| Brand | ADCON |
|---|---|
| Origin | Germany (Manufactured for HACH) |
| Model | Pro |
| Wind Speed Range | 0.4–270 km/h |
| Startup Wind Speed | <0.4 m/s |
| Wind Speed Sensor | Three-cup aluminum rotor with low-friction bearings |
| Wind Direction Sensor | Precision Hall-effect transducer with aluminum/stainless-steel vane |
| Housing Material | Anodized aluminum, seawater-corrosion resistant |
| Mounting | 80 cm mast arm with universal bracket |
| Cable Configuration | Integrated PENTAX connector + Y-split cable (dual-sensor interface to single ADCON RTU port) |
| Compliance | WMO-recommended installation geometry and performance criteria |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | RG1 |
| Resolution | 0.1 mm (400 cm² collector) / 0.2 mm (200 cm² collector) |
| Collection Area | 200 cm² or 400 cm² |
| Accuracy | ±2% up to 60 mm/h |
| Output | Reed switch pulse (dry contact, hermetically sealed, Meder Germany, >1 million actuations) |
| Operating Temperature | 0 °C to +75 °C |
| Weight | 0.5 kg |
| Housing Material | Anodized aluminum |
| Cable | 1 m PUR shielded cable with PENTAX 7-pin M9 male connector |
| Compliance | Compatible with ADCON A723/A733/A753 RTUs |
| Mounting | Pole- or surface-mountable |
| Heating | Not integrated |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SEN-R |
| Price | Upon Request |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SP-lite |
| Pricing | Available Upon Request |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | SR11 |
| Output Signal | 0–2.5 V DC (with integrated amplifier) |
| Sensitivity | 15 µV/(W/m²) |
| Spectral Range | 305–2800 nm |
| Max. Irradiance | 2000 W/m² |
| Temp. Coefficient of Sensitivity | ±0.1 %/°C |
| Operating Temperature | −40 °C to +80 °C |
| Long-term Instability (per year) | < ±1 % |
| Non-linearity (0–1000 W/m²) | < ±2.5 % |
| Tilt Response (at 1000 W/m²) | < ±3 % |
| Compliance | ISO 9060:2018 Class A, ISO 9847 |
| Dimensions (incl. mounting mast) | 420 × 355 × 150 mm (L × W × H) |
| Weight | 2.6 kg |
| Cable | 3 m shielded cable with PENTAX 7-pin connector |
| Compatible RTUs | A723, A733, A75x series |
| Brand | Adcon |
|---|---|
| Origin | Imported |
| Model | TR1 |
| Power Supply Voltage | 5.5–15 VDC |
| Current Consumption | <1.5 mA typical |
| Operating Temperature Range | −40 °C to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| RH Accuracy | ±2 %RH (0–90 %RH at +20 °C), ±3 %RH (90–100 %RH at +20 °C) |
| RH Long-Term Stability | <1 %RH/year |
| RH Temperature Coefficient | ±0.03 %RH/°C |
| Temperature Accuracy | ±0.2 °C at +20 °C |
| Temperature Sensor | Pt1000 (DIN Class A) |
| Output Signal | 0–2.5 VDC (dual-channel, independent for T & RH) |
| Enclosure Material | Tecapet® |
| Ingress Protection | IP65 |
| Dimensions | Ø12 mm × 101 mm |
| Weight | 13 g |
| Connector | 8-pin M12 male |
| Filter Cap | Stainless steel mesh cap (sintered metal cap optional) |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Wet |
| Power Supply | 5.5–12 VDC |
| Output Signal | 0–2.5 VDC |
| Dimensions | 45 × 90 × 90 mm |
| Weight | 500 g |
| IP Rating | IP66 |
| Operating Temperature | −20 to +60 °C |
| Relative Humidity Range | 0–100 %RH |
