Food Specialized Instruments
Filter
Showing 151–180 of 796 results
| Brand | Charm |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ROSA M-Reader |
| Price Range | USD 1,400 – 25,000 (FOB) |
| Function Type | Multi-analyte Quantitative Immunoassay Platform |
| Sample Versatility | Cereals, Feed, Nuts, Corn, Wheat, Barley, Soybean Meal, Ground Spices |
| Wavelength Range | Not Applicable (Reflectance-based Optical Detection) |
| Assay Time | ≤5 min per test |
| Repeatability | CV <15% (within-run) |
| Detection Channels | 4 independent optical channels |
| Brand | CHEMSPEED |
|---|---|
| Origin | Switzerland |
| Model | Swing |
| Detection Method | Enzyme Inhibition Rate Method (Spectrophotometry) |
| Application Domain | Food Safety & Pesticide Residue Analysis |
| Compliance Framework | Designed for GLP/GMP-aligned laboratories |
| Automation Level | Fully Integrated Robotic Platform |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | EB 4401 |
| Temperature Range (FOM 320) | 50 °C to 220 °C |
| TPM Measurement Range (FOM 320) | 0 % to 40 % |
| Temperature Range (TFX 422C) | −50 °C to 200 °C |
| pH Range (pHT 810) | 0.0 to 14.0 pH |
| Temperature Range (TLC 730) | −30 °C to 70 °C |
| Temperature Range (EBI 300USB) | −30 °C to 70 °C |
| Data Output | USB-exportable PDF reports |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | FOM 320 |
| Measurement Range (TPM) | 0–40 % |
| Accuracy (TPM) | ±2 % |
| Resolution (TPM) | 0.5 % |
| Temperature Range | +50–+200 °C |
| Temperature Accuracy | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Operating Temperature | −20–+50 °C |
| Storage Temperature | −25–+60 °C |
| Power | 3 V replaceable lithium battery (up to 3-year service life) |
| Dimensions (L×W×H) | 304 × 54 × 22 mm |
| Weight | 200 g |
| Housing Material | Food-grade ABS |
| Protection Rating | IP67 |
| Calibration | Factory-calibrated with certificate |
| Order No. | 1340-1570 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | MAT1100 / MAT1200 / MAT1400 / MAT1500 |
| Detection Principle | Electrochemical (O₂) & Non-Dispersive Infrared (CO₂) |
| Display | High-Brightness TFT Touchscreen |
| Data Storage | 999 Measurements with Timestamp, Operator ID, and Method Metadata |
| Connectivity | USB, RS232, Optional Ethernet |
| Compliance | Designed for GLP/GMP environments |
| Enclosure | IP54-rated metal housing with removable protective cover |
| User Management | Dual-level access control (Operator & Administrator) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | MIA 2020 |
| Alcohol Strength by Volume (ASV) Range | 0.1–99.9 % vol (BASIC) / 0.050–99.980 % vol (Premium) |
| ASV Accuracy | ±0.1 % vol (BASIC) / ±0.005 % vol (Premium) |
| ASV Repeatability | ±0.1 % vol at 15 °C and 25 °C (BASIC) / ±0.01 % vol at 15 °C and 25 °C (Premium) |
| Density Range | 0.5000–2.2500 g/cm³ (d₂₀/₂₀) |
| Density Resolution | 0.0001 g/cm³ (BASIC) / 0.00001 g/cm³ (Premium) |
| Density Repeatability | ±0.0002 g/cm³ (BASIC) / ±0.00002 g/cm³ (Premium) |
| Temperature Sensor | Pt100, 1/3 DIN class |
| Temp. Resolution | 0.05 °C |
| Temp. Repeatability | ±0.05 °C (10–30 °C) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | 10 VA |
| Operating Ambient | 10–30 °C (recommended: 15–25 °C) |
| Dimensions (L×D×H) | 210 × 370 × 380 mm |
| Net Weight | 8.5 kg |
| Interface | RS232 I/O |
| Measurement Cycle Time | ≤6 s |
| Calibration | Fully automated internal calibration |
| Standard Accessories | Power supply unit, waterproof interchangeable mass/volume hydrometer set (stainless steel suspension wire, Ø ≤ 0.2 mm), certified alcohol reference standards, double-walled glass measuring cylinder |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Super Alcomat |
| Alcohol by Volume (ABV) Range | 0.13–98.98% ASV |
| ABV Resolution | 0.01% ASV |
| ABV Repeatability | ±0.03% (at 15–25 °C) |
| Density Range | 0.5000–2.2500 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Operating Temperature | 10–30 °C (optimal at 15–23 °C) |
