| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5 yr service life |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key Features | Stainless steel sealed test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C |
| Humidity range | 30–65 %RH |
| Temp. uniformity | ±0.5 °C |
| Sample rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotational (1 rpm), Static or Dynamic Mode Optional |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output/Interface | 4–20 mA analog output, RS232 communication port |
| Safety Protection | Leakage current, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Specifications | Brand: OEM / Industrial Grade |
|---|---|
| Origin | Imported |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous) |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety | Fully Enclosed Ozone Loop, Leakage Protection, Over-Temp/Over-Current/Motor Thermal Cut-off |
| Interface | 4–20 mA analog output, RS232 communication port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| ASTM D1149 / ISO 1431-1 | 2004 / GB/T 7762–2003 compliant design |
| Gas flow velocity | 8–16 mm/s |
| Key | Brand: OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB ex-works |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm (parts per hundred million) |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Sample Motion | Static or Dynamic (360° rotation at 1 rpm, cycloidal trajectory compliant) |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leak-proof closed-loop ozone circulation, over-temperature, over-current, motor thermal, and short-circuit protection |
| Interface | RS232 communication port, 4–20 mA analog output, metrology calibration port |
| Key Specifications | Temperature Range: 25–40 °C |
|---|---|
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube type |
| Ozone Detection | Non-dispersive UV absorption sensor (≥5-year service life) |
| Compliance | ASTM D1149, ISO 1431-1, GB/T 7762, JIS K 6259 |
| Key Features | Stainless steel test chamber |
|---|---|
| Humidity control | 30–65% RH |
| Rotating sample rack | 1 rpm, 360° continuous rotation |
| Gas flow velocity | 8–16 mm/s |
| Compliant with GB/T 7762-2003, GB/T 2951.21-2008, GB/T 11206-2009, ISO 1431-1 | 2004 |
| Electrical supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel test chamber |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, ±0.5 °C stability |
| Humidity range | 30–65 % RH |
| Sample rack rotation | 360°, 1 rpm |
| Gas flow velocity | 8–16 mm/s |
| Compliance with GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1 | 2004 |
| Brand | OK |
|---|---|
| Model | OK-CY Series |
| Type | Environmental Test Chamber |
| Application | Ozone Resistance Testing of Polymers and Rubber |
| Temperature Range | 25–80 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + 7″ Color Touchscreen HMI |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° Rotating (1 rpm), Static/Dynamic Configurable |
| Gas Flow Velocity | 8–16 mm/s |
| Safety Protections | Leakage, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Compliance | GB/T 7762, ISO 1431-1, ASTM D1149, JIS K 6259 |
| Brand | OEM / Custom Brand |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek color touchscreen HMI |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Non-dispersive UV absorption analyzer (≥5-year service life) |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation Speed | 1 rpm (360° continuous rotation) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen HMI |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Safety Features | Leakage/short-circuit/overheat/motor-overcurrent protection |
| Interface | 4–20 mA analog output, RS232 communication port |
| Calibration Port | Integrated metrology interface |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Ozone Sensor | Non-dispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,200 (FOB Shanghai, ex-works reference only) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Sample Rotation | 360° motorized turntable, 1 rpm (static/dynamic test modes optional) |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Communication Interface | RS232, 4–20 mA analog output |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Generation | Silent discharge tube |
| Ozone Detection | Nondispersive UV absorption sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Control Accuracy | ±10 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 years) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens PLC |
| Ozone Sensor | Nondispersive UV absorption type, ≥5-year service life |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 4,950 (FOB) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Nondispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Safety Protections | Leakage, Short-Circuit, Overtemperature, Motor Overheat, Overcurrent |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temp. Uniformity | ±0.5 °C |
| Sample Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens S7-1200 PLC |
| Output Interface | 4–20 mA analog, RS232 serial |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr lifespan) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 6,200 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Non-Dispersive UV Sensor (≥5 yr lifespan) |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Temperature Stability | ±0.5 °C |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Chamber Volume | 80 L / 225 L / 500 L / 1000 L |
| Internal Dimensions (W×H×D, cm) | 40×50×40 |
| External Dimensions (W×H×D, cm) | 100×170×90 |
| Temperature Range | 25–40 °C |
