Environmental Test Chamber
Filter
Showing 2671–2700 of 3663 results
| Key | Temperature Range: −40 °C to +150 °C (optional down to −120 °C) |
|---|---|
| Humidity Range | 30–98% RH (optional 5–98% RH) |
| Temp. Resolution | 0.01 °C |
| Humidity Resolution | 0.1% RH |
| Temp. Uniformity | ±2 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Uniformity | ±2.5% RH |
| Heating Rate | 2.0–3.0 °C/min |
| Cooling Rate | 0.7–1.0 °C/min |
| Controller | TEMI880 color LCD touchscreen programmable system |
| Power Supply | 380 V ±5%, 50 Hz, 3P+N+G (220 V optional) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or A3 steel with electrostatic powder coating |
| [Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,800 (approx.) |
| Compliance | GB10589-89, GB10592-89, GB11158-89, GB/T5170.2-1996, GB/T5170.5-1996, GB2423.1-89, GB2423.2-89, GB2423.22-87, GB2424.1-89 |
| Operating Ambient | 25°C ±6°C, Unloaded |
| Cooling Water Supply | 10–28°C, 0.1–0.3 MPa |
| Temperature Range | −70°C to +150°C (configurable) |
| Humidity Range | 20–98% RH |
| Ramp Rate | Air-average, not product-specific, dependent on load and configuration] |
| Brand | OK |
|---|---|
| Model Range | OK-TH-80 / OK-TH-150 / OK-TH-225 / OK-TH-408 / OK-TH-800 / OK-TH-1000 |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Temperature Range | -70 °C to +150 °C (configurable in four standard spans: A: 0–150 °C |
| B | -20–150 °C |
| C | -40–150 °C |
| D | -70–150 °C) |
| Humidity Range | 20–98 %RH (optional extension to 5–98 %RH or 10–98 %RH) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Stability | ±2 °C |
| Humidity Stability | +2 to +3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Heating Rate | ~4.0 °C/min |
| Cooling Rate | ~1.0 °C/min |
| Refrigeration System | Hermetically sealed, low-noise dual-stage compressor with eco-friendly refrigerants (R404A/R23) |
| Controller | LCD touch-screen interface with bilingual (English/Chinese) operation |
| Construction Material | SUS#304 stainless steel interior and exterior |
| Standard Accessories | One 50 mm diameter cable port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m power cord |
| Compliance | MIL-STD-810G (GJB150.3 & GJB150.4), IEC 60068-2-1 (Cold), IEC 60068-2-2 (Dry Heat), IEC 60068-2-78 (Steady-State Damp Heat), IEC 60068-2-30 (Cyclic Damp Heat), GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.4–1993 |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 7,200 (FOB) |
| Internal Dimensions (W×H×D, cm) | 40×50×40 to 100×100×100 |
| External Dimensions (W×H×D, cm) | 100×165×100 to 180×200×180 |
| Temperature Range | -70 °C to +150 °C (configurable models: A: 0–150 °C |
| B | -20–150 °C |
| C | -40–150 °C |
| D | -70–150 °C) |
| Humidity Range | 20–98 %RH (optional: 5–98 %RH) |
| Temperature Ramp Rate | ≤4.0 °C/min (heating), ≤1.0 °C/min (cooling) |
| Temperature Uniformity | ±0.5 °C |
| Humidity Uniformity | ±2.5 %RH |
| Temperature Fluctuation | ±2.0 °C |
| Humidity Fluctuation | +2–3 %RH |
| Resolution | 0.1 °C / 0.1 %RH |
| Controller | 7-inch color TFT touchscreen, bilingual (English/Chinese) |
| Refrigeration System | Hermetic dual-stage cascade compressor (R404A/R23) |
| Construction | Interior & exterior SUS#304 stainless steel |
| Viewing Window | Multi-layer tempered glass with embedded conductive film |
| Test Port | One Ø50 mm port on left side |
