| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9310 / 9350 |
| Flow Rate | 28.3 L/min (9310) / 50 L/min (9350) |
| Particle Size Range | 0.3–20 µm (9310), 0.5–20 µm (9350) |
| Detection Efficiency | 50% at 0.3 µm (9310), 50% at 0.5 µm (9350) |
| Maximum Concentration | 400,000 particles/ft³ (9310), 250,000 particles/ft³ (9350), 5% coincidence error |
| Data Storage | 10,000 samples |
| Display | 5.7-inch color touchscreen |
| Operating System | Microsoft Windows CE |
| Power | Rechargeable Li-ion battery (4 h runtime for 9310, 3.5 h for 9350) |
| Compliance | ISO 14644-1, FS-209E, EC GMP, JIS B9921, CE |
| Calibration | NIST-traceable |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AeroTrak™ 9306 |
| Particle Size Range | 0.3–20 µm |
| Channel Options | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm (NIST-traceable calibration) |
| Counting Efficiency | 50% at 0.3 µm |
| Maximum Concentration | 2,000,000 particles/ft³ (5% coincidence error) |
| Sample Flow Rate | 2.83 L/min (1 CFM) |
| Light Source | Laser Diode |
| Zero Count | <1 count/5 min (JIS B9921 compliant) |
| Data Storage | 1500 sampling points in device memory |
| Display | 3.7-inch color touchscreen with Microsoft Windows® CE OS |
| Power | Rechargeable Li-ion battery (6 hr continuous operation) |
| Dimensions | 25.4 × 11.4 × 7.6 cm (L×W×H) |
| Weight | 1.0 kg (with battery) |
| Environmental Operating Range | 5–35 °C, 20–95% RH (non-condensing) |
| Standards Compliance | ISO 21501-4, JIS B9921, CE, US FDA 21 CFR Part 11 (via TRAKPRO™ software audit trail), ISO 14644-1, FS-209E, EC GMP Annex 1 |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AP500 |
| Atmospheric Pressure Range | 517.1–930.9 mmHg (20.36–36.65 inHg) |
| Accuracy (Pressure) | ±2% of reading |
| Operating Temperature (Electronics) | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Battery | Rechargeable Li-ion, 3500 mAh |
| Runtime | >8 h at 0.5 m/s, 25 °C |
| Display | OLED, 10 mm digit height |
| Dimensions (W×L×D) | 53 × 181 × 40 mm |
| Weight (with battery) | 0.23 kg |
| Wind Speed Range (VT-S/VTH-S/VT-A/VTH-A) | 0–30 m/s |
| Wind Speed Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) |
| Wind Speed Resolution | 0.01 m/s |
| Temperature Range (all probes) | −10–65 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Relative Humidity Range (VTH-S/VTH-A/TH-S) | 5–95 %RH |
| RH Accuracy | ±3 %RH |
| RH Resolution | 0.1 %RH |
| Probe Length (straight/hinged) | 305 mm |
| Max Probe Diameter | 9.5 mm |
| Hinge Section Length (VT-A/VTH-A) | 152.4 mm |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | AP800 |
| Differential Pressure Range | –3735 to +3735 Pa |
| Accuracy | ±1% of reading ±1 Pa |
| Resolution | 0.1 Pa |
| Air Velocity Range (with Pitot tube) | 1.27–78.7 m/s |
| Velocity Accuracy | ±1.5% at 10.16 m/s |
| Barometric Pressure Range | 517.1–930.9 mmHg |
| Operating Temperature | 5–45 °C |
| Display | OLED, 10 mm digit height |
| Dimensions | 53 × 181 × 40 mm |
| Weight | 0.20 kg (with battery) |
| Battery Life | >32 hours |
| Connectivity | Bluetooth Low Energy (BLE), USB-C charging, microSD data logging |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | APS-3321 |
| Pricing | Available Upon Request |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533EP |
| Instrument Type | Real-time Aerosol Mass Concentration Monitor |
| Detection Principle | 90° Light Scattering (Laser Photometry) |
| Mass Concentration Range | 0.001–150 mg/m³ |
| Simultaneous Size-Fractionated Outputs | PM₁, PM₂.₅, Respirable (PM₄), PM₁₀, and Total PM (<15 µm) |
| Flow Rate | 3.0 L/min (±5% accuracy, internally controlled) |