| Display | Backlit LCD with multi-parameter readout |
| Interface | Waterproof keypad |
| Output | RS-232 for optional thermal printer |
| Compliant Standards | ASTM D1120, ISO 3696 (Grade 3 water), OIV Rec. 22/2007, EU Regulation No 2019/1793 (wine analysis) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Super DEE |
| Instrument Type | Dedicated Alcohol & Volatile Acidity Analyzer for Wine and Beverages |
| Measurement Time | ~3–4 min for 100 mL red wine |
| Alcohol by Volume (ABV) | 0–12% vol |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 35 × 41 × 27 cm |
| Weight | 38 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | UPLAB |
| Wavelength Range | 320–1100 nm (VIS), 190–1100 nm (UV-VIS & UV-VIS AUTO) |
| Wavelength Accuracy | ±2.0 nm (VIS/UV-VIS), ±0.5 nm (UV-VIS AUTO) |
| Wavelength Repeatability | 1 nm (VIS/UV-VIS), 0.2 nm (UV-VIS AUTO) |
| Spectral Bandwidth | 2 nm (1, 4, 5 nm optional) |
| Photometric Accuracy | ±0.5% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A) |
| Photometric Repeatability | 0.3% T (VIS/UV-VIS), 0.2% T (UV-VIS AUTO) |
| Stray Light | ≤0.1% T (NaI at 220 nm |
| 0% T Stability | 0.2% T / 30 min |
| 100% T Stability | 0.001 A / 30 min (at 500 nm, post thermal equilibration) |
| Detector | Silicon photodiode |
| Light Sources | Tungsten halogen lamp (VIS), Deuterium lamp (UV-VIS & UV-VIS AUTO) |
| Display | 16×2 LCD (VIS/UV-VIS), 6-inch high-brightness blue-backlit LCD (UV-VIS AUTO) |
| Operating Modes | Transmittance (T), Absorbance (A), Concentration (C), Kinetics (E) |
| Data Output | USB interface, printer support, PC export via UPSoft software |
| Dimensions | 530 × 410 × 210 mm |
| Weight | 15–18 kg (model-dependent) |
| Power Supply | 220–230 V AC, 50 Hz |
| Power Consumption | 100–140 W |
| Brand | Choppin |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alveolab |
| Price Range | USD 68,000 – 109,000 |
| Brand | COMECAUSE |
|---|---|
| Model | IN-DFZ |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Torque Range | 0–10 N·m |
| Weight | 300 g |
| Dimensions | As per technical documentation |
| Power Supply | AC 200–240 V, 50/60 Hz |
| Motor Power | ≤250 W |
| Mixer Shaft Speed | 63 ± 2 rpm |
| Speed Ratio (Fast/Slow Blades) | 1.50 ± 0.01:1 |
| Bowl Capacity | 300 g |
| Torque Sensor Accuracy | ≥0.5% FS |
| Temperature Control | 30 ± 0.2 °C (via integrated water bath) |
| Water Addition Precision | ±0.2 mL |
| Standard Compliance | GB/T 14614–2019, GB/T 35943–2018 |
| Data Export Format | CSV/Excel-compatible |
| Safety Features | Overload protection, bowl interlock, emergency stop |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IN-Q12 |
| Detection Limit | 1 mg/kg |
| Detection Range | 0–100 mg/kg |
| Absorbance Range | 0.000–4.000 A |
| Repeatability | ±0.1% (A) |
| Repeatability Error | ≤0.003 A |
| Photometric Drift | ±0.002 A (3 min) |
| Absorbance Accuracy | ±2.0% |
| Linearity Error | ±1.0% |
| Detection Channels | ≥12 |
| Processor | ARM Cortex-A7 RK3288 (4-core, 1.88 GHz) |
| Display | 7-inch capacitive touchscreen |
| Power Supply | DC 12 V (compatible with vehicle power & optional 6 Ah rechargeable Li-ion battery) |
| Connectivity | Wi-Fi, Ethernet, GPRS, USB 2.0 |
| Data Output | Thermal printer (embedded), QR code generation, cloud upload via regulatory platform |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LAW. |
| Automation Level | Fully Automatic |
| Measurement Range | Fat 0.01–25% (±0.06%), Protein 2–15% (±0.15%), Lactose 0.01–20% (±0.2%), Non-Fat Solids 3–40% (±0.15%), Density 1000–1160 kg/m³ (±0.3 kg/m³), Water Adulteration 0–70% (±3%), Temperature 5–40 °C (±1 °C), Freezing Point −0.400 to −0.700 °C (±0.005 °C), Ash Content 0.4–4% (±0.05%) |
| Sample Throughput | Up to 30 samples/hour (typical) |
| Interface | Capacitive Touchscreen (7-inch, 1280×800) |
| Calibration | Onboard multi-point calibration with remote validation support |
| Data Storage | Internal SSD (64 GB) + USB export + optional cloud sync |
| Compliance | Designed per ISO 9001 manufacturing standards |
| Origin | Italy |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Cryosmart 1 |
| Pricing | Available Upon Request |
| Brand | CSY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | CSY-ATP |
| Price Range | USD 1–999 (FOB) |
| Detection Principle | Luciferin–Luciferase Bioluminescent Reaction |
| Detection Unit | RLU (Relative Light Unit) |
| Sensitivity | 1 × 10⁻¹⁶ mol ATP |
| Dynamic Range | 1–9999 RLU (customizable up to 999999) |
| Measurement Time | ≤10 s per sample |
| Repeatability | ≤±5% CV |
| Sample Point Capacity | ≥2000 unique locations |
| Data Storage | ≥20,000 test records |
| Connectivity | USB 2.0, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Result Interpretation | Pre-programmed RLU-to-Cleanliness-Level mapping (e.g., Pass/Alert/Fail) with configurable thresholds |
| Brand | Shenfen Instruments (CSY) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY- |
| Price Range | USD 420 – 1,920 |
| Brand | CSY Instruments |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CSY-10CDF |
| Function Type | Multi-analyte (10-channel) Spectrophotometric Analyzer |
| Sample Compatibility | Liquid extracts from tea leaves, tea beverages, instant tea powders, and herbal infusions |
| Wavelength | 410 nm ± 2 nm |
| Measurement Time per Sample | ≤ 3 min |
| Photometric Repeatability | ±1% (Transmittance) |
| Optical Path | 10 mm cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Wavelength Accuracy | < ±2.0 nm |
| Baseline Stability | ±0.001 A/hr |
| Data Storage Capacity | ≥ 8,000 records |
| Display | 7-inch color TFT LCD touchscreen |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Power Supply | AC 100–240 V, 50/60 Hz or optional DC 12 V battery operation |
| Dimensions | 350 × 290 × 130 mm |
| Weight | 3.8 kg |
| Brand | CSY |
|---|---|
| Model | CSY-10JQ |
| Origin | Guangdong, China |
| Detection Principle | Visible Spectrophotometry (410 nm ± 2 nm) |
| Optical Path | 10 × 10 mm Cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Wavelength Accuracy | < 2.0 nm |
| Absorbance Stability | ±0.001 A/hr |
| Linearity Error | ±5 ‰ |
| Measurement Accuracy | ±3% |
| Transmittance Repeatability | ±1% |
| Sample Test Time | ≤ 3 min |
| Data Storage Capacity | ≥ 8,000 records |
| Display | 7-inch Color TFT LCD Touchscreen |
| Connectivity | RS-232, USB, Wi-Fi, Ethernet |
| Printer | Embedded Thermal Printer (ribbon-free, lifetime operation) |
| Channel Configurations | 5–30 customizable photometric channels |
| Power Supply | AC 220 V / DC 12 V portable option |
| Dimensions | 350 × 290 × 130 mm |
| Weight | ~3.2 kg |
| Brand | CSY (Shenzhen Finanalysis Instruments Co., Ltd.) |
|---|---|
| Origin | Shenzhen, China |
| Model | CSY-JAZ |
| Detection Principle | Reflectometric Photometric Scanning of Lateral Flow Immunoassay Strips |
| Optical Source | 450–475 nm LED |
| Detection Speed | 240 tests/hour |
| Repeatability | ≤1% CV (using certified control strips) |
| Inter-instrument Variability | ≤3% (using certified control strips) |
| Detection Mode | Semi-quantitative & quantitative |
| Display | 7-inch true-color capacitive touchscreen (customizable to 10-inch) |
| Strip Width Compatibility | 2–6 mm (customizable) |
| Detection Channels | Single-channel (dual-, 5-, or 10-channel configurations available upon request) |
| Data Interfaces | USB 2.0, RS-232 serial, 10/100M Ethernet |
| Wireless | Integrated Wi-Fi module |
| Power Supply | 12 V DC (vehicle-compatible |
| Data Storage | Embedded high-capacity database with categorized query functionality |
| Barcode/QR Support | Optional integrated barcode scanner or QR code reader (custom OEM/ODM) |
| Line Recognition | Auto-C/T line detection with ±3 mm positional error tolerance |
| Reporting | On-screen concentration display with unit (e.g., µg/kg), thermal printer output (built-in), raw scan curve archiving |
| Regulatory Alignment | Designed to support GLP-compliant workflows |
| Brand | CSY (Shenzhen Finysis Instrument Manufacturing Co., Ltd.) |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Domestic Production | Yes |
| Model | CSY-N24A |
| Function Type | Multi-analyte Rapid Detection System |
| Sample Compatibility | Broad-spectrum for fruits, vegetables, herbs, and fresh produce |
| Wavelength | 412 nm ± 2 nm |
| Optical Path | 10 mm standard cuvette |
| Absorbance Range | 0.000–4.000 ABS |
| Photometric Repeatability | ≤0.1% |
| Photometric Accuracy | ±1% transmittance |
| Inter-channel Variation | ≤0.2% |
| Stability | ±0.001 A/hr |
| Measurement Time per Sample | ≤3 minutes |
| Data Storage Capacity | >800,000 records |
| Display | 10.1″ capacitive touchscreen (1920×1200), Android OS |
| Connectivity | USB, RS-232, Wi-Fi, Bluetooth, MicroSD slot |
| Integrated Thermal Printer | Compliance certificate + QR/barcode hybrid printing |
| Cloud Integration | Compatible with national agricultural traceability platforms (e.g., China National Traceability Platform) |
| Regulatory Alignment | Designed to support GB/T 22292–2017 (Pesticide Residue Testing in Vegetables and Fruits), NY/T 448–2021 (Rapid Detection of Organophosphorus and Carbamate Pesticides), and GLP-aligned data audit trails |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | CTST-I |
| Pricing | Available Upon Request |
| Brand | DAYUAN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DY-6400 |
| Price Range | USD 0.15–1,500 (FOB) |
| Brand | DAYUAN |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HM-PCD |
| Price Range | USD 1,400 – 7,000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) with Disposable Screen-Printed Electrodes (SPEs) |
| Target Analytes | Pb²⁺, Cd²⁺ |
| Analysis Time | ≤4 min per sample (electrochemical step) |
| Operating System | Android-based embedded OS |
| Processor | Allwinner A83T Octa-Core ARM Cortex-A7 @ 2.0 GHz |
| Internal Storage | 16 GB eMMC (expandable to 64 GB via microSD) |
| Display | Capacitive color touchscreen |
| Connectivity | USB 2.0, 10/100 Mbps Ethernet, HDMI output, Bluetooth 4.2, Wi-Fi 802.11 b/g/n |
| Printing | Integrated thermal printer + external printer support via USB or network |
| Data Capacity | ≥100,000 test records with timestamp, operator ID, and calibration metadata |
| Power Supply | 5 V DC adapter + built-in rechargeable Li-ion battery |
| Max Power Consumption | 10 W |
| Compliance | Designed to support GLP-compliant data integrity |
| Brand | DICKEY-john |
|---|---|
| Origin | USA |
| Model | GAC2500 |
| Measurement Principle | 149 MHz Radio Frequency (RF) Dielectric Technology with Real-Time Infrared Temperature Compensation |
| Compliance | NTEP Certified (NIST Handbook 44), ASTM D6437, ISO 712 |
| Display | 7-inch Full-Color TFT Touchscreen Interface |
| Data Storage | Internal Non-Volatile Memory (≥10,000 Test Records) |
| Connectivity | USB 2.0, RS-232, Optional Ethernet Module |
| Sample Throughput | Up to 30 samples/hour (standard drawer) |
| Calibration Compatibility | Backward-Compatible with GAC2100 Calibration Sets |
| Input Peripherals | Optional External Keyboard & Optical Mouse Support |
| Brand | DICKEY-john |
|---|---|
| Origin | USA |
| Model | GAC2500AGRI |
| Measurement Principle | High-Frequency Capacitance & Conductivity (149 MHz) |
| Sample Mass | ~250 g |
| Test Time | 30 s |
| Moisture Range | 5–45% (grain-dependent) |
| Temperature Range | −20 °C to +45 °C |
| Accuracy | ±0.2% (standard deviation) |
| Repeatability | ±0.1% |
| Temperature Compensation | Integrated non-contact sensor |
| Calibration Database | Preloaded for 8 grain types |
| Data Storage | 2500 test records |
| Interface | Ethernet, USB, RS-232 |
| Compliance | NTEP Certified, USDA-UGMA Approved, GLP-ready audit trail support |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | GAC2500I |