| Accessories | Two adjustable stainless steel shelves, four casters + four leveling feet |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Key | Internal Dimensions: 400 × 400 × 500 mm (L×W×H) |
|---|---|
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20–98 %RH |
| Temp. Stability | ±0.5 °C |
| Humidity Stability | ±2.5 %RH |
| Temp. Uniformity | ±1.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Heating Rate | +20 °C to +150 °C in ≈30 min |
| Cooling Rate | +20 °C to −40 °C in ≈50 min |
| Controller | TEMI880 Touchscreen HMI (Bilingual English/Chinese) |
| Refrigeration System | Hermetic Compressor, R404A/R23 Refrigerants |
| Air Circulation | Multi-wing Centrifugal Fan (Oriental Motor), Horizontal Diffusion + Vertical Thermal Exchange |
| Water Supply | Integrated 25 L Stainless Steel Reservoir with Auto-Replenishment & Low-Water Alarm |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Internal Dimensions | 50 × 75 × 60 cm (W×H×D) |
| External Dimensions | 107 × 175 × 110 cm (W×H×D) |
| Inner Material | SUS#304 Stainless Steel |
| Outer Material | SUS#304 High-Tensile Stainless Steel with Multi-Layer Passivation Coating |
| Insulation | High-Density Glass Wool + Rigid Polyurethane (PU) Foam |
| Refrigerants | R404A & R23 (Zero ODP, Low GWP HFCs) |
| Viewing Window | Multi-Layer Vacuum-Sealed, Explosion-Proof Tempered Glass |
| Air Circulation | Horizontal Diffusion + Vertical Heat Exchange Arc-Type Forced Convection |
| Safety Compliance | Dual-Stage Over-Temp/Over-Humidity Protection, Power-Failure Memory, Door Interlock, Ground Fault Circuit Interrupter (GFCI) |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200–14,800 (FOB, model-dependent) |
| Chamber Volume | 100 L / 225 L / 500 L / 1000 L |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6.0 kW |
| Lamp Life | ≥1,500 h (at nominal irradiance) |
| Spray Cycle | 1–999 min (programmable intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Key Features | Temperature Range: RT+10°C to 132°C |
|---|---|
| Humidity Range | 100% RH (saturated steam) |
| Pressure Range | 0–2.8 kg/cm²(g) (relative gauge pressure) |
| max vessel rating | 4.0 kg/cm²(g) |
| Internal Chamber Dimensions | ∅250×450 mm, ∅350×500 mm (customizable) |
| Temperature Uniformity | ±1.5°C |
| Temperature Control Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Heating Method | Insulated stainless-steel sheathed heaters with PID + SSR control |
| Humidity & Pressure Generation | Saturated steam via electrically heated water reservoir |
| Circulation | Natural convection of saturated steam |
| Chamber Material | SUS304 stainless steel (interior), SECC steel with electrostatic powder coating (exterior) |
| Compliance | ASTM D3045, DIN 53479, ISO 2231, IEC 60068-2-13, JIS C 0021, UL 746B, MIL-STD-810H, NACE TM0177, BS EN 60068-2-30 |
| Safety Systems | Automatic pressure relief, vacuum break, door interlock with pressure-dependent mechanical sealing, low-water auto-refill, real-time fault diagnostics |
| Brand | OEM |
|---|---|
| Internal Chamber Dimensions | ∅250×450 mm (OK-PTC-25) or ∅350×500 mm (OK-PTC-35) |
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max working pressure 3.0 kg/cm² (absolute), safety limit 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0 → 2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Cabinet | SECC steel with electrostatic powder coating |
| Compliance | ASTM D2247, DIN 50017, IEC 60068-2-66, ISO 11357-4, JIS C 0045, MIL-STD-810H, UL 1598, NACE TM0177, BS EN 60068-2-30 |
