasonic (Flow Velocity), Light Scattering / Beta Attenuation (PM) |
| Communication Interface | RS485, 4–20 mA, Ethernet, Modbus TCP/RTU, OPC UA |
| Compliance | GB/T 16157, HJ 75–2017, HJ 76–2017, ISO 12039, EN 15267, EN 14181 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000 B FT |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measurement Principle | Fourier Transform Infrared Spectroscopy |
| Accuracy | ≤ ±2% of Full Scale (F.S.) |
| Repeatability / Span Drift | ≤ ±2% F.S. over 7 days |
| Response Time | ≤ 180 s |
| Zero Drift | ≤ ±2% F.S. over 7 days |
| Operating Temperature | Sample Path Heated to 180 °C |
| Interferometer | Patented ROCKSOLID™ Dynamic Alignment-Free Design |
| Calibration | Automated Zero and Span Calibration |
| Compliance | Designed for EPA Method 320, ISO 12039, EN 15267-3, and applicable EU IED & US Clean Air Act requirements |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | CEMS-2000 B VOC |
| Instrument Type | Online Gas Chromatographic Analyzer |
| Configuration | Multi-Detector VOC Analyzer (FID + PID in series) |
| Detection Principle | Gas Chromatography with Flame Ionization and Photoionization Detection |
| Compliance | Designed for EPA Method 25A, ASTM D6348, ISO 13864, and compatible with China’s HJ 1013–2018 and HJ 75–2017 standards |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ±2% F.S. for ranges ≤100 mg/m³ |
| Repeatability | Span drift ≤±2% F.S./24 h |
| Response Time | ≤180 s (with heated sampling line ≤70 m) |
| Stability | Zero drift ≤±2% F.S./24 h |
| Measured Parameters | Gaseous pollutants (SO₂, NOₓ, O₂, CO, CO₂), particulate matter (PM), flue gas temperature, pressure, velocity, and humidity |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 D |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | SO₂, NOₓ (NO + NO₂), O₂, H₂O (wet-basis) |
| Analytical Methods | Ultraviolet Fluorescence (SO₂), Chemiluminescence (NOₓ), Capacitive Humidity Sensing (H₂O), Zirconia Electrochemical Cell (O₂) |
| System Architecture | Dilution-extractive sampling with integrated calibration, data acquisition, and communication modules |
| Compliance Framework | Designed to support compliance with GB/T 16157, HJ 75–2017, HJ 76–2017, and compatible with EPA Method 6C / 7E / 3A / 4 for reference equivalence |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CEMS-2000 VOC |
| Instrument Type | Continuous Emission Monitoring System (CEMS) |
| Measured Parameters | Methane / Non-Methane Hydrocarbons (NMHC), BTEX (Benzene, Toluene, Ethylbenzene, Xylenes), Target VOC Species, Particulate Matter (PM) Concentration, Flue Gas Temperature, Pressure, and Velocity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B |
| Instrument Type | Flue Gas Continuous Emission Monitoring System |
| Measurement Accuracy | ≤ ±1% FS |
| Repeatability | ≤ ±0.5% FS/24h (Span Drift) |
| Response Time | ≤ 200 s |
| Stability | ≤ ±1% FS/24h (Zero Drift) |
| Measured Parameters | Gaseous Pollutants (SO₂, NO, NO₂, CO, CO₂, O₂), Particulate Matter (PM), Temperature, Pressure, Flow Velocity, Humidity |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | CEMS-2000B Hg |
| Pricing | Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Flue Gas Heavy Metal Analyzer |
| Measurement Principle | Energy-Dispersive X-Ray Fluorescence (ED-XRF) |
| Elemental Coverage | Pb, Hg, Cr, Cd, As, and up to 26 heavy metals (expandable via spectral library calibration) |
| Detection Limit | < 0.1 µg/m³ (for key elements under ISO 14927-compliant sampling conditions) |
| Filter Replacement Interval | ≥ 30 days (typical, dependent on particulate loading) |
| Operating Ambient Temperature | 0–40 °C |
| Operating Ambient Humidity | 10–90 % RH (non-condensing) |
| Operating Ambient Pressure | 86–106 kPa |
| Compliance | Meets China’s HJ 1131–2020 and EU EN 14385 technical requirements for continuous heavy metal emission monitoring |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | COD-2000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Potassium Dichromate Oxidation–Spectrophotometric Method |
| Measurement Range | 0–200 / 0–500 / 0–2000 mg/L COD |
