Gas Detector
Filter
Showing 361–390 of 1055 results
| Brand | BGI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PQ200 |
| Pricing | Upon Request |
| Brand | BGI |
|---|---|
| Origin | USA |
| Model | VSCC |
| Regulatory Designation | U.S. EPA Reference Method (RFPS-0498-116) |
| EPA EQPM Certification | EQPM-0202-1428 (upgraded to Reference Method, October 17, 2006) |
| Cutpoint | 2.5 µm aerodynamic diameter (D₅₀) |
| Operating Principle | Inertial cyclonic separation |
| Maintenance Interval | Up to 30 days continuous 24-hr sampling before cleaning |
| Cleaning Method | Dry, tool-free, field-cleanable with lint-free cloth and deionized water |
| Compatibility | Direct drop-in replacement for WINS impactor-based FRM samplers (e.g., Thermo Fisher Partisol 2025, Teledyne API models, Met One BAM-1020, etc.) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HBD5-OPA4110TP |
| Measurement Principle | Optical Light Scattering (Nephelometric) |
| Range Options | 0.003–33 mg/m³ (100×), 0.03–330 mg/m³ (10×), 0.8–32,000 g/m³ (X), or 15×0.02–166 g/m³ (15×) |
| Accuracy | ±2% or ±0.8 g/m³ (water fog reference), whichever is greater |
| Calibration | Dual-point 2KS calibration |
| Response Time | ≤1 s |
| Operating Temperature | 0–70 °C |
| Power Supply | NiCd ×8 battery pack (1 h continuous operation) |
| Dimensions (Meter) | 98 × 150 × 30 mm |
| Sensor Dimensions | Ø24 × 360 mm |
| Weight | 0.7 kg |
| Display | 16×2 LCD with backlight |
| Data Logging | 24 records per calibration table (up to 8 tables) |
| Communication | RS-232 / RS-485 serial interface |
| Compliance | Designed for field-deployable environmental and industrial aerosol monitoring per ISO 7706 (airborne oil mist), ASTM D6340 (aerosol mass concentration), and EPA Method 9031 (nephelometric turbidity correlation) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable |
| Detection Principle | Multi-sensor Fusion (Electrochemical, PID, NDIR, Catalytic Combustion, Semiconductor, Metal Oxide) |
| Accuracy | ±1–2% of reading (typ.) |
| Flow Rate | 0.1 L/min |
| Response Time | <1 min (T90) |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Power Supply | Rechargeable 12 V battery |
| Sensor Channels | Configurable from 4 to 23 gas-specific sensors |
| Compliance | Designed per GB 14554–1993 “Emission Standard of Odorous Pollutants” |
| Data Interface | RS232 / RS485 |
| Calibration | Dual-standard (DKA) and single-point inert gas zeroing |
| Cross-interference Compensation | Neural network-based real-time correction algorithm |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Bigdipper Instruments Co., Ltd. |
| Model | pAir2000-EFF-A1 |
| Instrument Type | Portable |
| Detection Principle | Multi-sensor array (electrochemical, metal oxide semiconductor, photoionization detection/PID) |
| Accuracy | ±1% of reading |
| Response Time | < 10 ms |
| Operating Temperature | -10°C to 60°C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Gas Measurement Range | NH₃ (0.5–200 ppm), H₂S (0.3–100 ppm), ODU (0–10,000, unitless) |
| Resolution | 0.01 ppm (NH₃, H₂S), 0.1% FS (full scale) |
| Long-term Stability | ±10% per year |
| Power Supply | 12 V rechargeable battery |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Compliance | NY/T 388–1999 (China Agricultural Standard for Odor Concentration Determination) |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | pAir2000-EFF-D |
| Instrument Type | Portable |
| Detection Principles | Electrochemical, Metal Oxide Semiconductor (MOS), Photoionization Detector (PID), Non-Dispersive Infrared (NDIR), UV-Vis Spectrophotometry |