| Sensing Principle | Capacitive Condensation |
| Repeatability | ±3 % |
| Housing Material | PTFE-coated ceramic sensor element |
| Cable | 3 m, 7-pin waterproof PENTAX connector |
| Mounting | Integrated mast clamp for Ø40–50 mm poles |
| Part Number | 200.733.060 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Ion-Selective Electrode (ISE) Method |
| Measurement Range | 0–1000 mg/L NH₄–N and 0–1000 mg/L K⁺ |
| Accuracy | ±5% of reading + 0.2 mg/L |
| Measurement Mode | Continuous Real-Time Monitoring |
| Calibration | Built-in Matrix Calibration with Auto-Compensation for Interfering Ions |
| Sensor Architecture | Integrated CARTRICAL™ Sensor Cartridge (K⁺-ISE, pH Reference Electrode, and Temperature Sensor in Single Housing) |
| Controller Compatibility | Digital SC Platform Integration |
| Optional | Automated Cleaning Module |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | American Sigma 900 / 900MAX |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Ammonia-N Prepackaged Reagent Series |
| Price | USD 120 (approx. based on ¥950 at standard exchange rate) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Analyzer |
| Measurement Principle | Colorimetric Distillation Method |
| Measurement Range | 0.2–1200 mg/L NH₄–N |
| Accuracy | ≤ ±5% (varies by range |
| Detection Limit | 0.2 mg/L NH₄–N |
| Measurement Interval | User-definable (13 min to 24 h) |
| Batch Capacity | >10 samples per cycle |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | Amtax NA8000 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Salicylate–Indophenol Blue Method |
| Measurement Range | NA8000.01: 0.020–160.0 mg/L (auto-ranging) |
| NA8000.02 | 0.020–1000 mg/L (auto-ranging with dilution) |
| Accuracy | 0.020–15.00 mg/L: ±(0.06 mg/L or 3%) |
| 0.050–30.00 mg/L | ±(0.15 mg/L or 3%) |
| 12.00–160.0 mg/L | ±(0.90 mg/L or 3%) |
| 80.00–1000 mg/L | ±10% |
| Detection Limit | 0.02 mg/L |
| Measurement Cycle | 10–15 minutes |
| Repeatability | ≤2% (low range) to ≤3% (high range) |
| Display Resolution | 0.001 mg/L (≤9.999), 0.01 mg/L (10.00–99.99), 0.1 mg/L (100.0–999.9), 1 mg/L (≥1000) |
| Power Consumption | 100 W |
| Sampling Pressure | 0.04–1 bar (0.6–14.5 psi) |
| Sampling Flow Rate | 100–600 mL/min |
| Sampling Temperature | 5–40 °C |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Enclosure Rating | IP55 (indoor use only) |
| Dimensions (L×W×H) | 455 × 365 × 805 mm |
| Weight | ~28 kg (excl. reagents) |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Outputs | 2 × 24 VDC/3 A SPDT relays |
| Data Storage | 20,000 records |
| Event Log Capacity | 20,000 entries (retained for ≥2 years) |
| Calibration | Automatic, manual, or remote-triggered |
| Sample Pretreatment Compatibility | CYQ-series water samplers (e.g., CYQ-106C, CYQ-104C) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | AMTAX sc |
| Measurement Principle | Gas-Sensing Electrode (Ammonia-Selective Electrode) |
| Measurement Ranges (as NH₄-N) | Low Range: 0.05–20 mg/L |
| Medium Range | 1–100 mg/L |
| High Range | 10–1000 mg/L |
| LOD | 0.05 mg/L (low), 1 mg/L (medium), 10 mg/L (high) |
| Accuracy | ±3% ±0.05 mg/L (low), ±3% ±1.0 mg/L (medium), ±4.5% ±10 mg/L (high) |