| Accuracy | ≤ ±10% of reading |
| Repeatability | ≤ 3% RSD |
| Limit of Detection | 10 mg/L COD |
| Zero Drift (24 h) | ±5 mg/L |
| Maintenance Interval | Up to 30 days without service intervention |
| Reagent Consumption | <10%–20% of conventional segmented flow systems |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | FPI DS7000 Series |
| Safety Rating | Explosion-Proof (Class I, Division 1, Groups C/D |
| Measurement Principle | Electrostatic Induction Sensing |
| Compliance | CE, RoHS, GB/T 18204.1–2013 (China), IEC 60079-0:2017, IEC 60079-1:2014 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | EasyChem Online |
| Instrument Type | Online Water Quality Analyzer |
| Detection Principle | Discrete Analysis with Photometric and Fluorescence Detection |
| Maximum Parameters | 15 |
| Form Factor | Integrated Benchtop Unit |
| Compliance | Designed for ISO 5667, ASTM D1293, EPA 150.1–150.3, and GB/T 5750 series applications |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | EPMS-2000 |
| Pricing | Available upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ETMS-100 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ETMS-100 Online Monitoring System |
| Pricing | Available upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | ETMS-300 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Atmospheric Heavy Metal & VOC Online Analyzer |
| Model | Expec-3000 |
| Compliance | Designed for ISO 16000-6, ASTM D6196, USP <467>, and EPA TO-15/TO-17 workflows |
| Sample Introduction | Cryogenic pre-concentration coupled with thermal desorption |
| Detection Modes | Dual-channel GC-FID (C₂–C₅ hydrocarbons) and GC-MS (C₆–C₁₂ & oxygenated VOCs) |
| Analyte Coverage | >100 target VOCs including alkanes, alkenes, aromatics, halocarbons, aldehydes, ketones, esters, and organic acids |
| Data Handling | Fully automated peak integration, spectral deconvolution, and NIST library matching |
| System Architecture | 19″ rack-mountable, air-cooled cryogenic module, integrated GLP-compliant audit trail |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Extractive FTIR |
| Configuration | Online Continuous Monitoring System |
| Optical Resolution | 1 cm⁻¹ |
| Effective Path Length | Adjustable from 10 m to 64 m |
| Detector Operating Temperature | −196 °C (Liquid Nitrogen Cooled MCT) |
| Detection Limit | Sub-ppb for Selected Analytes |
| Spectral Library | >300 Certified Reference Spectra (Developed with Anhui Institute of Optics and Fine Mechanics, CAS |
| Simultaneous Quantification | ≥20 Gaseous Species (e.g., VOCs, CO, CO₂, NH₃, SO₂, NO, HCl, HF, CH₄) |
| Interference Compensation | Multi-point Calibration + Multi-spectral Band Fitting Algorithm |
| Sample Handling | Direct Extractive Sampling — No Pre-concentration or Chemical Derivatization Required |
| Compliance Readiness | Designed for ASTM D6348, ISO 12039, EPA Method 320, and GLP/GMP-aligned Data Integrity Frameworks |
| Software Architecture | Supports 21 CFR Part 11 Audit Trail, Electronic Signatures, and Secure Data Export (CSV, XML, PDF) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | FMSW-1000 |
| Pricing | Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | GC-1010 |
| Pricing | Available Upon Request |
| Channel Configurations | 10-channel (GC-1010) / 2-channel (GC-1010-C) |
| Power Supply Output | 24 VDC active output (1 channel) |
| Display | LCD + high-brightness LED indicators |
| Communication Interfaces | RS-485 and Ethernet |
| Signal Input Compatibility | 2-wire and 3-wire toxic & combustible gas detectors |
| Alarm Logic | Multi-sensor intelligent voting algorithm |
| Data Acquisition | Synchronized multi-channel sampling |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GC-1020 |
| Pricing | Upon Request |
| Channel Capacity | 10-channel |
| Display | Dual-mode — 10-digit high-brightness LED + LCD |
| Input Compatibility | 2-wire & 3-wire toxic/combustible gas sensors |
| Communication | RS485 (Modbus RTU standard), optional Ethernet interface |
| Analog Output | Optional 10-channel 4–20 mA |
| Power Output | 1-channel 24 VDC active output |