| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JH |
| Pricing | Upon Request |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | JH-NSS-8000L |
| Price Range | USD 720 – 72,000 |
| Spray Mode | Continuous Air-Atomized Spray |
| Spray Rate | 1–2 mL/(h·80 cm²) |
| Nozzle Pressure | 0.7–1.0 kgf/cm² (68.6–98.1 kPa) |
| De-misting Method | Pneumatic Air-Pressure Exhaust |
| Compliance | ISO 9227, ASTM B117, JIS Z2371, GB/T 2423.17 |
| Temperature Range | -40°C to +150°C (Cycling Mode) |
| Humidity Range | 10–98% RH (Cycling Mode) |
| Chamber Volume | 8000 L (Large-Scale Industrial Configuration) |
| Brand | Jinhoo |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | JH-PF |
| Pricing | Available Upon Request |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 85–98% RH |
| UV Wavelength Range | 280–400 nm |
| UV Light Source | UV-A and UV-B Fluorescent Lamps |
| Sample-to-Lamp Distance | 50 ± 2 mm |
| Lamp-to-Lamp Spacing | 70 ± 2 mm |
| Sample Holder Dimensions | 150 × 75 × 1.5 mm |
| Brand | Jinhoo |
|---|---|
| Model | JH-PS |
| Origin | Shanghai, China |
| Construction | SUS304 stainless steel interior and chamber walls (optional aluminized painted outer shell) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 85–98% RH |
| UV Wavelength Range | 280–400 nm (UV-A/UV-B) |
| UV Lamp Type | Fluorescent UV-A and UV-B lamps |
| Distance from Sample Surface to Lamp Center | 50 ± 2 mm |
| Lamp Spacing (center-to-center) | 70 ± 2 mm |
| Sample Holder Dimensions | 150 × 75 × 1.5 mm |
| Heating Method | Air-heated resistive elements |
| Humidification Method | Steam-based humidifier with stainless steel boiler |
| Control System | Imported programmable temperature/humidity/time controller |
| Compliance | GB/T 14522–1993, GB/T 2423.24–2013 |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-Series Explosion-Proof Battery Environmental Test Chamber |
| Temperature Range | −70 °C to +150 °C |
| Cooling Method | Dual-Compressor Refrigeration System (R23/R404A) |
| Explosion Protection | ATEX & IECEx Certified |
| Temperature Uniformity | ±2.0 °C |
| Temperature Stability | ±0.5 °C |
| Temperature Deviation | ±2.0 °C |
| Ramp-Up Time (25 °C → +150 °C) | ≤60 min |
| Ramp-Down Time (25 °C → −70 °C) | ≤45–80 min (model-dependent) |
| Chamber Dimensions | Customizable (Small / Medium / Large Internal Volumes) |
| Gas Monitoring | Real-time H₂ & CH₄ Detection with Auto-Alarm, Power Cut-off, and Forced Ventilation Interlock |
| Construction | 304 Stainless Steel with Explosion-Resistant Coating, Pressure Relief Valve, and Flame Arrestor Mesh |
| Compliance | Designed per IEC 62660-2, UN 38.3, GB/T 31467.3, ISO 12405-2, and GLP-aligned data integrity requirements |
| Brand | Jinhoo |
|---|---|
| Model | JH-SN-900 |
| Origin | Shanghai, China |
| Internal Chamber Dimensions | 950 × 950 × 850 mm (L×W×H) |
| Temperature Range | Ambient +10°C to 300°C |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Heating Rate | 1.0–3.0°C/min (ambient to 300°C, approx. 40 min) |
| Timer Range | 0–999 hours |
| Rated Power | 6 kW |
| Supply | 3-phase 4-wire 380 V AC, 50 Hz |
| Max Ambient Humidity | ≤85% RH |
| Operating Ambient Temperature | 5–35°C |
| Air Exchange System | Adjustable forced-air ventilation |
| Compliance | GB/T 3512-2001, JIS K 7212, JIS B 7757 |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-UV (UVA-340 / UVB-313 Lamp Configuration) |