| Repeatability | ±2% ±0.05 mg/L (low), ±2% ±1.0 mg/L (medium), ±2% ±10 mg/L (high) |
| Response Time (T₉₀) | ≤5 min |
| Measurement Interval | Adjustable from 5 to 120 min |
| Sample Temp. | 4–40 °C |
| Sample pH | 5–9 |
| Operating Temp. | −20–45 °C |
| Relative Humidity | ≤95% non-condensing |
| Power Supply | 230 VAC/50 Hz or 115 VAC/50–60 Hz |
| Power Consumption | 100 W nominal (peak: 1000 VA) |
| Enclosure Rating | IP66 |
| Sample Flow Rate | ≤3 m/s |
| Filtrate Flow | ≥5 mL/min for ≥4 min per 5-min cycle |
| External Cabinet Dimensions | 540 × 720 × 390 mm |
| Analyzer Weight | 35 kg (incl. reagents) |
| Cable Length | 2 m from enclosure |
| Optional Heated Sampling Hose | 5 m or 10 m |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | HACH Company |
| Model | Amtax™ Compact |
| Instrument Type | Online Analyzer |
| Measurement Principle | Gas-Phase Separation with Colorimetric Detection (Nesslerization-based) |
| Range Options | 0.2–12.0 mg/L NH₄–N |
| Accuracy | ±2.5% of reading or ±0.2 mg/L (whichever is greater, per certified standard solution) |
| Detection Limit | 0.5 mg/L NH₄–N |
| Cycle Time | 13–120 min (user-selectable) |
| Output Signals | 4–20 mA (max. load 500 Ω) |
| Digital Interfaces | RS485 / RS232 with Modbus RTU or PROFIBUS DP protocol support |
| Alarm Outputs | Two programmable relay outputs (24 V DC, 1 A each) |
| Sample Channels | Dual-inlet capability (two independent sample streams) |
| Brand | HACH |
|---|---|
| Model | Amtax™ inter2 |
| Measurement Principle | Indophenol Blue Method (DIN 38406-E5) |
| Measurement Ranges | 0.02–2.00 mg/L NH₄–N, 0.1–20.0 mg/L NH₄–N, 1.0–80 mg/L NH₄–N |
| Accuracy | ±2% of reading |
| Cycle Time | 5, 10, 15, 20, or 30 minutes (user-selectable) |
| Calibration | Manual or automated (scheduled or event-triggered) |
| Maintenance Interval | Every 6 months |
| Reagent Consumption | Reagents A/B: 4–8 weeks |
| Zero & Span Standards | 12 months |
| Cleaning Solution | 6–12 months (dependent on cleaning frequency) |
| Analog Outputs | Two isolated 0/4–20 mA outputs (max. load 500 Ω) |
| Alarm Outputs | Two relay outputs (24 VDC, 1 A) |
| Digital Communication | MODBUS RTU (RS-485) or PROFIBUS DP |
| Operating Ambient Temperature | 5–40 °C |
| Power Supply | 230 VAC ±10%, 50 Hz |
| Power Consumption | ~310 VA (including integrated refrigerator) |
| Sample Pretreatment | Compatible with HACH FILTRAX® sampling and filtration system |
| Optical System | Dual-beam photometer with dual interference filters |
| Internal Refrigeration | Yes (for reagent stabilization at 4–8 °C) |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Portable |
| Measurement Principle | Ion-Selective Electrode (ISE) |
| Sensor Architecture | Integrated CARTRICAL Cartridge with pH, Temperature, and Selective Electrodes |
| Calibration | Factory-Calibrated Cartridge |
| Maintenance Interval | ~2x per year (typical operation) |
| Sample Handling | No pretreatment required |
| Controller Compatibility | SC100 / SC200 / SC1000 Digital Controllers |
| Housing Material | Stainless Steel Body with Ryton End Caps |
| Immersion Rating | Fully Submersible |