| Optical System | Sheath-Air Isolated Laser Cavity |
| Display | 5.7″ VGA Color Touchscreen |
| Data Storage | 5 MB internal memory (>60,000 data points |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Time Constant | User-selectable (1–60 s) |
| Resolution | ±0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Zero Stability | ±0.002 mg/m³ over 24 h |
| Particle Size Range | 0.1–15 µm |
| Power | Rechargeable Li-ion battery (2.0 kg w/1 battery |
| Connectivity | USB, Ethernet (8533EP only), USB mass storage support |
| Analog Output | User-selectable 0–5 V or 2–20 mA |
| Alarm Output | Relay (non-latching MOSFET) or audible buzzer |
| Filter Holder | Replaceable 37 mm filter cassette (user-supplied) |
| Compliance | Designed for use in occupational health monitoring per OSHA, NIOSH, and ISO 7708 air sampling protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | DustTrak II 8532 |
| Measurement Principle | 90° Light Scattering |
| Particle Size Range | 0.1–10 µm |
| Mass Concentration Range | 0.001–150 mg/m³ |
| Resolution | ±0.1% of reading or 0.001 mg/m³ (whichever is greater) |
| Zero Stability | ±0.002 mg/m³ over 24 h (10-s averaging time) |
| Flow Rate | Factory-set at 3.0 L/min, user-adjustable from 1.40–3.0 L/min |
| Flow Accuracy | ±5% at factory-set point with internal flow control |
| Temperature Coefficient | +0.001 mg/m³/°C |
| Selectable Fractional Cuts | PM₁, PM₂.₅, PM₄, PM₁₀ (integrated sharp-cut cyclones) |
| Data Memory | 5 MB (>60,000 data points at 1-min interval |
| Recording Interval | 1 s–1 h, programmable |
| Time Constant | 1–60 s, user-selectable |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Temperature | −20–60 °C |
| Dimensions (H×W×D) | 12.5 × 12.1 × 31.6 cm |
| Weight | 1.3 kg (bare), 1.5 kg (with Li-ion battery) |
| Display | 3.5″ VGA color touchscreen |
| Power | Rechargeable lithium-ion battery (internal/external charging) |
| Certifications | CPA certified (UK), CE compliant (EN 61326-1:2006 for immunity & emissions) |
| Alarm | Visual and audible (user-configurable setpoints, ±5% deadband) |
| Interface | USB port for data export |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | DUSTTRAK™ II 8530 |
| Measurement Range | 0.001–400 mg/m³ |
| Resolution | Greater of 0.1% of reading or 0.001 mg/m³ |
| Sensor Principle | 90° Light Scattering |
| Flow Rate | 3.0 L/min (adjustable 1.4–3.0 L/min) |
| Particle Size Range | 0.1–15 µm |
| Data Memory | 5 MB (>60,000 points at 1-min interval) |
| Operating Temperature | 0–50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Display | 5.7″ VGA color touchscreen |
| Communication | USB, Ethernet, USB flash drive export |
| Analog Output | User-selectable 0–5 V or 4–20 mA |
| Alarm Output | Relay and/or audible buzzer |
| Filter Holder | Replaceable 37 mm cassette |
| Compliance | EN 61326-1:2006 (EMC immunity & emissions) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | Edge 4 Plus Personal Noise Dosimeter |
| Instrument Type | Handheld Noise Dosimeter |
| Measurement Range | 70–140 dB |
| Accuracy Class | Class 2 (per IEC 61672-1:2013) |
| Battery Life | ≥40 hours (typical usage, display timeout enabled) |
| Microphone | ¼″ pre-polarized electret condenser, field-replaceable |
| Frequency Weightings | A, C, and Z |
| Exchange Rate Options | 3 dB, 4 dB, or 5 dB |
| Dose Counters | Dual independent dosimeters |
| Compliance Presets | OSHA 1910.95 & ACGIH TLV® preconfigured |
| Display | Full-color OLED screen |
| Connectivity | Bluetooth® 4.2 LE |
| App Compatibility | iOS 10.0+, Android 4.3+ |
| Enclosure | IP54-rated housing |
| Mass | 85 g (3 oz) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | EDGE 5 |