| Accuracy | ±1–2% of reading |
| Flow Rate | 0.1 L/min |
| Response Time (T90) | <3 minutes |
| Operating Temperature | −10 °C to +60 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Power Supply | 12 V rechargeable battery |
| Dimensions | 400 × 300 × 200 mm |
| Weight | 4.5 kg |
| Sensor Resolution | 0.1% FS |
| Long-Term Stability | ±10% per year |
| Display | 4×16-character LCD |
| Communication Interfaces | RS232 / RS485 |
| Calibration Options | Single-point inert gas zeroing, dual-standard (DKA) calibration with certified reference gases or traceable surrogates |
| Cross-Interference Compensation | Neural network-based multi-gas interference correction algorithm |
| Brand | Bigdipper |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Model | wAir2000SR-5s01 (CO, CO₂, NH₃, Toxic Gas, O₂) |
| Detection Parameters | CO (0.1–500/1000 ppm), CO₂ (0–1/5 %v/v), NH₃ (0.1–100 ppm), Toxic Gas (0.1–1000 ppm), O₂ (0–30 %v/v) |
| Temperature Range | −40 to +100 °C |
| Humidity Range | 0–99 %RH |
| Accuracy | ±2% R (CO, O₂), ±1% R (CO₂), ±10% R (NH₃), ±5% R (Tox) |
| Repeatability | Specified per gas |
| Display | 4×16 Character LCD |
| Communication | RS232/RS485 Dual-Mode Serial Interface |
| Power Supply | 220 V AC, <10 W |
| Enclosure Rating | NEMA 4 / IP56 |
| Dimensions | 300 × 500 × 250 mm (W×H×D) |
| Data Logging | 24 Groups (Non-Volatile Memory) |
| Warm-up Time | 3–5 min |
| Mounting | Wall-Mounted Fixed Installation |
| Brand | BlueJing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-JK90-CH2O |
| Detection Principle | Electrochemical Sensor (Formaldehyde-Specific) |
| Measurement Range | 0–100 ppm, 500 ppm, 2000 ppm, 5000 ppm, 10,000 ppm, 20,000 ppm, 50,000 ppm, or 0–20% Vol (configurable per application) |
| Repeatability | ≤±2% FS |
| Sampling Method | Built-in diaphragm pump (800 mL/min flow rate) |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Display | 3.5″ TFT color LCD (320 × 240 px) |
| Data Storage | Standard 100,000 records |
| Battery | 3.6 V DC, 10,000 mAh rechargeable polymer lithium battery |
| Protection Rating | IP66 |
| Explosion Protection | Ex ia II CT6 (Intrinsic Safety) |
| Dimensions | 230 × 210 × 120 mm (L × H × W) |
| Weight | 2.5 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GXH-3011A |
| Instrument Type | Portable |
| Detection Target | Single-component (CO only) |
| Measurement Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time (t₀–t₉₀) | ≤30 s |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 245 × 190 × 85 mm |
| Weight | ≤3 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer | AMETEK Arizona |
| Type | Online Fixed-Station Monitor |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | ≤60 s |
| Measurement Accuracy | ±0.001 mg/m³ |
| Measurement Range | 0.003–0.999 mg/m³ |
| Sensor Technology | Gold Film Amalgamation |
| Environmental Rating | IP65 Enclosure |
| Operating Temperature | –20 °C to +50 °C |
| Data Output | Modbus RTU/TCP, Ethernet, Optional 4G LTE |
| Alarm Outputs | Relay + Email/SMS Notification |
| Compliance | OSHA PEL (0.1 mg/m³), NIOSH REL (0.05 mg/m³), ACGIH TLV (0.025 mg/m³), MSHA Standards |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J405 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 2 seconds |
| Measurement Accuracy | ±0.01 µg/m³ (±0.00001 mg/m³) |
| Measurement Range | 0.5–999 µg/m³ |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J505 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 8 s (Search Mode) |