| Mounting Options | Rod, Chain, or Wall-Mount Kits |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.05–1999 ppb C |
| Accuracy | ±0.5 ppb or ±5% of reading, whichever is greater |
| Detection Limit | 0.05 ppb C |
| Repeatability | ±0.05 ppb (for TOC < 5 ppb) |
| Conductivity Range for Sample Inlet | 0.05–5 µS/cm (Auto Mode), 0.05–100 µS/cm (Clean Mode) |
| Maximum Inlet Pressure | < 100 psig (690 kPa) |
| Display Resolution | 0.01 ppb (0.00–19.99 ppb), 0.1 ppb (20.0–199.9 ppb), 1 ppb (200–1999 ppb) |
| Sensor Options | S10, S20, or S20P |
| Communication | RS-485 (Modbus RTU) |
| Data Output | Local print support, real-time analog output (4–20 mA), digital interface |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online TOC Analyzer |
| Model | A-1000XP |
| Detection Principle | Direct Conductivity Measurement |
| Oxidation Method | UV Photolysis (185/254 nm) |
| Measurement Range | 0.05–1999 ppb C |
| Accuracy | ±0.05 ppb (MDL to 0.999 ppb) |
| Detection Limit | 0.02 ppb C |
| Conductivity Cell Temperature Control | ±0.01 °C |
| Inlet Water Resistivity Requirement (Auto Mode) | 15.0–18.2 MΩ·cm |
| Inlet Conductivity Range (Clean Mode) | 0.05–100 µS/cm |
| Max Inlet Pressure | 100 psig (690 kPa) |
| Display Resolution | 0.001 ppb C |
| Communication Interfaces | RS-232 (local printing), RS-485 (modbus RTU, up to 1200 m) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | ASX-7200 |
| Dimensions (H×W×D) | 45.7 cm × 56.9 cm × 53.7 cm |
| Weight | 19.5 kg (43 lbs) |
| Sample Tray Capacity | 36 sealed HACH vials |
| Communication Interface | RS232 |
| Power Supply | 100–240 VAC ±10%, 50/60 Hz, 1.9 A |
| Warranty | 2 years |
| Fluidic Path Materials | PTFE and PEEK (metal-free, inert) |
| Positioning System | Motorized X-Y-Z Cartesian coordinate arm with high-torque stepper motors |
| Environmental Protection | Conformal-coated PCBs, sealed electronics enclosure, plated lead screws |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Manufacturer |
| Model | Anatel PAT700 |
| Measurement Range | 0.5–2,000 ppb C TOC |
| Repeatability | ±0.3 ppb or ±1% (whichever is greater) |
| Accuracy | ±1 ppb or ±5% (whichever is greater) |
| TOC Resolution | 0.1 ppb |
| Conductivity/Resistivity Resolution | 0.01 µS/cm or MΩ·cm |
| Temperature Resolution | 0.1 °C |
| Conductivity Compensation | Temperature-compensated and non-temperature-compensated modes |
| Inlet Pressure | 10–100 psig (69–690 kPa) |
| Flow Rate | 60–300 mL/min |
| Analog Outputs | Three 4–20 mA |
| Digital I/O | Two digital inputs, four digital outputs |
| Communication Interfaces | RS232, USB, Ethernet, Serial printer port |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | TOC600 |
| Instrument Type | Online TOC Analyzer |
| Detection Principle | Direct Conductivity Method |
| Oxidation Method | UV Photolysis |
| Measurement Range | 1–1000 ppb C |
| Accuracy | ±2% (10–40 °C), ±5% (40–50 °C) |
| Resolution | 1 ppb C |
| Repeatability | ±1% or ±1 ppb (whichever is greater) |
| Inlet Conductivity Range | 0.05–150 mS/cm |
| Inlet Pressure | 10–100 psig (69–690 kPa) |
| Flow Rate | 60–300 mL/min |
| Output Options | 4–20 mA, RS-232/RS-485 |