| Key Features | Internal Chamber Diameter × Depth: ∅250×450 mm (PTC-25) or ∅350×500 mm (PTC-35) |
|---|---|
| Temperature Range | RT+10°C to 132°C |
| Humidity Range | 100% RH |
| Pressure Range | 0.0–2.8 kg/cm² (gauge), max safe capacity 4.0 kg/cm² |
| Temp. Uniformity | ±1.5°C |
| Temp. Control Accuracy | ±0.5°C |
| Temp. Resolution | 0.1°C |
| Pressurization Time (0→2.0 kg/cm²) | ~30 min |
| Inner Chamber Material | SUS304 stainless steel |
| Outer Casing | SECC steel with electrostatic powder coating |
| Compliance | ASTM, DIN, BS, IEC, NACE, UL, CNS, ISO, JIS, MIL |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-CTH100-40 |
| Instrument Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −40 °C to +150 °C |
| Humidity Range | 20 %RH to 98 %RH |
| Temperature Uniformity | ±1.0 °C |
| Temperature Stability | ±1.0 °C |
| Humidity Uniformity | ±2.0 %RH |
| Humidity Stability | ±1.0 %RH |
| Heating Rate | −40 °C to +100 °C in ≤45 min (unloaded) |
| Brand | YueLian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PW-CTS2-50-40W |
| High-Temperature Range | +150 °C |
| Low-Temperature Range | −40 °C |
| Thermal Shock Range | −40 °C to +150 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate | 3 °C/min |
| Cooling Rate | 2 °C/min |
| Transfer Time (Basket) | ≤5 s |
| Thermal Transition Time | ≤15 s |
| Temperature Uniformity | ±2 °C |
| Dwell Time per Zone | 5 min |
| Internal Chamber Dimensions (W×H×D) | 400×400×320 mm |
| External Dimensions (W×H×D) | ≈1200×1840×1875 mm |
| Power Requirement | 8 kW, 380 V, 50/60 Hz |
| Refrigerant | R404A / R23 (non-ozone-depleting, low-GWP blend) |
| Cooling Method | Water-cooled |
| Control Resolution | 0.1 °C (temperature), 1 min (time) |
| Compliance | IEC 60068-3 |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PW-CTS70 |
| Price | Upon Request |
| High-Temperature Range | +180 °C |
| Low-Temperature Range | −70 °C |
| Thermal Shock Range | −70 °C to +180 °C |
| Temperature Control Accuracy | ±1.0 °C |
| Setpoint & Display Resolution | 0.1 °C |
| External Dimensions (W×H×D) | 580 × 1050 × 1000 mm |
| Gas Flow Output | 3–10 L/s |
| Temperature Transition Speed (No-Load, Outlet) | −40 °C ↔ +85 °C in ~10 s (stabilization ≤13 s) |
| Gas Supply Requirement | Dry air or N₂, dew point ≤ −10 °C, inlet temp 20–25 °C, pressure 0.78 MPa, flow rate 14.3 L/s |
| Interface | RS485 |
| Sensor Type | T-type thermocouple |
| User Interface | Touchscreen HMI |
| Operation Modes | Programmed & Constant-Temperature |
| Data Storage | USB flash drive |
| Data Logging | Time-stamped CSV exportable to PC |
| Mobility | Four swivel casters |
| Calibration | Manual |
| Brand | YueLian (PW) |
|---|---|
| Origin | Guangdong, China |
| Model | PW-IP56 |
| Rain Duration | 1–9999 min (adjustable) |
| IP Rating Compliance | IPX3, IPX4, IPX4K, IPX5, IPX6 |
| Spray Nozzle Diameters | φ0.4 mm (IPX3/IPX4), φ6.3 mm (IPX5), φ12.5 mm (IPX6) |
| Water Flow Rates | 2.9 L/min (IPX3), 4.3 L/min (IPX4), 12.5 ±1 L/min (IPX5), 100 ±5 L/min (IPX6) |
| Turntable Diameter | Φ450 mm, Speed: 1–5 rpm (adjustable) |
| Oscillating Pipe Radius | 0.4 m (R400 mm standard), Swing Angle: ±60° or ±160° (configurable) |
| Internal Chamber Dimensions | 1000 × 1000 × 1000 mm (W×H×D) |
| Construction Material | SUS304 stainless steel (1.0 mm thickness, full-welded structure) |
| Control System | PLC + stepper motor + 7-inch color touchscreen HMI |
| Safety Protections | Overload, short-circuit, grounding, low-water level, audible alarm |