| Compliance | GB/T 14522–1993, ISO 4892-3, ASTM G154, DIN 50017, JIS D 0205 |
| UV Lamps | U.S.-sourced UVA-340 & UVB-313 fluorescent tubes |
| Irradiance Control | Adjustable continuous UV output |
| Humidity Simulation | Condensation cycle via heated water reservoir |
| Water Spray System | Integrated high-pressure spray pump |
| Control Mode | Programmable cycling of UV irradiation / condensation / water spray |
| Sample Exposure Temperature Range | 40–70 °C (black panel) |
| Brand | Jinhoo |
|---|---|
| Model | JHF-800 |
| Chamber Internal Dimensions (W×D×H) | 800 × 1000 × 1000 mm |
| External Dimensions (W×D×H) | 1030 × 1120 × 1860 mm |
| Power Consumption | 1.0 kW |
| Filtration Mesh | Wire Diameter 50 µm, Pitch 75 µm |
| Dust Concentration Range | 2–4 kg/m³ |
| Timer Range | 0–99 h 59 min (for vibration & fan control) |
| Vacuum System | Equipped with pressure gauge, air filter, and pressure regulator (vacuum pump not included) |
| Heating System | Stainless-steel mica-sheathed heating elements |
| Fan Type | Enclosed alloy low-noise centrifugal blower |
| Safety Protections | Leakage protection, short-circuit protection, overtemperature protection, motor overheat protection, overcurrent protection |
| Compliance | GB/T 4208 (IP5X/IP6X), GB/T 2423.37–2006, GB/T 4706.1, GB/T 10485–2007, DIN 40050-9 |
| Sample Compatibility | Enclosures up to IP6X-rated electrical/electronic equipment, automotive lighting assemblies, connectors, consumer appliance housings, and industrial control cabinets |
| Software & Control | Imported programmable logic controller (Moeller/Knorr, Germany), integrated microcomputer-based timing and sequence control |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JST-090 |
| Chamber Dimensions (W×D×H) | 90×60×50 cm |
| Interior Material | PVC & PP |
| Test Temperature Range | 35±1°C (NSS), 50±1°C (AASS/CASS) |
| Saturated Air Tank Temperature | 47±1°C (NSS), 63±1°C (AASS/CASS) |
| Saturation Pressure | 0.8–2.0±0.01 kg/cm² |
| Fog Output | 1.0–2.0 mL/80 cm²/h |
| pH Range | 6.5–7.2 (NSS), 3.0–3.2 (AASS/CASS) |
| Chamber Volume | 270 L |
| Water Reservoir Capacity | 25 L |
| Power Supply | AC 1φ 220 V, 50 Hz, 30 A |
| Compliance | ASTM B117, ISO 9227, GB/T 2423.17, GJB 150.11A, CNS 3627/3885/4519/7669/8886 |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Domestic OEM Manufacturer |
| Product Category | Domestic |
| Model | JTH-150P |
| Pricing | Available Upon Request |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JTSE Series |
| Price Range | USD 1,400 – 14,000 (FOB Shanghai) |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −70 °C |
| Thermal Shock Range | −70 °C to +150 °C |
| Temperature Stability | ±0.5 °C (steady-state) |
| Temperature Uniformity | ±1.5 °C (at 60% load, per IEC 60068-3-5) |
| Heating Rate | ≥10 °C/min (typical, 20 °C to +150 °C) |
| Cooling Rate | ≥12 °C/min (typical, 20 °C to −70 °C) |
| Humidity Control Capability | Optional integrated humidity module (5–95% RH, dew point ≤ −75 °C at −70 °C operation) |
| Compressor System | Dual-stage hermetic scroll compressors (Emerson Copeland ZB series or Danfoss HPU series, OEM-specified) |
| Calibration | Full-range CNAS-accredited calibration available (−70 °C to +150 °C, 10–95% RH), traceable to NIM (National Institute of Metrology, China) |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | JH-SSC Series |