| Instrument Type | Handheld Noise Dosimeter |
| Measurement Range | 70–140 dB |
| Accuracy Class | Class 2 (per IEC 61252 & ANSI S1.25) |
| Battery Life | ≥40 hours |
| Certifications | ATEX, IECEx (Simtars), MSHA, CSA (US/Canada), UL |
| Ingress Protection | IP65 |
| Weight | 85 g |
| Dimensions | 89 × 53 × 19 mm |
| Microphone | 1/4″ pre-polarized electret condenser (field-replaceable) |
| Frequency Weightings | A, C, Z |
| Exchange Rates | 3 dB, 4 dB, or 5 dB (user-selectable per dosimeter channel) |
| Dose Channels | Three independent simultaneous dose calculations |
| Presets | OSHA 1910.95, ACGIH TLV® |
| Data Logging | L<sub>avg</sub>, L<sub>eq</sub>, L<sub>max</sub>, Peak, Overload events, Minute-interval energy averaging |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5725 |
| Velocity Range | 0.25–30 m/s |
| Accuracy | ±1% of reading or ±0.02 m/s (whichever is greater) |
| Temperature Range | 0–60 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Duct Area Range | 0–16 m² |
| Data Storage | 12,700 readings across 100 data groups |
| Sampling Interval | 1 s – 1 h |
| Time Constant | User-adjustable |
| Operating Temperature | 5–45 °C |
| Probe Operating Temperature | 0–60 °C |
| Storage Temperature | −20–60 °C |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 270 g |
| Power | 4 × AA alkaline batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 5815, 5825 |
| Pressure Range | −3735 to +3735 Pa (−28.0 to +28.0 mmHg) |
| Pressure Resolution | 0.1 Pa, 0.001 mmHg |
| Pressure Accuracy | ±1% of reading, ±0.01 mmHg, or ±1 Pa (whichever is greater) |
| Air Velocity Range (with Pitot Tube) | 1.27–78.7 m/s |
| Air Velocity Resolution | 0.1 m/s |
| Air Velocity Accuracy | ±1.5% at 10.16 m/s |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Data Storage Capacity | 12,700 readings across up to 100 data sets |
| Sampling Interval | 1 s to 1 h |
| Dimensions | 8.4 × 17.8 × 4.4 cm |
| Weight (with batteries) | 0.27 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Volume Flow Calculation | Supported via user-defined duct dimensions (1–635 mm, 0.1 mm increments) and programmable K-factor |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7515 |
| Instrument Type | Portable |
| Resolution | 1 ppm |
| Response Time | 20 s |
| Measurement Range | 0–5000 ppm |
| Accuracy | ±3.0% of reading or ±50 ppm (whichever is greater) |
| Power Supply | 4 × AA batteries |
| Operating Temperature | -20 to 60 °C |
| Dimensions (main unit) | 8.4 × 17.8 × 4.4 cm |
| Probe Dimensions | 7 cm length × 1.9 cm diameter |
| Sensor Technology | Dual-wavelength NDIR (Non-Dispersive Infrared) |
| Certification | CPA Pattern Approval Certificate (P.R. China) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7525 |
| CO₂ Sensor Type | Dual-Wavelength NDIR |
| CO₂ Range | 0–5000 ppm |
| CO₂ Accuracy | ±3.0% of reading or ±50 ppm (whichever is greater) |
| CO₂ Resolution | 1 ppm |
| CO₂ Response Time | 20 s (t₉₀) |
| Temperature Sensor | Thermistor |
| Temp Range | 0–60 °C |
| Temp Accuracy | ±0.5 °C |
| Temp Resolution | 0.1 °C |
| Temp Response Time | 30 s (at 2 m/s air velocity, t₉₀) |
| RH Sensor | Thin-Film Capacitive |
| RH Range | 5–95 %RH |
| RH Accuracy | ±3.0 %RH |
| RH Resolution | 0.1 %RH |
| RH Response Time | 20 s (t₆₃) |
| Outdoor Air Percentage Calculation | 0–100 % |
| Resolution | 0.1 % |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −20–60 °C |
| Dimensions (Instrument) | 8.4 × 17.8 × 4.4 cm |
| Probe Length | 17.8 cm |
| Probe Diameter | 1.9 cm |
| Time Constants | 1, 5, 10, 20, 30 s |
| Logging Interval | 1 s to 1 hr (user-selectable) |
