| Brand | Aqualab |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AquaLab VSA |
| Price Range | USD 25,000 – 62,500 (converted at ~¥200,000–¥500,000) |
| Measurement Principle | Mirror Condensation Dew Point |
| Isotherm Methods | Dynamic Dew-point Isotherm (DDI) & Dynamic Vapor Sorption (DVS) |
| Accuracy | ±0.005 aw |
| Resolution | ±0.001 aw |
| aw Range | 0.030–0.950 |
| Repeatability | ±0.003 aw |
| Temperature Control | 10–60 °C (STP adjustable) |
| Temp Stability | ±0.1 °C |
| Max Operating Pressure | ≤7 psi |
| Sample Mass Range | 500–5000 mg |
| Mass Resolution | ±0.1 mg |
| Sample Cup Volume | 7.5 mL (recommended), up to 15 mL |
| Water Reservoir Volume | 7 mL (max 15 mL) |
| Display | 128×64-pixel backlit LCD |
| Dimensions | 25.4×38.1×30.5 cm |
| Enclosure | Machined aluminum frame with flame-retardant silicone resin |
| Weight | 14.97 kg |
| Power | 110–220 V AC, 50/60 Hz |
| Operating Environment | 4–60 °C, 10–90% RH (non-condensing) |
| Certifications | CE |
| Warranty | 1 year (parts & labor) |
| Brand | AQUAREAD |
|---|---|
| Origin | Japan |
| Model | MAO-1A |
| Measurement Range | 0–12 mm |
| Resolution | 0.01 mm |
| Display | Digital LCD |
| Probe Material | Precision Alloy |
| Haugh Unit Calculation | Manual via integrated scale (based on albumen height and egg weight) |
| Compliance | Designed for ASTM E1695-08 (Standard Practice for Determination of Haugh Units), ISO 6497:2002 (Animal feeding stuffs — Sampling), and aligned with USDA Agricultural Handbook No. 75 and EU Regulation (EC) No. 589/2008 Annex IV criteria for egg classification |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT110X |
| Extraction Volume | 1 L |
| Operating Temperature | Ambient (20–25 °C) |
| Maximum Pressure | 100 bar |
| Solvent Compatibility | Ethanol, Glycerol, Water, and other GRAS/food-grade solvents |
| Control System | Microprocessor-based with real-time digital display |
| Safety Features | Automatic pressure regulation, fault detection, and audible/visual alarm |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT141 / FT142 |
| Capacity | 10 L or 20 L (selectable) |
| Heating | Steam-jacketed (indirect) + optional direct steam injection |
| Cooling | Water-cooled jacket |
| Vacuum capability | Yes, integrated vacuum system |
| UHT function | FT142 only, up to 140 °C at 3 bar |
| Shear mechanism | High-shear rotor-stator emulsifier with adjustable speed |
| Agitation | Dual-stage — top-mounted light-duty agitator with retractable scraper blades + high-speed homogenizing impeller |
| Sealing | Hygienic mechanical shaft seal with water flush |
| Control | PLC-based electronic control panel with HMI interface |
| Compliance | Designed to meet 3-A Sanitary Standards (hygienic design principles), suitable for GLP-compliant pilot-scale development |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT174X |
| Flow Rate | 12–60 L/h (water-equivalent) |
| Max Processing Temperature | >150 °C |
| Heating Methods | Direct steam injection (DSI) and/or indirect (tubular & plate heat exchangers) |
| Sterilization Mode | Aseptic processing capable |
| Configuration | Modular, reconfigurable via sanitary quick-connect fittings and flexible product tubing |
| Control Interface | Touchscreen HMI with stage-based operator prompts |
| Optional Modules | In-line homogenizer, pre-heater, condenser, CIP system, USB data logging, electronic flow meter |