| Type | Benchtop Environmental Test Chamber |
| Cooling Method | Air-Cooled |
| Temperature Range | 15–45 °C |
| Humidity Range | 30–98 % RH |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±1 °C (high-temp), ±2 °C (low-temp) |
| Humidity Uniformity | ≤ ±3 % RH |
| Humidity Fluctuation | ±3 % RH |
| Heating Rate | 1.0–3.0 °C/min |
| Compliance | ASTM B117, ISO 9227 (NSS), GB/T 2423.17 |
| Application Focus | Automotive Components, Electronics Enclosures, Plated Fasteners, PCB Substrates, Aerospace Hardware |
| Brand | Jinhoo |
|---|---|
| Origin | Shanghai, China |
| Model | SH-SSC |
| Spray Method | Continuous Atomization |
| Fog Output | 1–2 mL per 80 cm² per hour |
| Nozzle Pressure | 0.7–1.0 kg/cm² |
| De-fogging Method | Air-Compression Exhaust |
| Compliance | Designed to meet IEC 60068-2-11, GB/T 2423.17, ASTM B117 (configuration-dependent) |
| Chamber Construction | PVC-coated steel frame with acid-resistant acrylic viewing window |
| Temperature Range | 35 ± 2 °C (standard neutral salt spray), optionally configurable for cyclic corrosion testing (CCT) protocols |
| Brand | Jinhuhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor & OEM Partner |
| Country of Origin | China |
| Model | JH-2026 High-Low Temperature Environmental Test Chamber |
| Price Range | USD 750 – 7,200 (FOB Shanghai) |
| Temperature Range | −70 °C to +150 °C |
| Refrigeration Method | Dual-stage Compressor Cooling |
| Explosion-Proof Configuration | Available (IEC 60079-0 / GB 3836.1 Certified) |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Uniformity | ≤2.0 °C (at steady state) |
| Temperature Deviation | ±2.0 °C (vs. setpoint, per IEC 60068-3-5) |
| Heating Rate | ≤60 min (−70 °C → +150 °C, empty chamber) |
| Cooling Rate | ≤45 min (25 °C → −40 °C), ≤60 min (25 °C → −70 °C), ≤80 min (25 °C → −70 °C with full thermal load) |
| Interior Dimensions | Custom-engineered (standard range: W300–2000 mm × D300–1500 mm × H300–1800 mm) |
| Brand | Jinhuhu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Product Category | Domestic |
| Model | JH-Series Polyimide (PI) High-Temperature Vacuum Curing Oven |
| Temperature Range | 150 °C to 450 °C |
| Temperature Uniformity | ±1.0 °C (at 450 °C, 32-point measurement) |
| Temperature Stability | ±0.2 °C to ±0.5 °C |
| Temperature Deviation | ≤±2.0 °C |
| Heating Rate | Up to 20 °C/min |
| Cooling Rate | From 150 °C to −40 °C in ≤45 min |
| Oxygen Concentration Control | ≤5 ppm (real-time laser O₂ sensing + N₂ purge) |
| Vacuum Level | 5×10⁻⁴ Pa (turbomolecular + roots pump system) |
| Chamber Volume | Customizable (from 30 L to >5 m³) |
| Compliance | SEMI S2/S8, ISO 9001, AS9100D, GB/T 2423.2 |
| Brand | Jiubin |
|---|---|
| Model | BJ-220 |
| Temperature Range | −70 °C to 150 °C |
| Humidity Range | 20–98 %RH |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±3–5 %RH |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.5 %RH |
| Internal Dimensions (W×H×D) | 400–1000 mm × 500–1000 mm × 400–1000 mm |
| Power Supply | 220 V / 380 V, 50 Hz |
| Compliance | GB/T 10592–1989, ANSI/EIA-364-105–1999 |
| Brand | Jiubin |
|---|---|
| Model | BJ-236 |
| Type | Oscillating Disk Curemeter (ODR) / Rotorless Curemeter |
| Temperature Range | 100–200 °C |
| Heating Rate | <10 min to setpoint |