| Data Storage Capacity | Up to 30,300 records |
| Weight (with batteries) | 0.27 kg |
| Power | 4 × AA batteries or optional AC adapter |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 7545 |
| Measured Parameters | CO₂, CO, Temperature, Relative Humidity |
| Derived Parameters | Dew Point Temperature, Wet-Bulb Temperature, Outdoor Air Fraction (calculated) |
| Sensor Technology | NDIR (CO₂), Electrochemical (CO), Capacitive (RH), Thermistor (Temperature) |
| Data Logging | Internal memory with timestamped records |
| Interface | USB for data download via TSI LogDat2™ software |
| Compliance | Designed to support ASHRAE 62.1, ISO 16814, and EN 13779 indoor air quality assessment protocols |
| Brand | TSI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | 8475 |
| Instrument Type | Thermal Anemometer |
| Resolution | 0.07% of Selected Full-Scale Range |
| Measurement Range | 0.05–2.54 m/s |
| Accuracy | ±1.0% of Selected Full-Scale Range |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8525 |
| Operating Principle | Condensation Nucleus Counting (CNC) via Isopropanol-based Growth |
| Particle Size Range | 2 nm to >1 µm |
| Concentration Range | 0–5×10⁵ cm⁻³ |
| Sample Flow Rate | 0.1 L/min |
| Total Flow Rate | 0.7 L/min |
| Operating Temperature | 0–38 °C |
| Storage Temperature | −40 to 70 °C |
| Power Supply | 6 × AA batteries (6 h runtime at 21 °C) |
| Alcohol Requirement | Reagent-grade isopropanol (8 h per fill at 21 °C) |
| Data Interface | RS-232 (9600 baud) |
| Internal Memory | 470 independent measurement points |
| Logging Interval | 1 min |
| Max Continuous Logging Duration | 1000 hours |
| Test ID Capacity | 141 unique IDs |
| Dimensions | 270 × 140 × 140 mm |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8533/8534 |
| Measurement Principle | 90° Light Scattering (650 nm Laser Diode) |
| Safety Rating | Intrinsically Safe (Class I, Division 1, Groups A–D) |
| Concentration Range | 0.001–100 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±10% of reading (traceable to ISO 12103-1 A1 test dust) |
| Relative Error | ≤±2% |
| Particle Size Range | 0.1–10 µm |
| Flow Rate | Adjustable 0–1.8 L/min |
| Operating Temperature | 0–50 °C |
| Storage Temperature | −20–60 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Data Logging Capacity | ~80,000 points |
| Battery Life | >20 h @ 1.7 L/min with PM₂.₅ cyclone |
| Time Constant Options | 1, 5, 10, 15, 30 s |
| Alarm Outputs | Audible (95 dB), Visual (flashing red LED & OLED), Configurable Thresholds (0.001–999 mg/m³) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8715 |
| Differential Pressure Range | ±3735 Pa (Max Safe Operating Pressure: 37350 Pa) |
| Accuracy | ±2% of reading ± 0.25 Pa |
| Resolution | 0.001 Pa |
| Absolute Pressure Range | 356–1016 mmHg |
| Absolute Pressure Accuracy | ±2% of reading |
| Resolution | 1 mmHg |
| Air Velocity Range (Pitot Tube) | 0.13–41 m/s |
| Air Velocity Range (Air Flow Probe) | 0.13–25 m/s |
| Air Velocity Range (Velocity Matrix) | 0.13–13 m/s |
| Air Velocity Accuracy | ±3% of reading ± 0.036 m/s (for v > 0.254 m/s) |
| Resolution | 0.1 m/s |
| Temperature Range (Probe-Dependent) | −40 to 121 °C |
| Temperature Accuracy | ±0.3 °C (0–71 °C), ±0.6 °C (−40–0 °C and 71–121 °C) |
| Resolution | 0.1 °C |
| Relative Humidity Range | 0–95% RH |
| RH Accuracy | ±3% RH |
| Resolution | 0.1% RH |
| Averaging Capacity | Up to 1000 data points (pressure or velocity) |
| Measurement Interval | Continuous or user-selectable (10–600 s) |
| Response Time | 2–8 s |
| Time Constant Options | 1, 5, 10, 15, 20 s |
| Operating Temperature | 4.4–60 °C |
| Dimensions | 188 × 114 × 58 mm |
| Weight | 0.5 kg (including batteries) |
| Power | Four AA alkaline or NiMH rechargeable batteries, or AC adapter |
| Battery Life | ~12 h (alkaline) |
| Internal Charging Time | 5 h |
| External Charging Time | 1 h |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9515 |
| Air Velocity Range | 0–20 m/s |
| Resolution | 0.01 m/s |
| Accuracy | ±5% of reading or ±0.025 m/s (whichever is greater) |
| Temperature Range | –18 to 93 °C |
| Temperature Accuracy | ±0.3 °C |
| Temperature Resolution | 0.1 °C |
| Probe Length | 101.6 cm |
| Probe Tip Diameter | 7.0 mm |
| Probe Base Diameter | 13.0 mm |
| Host Dimensions | 8.4 × 17.8 × 4.4 cm |
| Operating Temperature (Host) | 5–45 °C |
| Storage Temperature | –20–60 °C |
| Weight (with batteries) | 0.27 kg |
| Power Supply | 4 × AA alkaline or NiCd batteries |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model Variants | 9535, 9535-A, 9545, 9545-A |
| Resolution | 0.01 m/s |
| Measurement Range | 0–30 m/s |
| Accuracy | ±3% of reading or ±0.015 m/s (whichever is greater) |
| Data Storage | 12,700 points across 100 data sets |
| Sampling Interval | 1 s to 1 h |
| Power | 4 × AA batteries or optional AC adapter |
| Weight (with batteries) | 0.27 kg |
| Probe Length | 101.6 cm (rigid), 19.7 cm (articulating) |
| Probe Diameter | 7.0 mm (rigid), 9.5 mm (articulating) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 9550 |
| Sample Flow Rate | 50 L/min |
| Minimum Detectable Particle Size | 0.5 µm |
| Compliance | ISO 14644-1, ISO 21501-4, EU GMP Annex 1, FS-209E |
| Sampling Volume per 20 min | 1 m³ |
| Compatibility | TSI Air Velocity/Temperature/Humidity Probe, FMS5 Monitoring System |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | 8030 |
| Fit Factor Range | 1 to >10,000 |
| Accuracy | ±10% of reading |
| Particle Sampling Flow Rate | 350 cm³/min |
| Total Flow Rate | 1000 cm³/min (nominal) |
| Operating Temperature | 0–38°C (32–100°F) |
| Storage Temperature | −40–70°C (−40–160°F) |
| Power Input | 100–250 VAC, 50–60 Hz |
| Dimensions (H×W×D) | 17 × 22 × 24 cm |
| Weight (main unit) | 2.7 kg (5.0 lb) |
| Weight (with case & accessories) | 7.3 kg (16 lb) |
| Alcohol Supply | ≥99.5% isopropyl alcohol (IPA), ~240 hours runtime at 21°C |
| Pass/Fail Threshold | User-selectable from 0 to 10,000 |
| Compliance | OSHA 29 CFR 1910.134, ISO 16900-1:2016, EN 13274-3:2008 |
| Software | FITPRO™ Fit Test Software (Windows XP/Vista compatible) |
| Optional Accessories | Model 8907 Thermal Printer, Model 8025 Test Kit, Mask Sampling Adapter Kit |
| Note | N95 respirator testing requires Model 8038 upgrade kit |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SE-402-IS |
| Instrument Type | Class 1/2 Integrating-Averaging Sound Level Meter |
| Certification | ATEX/IECEx Intrinsically Safe (IS) |
| Compliance | IEC 61672-1:2013 (Class 1), ANSI S1.4-2014 (Type 1), ANSI S1.43-2020 |
| Dynamic Range | 30–140 dBA (single-range), Peak SPL: 143 dB |
| Measurement Functions | L<sub>EQ</sub>/L<sub>AVG</sub>, L<sub>MAX</sub>, L<sub>MIN</sub>, L<sub>PK</sub>, L<sub>E</sub>, Time-Weighted (A/C/Z), Exchange Rate Options (3/4/5 dB) |
| Response Modes | Fast & Slow |
| Microphone | Optional Class 1 (QE4936) or Class 2 (QE7052) |
| Data Logging | 2 MB internal memory (~34 days at 1-min interval) |
| Power | Rechargeable Li-ion (1500 mAh), 8 h typical runtime (IS mode), USB charging |
| Environmental Rating | IP65 (housing only), Operating Temp: −10 °C to +50 °C, Drop Tested: 2 m (front/back, 2× each) |
| Physical Dimensions | 284 × 71 × 33 mm (11.2" × 2.8" × 1.3"), Weight: 410 g (incl. preamp & microphone) |