| Compliance | Designed to meet hygienic design principles per EHEDG Guideline Doc. 8 and 3-A Sanitary Standards 01-05 |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT18MKII |
| Maximum Operating Pressure | 50 bar |
| Membrane Module Options | Ceramic, Spiral-Wound, Hollow-Fiber, Tubular |
| CIP Capability | Yes |
| Backwash Capability | Select Modules |
| Transmembrane Pressure (TMP) Monitoring | Yes (Inlet/Outlet of Retentate & Permeate Lines) |
| Permeate Flow Measurement | Electronic Flowmeter + Optional Mass-Balance Mode |
| Data Logging | Full Sensor Array with Timestamped Export |
| Software Integration | Armfield PC-Based Control & Visualization Suite |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT19 |
| Type | Batch Autoclave for Liquid Bottled Products |
| Application | Thermal Sterilization of Milk and Similar Beverages |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT22 |
| Evaporator Tube Length | 1.36 m |
| Heat Transfer Area | 0.08 m² |
| Evaporation Rate | 10 L/h |
| Steam Consumption | 15 kg/h |
| Operating Steam Pressure | 1.7 bar |
| Condenser Area | 0.17 m² |
| Feed Tank Capacity | 30 L |
| Concentrate Tank Capacity | 5.0 L |
| Condensate Tank Capacity | 5.0 L |
| CIP Pump Flow Rate | 8 L/min (20 ft H₂O) |
| System Vacuum | 225 mmHg |
| Power Supply (FT22-A) | 220–240 V / 1-phase / 50 Hz / 3 kW |
| Power Supply (FT22-B) | 120 V / 1-phase / 60 Hz / 3 kW |
| Height | 2.6 m |
| Width | 0.78 m |
| Depth | 0.65 m |
| Gross Weight | 330 kg |
| Shipping Volume | 2.40 m³ |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT28 |
| Type | Laboratory-Scale Continuous Screw Press |
| Application | Edible Oil Extraction from Oilseeds |
| Capacity | 1–5 kg/h (typical, depending on seed moisture and oil content) |
| Screw Diameter | 28 mm |
| Motor Power | 0.37 kW |
| Speed Control | Variable Frequency Drive (0–60 rpm) |
| Construction | AISI 304 Stainless Steel Contact Parts |
| Feed Hopper Volume | 2 L |
| Dimensions (W×D×H) | 450 × 320 × 680 mm |
| Weight | 42 kg |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT30MKIII |
| Construction | All-Glass Enclosure |
| Design Type | Benchtop Laboratory Spray Dryer |
| Observation Capability | Real-Time Visual Monitoring of Drying Process |
| Feed Capacity | Up to 500 mL/h (Typical Aqueous Solutions) |
| Inlet Temperature Range | 40–220 °C (Adjustable in 1 °C Increments) |
| Outlet Temperature Range | 30–120 °C |
| Atomization | Two-Fluid Nozzle (Compressed Air-Assisted) |
| Drying Chamber Diameter | 120 mm |
| Collection Efficiency | >95% for Particles >1 µm |
| Power Supply | 230 V AC, 50/60 Hz |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT32 |
| Heating Method | Steam-heated |
| Configuration | Twin-drum rotary dryer |
| Application | Laboratory-scale drying and moisture removal studies |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT40 |
| Batch Capacity | 5–20 L |
| Jacket Temperature Range | 1 °C to 85 °C |
| Vessel Material | 316 Stainless Steel |
| Integrated Mixer | Silversen™ High-Shear Impeller |
| Control System | Onboard Touchscreen HMI with Data Logging |
| Heating/Cooling | Dual-Purpose Thermostatic Jacket |
| Compliance | Designed for GLP/GMP-aligned laboratory-scale food process development |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT74XTS |
| Maximum Sterilization Temperature | 150 °C |
| Product Flow Rate | 20 L/h |
| CIP Flow Rate | 120 L/h |
| Sterilization Capacity | 50 L/h (with plate heat exchanger) |