| Measurement Accuracy | ±15% at 0.3 µg/m³ |
| Measurement Range | 0.05 µg/m³ to 500 µg/m³ |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX II-MG |
| Detection Scope | Simultaneous Quantification of Major, Minor, and Trace Gaseous Impurities (ppb to % v/v) |
| Optical Path Length Options | 10 cm – 26 m (Heated Up to >180 °C for Condensable Gases) |
| Compliance | Designed for ISO 14644-8, ASTM D7538, IEC 62409, and GLP/GMP-Ready Data Integrity Architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MGA10-GP |
| Measurement Principle | Mid-Infrared Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Simultaneous Target Gases | CH₄, CO, CO₂, SO₂, NH₃, N₂O, NO, NO₂, H₂O, O₃, COS, HCHO, HONO |
| Measurement Frequency | 1 Hz or 10 Hz (user-selectable) |
| Detection Limit | Sub-ppb to low-ppb range for most analytes |
| Interference Resistance | High specificity due to narrow-linewidth QCL emission and spectral fingerprint matching |
| Operating Environments | Laboratory, mobile platforms (aircraft, vehicle, ship), and unattended ground stations |
| Compliance | Designed to support ISO 14064-1/2, EPA Method TO-15 & ASTM D6348, and GLP/GMP-aligned data integrity workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | OMEGA 5 |
| Principle | Infrared Absorption Spectroscopy (FTIR) |
| Type | Online, Real-time |
| Response Time | <1 s |
| Detection Range | ppb to 100% |
| Sample Compatibility | >300 gas compounds |
| Gas Cell | 5 m multipass reflective cell with nickel-plated body and gold-coated mirrors |
| Interferometer | RockSolid™ permanent alignment |
| Detector | Thermoelectrically cooled MCT |
| Light Source | CenterGlow™ broadband IR source |
| Software | OPUS GA v8.x with spectral library and nonlinear fitting engine |
| Compliance | ASTM D6348, ISO 12039, USP <1227>, GLP/GMP-ready audit trail |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GasAlert MCXL-4 |
| Type | Portable Multigas Detector |
| Response Time | <15 s (T90) |
| Detection Gases | H₂S (0–100 ppm), CO (0–500 ppm), O₂ (0–30.0% vol), Combustible Gas (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (Combustible) |
| Operating Temperature | –20 to +58 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| IP Rating | IP66/IP67 |
| Battery Life | Up to 12 h (typical, Li-polymer) |
| Charging Time | <3 h |
| Alarm Types | Visual (bright LED strobe), Audible (95 dB), Vibration |
| Compliance | CSA/UL Class I Div 1, ATEX II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, UKCA, RoHS, REACH |
| Calibration | Auto-bump test & calibration compatible with BW MicroDock II system |
| Data Logging | Internal event logging (alarm triggers, calibration events, bump tests, faults) |
| Display | Backlit LCD with real-time gas concentration readouts |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GAMAX-XT4 |
| Type | Portable Pumped Multigas Detector |
| Response Time | <15 s (typical, per sensor) |
| Repeatability | ±2% of reading (H₂S, CO, O₂, combustible gas) |
| Gas Channels | H₂S (0–200 ppm), CO (0–1000 ppm), O₂ (0–30.0% vol), Combustible (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (combustible) |
| Dimensions | 13.1 × 7.0 × 5.2 cm |
| Weight | 316 g |
| Operating Temp. | –20 to 50 °C |
| Humidity | 10–95% RH (non-condensing) |
| IP Rating | IP66/IP67 |
| Certifications | ATEX II 1G Ga Ex ia IIC T4, IECEx Ga Ex ia IIC T4, CSA Class I, Div. 1, Groups A, B, C, D |
| Alarm Types | Visual (LED strobe), Audible (95 dB), Vibration |
| Pump Draw Distance | Up to 20 m |
