Milk Cryoscope
Filter
Showing all 10 results
| Brand | FUNKE GERBER |
|---|---|
| Origin | Italy |
| Model | CryoSpecial 1 |
| Sample Volume | 2–2.5 mL |
| Measurement Principle | Freezing Point Depression (Colligative Property) |
| Temperature Range | +5 °C to +36 °C |
| Resolution | ±0.0005 °C |
| Reproducibility (Raw Milk) | ±0.0025 °C |
| Analysis Time | ~2 min (after preheating) |
| Preheat Time | ~5 min |
| Output Units | °C, °H, % Water Addition |
| Interface | RS232 |
| Power Supply | 220 V / 50 Hz / 150 W |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Cooling System | Peltier-based, Continuous Circulation |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |
| Brand | Funke Gerber |
|---|---|
| Origin | Germany |
| Model | CRYOSTAR I |
| Measurement Range | 0.000 °C to –1.500 °C |
| Sample Volume | 2.2 mL |
| Temperature Resolution | 0.0001 °C |
| Repeatability | ±0.002 °C (typical operational precision ±0.0002 °C) |
| Throughput | 40 samples/hour |
| Dimensions (W×H×D) | 290 × 190 × 380 mm |
| Weight | 12 kg |
| Power Supply | 230/115 V AC, 50–60 Hz, 180 W |
| Interfaces | RS-232 port (1), 6 V printer port |
| Brand | Gerber |
|---|---|
| Origin | Switzerland |
| Model | Cryoscope C1 |
| Measurement Range | 0 to −1000 m°C/m°H |
| Display Resolution | 0.1 m°C/m°H |
| Repeatability | ±2 m°C/m°H (1S.D.) |
| Sample Volume | 2.0–2.5 mL |
| Measurement Time | ~90 s (Rapid Mode: ~30 s) |
| Operating Ambient Temperature | 15–35 °C |
| Relative Humidity | 5–80 % RH |
| Power Supply | 110–240 V, 50/60 Hz |
| Power Consumption | 90 W |
| Dimensions (W×D×H) | 28 × 42 × 32 cm |
| Net Weight | 11 kg |
| Gross Weight | 15 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar Automatic |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Measurement Range | −1.5000 °C to 0.0000 °C |
| Sample Volume | 2.0–2.5 mL |
| Throughput | 40 samples/hour |
| Dimensions (W×H×D) | 44×44×20 cm |
| Test Head Height | 24 cm |
| Net Weight | 14.6 kg |
| Power Supply | 230 V, 50–60 Hz, 180 W + 12 V DC |
| Interface | RS232 |
| Sample Capacity | 12-position automated carousel |
| Compliance | ISO/DIS 5764 |
| Brand | Gerber |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typ. 30/h) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice point curve, ice point value, water adulteration %, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, dual USB ports (U-drive data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.0000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Accuracy | ±0.002 °C (repeatability) |
| Sample Volume | 2.0–2.5 mL |
| Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Cooling Time | ≤15 min to operational temperature |
| Display | Full-color LCD touchscreen |
| Data Interfaces | RS232, 2× USB (U-disk data export) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Repeatability | ±0.002 °C |
| Sample Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Sample Volume | 2.0–2.5 mL |
| Cooling Time to Operating Temperature | ≤15 min |
| Display | Full-color LCD touchscreen |
| Data Output | Ice-point curve, ice-point value, water adulteration percentage, timestamp, operator ID, calibration status, error codes |
| Interfaces | RS232, two USB ports (U-disk data export supported) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions (W×D×H) | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | Funke |
|---|---|
| Origin | Germany |
| Model | CryoStar |
| Measurement Range | 0.000 to −1.5000 °C |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Sample Throughput | 40 samples/hour |
| Sample Volume | 2.0–2.5 mL |
| Display | Color LCD with graphical interface |
| Output | Ice point curve, ice point value (°C), water adulteration percentage, timestamp, date |
| Interfaces | RS-232 serial port, parallel printer port |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 38 × 24 cm |
| Weight | 12 kg |
| Compliance | AOAC Official Method 972.16, GB 5413.38–2016 |
| Brand | LoHand |
|---|---|
| Model | LH-B50 |
| Origin | Zhejiang, China |
| Instrument Type | Milk Cryoscope (Freezing Point Depression Analyzer) |
| Measurement Principle | Thermistor-based freezing point depression detection |
| Sample Volume | ~1.0–1.5 mL |
| Resolution | 0.001 °C |
| Repeatability | ±0.002 °C |
| Operating Temperature Range | 10–30 °C ambient |
| Power Supply | Rechargeable lithium-ion battery (≥8 hrs continuous operation) |
| Compliance | Designed per ISO 5725 (accuracy verification), aligned with IDF Standard 192 (Milk Cryoscopy), and supports GLP data integrity requirements |
| Brand | Astori |
|---|---|
| Origin | Italy |
| Model | CryoTouch 1 |
| Display | 7-inch full-color touchscreen |
| Sample Volume | 2–2.5 mL |
| Analysis Time | ~2 min |
| Preheating Time | ~5 min |
| Temperature Range (Ambient) | +5°C to +36°C |
| Resolution | ±0.0005 °C |
| Repeatability (Raw Milk) | ±0.0025 °C |
| Output Units | °C, °H, % Water |
| Data Storage Capacity | >4,000 results |
| Interface | USB, RS-232 |
| Optional | EP-50 thermal printer |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Power Supply | 220 V / 50 Hz / 150 W |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |