| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic |
| Model | OK-TS-80.000 |
| High Temperature Range | 150 °C |
| Low Temperature Range | −50 °C |
| Thermal Shock Range | −50 °C to 150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 10 °C/min |
| Cooling Rate | 10 °C/min |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-TS-80.001 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −50 °C |
| Thermal Shock Range | −50 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 10 °C/min |
| Cooling Rate | 10 °C/min |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-TS-80.11 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −50 °C |
| Thermal Shock Range | −50 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Temperature Transition Time | ≤10 s (basket transfer) |
| Heating/Cooling Rate (chamber ambient) | 20 °C/s (typical ambient recovery post-transfer) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OK-TS-80.120 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −50 °C |
| Thermal Shock Range | −50 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 10 °C/min |
| Cooling Rate | 10 °C/min |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OK-TS-80.22 |
| High Temperature Range | +150 °C |
| Low Temperature Range | −40 °C |
| Thermal Shock Range | −40 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 20 s (to reach target temperature after transfer) |
| Cooling Rate | 20 s (to reach target temperature after transfer) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-TS-80.25 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −70 °C |
| Thermal Shock Range | −70 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Transition Time (Hot ↔ Cold) | ≤10 s |
| Heating/Cooling Rate (Chamber Air) | 5 °C/s (typical air temperature ramp in transition phase) |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-TS-80.33 |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −40 °C |
| Thermal Shock Range | −40 °C to +150 °C |
| Temperature Stability | ±2 °C |
| Heating Rate | 5 °C/s |
| Cooling Rate | 5 °C/s |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | OK-TS-9 |
| Price | ¥89,000 |
| High-Temperature Range (°C) | 150 |
| Low-Temperature Range (°C) | -40 |
| Thermal Shock Range (°C) | -40 to 150 |
| Temperature Stability (°C) | ±2 |
| Heating Rate (°C/min) | 10 |
| Cooling Rate (°C/min) | 10 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-UV-290 |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| UV Lamp Power | 40 W per lamp |
| Irradiance | 0.72 W/m² |
| Illumination Temperature Range | RT to 70 °C |
| UV Wavelength | 300 nm |
| Chamber Dimensions (L×W×H) | 1170 × 400 × 400 mm |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,150 (FOB) |
| Internal Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temperature Control Accuracy | ≤±0.5 °C |
| Temperature Uniformity | ≤±2 °C (chamber) / ≤±3% (humidity) |
| UV Lamp Type | Fluorescent UV-B/UV-A tubes (e.g., UVA-340 or UVB-313 equivalent) |
| Spectral Range | 280–400 nm |
| Exposure Time | 0–999 h programmable |
| Chamber Material | Interior & exterior SUS#304 stainless steel |
| Heating System | U-shaped titanium alloy high-speed heating elements |
| Safety Features | Interlocked door cut-off for UV lamps, over-temperature protection, low-water level cutoff |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,100 (approx.) |
| Model | OK-UV-290 |
| Interior Dimensions (W×H×D) | 114 × 40 × 40 cm |
| Exterior Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temperature Control Accuracy | ≤±0.5 °C |
| Temperature Uniformity | ≤±2 °C or ≤±3% |
| UV Light Source | Fluorescent UV Lamps (UVA-340 or UVB-313 typical) |
| UV Wavelength Range | 280–400 nm |
| Lamp Lifetime | ~2,000 hours |
| Exposure Time Range | 0–999 hours (adjustable) |
| Chamber Material | SUS#304 Stainless Steel (inner & outer) |
| Heating System | U-shaped Titanium Alloy Heaters |
| Safety Features | Interlocked Door Cut-off, Over-Temperature Protection, Low-Water Level Protection |
| Power Supply | AC 220 V ±5%, 50 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | OK-UV-290.1 |
| Humidity Range | ≥95% RH (actual chamber humidity) |
| UV Lamp Power | 40 W per lamp |
| Irradiance Range | 0.72 W/m² (at 340 nm reference wavelength) |
| Exposure Time | 1–9999 h (adjustable) |
| Black Panel Temperature Range | 75 °C (max) |
| UV Wavelength Range | 280–400 nm (UVA/UVB spectrum) |
| Internal Chamber Dimensions (L×W×H) | 1170 × 400 × 400 mm |
| Temperature Control Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2 °C or ≤ ±3% |
| Lamp Lifetime | ~2000 h (typical) |
| Construction Material | SUS#304 stainless steel (inner & outer chamber) |
| Heating System | U-shaped titanium alloy heating elements |
| Safety Features | Interlocked door cut-off for UV lamps, over-temperature protection, low-water-level cutoff |
| Power Supply | AC 220 ±5 V, 50 ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | OK-UV-291.2 |
