Environmental Test Chamber
Filter
Showing 1831–1860 of 2009 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with Imported German Semi-Hermetic Compressors |
| Cooling Water Requirement | External 10 m³/h Cooling Tower (User-Supplied) |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.22–2002, GJB 150.5–2009, IEC 60068-2-14, MIL-STD-810G Method 503.5, QC/T 17–1992, EIA-364-32 |
| Brand | OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | TEMI880 Color Touchscreen Programmable Controller (English/Chinese Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Protection Features | Compressor Overheat/Overcurrent/High-Pressure Protection |
| Standard Equipment | Dual-Layer Tempered Glass Viewing Window |
| Temperature/Humidity Control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating Ambient | +5°C to +35°C |
| Heater | Nickel-Chromium Alloy Wire |
| Humidifier | Surface Evaporation Type |
| Blower | Centrifugal Fan |
| Airflow Pattern | Wide-Band Forced Circulation (Top-Out/Bottom-In) |
| Condensation Method | Air-Cooled |
| Refrigeration System | Hermetic “Tecumseh” (France) Compressor |
| Construction | Outer Shell: SUS304B Stainless Steel |
| Inner Chamber | Welded Austenitic Stainless Steel (Leak-Proof Seam Welding) |
| Sealing | Dual-Silicone Rubber Gasket at Door |
| Insulation | High-Density Mineral Wool (Low Thermal Conductivity) |
| Internal Fans | Axial-Flow Circulation Fans (Quantity Configured per Chamber Volume) |
| Cable Port | One φ50 mm Penetration Port (Left Wall) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 13,500 (FOB) |
| High-Temp Zone Range | 70–150 °C |
| Low-Temp Zone Range | –10 to –45 °C |
| Temperature Resolution | 0.1 °C |
| Control Accuracy | ±2 °C |
| Heating Time (RT → 150 °C) | ~35 min |
| Cooling Time (RT → –45 °C) | ~40 min |
| Transfer Time Between Zones | 10–20 s |
| Test Chamber Recovery Time | 5–15 min |
| Hot/Cold Bath Dimensions | 30 × 30 × 15 cm (D×W×H) |
| External Dimensions | 200 × 160 × 190 cm (D×W×H) |
| Construction Material | SUS#304 Stainless Steel |
| Insulation | Polyurethane Foam + High-Density Fiberglass |
| Refrigerant | R404A/R23 Dual-Circuit System |
| Controller | U-8226S Touchscreen PID Microprocessor |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (FOB) |
| Temperature Range | –70°C to +180°C |
| Humidity Range | 5% to 98% RH |
| Minimum Achievable Humidity | ≤5% RH (at 25°C) |
| Control Accuracy | ±0.5°C / ±2% RH |
| Uniformity | ±1.5°C / ±3% RH |
| Cooling Water Requirement | 10–28°C, 0.1–0.3 MPa |
| Power Supply | 380 VAC, 3-phase, 50/60 Hz |
| Compliance | GB/T 2423.1–2023, GB/T 2423.2–2023, IEC 60068-2-1, IEC 60068-2-2, GJB 1032A–2012, MIL-STD-2164A, USP <1151> (Environmental Stress Screening Guidance) |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (Reference Only) |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,100 (Reference Only) |
| Temperature Range | –70°C to +150°C |
| Humidity Range | 20–98% RH |
| Compliance | GB/T 5170.2–1996, GB/T 5170.5–1996, GB 2423.1–1989, GB 2423.2–1989, GB 2423.22–1987, GB 10589–1989, GB 10592–1989, GB 11158–1989 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,100 (approx. ¥22,000) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | +5°C to 60°C |
| Internal Chamber Dimensions | W120 × H50 × D100 cm |
| Temperature Uniformity | ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Salt Spray Deposition Rate | 1–2 mL / 80 cm²·h |
| Spray Mode | Continuous or Cyclic |
| Chamber Material | High-Purity Grey PVC (Acid- and Alkali-Resistant) |
| Heating System | Independent Ni-Cr Alloy Heaters |
| Temperature Sensor | PT100 Platinum Resistance Thermometer |
| Control System | LED Digital PID Controller with Dual-Channel Display |
| Safety Features | Circuit Breakers, Dual Overheat Protection (Electronic & Mechanical), Integrated Water Filtration, Preheated Salt Solution System |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Capacity Options | 1000 kg / 2000 kg / 5000 kg |
| Test Area | 1200 × 1200 mm (customizable) |
| Resolution | 1/10,000 |
| Display Units | kg, N, lbf |
| Test Speed | 10 ± 3 mm/min |
| Overall Dimensions | 1200 × 1000 × 1400 mm |
| Approx. Weight | 750 kg |
| Power Supply | 220 V AC, 50 Hz |
| Load Cell | High-precision explosion-proof load cell (US-sourced) |
| Drive System | Taiwan-made AC frequency-controlled motor |
| Motion Mechanism | Precision ball screw actuation |
| Control System | Microprocessor-based controller with real-time compression monitoring and automatic crush detection |
| Brand | OEM / Custom Brand Available |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Internal Chamber Dimensions (W×D×H) | 900 × 600 × 500 mm |
| Test Temperature Range | 35–50 °C (chamber), 47–63 °C (saturated air tank) |
| Control Accuracy | ±0.1 °C (PID digital temperature controller) |
| Spray Nozzle Material | Borosilicate Glass (Pyrex®) |
| Heating System | Titanium-sheathed Infrared Heating Elements with Water-Jacketed Chamber Design |