| Oscillation Frequency | 1.7 Hz (100 rpm) |
| Oscillation Angle | ±0.5° |
| Rotor Diameter (rotor-type) | 35.55 ±0.07 mm |
| Torque Range | 0–30 N·m |
| Torque Resolution | 0.01 N·m |
| Power Supply | 220 V AC |
| Pneumatic Pressure | 0.5 MPa |
| Data Output | Date, Time, Temperature, Lab ID, Cure Curve, Temperature Profile, ML, MH, t₉₀, ts₁, tc₅₀ |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-1000 |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D × W × H) |
| Test Dust | Dry Talcum Powder |
| Dust Concentration | 2 kg/m³ |
| Airflow Velocity | 2 m/s |
| Temperature Range | Ambient to +60 °C |
| Sieve Specification | Nominal Wire Diameter 50 µm, Nominal Mesh Spacing 75 µm |
| Heating System | Integrated Resistive Heater |
| Control System | Fuji Electric PID Controller (0.2-class accuracy), Moeller Programmable Timer for Dust Cycling & Vibration Timing |
| Chamber Construction | Exterior – 1.5 mm A3 Steel with Epoxy Powder Coating |
| Viewing Window | Tempered Glass with Manual Wiper |
| Sealing | Imported EPDM Gasket |
| Internal Power Outlet | IP54-rated Dust-Protected Socket |
| Adjustable Shelving | 2-tier, Height-Adjustable Stainless Steel Racks |
| Dust Distribution Mechanism | Centrifugal Blower + Eccentric Vibrator-Assisted Bottom Feed |
| Compliance | Designed in accordance with IEC 60529 (IP5X/IP6X), MIL-STD-810H Method 510.7, GB/T 2423.37–2008 |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-CY |
| Ozone Concentration Range | 20–1000 pphm |
| Temperature Range | RT+5°C to 70°C |
| Temperature Uniformity | ≤2°C |
| Temperature Fluctuation | ≤±0.5°C |
| Gas Flow Velocity | 12–16 mm/s |
| Sample Rack Traverse Speed | 0–50 mm/s |
| Dynamic Stretching Frequency | 0.5 Hz |
| Test Gas Flow Rate | 0–60 L/min |
| Safety Compliance | Overload, short-circuit, ground-fault, over-temperature, and motor overload protection |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-GDWJB |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 40–95 % RH |
| Interior Dimensions (W×D×H) | 350×320×450 mm to 700×800×890 mm (multiple variants) |
| Temperature Uniformity | ±0.5 °C |
| Sensor Type | PT100 Platinum Resistance Thermometer |
| Construction | Exterior – Phosphated & Powder-Coated Steel |
| Insulation | Ultra-Fine Glass Fiber |
| Compressor | Original Tecumseh (France) Hermetic Compressor |
| Controller | Microprocessor-Based PID Temperature Controller with Dual Digital Display (Set/Actual) |
| Air Circulation | Low-Noise German Imported Blower with Optimized Duct Design |
| Safety Protections | Compressor Overheat, Fan Overheat, High-Pressure Cut-off, Phase Loss, Overload, Overtemperature, Low-Water Interlock |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.3–1993, GB/T 2423.4–1993, GB 10592–1989 |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-GDWJBSR |
| Temperature Range | −20 °C to +100 °C |
| Humidity Range | 40–95 % RH |
| Temperature Uniformity | ±0.5 °C |
| Internal Chamber Material | SUS304 Mirror-Finish Stainless Steel |
| Insulation | High-Density Ultra-Fine Glass Fiber |
| Control System | Microprocessor-Based PID Controller with Dual Digital Display (Set/Actual) |
| Compressor | Original Tecumseh (France) Hermetic Scroll Compressor |
| Air Circulation | Low-Noise German Imported Axial Fan + Optimized Air Duct Design |