| Operating Environment | Ambient ≤70 °C (heat sink required above 70 °C) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer | Anatel (a HACH company) |
| Model | UP100 |
| Detection Sizes | 0.1 µm and 0.2 µm (customizable from 0.1–5.0 µm) |
| Sample Flow Rate | 10 mL/min |
| System Flow Rate | >1 L/min |
| Operating Pressure Range | 30–100 psig |
| Light Source | Laser Diode |
| Output | 4–20 mA |
| Clean Recovery Time | <60 seconds |
| Brand | HACH |
|---|---|
| Model | APA 6000 |
| Measurement Principle | Modified Phenol-Hypochlorite Colorimetry (ASTM D1426, ISO 7150-1) |
| Range | 0.02–2 mg/L as N (0.1–10 mg/L as Cl₂) |
| Accuracy | ±5% of reading or ±0.02 mg/L as N (whichever is greater) |
| Repeatability | ±3% of reading or ±0.01 mg/L as N (whichever is greater) |
| Detection Limit | 0.01 mg/L as N (0.05 mg/L as Cl₂) |
| Response Time (90%) | <5 min per cycle |
| Cycle Time | 5.0 min (average) |
| Sample Pressure | 0.03–2.04 bar |
| Sample Temperature | 5–50 °C |
| Sample Flow Rate | 100–2000 mL/min |
| Power Supply | 95–240 VAC, 50/60 Hz ±2 Hz |
| Enclosure Rating | NEMA 4X / IP66 (with air purge interface) |
| Dimensions (W×H×D) | 522 × 627 × 526 mm |
| Weight | 25.5 kg |
| Mounting Options | Wall-mounted, benchtop, or panel-integrated |
| Analog Outputs | 2 × 4–20 mA (expandable to 14) |
| Relay Outputs | 2 alarm relays (expandable to 14) |
| Data Storage | 30-day internal logging with trend and graphical analysis capability |
| Automation | Fully autonomous operation for ≥30 days with auto-calibration, auto-cleaning, and reagent dosing control |
| Sample Channels | Dual independent sample inlets (optional) |
| Brand | HACH |
|---|---|
| Model | APA6000 |
| Measurement Principle | Automated titration pump coupled with colorimetric detection |
| Range (Low) | 0.05–2.0 mg/L Cu²⁺ |
| Range (High) | 1.0–10.0 mg/L Cu²⁺ |
| Accuracy (Low) | ±3% or ±0.03 mg/L (whichever is greater) |
| Accuracy (High) | ±5% or ±0.05 mg/L (whichever is greater) |
| Resolution | 0.001 ppm |
| Repeatability | ±3% of reading or <±0.03 mg/L (whichever is greater) |
| Cycle Time | ~4 minutes per analysis |
| Display | Digital and graphical output calibrated to Cu²⁺ concentration |
| Sample Flow Rate | 20–1000 mL/min |
| Operating Temperature | 5–50 °C |
| Relative Humidity | ≤95% RH, non-condensing |
| Inlet Pressure | 0.17–6.9 bar |
| Calibration Frequency | Configurable from twice daily to once weekly (calibration duration: ~35 min) |
| Analog Outputs | Two isolated 4–20 mA outputs |
| Alarm Outputs | Two SPDT relays |
| Power Supply | 95–240 VAC, 50/60 Hz |
| Enclosure Rating | NEMA 4X (IP65) |
| Mounting Options | Panel-mount, benchtop, or wall-mount (hardware included) |
| Data Storage | 30-day onboard history with trend and graphical analysis capability |
| Maintenance Interval | Up to 30 days unattended operation |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | APA6000 |
| Measurement Principle | Flow Injection Analysis (FIA) with Photometric Detection at 600 nm |
| Range | Total Alkalinity: 0–500 mg/L as CaCO₃ |
| Phenolphthalein Alkalinity | 0–250 mg/L as CaCO₃ |
| Accuracy | ±5% of reading or ±1.0 mg/L (whichever is greater) |