| Power Supply | 110–220 V AC, 48–62 Hz, 20 VA |
| Measurement Principle | High-Frequency Capacitance & Conductance Sensing (149 MHz) + Integrated Load Cell |
| Moisture Range | 5–45% w.b. (grain-dependent) |
| Accuracy | ±0.2% w.b. |
| Repeatability | ±0.1% w.b. |
| Resolution | 0.1% w.b. |
| Sample Mass | ~250 g (auto-recognized) |
| Grain Temperature Range | 0–45 °C |
| Operating Ambient | 5–45 °C, 5–95% RH non-condensing |
| Display | Full-color capacitive touchscreen |
| Interfaces | Dual RS-232 serial ports |
| Compliance | USDA/FGIS-UGMA certified methodology |
| Sample Types | Cereals, oilseeds, legumes, grass seeds, vegetable seeds, pelleted feed, nuts (e.g., peanuts, almonds), coffee beans |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | GAC500XT |
| Measurement Principle | Capacitance & Conductivity with Integrated Electronic Balance |
| Moisture Range | 5–45% (grain-dependent) |
| Temperature Range | 0–50°C (32–122°F) |
| Temperature Compensation | Automatic |
| Moisture Repeatability | ±0.2% (application-dependent) |
| Moisture Resolution | 0.1% |
| Sample Type | Whole kernels |
| Sample Mass | ~250 g |
| Display | 128×64-pixel LCD |
| Dimensions (L×W×H) | 34.5×26.5×35 cm |
| Weight | 5.78 kg |
| Measured Parameters | Moisture, Temperature, Approximate Test Weight (Bulk Density) |
| Calibration Sets | 16 user-storable |
| Available Calibrations | >450 grain and oilseed varieties |
| Operating Environment | 5–45°C, 5–95% RH (non-condensing) |
| Power Options | 90–264 V AC, 47–63 Hz |
| DC Input | 12–24 V |
| Vehicle Power | 6 V DC, 0.4 A |
| Languages | 10 preloaded, expandable |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | Instalab 700 Series |
| Measurement Time | ≤10 s per sample |
| Sample Types | Solid grains, oilseeds, flour, feed pellets, meat/ dairy powders, liquids (oils, ethanol solutions) |
| Optical System | Fixed-filter NIR with user-configurable filter sets |
| Display | Full-color capacitive touchscreen interface |
| Data Storage | Up to 3,000 test records |
| Calibration Transfer | Compatible with Instalab 600 calibration models via USB flash drive |
| Environmental Rating | Industrial-grade enclosure rated for lab and production-floor deployment (IP54 equivalent) |
| Temperature Stability | Active thermal compensation to minimize drift |
| Sample Handling | Patented rotating sample cup (standard), optional large-capacity cup and liquid cell |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | MINI-GAC2500 |
| Power Supply | 9 VDC battery |
| Measurement Principle | 149 MHz RF dielectric constant (UGMA-compliant) |
| Sample Volume | 0.47 L |
| Operating Temperature Range | 0–50 °C |
| Analysis Time | ≤10 s |
| Display | LCD (106 × 56 pixels) |
| Connectivity | USB port, Bluetooth |
| Dimensions | 30 × 12 × 21 cm |
| Net Weight | 1.1 kg |
| Key Parameters | Moisture content (% w.b.), Specific weight (kg/hL or lb/bu), Grain temperature (°C) |
| Brand | Dickey-john |
|---|---|
| Origin | USA |
| Model | MINIGAC |
| Measurement Principle | Capacitance & Conductivity with Integrated Level Sensing and Automatic Temperature Compensation |
| Moisture Range | 5–45% (grain-dependent) |
| Grain Temperature Range | 0–50°C (32–122°F) |
| Max Temp Differential (Instrument vs. Sample) | ≤20°C |
| Sample Volume | 0.47 L (1 US pint) |
| Display | LCD (106 × 56 pixels) |
| Dimensions (L×W×H) | 21.1 × 12.2 × 30.2 cm |
| Weight | 1.1 kg |
| Operating Temperature | 5–45°C |
| Operating Humidity | 5–95% non-condensing |
| Power Supply | Pre-installed 9 V DC battery |
| Moisture Accuracy | Compliant with U.S. Federal Grain Inspection Service (FGIS) standards |
| Moisture Repeatability | ±0.2% (grain- and application-dependent) |
| Moisture Resolution | 0.1% |
| Grain Temperature Accuracy | ±0.5°C |
| Temperature Resolution | 0.1°C |
| Calibration Sets | 20 preloaded grain-specific calibrations |
| Grain Compatibility | Whole kernels, no sample preparation required |