| Standard Test Port | Ø30 mm on Left Side Wall |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.3–1993, GB/T 2423.4–1993, GB 10592–1989 |
| Safety Protections | Compressor Overheat, Fan Overheat, High-Pressure Cut-off, Phase Loss Detection, Overload Protection, Overtemperature Alarm, Low-Water Level Interlock |
| Power Supply | 380 V AC, 50 Hz |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-GDWSR |
| Pricing | Available Upon Request |
| Internal Dimensions (L×W×H) | 350×320×450 mm / 400×500×500 mm / 600×550×750 mm / 700×800×890 mm |
| Temperature Range | −65 °C to +100 °C (Cascaded Refrigeration System) |
| Humidity Range | 40–95 % RH |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Temperature Uniformity | ±0.5 °C |
| Outer Casing | Phosphated and Powder-Coated Steel |
| Inner Chamber | Mirror-Finish SUS304 Stainless Steel |
| Insulation | High-Density Ultra-Fine Glass Fiber |
| Power Supply | 380 V, 50 Hz |
| Safety Protections | Compressor Overheat, Fan Overheat, High-Pressure Cut-off, Phase Loss, Overload, Overtemperature, Low-Water Level |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-GW |
| Price Range | USD 700 – 1,400 (FOB) |
| Max Operating Temperature | 200 °C to 300 °C |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Heating Rate Options | 3, 5, or 10 °C/min |
| Construction | Cold-rolled steel outer shell (1.5 mm), 304 stainless steel inner chamber (1.2 mm), high-efficiency glass fiber insulation |
| Compliance | GB 11158–1989, GB/T 2423.2–2008 (IEC 60068-2-2) |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-HWHS |
| Chamber Type | Vertical |
| Temperature Control Range | 10–50 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Control Range | 40–95 %RH |
| Humidity Uniformity | ±5 %RH |
| Power Consumption | 1400–2250 W |
| Inner Chamber Dimensions (mm) | 400×400×500 to 600×650×1000 |
| Refrigeration System | Original Tecumseh (France) hermetic compressor with high/low pressure protection and delayed start logic |
| Interior Material | Mirror-finish stainless steel with adjustable shelving |
| Door Design | Dual-door structure with tempered glass inner door |
| Humidity Generation | High-precision, high-capacity steam-based humidifier |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-MF1000 |
| Temperature Range | Ambient to 1000 °C |
| Control Accuracy | ±1 °C (typical at steady state) |
| Heating Element | Kanthal A1 alloy wire |
| Chamber Volume | 12 L (standard configuration) |
| Power Supply | 220 V AC, 50/60 Hz |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB-P |
| Price Range | USD 7,000 – 14,000 |
| Internal Chamber Dimensions (D×W×H) | 450 × 1170 × 500 mm |
| External Dimensions (D×W×H) | 500 × 1380 × 1480 mm |
| Temperature Range | RT+10°C to 70°C |
| Temperature Uniformity | ±3°C |
| Temperature Fluctuation | ±1°C |
| Humidity Level | ≥95% RH |
| UV Lamp Center-to-Center Spacing | 70 mm |
| Sample-to-Lamp Distance | 50 ± 2 mm |
| UV Lamp Types | UVA-340 or UVB-313 |
| Spectral Range | 315–400 nm (UVA), 280–315 nm (UVB) |
| Sample Holder Size | 80 × 300 mm |
| Total Power Consumption | 3.5 kW |
| Supply Voltage | AC 380 V, 50 Hz |
| UV Lamp Quantity | 8 × 40 W |
| Lamp Lifetime | 5000 h |
| Water Consumption | 8 L/day |
| Brand | Jiubin Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | JB-R162 |
| Internal Chamber Dimensions | 400 × 400 × 500 mm (D×W×H) |