| Brand | PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PW-PCT35B |
| Max Operating Temperature | ≤150 °C |
| Internal Chamber Dimensions (Ø×D) | 246 mm × 450 mm |
| Design Pressure Range | 0–3.0 kg/cm² (Safety Relief at 3.5 kg/cm²) |
| Time Setting Range | 0–999 h |
| Temperature Uniformity | ±2.0 °C |
| Heating Rate | RT to 132 °C in ≤35 min |
| Pressurization Time | 0–2.0 kg/cm² in ≤45 min |
| Humidity | 100 % RH (Saturated Steam) |
| Power Supply | AC 220 V, 50/60 Hz, 25 A |
| Brand | Yuelian / PW |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PW-SD150LS |
| Refrigeration Method | Mechanical Compression Refrigeration |
| Temperature Range | −40 °C to +150 °C |
| Temperature Fluctuation | ±0.5 °C (ambient pressure, empty chamber) |
| Temperature Uniformity | ≤2 °C (ambient pressure to 40 kPa, empty chamber) |
| Temperature Deviation | ±0.5 °C (ambient pressure, empty chamber) |
| Ramp Rate (Heating) | ≥1 °C/min (−40 °C to +150 °C, ambient pressure, empty, average) |
| Ramp Rate (Cooling) | ≤40 min (ambient pressure to 1.0 kPa) |
| Internal Chamber Dimensions | 600 D × 500 W × 830 H mm |
| Pressure Range | Ambient (101.3 kPa) to 50 kPa |
| Pressure Control Accuracy | ±2 kPa (≥40 kPa) |
| Compressor | Bitzer or Bock semi-hermetic twin-stage cascade system |
| Vacuum Pump | Leybold oil-sealed rotary vane pump |
| Control System | Japanese Unique industrial-grade 7″ color touchscreen with PID+VRF control logic |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.21, GB/T 2423.25, GB/T 2423.26, GJB 150.1A–150.6, GB/T 10590, GB/T 5170.10, JJF 1101 |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | AIM Box |
| Compliance | ASTM G201, GM 2617M/3619M/7454M/7455M/9538P, Ford DVM 0020, GMW 3417 |
| Light Source | Natural Sunlight with Automotive Glass Filtering |
| Tracking System | Dual-Axis Solar Tracker |
| Temperature Control | Blackboard Thermometer + Active Air-Cooling Fan |
| Sample Capacity | Full-size automotive interior components (dashboards, seats, steering wheels) |
| Spectral Filtering | OEM-grade laminated automotive glass (windshield or side-glass variants per test standard) |
| Operating Environment | Outdoor field exposure site (e.g., Arizona) |
| Calibration & Traceability | ISO/IEC 17025-accredited testing methodology |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CCT-600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray, Dry, 100% RH Humidity, and Hold (Static) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A5 (Prohesion), SAE J2334, GMW 14872, Ford APGE, VW PV1210, Renault D17 2028 |
| Water Requirement | Deionized or purified water only |
| Internal Solution Reservoir | 120 L with level sensor and saltwater filter |
| Controller | Integrated microprocessor-based system with self-diagnostic functions, service alerts, and safety shutdown |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT1100 |
| Chamber Type | Cyclic Corrosion Test Chamber |
| Core Functions | Salt Spray / Dry / High-Humidity (100% RH) Cycling |
| Compliance | ASTM B117, ASTM G85 Annex A5 (Prohesion), ISO 9227, ISO 11997, SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VW PV1210 |
| Control System | Integrated Q-FOG Microprocessor Controller with Real-Time Display and Programmable Cycle Sequencing |
| Chamber Volume | 1100 L (Standard Configuration) |
| Construction | Fiberglass-Reinforced Polymer (FRP) Cabinet with Corrosion-Resistant Interior |