| Data Logging | Internal event & sample logging with time stamp |
| Compliance | Meets IEC 61508 SIL 2 (for safety functions), EN 45544-1, EN 45544-2, and supports GLP/GMP audit trails via Fleet Manager II |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | QT |
| Type | Portable Multigas Detector |
| Response Time | <15 s (T90) |
| Detection Gases | H₂S (0–200 ppm), CO (0–1000 ppm), O₂ (0–30.0% vol), Combustible Gas (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (Combustible) |
| Operating Temperature | −20 to +50 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Dimensions | 13.0 × 8.1 × 4.7 cm |
| Weight | 316 g (rechargeable battery), 338 g (alkaline) |
| Alarm Types | Visual (6 red LEDs, IntelliFlash beacon), Vibration, Audible (95 dB @ 30 cm) |
| Battery Life | 14 h (alkaline, 20–50 °C), 20 h (rechargeable, 20–50 °C), 18 h (rechargeable, −20–0 °C) |
| Compliance | CSA/UL Class I Div 1, ATEX II 1G Ex ia IIC T4 Ga, IECEx ia IIC T4 Ga, UKCA, RoHS, REACH |
| Data Logging | Internal event and exposure history (≥5,000 records), time-stamped, with user-accessible USB export |
| Calibration | Auto-bump test & calibration via MicroDock II docking station |
| Cross-Sensitivity Mitigation | Enhanced CO & H₂S sensor algorithms for reduced interference from methanol, ethanol, and other common VOCs |
| Language Support | English, French, German, Spanish, Portuguese |
| Brand | CASP |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | AGHJ-I-LIDAR(HPL) |
| Price Range | USD 140,000 – 280,000 |
| Laser Source | Nd:YAG / Solid-State Laser Diode |
| Detector | High-Sensitivity, Low-Noise Photomultiplier Tube (PMT) |
| Operating Wavelength | 532 nm |
| Maximum Detection Altitude | 20 km |
| Pulse Repetition Rate | 2–2.5 kHz |
| Brand | Catalytic |
|---|---|
| Origin | Germany |
| Model | CS015 |
| Operating Temperature | 350 °C |
| Standard Flow Rate | 1.5 L/min (STP) |
| Oxidation Efficiency | ≥99.9% for n-tetradecane (PMP-compliant) |
| Power Supply | 100–240 V AC, 50/60 Hz, 210 W |
| Communication Interface | USB with MODBUS protocol |
| Inlet/Outlet Diameter | 6 mm |
| Exit Temperature | Ambient + 25 °C |
| Particle Loss Optimization | Minimized for solid particles ≥50 nm at 1 mg/m³ mass concentration |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Model | CCHZ-1000 |
| Measurement Principle | Light Scattering |
| Safety Rating | Exib I (150 °C) Intrinsically Safe |
| Measurement Range | 0–1000 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±10% |
| Relative Stability Error | ±2.5% |
| Sampling Flow Rate | 2.0 L/min (±2.5%) |
| Data Storage Capacity | 50 test records |
| Dimensions | 220 × 150 × 82 mm |
| Weight | 1.9 kg |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | P-51 |
| Pricing | Upon Request |
| Detection Principle | Colorimetric Gas Detection Tube Method |
| Compliance | Designed to meet CDC-recommended field screening protocols for emergency response and occupational health assessments |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CE318 |
| Pricing | Available Upon Request |
| Brand | FPI (Focus Photonics Inc.) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CMS odor 1000 |
| Detection Principle | Gas Chromatography–Ion Mobility Spectrometry (GC-IMS) |
| Instrument Type | Online Analytical System |
| Typical Configuration | Multi-Compound VOC & Odorant Analyzer |
| Regulatory Compliance | GB 14554–201X, DB31/1025–2016, DB12/059–2018 (22 regulated odorants, qualitative & quantitative) |
| Detection Limit | Sub-ppt (parts-per-quadrillion) for key sulfur/nitrogen compounds |