| Holding Time Display | Yes |
| F₀ Calculation & Display | Yes |
| Touchscreen Interface | 800 × 480 px Full-Color LCD |
| Pre-set Programs | 32 |
| Data Logging | USB Storage (standard), PC Connectivity (optional) |
| Flow Measurement | Electromagnetic Flow Sensor |
| Holding Tube | Adjustable |
| Cooling Stages | Single-stage standard, dual-stage optional |
| Heat Exchanger Configurations | Interchangeable plate or tubular modules |
| CIP System | Integrated high-pressure hot water recirculation |
| Enclosure | Integrated stainless-steel cabinet |
| Environmental Rating | IP54-rated for humid laboratory environments |
| Level Sensing | Product tank ultrasonic level sensor |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT80/81 |
| Configuration | Dual-mode (Spray Drying or Spray Cooling) |
| Chamber Aspect Ratio (Height | Diameter): 3:1 |
| Discharge Section | Conical |
| Atomization | Twin-Fluid Nozzle System (Co-current & Counter-current Configurable) |
| Air Handling | Independently Variable-Speed Inlet & Exhaust Fans |
| Filtration Option | Bag Filter Kit Available |
| Monitoring | Integrated Relative Humidity Sensor at Inlet |
| Safety | Spark Arrestor on Inlet Fan |
| Enclosure Rating | IP65 Control Console |
| Data Logging | Full Parameter Recording with USB/PC Export Capability |
| Noise Level | Low-Noise Operation |
| Cleanability | Tool-Free Disassembly for Inspection & Cleaning |
| Mobility | Compact, Wheeled Base Design |
| Compliance Support | Designed for GLP-aligned lab environments |
| Brand | Armfield |
|---|---|
| Origin | United Kingdom |
| Model | FT9 |
| Production Capacity | 45 L/h |
| Maximum Operating Pressure | 70 bar (1015 psi) |
| Homogenization Index (whole milk) | ≤5.0% |
| Feed Tank Capacity | 4.5 L stainless steel (hygienic grade) |
| Pressure Gauge Range | 0–300 bar |
| Motor Power | 0.18 kW |
| Electrical Supply | FT9-A: 220–240 V / 1Φ / 50 Hz |
| FT9-B | 120 V / 1Φ / 60 Hz |
| Dimensions (H×W×L) | 0.56 × 0.56 × 0.41 m |
| Net Weight | 60 kg |
| Material | Hardened stainless steel cylinder, valve, and plunger |
| Homogenization Index compliance | Meets ISO 5530-1 for fat globule size distribution assessment in dairy emulsions |
| Brand | FUNKE GERBER |
|---|---|
| Origin | Italy |
| Model | CryoSpecial 1 |
| Sample Volume | 2–2.5 mL |
| Measurement Principle | Freezing Point Depression (Colligative Property) |
| Temperature Range | +5 °C to +36 °C |
| Resolution | ±0.0005 °C |
| Reproducibility (Raw Milk) | ±0.0025 °C |
| Analysis Time | ~2 min (after preheating) |
| Preheat Time | ~5 min |
| Output Units | °C, °H, % Water Addition |
| Interface | RS232 |
| Power Supply | 220 V / 50 Hz / 150 W |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Cooling System | Peltier-based, Continuous Circulation |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |
| Brand | Axel Semrau |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chronect |
| Pricing | Upon Request |
| Brand | FOSS |
|---|---|
| Origin | Denmark |
| Model | BactoScan FC |
| Measurement Principle | Flow Cytometry |
| Detection Target | Total Viable Bacteria in Raw and Processed Milk |
| Detection Range (L-mode) | 2.0 × 10⁵ – 2.0 × 10⁷ IBC/mL (≈ 8.0 × 10⁴ – 1.0 × 10⁷ CFU/mL) |
| Detection Range (H-mode) | 5.0 × 10³ – 2.0 × 10⁷ IBC/mL (≈ 1.5 × 10³ – 1.0 × 10⁷ CFU/mL) |
| Throughput | 50–150 samples/hour |
| Sample Temperature Range | 2–42 °C |
| Warm-up Time | <15 min |