| Humidity Generation | Electric Steam Generator |
| Salt Fog Delivery | Compressed-Air-Driven Atomization via Bubble Tower (except Prohesion mode) |
| Temperature Control | Dual-Heater System (Chamber + Air Stream) |
| Viewing Window | Polycarbonate Side Window with Sealed Gasket |
| Data Logging | Onboard Event Timestamping (Start/Stop/Phase Transition), Optional USB Export |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB CCT1100 |
| Chamber Volume | 1103 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Operating Modes | Salt Spray / Prohesion / 100% RH Humidity / Dry / Static |
| Temperature Range | Ambient to 50 °C (typical operational range per ASTM B117, ISO 9227, SAE J2334) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated air pressure |
| Water Requirement | Deionized or purified water (≥1 MΩ·cm resistivity recommended) |
| Compliance | Designed to meet ASTM G85 Annexes A1–A5, ISO 11997-1/2, VDA 621-415, GMW 14872, Ford CETP 00.00-L-467, SAE J2334 |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CCT600 |
| Chamber Capacity | 640 L |
| Cycle Modes | Salt Spray / Dry / 100% RH / Static |
| Compliance | ASTM B117, ISO 9227, ISO 16701, GMW 14872, SAE J2334, VW PV1210, Ford CETP, Renault D17 2025, Volvo VCS 1027,149, GB/T 10125 |
| Humidity Control | Up to 100% RH with precision air pre-conditioning (CCT-series) |
| Temperature Range | Ambient +10°C to 50°C (operational during spray/dry/RH phases) |
| Salt Solution Delivery | Variable-speed peristaltic pump with independent control of solution flow rate and atomization distance via regulated compressed air |
| Controller | Q-FOG Intelligent Touchscreen Controller with built-in diagnostics, service scheduling, safety shutdown, and audit-trail-ready event logging |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-LAB CCT600 |
| Chamber Capacity | 640 L |
| Sample Capacity | 160 panels (75 mm × 150 mm) |
| Operating Environments | Salt Fog / Dry / 100% RH Humidity / Ambient Hold |
| Temperature Range | Ambient to 50 °C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Precision-controlled via variable-speed peristaltic pump and regulated air pressure |
| Internal Solution Reservoir | 120 L with level sensor and filtration |
| Compliance | Designed to support ASTM B117, ISO 9227, ASTM G85 Annexes (A1–A5), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, and other internationally recognized cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH 1100 |
| Capacity | 1100 L (internal chamber volume) |
| Humidity Control Range | 0–100% RH (programmable, pulse-fogging assisted) |
| Temperature Range | Ambient +10°C to 60°C (typical operational range per ASTM G85 Annexes and ISO 16701) |
| Spray Function | Adjustable flow rate, user-defined on/off timing, non-atomized liquid delivery |
| Compliance | Fully supports GMW 14872, SAE J2334, ISO 16701, ASTM G85 Annexes 1/2/3/5, ISO 9227, IEC 60068-2-52, MIL-STD-810G, and other cyclic corrosion standards requiring precise RH control |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | CRH600-HSC / CRH1100-HSC |
| Salt Fog Deposition Rate | Adjustable via precision peristaltic pump and air pressure regulation |
| Temperature Range | 10°C to 70°C (operational), with rapid transition capability |
| Relative Humidity Control | 10% to 95% RH, ±2% RH accuracy (at 25°C) |
| Chamber Capacity | 640 L (CRH600-HSC) or 1103 L (CRH1100-HSC) |
| Spray Nozzle System | Self-cleaning, modular, DI-water compatible |