| External Dimensions | 870 × 950 × 1750 mm (D×W×H) |
| Temperature Range | +10°C to +90°C |
| Temp. Uniformity | ±2°C |
| Temp. Stability | ±0.5°C |
| Black Panel Temperature Range | 50°C to 90°C |
| Humidity Range | 45–98% RH |
| Humidity Uniformity | ±5% RH |
| Humidity Stability | ±2% RH |
| Irradiance Spectrum | 290–800 nm |
| Irradiance Setpoint | 550 W/m² |
| Xenon Lamp Configuration | 3 × 2.5 kW (adjustable, total 7.5 kW) |
| Lamp Life | ~1600 h |
| Sample-to-Lamp Distance | 350–375 mm |
| Sample Tray Size | 400 × 700 mm |
| Rain Cycle | 0–240 min adjustable |
| Continuous Rain Duration | 0–9999 min |
| Water Spray Pattern | 18 min on / 102 min off |
| Water Pressure | 1.0–1.5 bar |
| Acoustic Noise Level | ≤80 dB(A) at 1 m |
| Timer Range | 0–999 h (setpoint), 0–99 h (programmable cycling) |
| Heating Power | 1 kW |
| Humidification Power | 1 kW |
| Safety Protections | Leakage current protection, overcurrent cutoff, overtemperature cutoff, audible alarm, low-water & ground-fault detection, power-loss memory function |
| Brand | Jiubin |
|---|---|
| Model | JB |
| Origin | Shanghai, China |
| Type | Domestic |
| Temperature Range | -70°C to +180°C |
| Humidity Range | 20–95% RH |
| Temperature Change Rate | ≥2°C/min (from -55°C to +85°C, loaded, average) |
| Temperature Uniformity (unloaded) | ≤2°C |
| Temperature Fluctuation (unloaded) | ≤±0.5°C (ambient to +85°C), ≤±1°C (≤-40°C) |
| Temperature Deviation (unloaded) | ≤±2°C |
| Humidity Accuracy | ±3% RH (>75% RH), ±5% RH (≤75% RH) |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (D×W×H) |
| Effective Volume | 1 m³ |
| Load Capacity | 60 kg |
| Heat Load Capacity | 1000 W |
| Cooling Method | Water-Cooled Mechanical Compression Refrigeration |
| Humidification Method | Steam Humidification |
| Vibration Interface | Integrated electrodynamic shaker coupling (standard 50 mm stroke, 1000 kgf peak force, frequency range 5–2000 Hz — compatible with external vibration controllers per ISO 10816 & ASTM D4728) |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JB |
| Pricing | Available Upon Request |
| Vacuum Range | 1.0 × 10⁵ Pa to 1.0 × 10⁻¹ Pa |
| Pump Type | Rotary Vane Mechanical Vacuum Pump |
| Nominal Pumping Speed | 30 L/s |
| Ultimate Vacuum | ≤ 1.0 × 10⁻¹ Pa |
| Door Seal | Fluoroelastomer (FKM) O-ring with Flanged Clamp Closure |
| Electrical Protection | Phase Sequence Protector & Power Failure Safety Interlock |
| Interface | Dual Standard Aviation Connectors (MIL-DTL-38999 Series) |
| Compliance | Designed per IEC 60068-2-26, GB/T 2423.21, and ASTM E595 outgassing pre-screening guidelines |
| Brand | Jiubin |
|---|---|
| Origin | Shanghai, China |
| Model | JB-106D |
| Chamber Construction | Full PVC Body with Structural Reinforcement |
| Spray System | Dual-Mode (Continuous & Programmable) |
| Nozzle Type | Precision Borosilicate Glass Nozzle (≥4000 hr crystallization-free operation) |
| Temperature Control | Digital PID Controller with Platinum RTD Sensor (±0.3 °C accuracy) |
| Humidity Generation | Saturated Steam Heating + Henry’s Law–Based Pressure Tank Humidification |
| Safety Protection | Dual Over-Temperature Cut-off + Low-Water Level Alarm |
| Compliance | GB/T 2423.17 (Neutral Salt Spray), GB/T 2423.18 (Acetic Acid Salt Spray) |
| Display & Interface | Integrated Front-Panel Control Module with Real-Time Parameter Monitoring |