| Compliance Standards | GB/T 2423.17 (Ka), GB/T 10587, GJB 150.11A, DIN 50021, ASTM B117, ISO 9227 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Operational Control) |
| Humidity Control | Simulated Dew via Condensation |
| Spray Function | Optional Water Spray Nozzle Assembly |
| Compliance | Designed to meet ASTM G154, ISO 4892-3, and SAE J2020 test protocols |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (Reference Only) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,200 (FOB) |
| Internal Chamber Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temperature Control Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2 °C or ≤ ±3% |
| UV Lamp Type | Fluorescent UV Lamps (UVA-340 or UVB-313 equivalent) |
| UV Wavelength Range | 280–400 nm |
| Lamp Service Life | Approx. 2,000 hours |
| Exposure Time Setting Range | 0–999 h |
| Chamber Material | SUS#304 Stainless Steel (Interior & Exterior) |
| Heating System | U-shaped Titanium Alloy High-Speed Heating Elements |
| Safety Features | Interlocked UV lamp cutoff upon door opening, Overtemperature Protection, Low-Water Level Cut-off |
| Power Supply | AC 220 ±5 V, 50 ±0.5 Hz |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (operational test range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH during irradiation |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ±8 W/m² |
| UV Uniformity | ≥90 % across sample plane |
| Key Specifications | Temperature Range: RT to 85 °C (Operating Range: 50 ±10 °C) |
|---|---|
| Heating Rate | ≤25 min (RT → 85 °C) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Output | 295–450 nm |
| Irradiance | 200 ±8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90 % |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 2,500–3,200 (FOB) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40–70 °C (controllable) |
| Humidity Control | Condensation cycle only (no active RH control) |
| Sample Capacity | Standard 48-position rack (75 mm × 150 mm specimens) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Black Panel Thermometer, Programmable Controller (LCD + USB data logging) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Ramp-up Time (RT → 85 °C) | ≤25 min |
| Light Source | 1 × 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90 % |
| UV Sensor | Spectral Radiometric Transmitter (developed by No. 622 Institute) |
| Filter | Custom High-Borosilicate Glass (IR-blocking, ~30 % IR attenuation) |
| Black Panel Temperature (BPT) | 40–85 °C |
| Test Modes | UV Irradiation, Condensation, Water Spray, and Programmable Cycling |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Cooling | Integrated Forced-Air Internal Circulation System |
| Irradiance Integration | LCD-based Real-Time Accumulated Dose Calculator |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| Light Source | UVA-340 or UVB-313 Fluorescent Lamps |
| Cycle Modes | UV Irradiation + Condensation / UV + Spray |
| Temperature Range | 40–70°C (UV), 40–60°C (Condensation) |
| Humidity Control | 90–100% RH during Condensation Phase |
| Sample Capacity | Standard 48-position rack (75 × 150 mm specimens) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Black Panel Thermometer, Irradiance Monitoring Sensor |
| [Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only)] |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 Fluorescent Lamps |
| Temperature Range | 40–70°C (Irradiation), 30–60°C (Condensation) |
| Humidity Control | Condensation Cycle via Water Reservoir |
| Sample Capacity | Standard 3–5 Specimen Holders (75 × 150 mm) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Irradiance Monitoring Sensor, Programmable Cycling Controller |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40–70°C (Controlled) |
| Humidity Control | Condensation Cycle (Non-saturated) |
| Irradiance Control | Yes (Optional) |
| Spray Function | Integrated Water Spray System |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40°C to 80°C (operational control) |
| Humidity Control | Condensation Cycle (50–95% RH) |
| Irradiance Control | Digital Radiometer with Feedback Loop |
| Sample Capacity | Standard 48-position rack (75 mm × 150 mm specimen area) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Optional Features | Water Spray System, Black Panel Thermometer, Programmable Cycle Sequencing |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Light Source | UVA-340 or UVB-313 Fluorescent Lamps |
| Temperature Range | 40°C to 80°C (Irradiance-Controlled) |
| Humidity Control | Condensation Cycle (50–95% RH) |
| Spray Function | Optional Deionized Water Spray |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Irradiation), 40–60 °C (Condensation) |
| Humidity Control | 90–100% RH during Condensation Cycle |
| Cycling Modes | UV Irradiation / Condensation / Optional Water Spray |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Safety Features | UV Interlock Door Switch, Over-Temp Protection, Emergency Stop, Ocular UV Shielding |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 2,600 (excl. tax & freight) |