| Internal Solution Reservoir | 120 L, with level sensor and particulate filtration |
| Compliance | Designed to meet GMW 14872, SAE J2334, ISO 11997, ASTM B117 (modified), VW PV1210, Ford CETP, Renault D17 2025, GB/T 24135–2009, and other automotive & industrial cyclic corrosion standards |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH1100-HSC |
| Spray Mode | Continuous/Cyclic Spray |
| Temperature Range | 20–70 °C |
| Chamber Volume | 1103 L |
| Humidity Control | Full-Variable RH via Air Preconditioning System |
| Spray Function | Adjustable High-Flow Liquid Shower Module |
| Nozzle Maintenance | Automatic Self-Cleaning Mechanism |
| Internal Solution Reservoir | 120 L with Filtration & Low-Level Alarm |
| Compliance | GMW 14872, SAE J2334, ISO 11997, VW PV1210, Ford CETP, Renault D17 2025, JASO M609, GB/T 24135, Prohesion™ Protocol |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | CRH600 |
| Chamber Volume | 640 L |
| Salt Spray Deposition Rate | Adjustable per ASTM B117 / ISO 9227 |
| Temperature Range | 10–70 °C (operational), with RH control from 10% to 95% RH |
| Humidity Control Method | Pre-conditioned air + ultrasonic misting + forced-air circulation |
| Compliance | GMW 14872, SAE J2334, Ford CETP, ISO 16701, VW PV1210, Renault D17 2025, Volvo VCS 1027, Chrysler MSFC-100, GB/T 10125, ISO 9227, ASTM G85 Annex A5 (Prohesion) |
| Brand | Q-LAB |
|---|---|
| Origin | China (Hubei) |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PWC |
| Quotation | Available Upon Request |
| Xenon Lamp Power | Configurable per IEC 60068-2-5 & ASTM G155 |
| Temperature Range | –10°C to +80°C (operational, ±0.5°C uniformity) |
| Humidity Range | 10% to 95% RH (±3% RH accuracy) |
| Brand | Q-Lab |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Spray Mode | Continuous Spray |
| Spray Rate | 1–5 L/h per 180 cm² |
| Nozzle Pressure | 0.7–1 kg/cm² |
| De-misting Method | Air-pressurized Exhaust |
| Temperature Range | 20–60 °C |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Compliance | ASTM B117, ASTM G85, ISO 9227, BS 3900 F4/F9, DIN 50021 |
| Temperature Range | Ambient to 50°C (operational control stability ±2°C) |
| Salt Solution Delivery | Pneumatic air-assisted atomization with adjustable spray rate (typically 1.0–2.0 mL/80 cm²/h per ASTM B117) |
| Humidity Control | 100% RH capability (CCT-specific) |
| Chamber Volume | Standard 600 L (custom sizes available) |
| Construction | Fiberglass-reinforced polymer (FRP) chamber body with corrosion-resistant stainless steel hardware |
| Control System | 7-inch full-color touchscreen interface with programmable multi-step cycling logic |
| Brand | Q-LAB |
|---|---|
| Origin | USA |
| Model | Q-FOG CCT |
| Chamber Volume Options | 600 L / 1100 L |
| Temperature Range | Ambient to 50°C (typical operational range for cyclic corrosion testing) |
| Salt Solution Delivery | Pneumatic atomization via saturated compressed air and adjustable peristaltic pump |
| Humidity Control | 100% RH via steam generator (CCT-specific) |
| Dry Cycle | Forced-air convection heating with dual heater control (chamber + air heater) |
| Compliance | ASTM B117, ISO 9227, ASTM G85 Annex A1–A5 (Prohesion), SAE J2334, GMW 14872, Ford CETP 00.00-L-467, VDA 621-415, DIN 50017, JIS Z2371 |
| Software Interface | Q-FOG Touchscreen Controller with programmable multi-step cyclic profiles, real-time monitoring, data logging, and audit-ready event history |