| Connectivity | Mini-USB 2.0, AC/DC analog output (non-IS models only), RS-232 (non-IS models only) |
| Accessories Supported | Quest DMS Software (sold separately), optional digital printer, 15 m remote measurement cable (non-IS models only) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SD-200 |
| Instrument Type | Handheld Sound Level Meter |
| Measurement Range | 45–130 dB |
| Accuracy Class | IEC/ANSI Class 2 |
| Compliance Standards | ANSI S1.4-1983 (R2006), ANSI S1.43-1997 (R2007), IEC 61672-1:2002, IEC 61010-1:2010 |
| Dimensions | 16.5 × 6.1 × 2.3 cm |
| Weight | 125 g |
| Power Source | Rechargeable Li-polymer battery (1000 mAh), >50 h runtime (LED off) |
| Microphone | Omnidirectional electret condenser, Class 2 |
| Frequency Weighting | A or C |
| Time Weighting | Fast or Slow |
| Exchange Rate (ER) | 3 dB or 5 dB |
| Operating Temperature | 0–40 °C |
| Relative Humidity | 0–90 % RH (non-condensing) |
| Tripod Mount | 1/4"-20 threaded socket |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SE-400 Series |
| Measurement Range | 30–140 dB(A) |
| Accuracy Class | Class 2 per IEC 61672-1:2013 |
| Dynamic Range | 110 dB(A) |
| Peak SPL | 143 dB(A) |
| Frequency Weighting | A, C, Z |
| Time Weighting | Fast, Slow |
| Metrics | L<sub>EQ</sub>, L<sub>AVG</sub>, L<sub>MAX</sub>, L<sub>MIN</sub>, L<sub>Pk</sub>, L<sub>E</sub>, Exposure Time |
| IP Rating | IP65 (housing only) |
| Operating Temperature | −10 °C to +50 °C |
| Battery Life | Up to 18 h (standard), 8 h (IS model) |
| Memory | 2 MB internal (≈34 days @ 1-min logging) |
| Compliance | IEC 61672-1:2013, ANSI S1.4-2014, ANSI S1.43-2012, CE |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SidePak AM520 |
| Measurement Principle | 90° Light Scattering (650 nm Laser Diode) |
| Safety Rating | Non-Explosive |
| Concentration Range | 0.001–100 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Zero Stability | ±0.001 mg/m³ over 24 h (10 s time constant) |
| Particle Size Range | 0.1–10 μm |
| Flow Rate | User-Adjustable 0–1.1 L/min |
| Operating Temperature | 0–50 °C |
| Battery Life | >20 h at 1.7 L/min with PM2.5 cyclone |
| Data Storage | ~80,000 points |
| Compliance | Calibrated per ISO 12103-1 using A1 test dust and gravimetric reference method for respirable fraction |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SMPS-3938 |
| Size Range | 2.5–1000 nm |
| Resolution | Up to 167 channels per scan |
| Scan Time | <10 s |
| Concentration Range | Up to 1×10⁷ particles/cm³ |
| Compliance | ISO 15900:2009 |
| Detector Options | Butanol or Water-based CPCs |
| Neutralizer Options | Radioactive (⁸⁵Kr) or Non-radioactive (Bipolar Corona) |
| Control Interface | Integrated touchscreen, PC-free operation |
| Software | TSIGuard™ and Instrument Manager™ (PC required for full data analysis) |
| Brand | TSI |
|---|---|
| Origin | USA |
| Model | SoundPro™ SE-DL |
| Instrument Type | Handheld Noise Measurement Instrument |
| Accuracy Class | Class 1 or Class 2 (IEC 61672-1:2013, ANSI S1.4-2014) |
| Frequency Weighting | A, C, and Z (Linear) |
| Time Weighting | Fast, Slow, Impulse (IEC 61672) |
| Dynamic Range | 10 dB to 140 dB |
| Exchange Rate Options | 3 dB, 4 dB, 5 dB, or 6 dB |
| Data Logging Interval | 1 second to 60 minutes |
| Storage | Removable SD card |
| Connectivity | USB + RS-232 serial output |
| Display | Backlit graphical LCD with multilingual UI |
| Calibration | Internal reference tone + external acoustic calibrator compatible |
| Noise Dose Calculation | Enabled per OSHA 1910.95 & ISO 1999 |
| Real-time Octave Band Analysis | 1/1-octave (31.5 Hz – 8 kHz), conforming to IEC 61260-1:2014 |