| Humidity Range | ≥95% RH (in-chamber actual value) |
| Lamp Power | 40 W per tube |
| Irradiance Range | 0.72 W/m² |
| Exposure Time | 1–9999 h (adjustable) |
| Light Temperature Range | RT to 70°C |
| UV Wavelength Range | 280–400 nm |
| Chamber Dimensions (L×W×H) | 1170 × 400 × 400 mm |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Lifetime | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer mesh tray or 500-mm-diameter rotating turntable (0–3 rpm) |
| Internal Chamber Material | SUS304 stainless steel |
| External Cabinet | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB China, subject to configuration and customization) |
| Internal Dimensions (L×W×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150 °C (chamber), 40–85 °C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5 °C (temperature), ±2.0% RH (humidity) |
| Uniformity | ±2.0 °C (temp), ±3.0% RH (humidity) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h at standard irradiance setpoints |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior — SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (excl. tax & shipping) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | ≥95% RH |
| UV Spectrum | 290–400 nm (UV-A/B/C selectable) |
| Lamp Power | 40 W |
| Lamp Life | Up to 6,000 h |
| Sample-to-Lamp Distance | 50 mm |
| Lamp Spacing | 35 mm |
| Light Source | Imported Xenon Arc Lamp |
| Cooling | Patented Forced-Air Thermal Management |
| Exposure Modes | Radiant Illumination + Condensation Humidity Cycling |
| Black Panel Temperature Monitoring | Dual-Metal Thermometer |
| Control System | LED-display PID + SSR Microcomputer Controller with Programmable Timer |
| Heating | Nickel-Chromium Alloy Resistive Heater |
| Humidification | Stainless Steel Surface-Evaporation Humidifier |
| Safety Protections | Overtemperature, Leakage Current, Short Circuit, Overcurrent, Low-Water Cut-off |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–12,800 (FOB, model-dependent) |
| Internal Chamber Dimensions (L×W×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Cycle Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer wire mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB) |
| Internal Dimensions (mm) | 500×500×400 / 500×750×600 / 800×800×800 / 1000×1000×1000 |
| External Dimensions (mm) | 1000×1700×900 / 1100×1900×1000 / 1400×1900×1300 / 1650×2100×1500 |
| Temperature Range | 0–100°C (optional up to 150°C) |
| Black Panel Temperature | 40–85°C |
| Humidity Range (Light Cycle) | 20–75% RH |
| Humidity Range (Dark Cycle) | 20–98% RH |
| Temperature Uniformity | ±2.0°C |
| Temperature Stability | ±0.5°C |
| Humidity Uniformity | ±3.0% RH |
| Humidity Stability | ±2.0% RH |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6.0 kW |
| Lamp Lifetime | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer stainless steel mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Inner Chamber Material | 1.2 mm SUS304 stainless steel |
| Outer Casing | 1.5 mm galvanized steel with powder coating or optional SUS304 |
| Safety Protections | Over-temperature cutoff, high/low pressure monitoring, overload protection, oil pressure safeguard, travel limit switch, earth leakage detection |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Distributor |
| Country of Origin | Import |
| Model | OK-XD-100 |
| Price | USD 5,200 (FOB) |
| Internal Chamber Dimensions | 50 × 50 × 40 cm |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-100 |
| Xenon Lamp Power | 1.8 kW |
| Spectral Irradiance Range | 300–800 nm |
| Nominal Irradiance | 550 W/m² ±10% (broadband, 300–800 nm) |
| Light Cycle Duration | 1–999 h/min/sec (programmable) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Cooling Method | Water-cooled lamp system |
| Filter Options | Daylight, Window Glass, Extended UV |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | OK-XD-100 |
| Internal Chamber Dimensions (W×D×H) | 50×50×40 cm |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-100 |
| Price | USD 5,300 (FOB) |
| Xenon Lamp Power Options | 1.8 kW / 2.5 kW / 6 kW |
| Radiant Flux Density | ≤1200 W/m² |
| Light Exposure Cycle Range | 1 s to 999 h (programmable in seconds, minutes, or hours) |
| Humidity Range (Light Cycle) | 20–75% RH |
| Temperature Range | –10°C to 80°C |
| Black Standard Temperature (BST) Control | 40–80°C |
| Irradiance Control | 0.3–1.0 W/m² @ 340 nm (manual adjustment) |
| Sample Rack | Rotating type (standard), optional fixed or custom large-format |
| Filter Options | Daylight (D65), Window Glass (W), UV-Enhanced |
| Compliance | ISO 4892-2, ASTM G155, SAE J2527, IEC 61215, GB/T 1865 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | OK-XD-100.001 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (programmable) |
| Humidity Range | 20–75 %RH |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 5,200 (excl. tax & freight) |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| External Dimensions | 1350 × 1850 × 1550 mm (D×W×H) |
