| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Model | GXH-3051E |
| Instrument Type | Portable |
| Detection Target | Single-component CO |
| Measurement Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤30 s |
| Zero Drift | ≤±1% F.S. |
| Span Drift | ≤±1% F.S. |
| Linearity Error | ≤±1% F.S. |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Model | GXH-3051L |
| Instrument Type | Portable |
| Detection Target | Single-component CO |
| Measurement Range | 0–50 ppm |
| Repeatability | ±1% F.S. |
| Resolution | 0.1 ppm |
| Response Time | ≤15 s |
| Zero Drift | ≤±1% F.S./24 h |
| Span Drift | ≤±1% F.S./24 h |
| Linearity Error | ≤±2% F.S. |
| Brand | Junfang Lihua |
|---|---|
| Origin | Beijing, China |
| Model | GXH-3052E |
| Instrument Type | Portable |
| Detection Target | Single-component CO₂ |
| Measurement Range | 0–1000 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 1 ppm |
| Response Time | ≤30 s |
| Zero Drift | ≤±1% F.S. |
| Span Drift | ≤±1% F.S. |
| Linearity Error | ≤±1% F.S. |
| Brand | Rikari Chemical |
|---|---|
| Origin | Japan |
| Model | H2O2-V1 |
| Measurement Principle | Molybdenum Yellow Spectrophotometry |
| Range | 0.0–120.0 g/L |
| Resolution | 0.1 g/L |
| Repeatability | ≤ ±5% FS |
| Response Time | <5 s after power-on |
| Measurement Time | ~60 s per sample |
| Auto-power-off | 5 s after measurement |
| Calibration | Zero calibration + span calibration using standard solution |
| Light Source | LED (stable narrow-band emission) |
| Power Supply | 4 × AA alkaline batteries (LR03, 6 V DC) |
| Dimensions | 88 W × 174 D × 65 H mm |
| Weight | ~310 g |
| Standard Accessories | Instrument body, 4 × AA batteries, H2O2-V1-RA reagent (500 mL), 5-mL syringe, 0.1-mL micropipette, instruction manual, warranty card, carrying case |
| Brand | MNK |
|---|---|
| Model | H300 |
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Canister Capacity | 1–4 (optional upgrade to 8–16) |
| Ultimate Vacuum | ≤ 0.007 mbar (≤ 0.05 torr) |
| Vacuum Pump | Edwards nXDSi 15i Dry Scroll Pump |
| Pump Displacement | 12.7 m³·h⁻¹ |
| Pump Ultimate Suction Speed | 11.4 m³·h⁻¹ |
| Cleaning Mode | Manual or Fully Automated Sequence |
| Optional Feature | Repetitive Thermal Desorption Cleaning Cycle |
| Brand | Huaai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | HA-9660-VOCs |
| Pricing | Upon Request |
| Compliance | HJ 1013–2018, HJ 1010–2018, HJ 1012–2018, GB 16297–1996, DB32/2862–2016, GB 18580–2017, HJ/T 400–2007 |
| Detection Principle | Gas Chromatography with FID/TCD/PDD Detectors |
| Sample Throughput | 50 mL/min |
| Carrier Gas | N₂/H₂/Ar/He (150 mL/min, 0.4 MPa) |
| Analysis Cycle | ≤2 min |
| LOD (NMHC) | ≤0.8 mg/m³ (≈0.13 µmol/mol) |
| Repeatability (RSD) | ≤2% |
| Linearity Error | ±2% F.S. |
| 24-h Drift | ±3% F.S. |
| Power | AC 220 V, 50–60 Hz, 400 W |
| Dimensions | 482 mm (W) × 222 mm (H) × 400 mm (D), 5U Rack-Mountable |
| Weight | 20 kg |
| Data Interface | RS-232/RS-485, Modbus RTU |
| Brand | HA-Ai |
|---|---|
| Model | HA-H2 |
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Detection Principle | Thermal Conductivity Detection (TCD) |
| Maximum Permissible Error | ±1%–±10% FS |