| Shutdown Time | <5 min |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Bigdipper Industrial Chemistry Research Institute |
| Model | HBD5-MS2100 sWA |
| Measurement Range | 0.003–0.999 a<sub>w</sub> |
| Accuracy | ±0.003 a<sub>w</sub> (at <0.1°C ambient) |
| Repeatability | ±0.015 a<sub>w</sub> (at <±0.3°C ambient) |
| Resolution | 0.001 a<sub>w</sub> |
| Sensor Type | Imported high-precision ERH sensor |
| Sample Chamber Diameter | 48 mm |
| Host Dimensions | 180 × 70 × 50 mm |
| Host Weight | 0.4 kg |
| Power Supply | Rechargeable Ni-Cd battery (2 h continuous operation, 1 week standby) or 220 V AC adapter |
| Operating Environment | 0–50°C, 0–85% RH |
| Compliance | GB/T 34790–2017 |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HBD5ms2100 sMS |
| Water Activity Range | 0.000–1.000 aw |
| Accuracy | ±0.015 aw |
| Repeatability | ±0.005 aw |
| Resolution | 0.001 aw |
| Moisture Content Range | 0.0–100.0% (w/w) |
| Moisture Accuracy | ±2.0% abs |
| Moisture Repeatability | ±0.5% abs |
| Moisture Resolution | 0.1% |
| Operating Temperature | −20 to +85 °C (moisture extension up to 200 °C) |
| Environmental Operating Range | −10 to +60 °C, 0–99% RH |
| Test Modes | Rapid, Pre-cut, Equilibrium |
| Typical Rapid Test Time | 3–5 min |
| Power Supply | Rechargeable NiCd battery (HBD5 variant), 24 h continuous operation, 1 week standby |
| Intrinsic Safety Rating | Ia, suitable for Class 1, Groups A/B/C/D and Class 2, Groups E/F/G hazardous locations |
| Enclosure Rating | NEMA 2 |
| Data Storage | Non-volatile memory (2 MB), power-loss protected |
| Communication Interface | RS-232 / RS-485 |
| Sensor Architecture | Polymer-based capacitive humidity sensor with integrated temperature compensation |
| Calibration | Factory-calibrated |
| Brand | Bosin |
|---|---|
| Model | BS |
| Origin | Shanghai, China |
| Compliance | NY/T 1180–2006 (PRC Agricultural Industry Standard) |
| Max Load Capacity | ≥49 N |
| Force Resolution | ≤0.0098 N |
| Force Accuracy | ±0.02% FS |
| Shear Blade Thickness | 3.0 ± 0.2 mm |
| Blade Included Angle | 60° |
| Triangular Cut Height | ≥35 mm |
| Core Sampler Aperture Width | 4.0 ± 0.2 mm |
| Shear Speed | 1.0 mm/s |
| No-Load Shear Force | ≤0.147 N |
| Calibration Traceability | Certified Standard Weights (±0.1% deviation) |
| Brand | Bosin |
|---|---|
| Model | NS01 |
| Origin | Shanghai, China |
| Force Sensor Capacity | 20 kg (optional: 1/5/10/30/50 kg) |
| Force Accuracy | < ±0.5% FS |
| Load Cell Calibration | Traceable to international standard weights |
| Integrated Weighing Function | 0.1 g resolution |
| Displacement Resolution | 0.01 mm |
| Maximum Travel Distance | 320 mm |
| Test Speed Range | 0.01–20 mm/s (adjustable in 0.01 mm/s increments) |
| Data Acquisition Rate | 20 / 50 / 100 / 200 Hz (user-selectable) |
| Touchscreen Interface | Integrated high-definition capacitive display |
| Safety Features | Emergency stop, mechanical upper/lower limit switches, overload protection |
| Compliance | Designed for GLP-compliant food texture testing per ISO 11036 and ASTM STP 1594 guidelines |
| Brand | Bosin |
|---|---|
| Origin | Shanghai, China |
| Model | TA/VB |
| Unit Price | USD 675 (FOB Shanghai) |
| Probe Type | Dual-Acting Compression-Shear Jaw Fixture |