| Repeatability | ±3% of reading or ±0.6 mg/L (whichever is greater) |
| Response Time (90%) | <10 min |
| Analysis Cycle | 8 min |
| Auto-Calibration Interval | 60 min |
| Sample Temperature | 5–50 °C |
| Analog Outputs | Two isolated 4–20 mA outputs, fully configurable across full scale |
| Alarm Outputs | Two SPDT relays (230 VAC, 5 A) |
| Power Supply | 95–240 VAC, 50/60 Hz ±2 Hz |
| Enclosure Rating | NEMA 4X (indoor) / IEC 529 IP66 with air-purge interface |
| Drain Connection | Vertical orientation recommended |
| Sample Flow Rate | 100–2000 mL/min |
| Inlet/Outlet Fittings | 1/4" NPT inlet, 3/4" NPT drain |
| Sample Pressure | 0.03–2.04 bar |
| Dimensions (W×H×D) | 522 × 627 × 526 mm |
| Mounting Options | Wall-mounted, benchtop, or panel-mounted |
| Weight | 25.5 kg |
| Data Storage | 30 days of timestamped results with trend/graphing capability |
| Key Features | Fully automated calibration, reagent replenishment, and system cleaning |
| Brand | HACH |
|---|---|
| Model | APA6000 |
| Measurement Principle | Colorimetric EDTA Complexation (USEPA-Approved Method) |
| Low-Range Range | 0.05–10 mg/L as CaCO₃ |
| High-Range Range | 10–1000 mg/L as CaCO₃ |
| Accuracy (Low) | ±5% or ±0.05 mg/L as CaCO₃, whichever is greater |
| Accuracy (High) | ±5% or ±2 mg/L as CaCO₃, whichever is greater |
| Repeatability (Low) | ±3% or ±0.03 mg/L as CaCO₃ |
| Repeatability (High) | ±5% or ±2 mg/L as CaCO₃ |
| T90 Response Time (Low) | ≤5 min |
| T90 Response Time (High) | ≤17 min |
| Cycle Time (Low) | 4 min |
| Cycle Time (High) | 8.2 min |
| Sample Temp. | 5–50 °C |
| Sample Flow Rate | 100–2000 mL/min |
| Inlet Pressure | 0.03–2.04 bar |
| Drain Fitting | 3/4″ NPT |
| Analog Outputs | Dual 4–20 mA (isolated, configurable for hardness or status) |
| Alarm Outputs | Two SPDT relays |
| Certifications | NRTL Listed (UL/CSA), CE Marked |
| Power Supply | 95–240 VAC, 50/60 Hz ±2 Hz |
| Data Storage | 30-day internal logging with timestamped values, trend plotting, and export via serial interface |
| Brand | Hach |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AS950 Series |
| Instrument Type | Portable / Refrigerated / All-Weather Automatic Water Sampler |
| Sampling Mode | Time-Proportional and Flow-Proportional Sampling |
| Sampling Configuration | Single-Bottle or Multi-Bottle (up to 24 bottles) |
| Bottle Capacity Options | 350 mL (standard base) or 575 mL (compact base) |
| Cooling Performance | Maintains sample temperature at 4 °C |
| Insulation | Dual-layer insulated base with ice retention capability |
| Enclosure Material | Chemical-resistant, UV-stabilized polymer (portable) |
| Environmental Rating | IP65-rated controls |
| Brand | HACH |
|---|---|
| Model | AS950 IO9000 |
| Type | Laboratory Water Sampler |
| Input | (2) 0/4–20 mA analog inputs |
| Output | (3) 0/4–20 mA analog outputs, (4) digital outputs, (1) high-voltage relay (IO9001) or (4) high-voltage relays (IO9004) |
| Operating Temperature | –40 to +50 °C |
| Storage Temperature | –40 to +80 °C |
| Enclosure Rating | NEMA 4X / IP66 |
| Certifications | cETLus |
| Weight | 2.5 kg |
| Dimensions (L×W×D) | 9.71 × 11.82 × 5.12 in |
| Cable Length | 2.74 m |