| Zero Drift | ≤1% FS/24h |
| Span Drift | ≤3% FS/24h |
| Repeatability | ≤2% RSD |
| Compliance | GB/T 37154–2018, GB/T 24549–2009 |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Status | Manufacturer |
| Instrument Type | Online TOC Analyzer |
| Oxidation Method | UV/Persulfate |
| Measurement Principle | NDIR Detection of CO₂ after Acidification and Catalytic Oxidation |
| Measurement Range | 0–5 mg/L to 0–20,000 mg/L (multi-range) |
| Accuracy | ±2% of reading (non-diluted), ±4% (diluted) |
| Detection Limit | ≤0.015 mg/L at 25°C (0–5 mg/L range) |
| Response Time | T₉₀ ≤ 8 min, T₂₀ ≤ 3 min |
| Sample Pressure | 0.15–6 bar (2–87 psig) |
| Flow Rate | 25–200 mL/min |
| Operating Temperature | 2–70°C (sample), 5–40°C (ambient) |
| Humidity | ≤80% RH at 31°C |
| Communication | RS232/RS485 (optional) |
| Analog Output | Dual 4–20 mA |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Dimensions | 981 × 675 × 20 mm |
| Weight | 54 kg |
| Compliance | USEPA Method 415.1, Standard Methods 5310C, ISO 8027 |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 4700102 |
| Measurement Principle | Nephelometric Turbidity (90° light scatter) |
| Range | 0–1000 NTU |
| Resolution | 0.01 NTU (0–9.99 NTU), 0.1 NTU (10–99.9 NTU), 1 NTU (100–1000 NTU) |
| Accuracy | ±2% of reading or ±0.01 NTU (whichever is greater) |
| Light Source | Tungsten filament lamp (ISO 7027-compliant) |
| Detector | Silicon photodiode |
| Calibration | Up to 6-point user-defined calibration with standard reference suspensions (Formazin or StablCal) |
| Compliance | EPA Method 180.1, ISO 7027, ASTM D6508, USP <241>, GLP-compliant data logging |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Hach 2582sc Trace Dissolved Oxygen Analyzer |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3100 |
| Instrument Type | Portable |
| Measurement Principle | Fluorescence Quenching |
| Measurement Range | 0–25 ppm |
| Accuracy | ±1% of reading or ±0.02 ppm (whichever is greater) |
| Repeatability | ±0.01 ppm |
| Detection Limit | 0.01 ppm |
| Sensor Drift | <1% per year |
| Response Time | ≤60 s |
| Operating Temperature | 0–60 °C |
| Storage Temperature | −20–70 °C |
| Relative Humidity | 0–100% RH |
| Enclosure Rating | NEMA 4X |
| Max Pressure Rating | 100 psi |
| Cable Length | 6.1 m (20 ft) |
| Weight | 1.8 kg (4 lb) |
| Display | Backlit, UV-resistant LCD with adjustable contrast |
| Data Output | RS232 serial interface |
| Data Logging | Internal memory with export capability |
| Power | Rechargeable internal battery |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 3150 |
| Instrument Type | Portable |
| Price Range | USD $2,800 – $7,200 (FOB) |
| Measurement Principle | Single-Beam Infrared Absorption |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 5000 Online Silicon |
| Measurement Range | 0–5000 ppb as SiO₂ |
| Detection Limit | <0.5 ppb |
| Accuracy | ±0.5 ppb or ±1.0% of reading (whichever is greater) |
| Response Time | 8.8 min (sample temperature 30–50 °C) |
| Ambient Operating Temperature | 10–45 °C |
| Sample Pressure Requirement | 5 ± 3 psig (34.5 ± 20.7 kPa) |
| Sample Flow Rate | 100–300 mL/min |
| Analog Outputs | 0–0.01 V, 0–0.1 V, 0–1 V, or 4–20 mA (user-configurable range) |
| Power Supply | 115/230 VAC, 50–60 Hz |
| Alarm Outputs | 2 concentration alarms, 1 system warning alarm, 1 system shutdown alarm |
| Enclosure Rating | NEMA 4X / IP65 (ABS plastic) |
| Mounting Options | Benchtop or panel-mount |
| Reagent Delivery | Patented pressure-driven reagent metering system |
| Calibration Modes | Programmable auto-calibration with three selectable methods |
| Channel Configuration | Configurable up to 8-channel silicon analysis |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 5000 Phosphate |
| Measurement Principle | Ascorbic Acid Method (Standard Colorimetric) |
| High-Range Measurement | 0–50.0 mg/L PO₄ |
| Low-Range Measurement | 0–5000 µg/L PO₄ |
| Accuracy (High Range) | ±0.5 mg/L or ±5% of reading (whichever is greater) |
| Accuracy (Low Range) | ±4 µg/L |
| Detection Limit | <0.2 mg/L |
| Resolution (Low Range) | 1 µg/L |
| Reagent Delivery | Patented Pressure-Driven System |
| Calibration Options | Manual, Scheduled Automatic, and Programmable Standard Addition |
| Zero Adjustment | Fully Automated per Cycle |
| Diagnostic Capability | Built-in Self-Diagnostic Alarms |
| Flow Interruption Response | Auto-Shutdown & Recovery Protocol |
| Reagent Consumption | Optimized for Extended Unattended Operation |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | HACH 5500sc |
| Instrument Type | Online Water Quality Analyzer |
| Measured Parameters | Total Ammonia, Monochloramine, Free Ammonia |
| Range | 0.01–2 ppm as N |
| Accuracy | ±5% or 0.01 ppm (as N) at 5–40 °C |
| Repeatability | ±3% or 0.01 ppm (as N), whichever is greater |
| Detection Limit | 0.01 ppm as N |
| Response Time | <5 minutes |
| Sample Flow Rate | 100–1000 mL/min |
| Operating Temperature | 5–45 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Sample Pressure | 0.17–6.0 bar |
| Sample Temperature | 5–50 °C |
| Power Output | 4 × 0/4–20 mA (600 Ω max load) |
| Communication Options | Modbus RS-485, Profibus DP (with external controller) |
| Enclosure Rating | NEMA 4X / IP56 |
| Dimensions | 804 × 452 × 360 mm |
| Weight | 20.5 kg (empty) |
| Certifications | CE, cETLus, Australian RCM |
| Brand | Hach |
|---|---|
| Model | 8315, 8316, 8317 |
| Construction Material | 316 Stainless Steel |
| Measurement Range | 0.057 µS/cm to 20,000 µS/cm |
| Compliance | ISO 7888, ASTM D1125 |
| Output Signal | 4–20 mA analog or digital (via Hach SC1000/SC200 controller) |
| Process Connection | 3/4" NPT or DIN 11851 sanitary thread (model-dependent) |
| Operating Temperature | 0–80 °C |
| IP Rating | IP68 |
| Calibration | Manual or automatic (with compatible Hach controllers) |
| Origin | USA |
|---|---|
| Type | Imported |
| Model | 9010m |
| Detection Principle | Polarographic DO Sensor |
| DO Range | 0.00–20.00 ppm |
| Air Saturation Range | 0.0–200.0 % |
| Temperature Range | −6.0–46.0 °C |
| DO Resolution | 0.01 ppm |
| Saturation Resolution | 0.1 % |
| Temperature Resolution | 0.1 °C |
| DO Accuracy | ±0.5 % of full scale |
| Saturation Accuracy | ±0.5 % of full scale |
| Temperature Accuracy | ±0.3 °C ±1 digit |