| Temp. Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Monitoring | Imported UV Absorption Analyzer with 4–20 mA Output & RS232 Interface |
| Sample Rack | Motor-Driven, 360° Continuous Rotation (1 rpm), Cycloidal Trajectory Compliance |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weintek Color Touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage Current, Short-Circuit, Over-Temperature, Motor Overheat, Over-Current |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz |
| Key Features | Stainless steel ozone test chamber with fully enclosed silent-discharge ozone generation circuit |
|---|---|
| Ozone concentration range | 50–1500 ppm (pphm) |
| Temperature range | 25–40 °C, fluctuation ±0.5 °C |
| Humidity range | 30–65 % RH |
| Sample rack | 360° continuous rotation at 1 rpm (static/dynamic modes optional) |
| Gas flow velocity | 8–16 mm/s |
| Control system | Weilun color touchscreen + Siemens PLC |
| Ozone sensing | Non-dispersive UV absorption analyzer (≥5 yr service life) |
| Output | 4–20 mA analog + RS232 digital interface |
| Safety | Leakage, short-circuit, overtemperature, motor overheat, and overcurrent protection |
| Power supply | AC 380 ±5 V / 50 ±0.5 Hz |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Ozone Concentration Range | 50–1500 ppm (pphm) |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Temp. Uniformity | ±0.5 °C |
| Sample Mounting | Dynamic (360° rotation at 1 rpm) & Static options |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Siemens PLC + Weintek Color Touchscreen |
| Ozone Detection | Non-dispersive UV Sensor (≥5 yr lifespan) |
| Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Ozone Concentration Range | 50–1500 ppmv (pphm) |
| Temperature Range | 25–40 °C |
| Temperature Uniformity | ±0.5 °C |
| Humidity Range | 30–65 % RH |
| Sample Rack Rotation | 360° continuous, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation Method | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (≥5 yr service life) |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Compliance Standards | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 6,300 (FOB) |
| Standards Compliance | GB/T 7762–2003, GB/T 2951.21–2008, GB/T 11206–2009, ISO 1431-1:2004 |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 %RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temp. Uniformity | ±0.5 °C |
| Ozone Generation | Silent Discharge Tube |
| Ozone Detection | Non-Dispersive UV Absorption Analyzer (Lifespan ≥5 yr) |
| Sample Rotation | 360° motorized rack, 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Control System | Weilun color touchscreen + Siemens S7-1200 PLC |
| Safety Protections | Leakage, short-circuit, over-temperature, motor overheat, over-current |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Chamber Volume Options | 80 L / 225 L / 500 L / 1000 L |
| Temperature Range | 25–40 °C |
| Humidity Range | 30–65 % RH |
| Ozone Concentration Range | 50–1500 pphm |
| Temperature Uniformity | ±0.5 °C |
| Sample Rack | 360° continuous rotation at 1 rpm |
| Gas Flow Velocity | 8–16 mm/s |
| Ozone Generation | Silent Discharge Tube |
| Detection Method | Non-Dispersive UV Absorption |
| Sensor Lifetime | ≥5 years |
| Control System | Weilun Color Touchscreen + Siemens PLC |
| Output Interface | 4–20 mA analog output, RS232 serial communication |
| Safety Protections | Leakage current, short-circuit, overtemperature, motor overheat, overcurrent |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MDF-382E(CN) |
| Price Range | USD 14,000–28,000 |
| Temperature Range | −50 °C to −86 °C (adjustable in 1 °C increments |
| Effective Volume | 330 L |
| External Dimensions (W×D×H) | 750 × 875 × 1850 mm |
| Internal Dimensions (W×D×H) | 490 × 600 × 1140 mm |
| Net Weight | 255 kg |
| Rated Power Input | 680 W (220 V, 50 Hz) |
| Exterior Material | Electrogalvanized Steel with Polyester Powder Coating |
| Interior Material | Electrogalvanized Steel with Polyester Powder Coating |
| Door Configuration | Single External Door + Dual Internal Doors |
| Compressor | Hermetic Two-Stage Cascade System (High-Temp Stage: 450 W |
| Low-Temp Stage | 750 W) |
| Refrigerants | R404A / R508B (ODP = 0, GWP-compliant alternatives available per regional regulation) |
| Safety Systems | Dual-Threshold Temperature Alarm (High/Low), Power Failure Alert, Remote Alarm Contact Output, Sensor Self-Diagnostic Function, Compressor Overload & Thermal Protection |
| Standard Accessories | One Set of Keys, Three Stainless-Steel Adjustable Shelves, Defrosting Scraper |
| Port Configuration | Three Ø17 mm Access Ports (rear, lower-left, lower-right) |
| Brand | Panasonic |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | MDF-C630 |
| Price Range | USD 14,000–28,000 |
| Temperature Range | -20°C to -30°C (ambient 5–30°C) |
| Effective Volume | 635 L |
| External Dimensions (W×D×H) | 1800 × 800 × 848 mm |
| Internal Dimensions (W×D×H) | 1674 × 620 × 663 mm |
| Net Weight | ~105 kg |
| Rated Power Consumption | 365 W (220 V, 50 Hz) |
| Exterior Material | Electro-galvanized Steel with Polyester Powder Coating |
| Interior Material | Embossed Aluminum Sheet |
| Door Configuration | Top-opening, Single Door with Mechanical Lock |
| Measurement Port | Yes |
| Compressor | Hermetic Scroll Type |
| Refrigerant | R404A (ODP = 0, GWP = 3922) |
| Safety Features | Adjustable High/Low Temperature Alarm, Condenser Overheat Protection, Independent Power Switch |
| Standard Accessories | 1 Interior LED Lamp, 1 Defrost Scraper, 1 Set of Keys |
| Energy Efficiency | Enhanced Insulation via High-Density Polyurethane Foam (≥120 mm Thickness) |