| Compliance | Designed for ASTM F3102-17 (Standard Test Method for Measuring Textural Properties of Food Using a Texture Analyzer), ISO 11357-4 (Plastics – Differential Scanning Calorimetry), and USP <721> Compendial Requirements for Mechanical Testing of Solid Dosage Forms |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | Amylograph-E |
| Compliance | ICC Standard 110/1, ISO 7973, AACCI Method 22-05 |
| Temperature Ramp | 30–95 °C at 1.5 °C/min |
| Torque Measurement Range | 0–1000 mNm |
| Resolution | 0.1 mNm |
| Sample Volume | 50 g flour + 50 mL water (standard) |
| Real-time Sample Temperature Monitoring | Yes, direct-contact Pt100 sensor |
| Data Output | BU (Brabender Units) / AU (Amylograph Units) |
| Software Integration | MetaBridge Standalone v3.0+ |
| Regulatory Alignment | Supports GLP-compliant audit trails, 21 CFR Part 11–ready configuration options |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Model | ExtensoGraph |
| Compliance | ICC Standard No. 110, AACC Method 54-10, ISO 27971 |
| Temperature Control Range | 20–40 °C (±0.2 °C) |
| Humidity Control Range | 30–95% RH (±2% RH) |
| Measurement Resolution | 0.1 mm (extension), 0.01 N (force) |
| Sample Capacity | Up to 2 × 300 g dough pieces per test cycle |
| Data Export Formats | CSV, XML, PDF |
| Software Platform | MetaBridge v3.2 (FDA 21 CFR Part 11 compliant with audit trail, electronic signatures, and user role management) |
| Brand | Brabender |
|---|---|
| Origin | Germany |
| Model | Glutograph-E |
| Type | Electronic Gluten Extensibility and Elasticity Analyzer |
| Compliance | Designed for ISO 21415-1:2006, AACC Method 38-12A, ICC Standard No. 117/1 |
| Sample Mass | 2–3 g per test |
| Measurement Principle | Controlled-shear rotational deformation under constant torque |
| Output | Shear angle vs. time curve, elasticity index (EI), extensibility index (EX), breakdown time (t₆₀), recovery ratio (%) |
| Brand | Brabender |
|---|---|
| Origin | Germany |
| Model | GlutoPeak |
| Operating Speed | 3333 rpm |
| Test Temperature | 33 °C (thermostatically controlled, double-jacketed cup) |
| Sample Mass | 3–10 g |
| Typical Test Duration | 60–600 s |
| Output Parameters | Peak Time (s), Peak Torque (mN·m), Curve Shape Profile |
| Compliance | Designed for ISO 21415-1, ICC Standard No. 178, AACC Method 22-85 |
| Brand | Anton Paar Brabender |
|---|---|
| Origin | Germany |
| Manufacturer | Anton Paar TorqueTec GmbH (formerly Brabender) |
| Model | ViscoQuick |
| Heating Rate | +20 °C/min |
| Cooling Rate | −15 °C/min |
| Operating Temperature Range | ≤20 °C to ≥95 °C |
| Measurement Principle | Rotational Viscometry (Torque-based) |
| Data Interface | Web-based MetaBridge Software |
| Compliance Support | ASTM D445, ISO 3104, ISO 2555, USP <911>, GLP/GMP-ready audit trail |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | CT3 |
| Load Capacity Options | 100 g, 1000 g, 1500 g, 4500 g, 10 kg, 25 kg, 50 kg |
| Force Resolution | 0.01–5.0 g (model-dependent) |
| Speed Range | 0.01–10 mm/s (two precision ranges) |
| Position Range | 0–101.6 mm |
| Position Resolution | 0.1 mm (0.01 mm with TexturePro CT software) |
| Accuracy | ±0.5% FSR (load), ±0.1% (speed), ±0.1 mm (position) |
| Compliance | ASTM, ISO, AOAC, AACC, BS 757:1975, GB 6783–1994, USP <1160> |
| Test Modes | Compression, Tension, Bloom, TPA, Hold Time, Cycle Count, Static Load, Surimi |
| Connectivity | USB |
| Software | TexturePro CT (for advanced analysis), Texture Loader (for offline program deployment) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CTX |
| Price Range | USD 42,000 – 70,000 |