| Pressure Compensation | Adjustable from 600–1100 mbar (default: 1013 mbar) |
| Salinity Compensation | Adjustable from 0.0–40.0 ppt (default: 0.0 ppt) |
| Data Storage | 50 measurement sets |
| Power Supply | 9 V alkaline battery |
| IP Rating | IP67 |
| Dimensions | 70 × 186 × 37 mm |
| Weight | 260 g (without battery) |
| Certifications | CE, RoHS, CMC |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 9073 |
| Ion Type | Sodium |
| Measurement Range | 0–0.01 ppb and 0–10,000 ppm (user-selectable) |
| Repeatability | <5% of reading or ±0.05 ppb (whichever is greater) |
| Response Time (T90) | <2 min |
| Analog Outputs | Two 4–20 mA outputs (max. load: 900 Ω) |
| Operating Temperature | 5–45 °C |
| Power Supply | 220 VAC, 50/60 Hz |
| pH Conditioning Required | Yes (pH >10) |
| Electrode Type | Sodium-selective glass electrode |
| Calibration Method | AUTOCAL (automated 1- or 2-point standard addition) |
| Sample Handling | Integrated pH adjustment and acid-tolerant configuration available |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer | HACH Company (a Danaher subsidiary) |
| Product Type | Imported |
| Model | 9184sc |
| Pricing | Available upon Request |
| Brand | Hach |
|---|---|
| Origin | USA |
| Model | 9184sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor (HOCl-selective Membrane) |
| Measurement Parameter | Free Chlorine (as HOCl) |
| Range | 0.005–20 ppm (mg/L) HOCl |
| Accuracy | ±2% of reading or ±10 ppb HOCl (whichever is greater) |
| Detection Limit | 5 ppb (0.005 mg/L) HOCl |
| Response Time (t₉₀) | <90 seconds |
| Sample Flow Rate | 200–250 mL/min (automatically regulated) |
| Operating Temperature | 0–45 °C |
| Sample Temperature Range | 2–45 °C |
| Sample pH Range | 4–8 |
| Calibration Interval | Every 2 months |
| Membrane & Electrolyte Replacement Interval | Every 6 months |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions | 270 × 250 mm |
| Storage Temperature | −20–60 °C |
| Inlet/Outlet Fittings | 1/4″ O.D. inlet, 1/2″ I.D. outlet |
| Brand | HACH |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 9185sc |
| Pricing | Available Upon Request |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | 9187sc |
| Instrument Type | Online Analyzer |
| Measurement Principle | Electrochemical Amperometric Sensor |
| Measured Parameter | ClO₂ (Chlorine Dioxide) |
| Range | 0.010–2 ppm (mg/L) ClO₂ |
| Accuracy | ±5% of reading or ±10 ppb ClO₂, whichever is greater |
| Repeatability | 0.02 mg/L |
| Resolution | 0.01 ppm |
| LOD | 10 ppb (0.01 mg/L) ClO₂ |
| Response Time (t₉₀) | <90 s |
| Sample Flow Rate | 200–250 mL/min |
| Operating Temperature | 0–45 °C |
| Sample Temperature Range | 0–45 °C |
| Storage Temperature | −20 to 60 °C |
| Calibration Interval | Every 2 months |
| Membrane & Electrolyte Replacement Interval | Every 6 months |
| Inlet Connection | 1/4-in. O.D. tubing |
| Outlet Connection | 1/2-in. I.D. tubing |
| Enclosure Rating | IP66 / NEMA 4X |
| Dimensions | 270 × 250 mm (10.63 × 9.84 in.) |
| Brand | HACH |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | AccuChlor2 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Amperometric Electrochemical Sensor Method |