| UV-A Spectral Range | 320–380 nm |
| Irradiance Control | Adjustable up to 0.7 W/m² @ 340 nm |
| Humidity Range (Irradiation Mode) | 45–80 %RH |
| Condensation Humidity | ≥95 %RH |
| Black Panel Temperature Range | 30–60 °C (±1 °C tolerance) |
| Irradiation Temperature Range | 50–60 °C (±3 °C tolerance) |
| Condensation Temperature Range | 40–60 °C (±3 °C tolerance) |
| Temperature Resolution | 0.1 °C |
| Condensation Water Depth | ≤30 mm with Auto-Fill Controller |
| Control System | PID Self-Tuning Temperature Regulation |
| UV Radiometer | Fixed-position, high-accuracy broadband sensor |
| Cycle Programming | Dual-mode alternating irradiation/condensation cycles, programmable up to 999 hours per phase |
| Electrical Components | Schneider Electric contactors & circuit breakers |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +85 °C |
| Humidity Range | 10–98% RH |
| Temperature Uniformity | ±3 °C |
| Humidity Uniformity | ±3% RH |
| Temperature Fluctuation | ±3 °C |
| Humidity Fluctuation | ±3% RH |
| Rainfall Duration | 0–9999 min (continuous) |
| Rainfall Cycle | 0–240 min (intermittent) |
| Xenon Lamp Power | 6 kW |
| Spectral Range | 290–400 nm |
| Irradiance Control | 315 nm band (±5%) |
| Sample Rack Rotation | 1 rpm, 360° |
| Sample-to-Lamp Distance | 300–375 mm |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| Refrigerant | R404A |
| Compressor | Hermetic French Tecumseh Unit |
| Cooling Method | Air-Cooled, Single-Stage |
| Compliance | GB/T 16422.2–1999, GB/T 1865–2007, GB/T 2423.24–1995, ASTM G155, ISO 105-B02/B04, SAE J2527, SAE J2412 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Internal Dimensions (W×D×H) | 1000 × 1000 × 1000 mm |
| Sample Tray Size | 530 × 730 mm |
| Temperature Range | 40–80 °C (adjustable) |
| Humidity Range | 40–95 %RH (adjustable) |
| Black Panel Temperature | 40–100 °C ±3 °C |
| Temp. Uniformity | ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Xenon Lamp | 2 kW single-lamp configuration |
| Lamp Life | 1000 h |
| Irradiance Spectrum | 290–800 nm |
| Sample-to-Lamp Distance | 230–280 mm |
| Rain Cycle Time | 0–9999 min (continuous) |
| Intermittent Rain Interval | 0–240 min |
| Water Spray Cycle | 18 min ON / 102 min OFF or 12 min ON / 48 min OFF |
| Spray Pressure | 0.12–0.15 MPa |
| Nozzle Orifice | Ø0.8 mm |
| Heating Power | 2 kW |
| Humidification Power | 1.2 kW |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +10°C to +70°C |
| Humidity Range | ≥95% RH |
| Control Accuracy | ±0.1°C (temperature), ±1% RH (humidity) |
| Sample Capacity | 75 mm × 150 mm (standard) |
| Internal Chamber Dimensions | 1000 mm × 1000 mm × 1000 mm |
| Heating System | Independent Ni-Cr alloy resistive heaters |
| Humidification System | External stainless steel shallow-surface evaporative humidifier |
| Black Panel Temperature Sensor | Bimetallic black panel thermometer |
| Cooling Water Supply | Automated for xenon lamp cooling |
| Controller | Weilun color touchscreen HMI + Siemens S7-1200 PLC |
| Air Circulation | High-temperature-resistant low-noise centrifugal blower with multi-vane impeller |
| Chamber Construction | Exterior – electrostatically coated stainless steel |
| Safety Protections | Over-temperature cutoff, phase-loss protection |
| Compliance | Designed per ISO 4892-2, ASTM G155, IEC 60068-2-9 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Interior Dimensions | 1000 × 1000 × 1000 mm |
| Temperature Range | RT to 80°C (Models B & C) / RT to –80°C (Model A) |
| Humidity Range | 30–90% RH |
| Xenon Lamp Power | 3 kW (Horizontal) / 6 kW (Vertical) |
| Irradiance Control | (550 ± 5) W/m² (290–800 nm) |
| Filter Type | External Quartz Filter |
| Spray System | Stainless Steel Nozzles (Ø0.4 mm), Pressure 78–127 kPa, Programmable On/Off Cycle (1 min–99 h) |
| Dark Cycle | Adjustable (10 min–99 h) |
| Sample Rotation | 360°, 1 rpm (for 75 × 150 mm standard panels) |
| Controller | Touchscreen Programmable LCD Interface |
| Temperature Resolution | ±0.1°C |
| Humidity Resolution | ±1% RH |
| Timer Range | 0–99 h 99 min 99 s |
| Lamp Service Life | >1000 h |
| Compliance | GB/T 8427–1989, GB/T 8430–1998, GB/T 1865–1997, GB/T 16422.2–1999 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | OK-XD-1000.00 |
| Xenon Lamp Power | 6 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Cycle Programmability | 1–999 h/min/sec (continuous adjustable) |
| Humidity Range (Light Cycle) | 20–75 %RH |
| Compliance | ISO 4892-2, ASTM G155, GB/T 16422.2, ISO 11341, ASTM D6695 |
| Brand | OK Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | OK-XD-150 |
| Xenon Lamp Power | 3 kW |
| Irradiance Range | ≤1200 W/m² |
| Light Exposure Cycle | 1–999 h/min/sec (continuously adjustable) |
| Humidity Range (Light Cycle) | 20–75% R.H. |
| Compliance | ISO 4892-2, ASTM G155, GB/T 16422.2, SAE J2527/J2412 |