| Measured Parameters | Residual Chlorine (Free & Total) |
| Sample Temperature Range | 0–49 °C |
| Flow Rate | 150–600 mL/min (recommended: 500 mL/min) |
| Sample pH Range | 3.0–10.0 |
| Sample Alkalinity Range | 0.05–300 mg/L as CaCO₃ |
| Sample Turbidity Limit | < 252 NTU |
| Electrode Materials | Cathode – Gold |
| Buffer Solution | For Free Chlorine – distilled 5% food-grade white vinegar |
| Display | Graphical dot-matrix LCD (128 × 64 pixels), LED backlight, character height up to 13 mm |
| Measurement Range | Auto-ranging: 0–60.0 mg/L |
| Resolution | 0.001 mg/L (0–9.999 mg/L), 0.01 mg/L (10.0–60.0 mg/L) |
| Fixed-range mode | 0–60.0 mg/L, resolution 0.01 mg/L |
| Relay Outputs | 3 electromechanical relays |
| Analog Outputs | Two independent 4–20 mA outputs |
| Power Supply | 230 VAC ±10%, 50 Hz |
| Accuracy | ±0.1% of full scale |
| Sensitivity | ±0.05% of full scale |
| Repeatability | ±0.05% of full scale |
| Enclosure Rating | NEMA 4X / IP65 |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Model | A512 |
| Measurement Principle | Resistive Soil Water Potential (Tensiometric Equivalent) |
| Max. Sensors Supported | 3 × Standard ADCON Model 200 Sensors |
| Output Signal | 0–2.5 V analog |
| Input Range | 0–200 cBar |
| Accuracy | ±5% of full scale |
| Enclosure Material | Anodized aluminum |
| IP Rating | IP67 |
| Dimensions (L×W×H) | 100 × 110 × 50 mm (incl. cable glands & mounting bracket) |
| Cable | 3 m, 7-pin PENTAX 53 waterproof connector |
| Compatible RTUs | A720, A723, A732, A733 |
| Sensor Housing | Stainless steel with patented dual concentric electrode geometry embedded in hydrophilic matrix |
| Operating Temperature | –20 °C to +60 °C |
| Long-term Stability | Non-dissolving, freeze-thaw resistant, no gypsum degradation |
| Mounting Flexibility | Single-depth multi-sensor or multi-depth profiling configuration |
| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | BP1 |
| Measurement Range | 500–1500 mbar |
| Accuracy | ±0.1% FS (0–80°C) |
| Output Signal | 0.1–2.5 VDC |
| Linearity | ±0.025% FS |
| Long-term Stability | ≤1 mbar (for ranges ≤1 mbar) |
| Operating Temperature | −20°C to +80°C |
| Enclosure Material | Polycarbonate |
| Sensor Element Material | 316L Stainless Steel (DIN 1.4435) |
| Cable | 3 m PE-shielded, with PENTAX 7-pin waterproof connector |
| IP Rating | IP67 (sensor: IP68) |
| Supply Voltage | 3.5–12 VDC @ <3 mA |
| Shock Resistance | 20 g (11 ms) |
| Vibration Resistance | 20 g (5–2000 Hz, ±3 mm amplitude) |
| Pressure Cycle Endurance | 10 million cycles at 0–100% FS (25°C) |
| Housing Dimensions (incl. mounting bracket, vent, cable gland) | 145 × 90 × 70 mm |
| Sensor Dimensions | Ø21 × 121 mm |
| Weight (incl. 3 m cable) | 500 g |
| Brand | ADCON |
|---|---|
| Origin | Imported (Netherlands/Germany) |
| Manufacturer Type | Authorized Distributor |
| Model | CMP-3 |
| Compliance | ISO 9060:2018 Class C (Secondary Standard) |
| Spectral Range | 310–2800 nm |
| Sensitivity | 5–20 µV/W·m⁻² |
| Max Irradiance | 2000 W/m² |
| Temperature Coefficient of Sensitivity | ±5% (−10 °C to +40 °C) |
| Operating Temperature | −40 °C to +80 °C |
| Long-term Stability | ±1% per year |
| Non-linearity (0–1000 W/m²) | ±2.5% |
| Tilt Response (at 1000 W/m²) | ±3% |
| Output Signal | 0–2.5 V DC (integrated Adcon signal conditioner) |
| Cable | 2 m shielded cable with PENTAX 7-pin connector |
| Mounting | Pole-mount compatible with dual pipe clamps |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Application | Drip Irrigation System Efficiency Monitoring |
| Resolution | 1 mm (rainfall mode) / 5 g per tip (irrigation mode) |
| Collection Orifice Area | 50 cm² |
| Tip Volume | 5 g |
| Operating Temperature Range | −30 °C to +70 °C |
| Weight | 0.4 kg |
| Housing Material | Styrosun® |
| Cable | 5 m shielded cable with PENTAX 7-pin connector |
| Compatible RTUs | A723, A733, A753 series |
| Mounting | Pole-mounted with two pipe clamps |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | LP-02 |
| Calibration Standard | ISO 9060:2018 Class C (Secondary Standard) & WMO Guide (2018) |
| Spectral Range | 305–2800 nm |
| Sensitivity | 15 µV/(W·m⁻²) |
| Max Irradiance | 2000 W·m⁻² |
| Temp. Coefficient of Sensitivity | ±0.1 %/°C |
| Operating Temperature | −40 °C to +80 °C |
| Long-Term Stability (per year) | ±1 % |
| Non-Linearity (0–1000 W·m⁻²) | ±2.5 % |
| Tilt Response (at 1000 W·m⁻²) | ±3 % |
| Output Options | 0–2.5 V analog (with integrated Adcon amplifier) or mV-level thermopile signal (no amplifier) |
| Cable | 3 m shielded cable with PENTAX 7-pin connector |
| Mounting | Rigid pole-mount bracket |
| Dimensions (w/ bracket) | 420 × 355 × 150 mm (L×W×H) |
| Weight | 2.15 kg |
| Compliance | ISO 9060:2018, WMO No. 8, ASTM E824-94 |
| Brand | ADCON |
|---|---|
| Origin | Switzerland |
| Model | LVE1 |
| Pressure Ranges | 1, 3, 10 bar |
| Overpressure Limits | 3, 7, 20 bar |
| Output Signal | 0.1–2.5 V DC |
| Supply Voltage | 3.2–12 V DC |
| Accuracy (0–40°C) | ±0.1% FS |
| Resolution | < 0.01% FS |
| Long-term Stability | ≤1 mbar (for ranges < 2 bar), ≤0.1% FS (for ranges ≥ 2 bar) |
| Operating Temperature | −40°C to +80°C |
| Temp. Compensation Range | 0°C to +80°C |
| Probe Dimensions | Ø22 mm × 95 mm |
| Cable | Ventilated PE, standard 15 m (custom lengths available) |
| Connector | Binder 7-pin M9 male |
| IP Rating | IP68 (probe), IP67 (connector) |
| Wetted Materials | 316L stainless steel (DIN 1.4435), FKM fluorocarbon elastomer, polyethylene |
| Media Compatibility | Water, wastewater, groundwater, non-corrosive aqueous solutions |
| Brand | ADCON |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | PQS1 |
| Spectral Range | 400–700 nm ±4 nm |
| Sensitivity | 10–50 µV/µmol·m⁻²·s⁻¹ |
| Output Signal | 0–2.5 V (standard Adcon analog, with integrated amplifier) |
| Cable Length | 5 m (optional 15 m) |
| Response Time | <1 µs |
| Long-Term Drift | <2% per year |
| Nonlinearity (0–10,000 µmol·m⁻²·s⁻¹) | <1% |
| Cosine Response Error (up to 80° incidence at 1000 µmol·m⁻²·s⁻¹) | <30 µmol·m⁻²·s⁻¹ |
| Temperature Coefficient | −0.12%/°C |
| Field of View | 180° |
| Leveling Accuracy (integrated bubble vial) | ±0.2° |
| Detector Type | Silicon photodiode |
| Operating Temperature | −30°C to +70°C |
| Storage Temperature | −30°C to +70°C |
| Humidity Tolerance | 0–100% RH (non-condensing) |
| Ingress Protection | IP67 |