| Resolution | 100 (IMS drift time resolution, FWHM) |
| Accuracy | ≤10% RSD (relative standard deviation) for calibrated odorants |
| Response Time | ≤10 s (IMS-only mode) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-CL1 |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, 100% ±30% at 0.5 µm and 5.0 µm |
| Accuracy (Particle Concentration) | ±30% at 0.5 µm |
| Repeatability (Relative Standard Deviation) | ≤±10% |
| Zero Count Level | ≤1 count per 5 minutes |
| Self-Cleaning Time | ≤10 min |
| Operating Temperature | 15–35 °C |
| Relative Humidity | 10–85% RH (non-condensing) |
| Display | 7-inch color capacitive touchscreen |
| Data Storage Capacity | Up to 100,000 records |
| Connectivity | Wi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A (driver-free U-disk export) |
| Power Supply | Rechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh) |
| Battery Runtime | ≥6 hours continuous sampling |
| Charging Time | ≤2 hours |
| Printer | Built-in high-speed thermal printer (selectable channel output) |
| Compliance | GB/T 6167–2007, JJF 1190–2008, ISO 14644-1, Fed Std 209E, Annex 1 of EU GMP (2022), USP <788>, FDA 21 CFR Part 11 (audit trail enabled in platform mode) |
| Brand | COMECAUSE |
|---|---|
| Model | IN-CL2 |
| Sampling Flow Rate | 2.83 L/min (0.1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Counting Efficiency | ≥50% at 0.3 µm, ≥100% at ≥0.5 µm |
| Zero Count Level | ≤1 count/5 min |
| Self-Cleaning Time | ≤10 min |
| Size Accuracy | ±30% at 0.5 µm and 5.0 µm |
| Concentration Accuracy | ±30% at 0.5 µm |
| Repeatability | ≤±10% CV |
| Operating Environment | 15–35 °C, 10–85% RH (non-condensing) |
| Data Storage Capacity | Up to 100,000 records |
| Display | 7-inch capacitive color touchscreen |
| Power Supply | Internal rechargeable Li-ion battery (16.8 V / 5 Ah, 74 Wh) |
| Battery Runtime | ≥6 h continuous sampling |
| Charging Time | ≤2 h |
| Communication | Wi-Fi 802.11 b/g/n, Bluetooth 4.2, USB Type-A for direct data export |
| Regulatory Compliance | GB/T 6167–2007, JJF 1190–2008, ISO 14644-1, FS-209E, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | IN-CL3 |
| Sampling Flow Rate | 28.3 L/min (1 cfm) |
| Particle Size Channels | 0.3, 0.5, 1.0, 3.0, 5.0, 10.0 µm |
| Self-Cleaning Time | ≤10 min |
| Size Accuracy (0.5 & 5.0 µm) | ±30% |
| Concentration Accuracy (0.5 µm) | ±30% |
| Repeatability | ≤±10% |
| Operating Temperature | 15–35 °C |
| Relative Humidity Range | 10–85% RH |
| Data Storage Capacity | 10,000 records |
| Battery Life | ≥6 h (continuous sampling) |
| Power Supply | AC/DC dual-mode, 16.8 V / 15 Ah Li-ion battery |
| Display | 7-inch color capacitive touchscreen |
| Connectivity | Wi-Fi, Bluetooth, USB flash drive support |
| Calibration Standard | JJF 1190–2008 |
| Performance Verification Standard | GB/T 6167–2007 |
| Cleanroom Classification Support | ISO 14644-1, FS209E, GMP (static/dynamic) |
| Brand | COMECAUSE |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | IN-SCL |
| Price | ¥6,100 |
| Light Source | Semiconductor Laser (Lifespan >35,000 h) |
| Sampling Flow Rate | 2.83 L/min (±5%) |
| Particle Size Channels | 0.3, 0.5, 1.0, 2.5, 5.0, 10.0 µm |
| Max Count Capacity | 35,000 particles/L (≥0.5 µm) |
| Counting Repeatability | <10% RSD |
| Size Distribution Accuracy | ±30% at 0.5 µm |
| Display | Capacitive Touch LCD |
| Data Storage | 4 GB internal (100,000 records max) |
| Battery | 3.7 V / 10,000 mAh Li-ion (≥8 h operation) |
| Connectivity | Dual USB, Wi-Fi, Bluetooth |
| Environmental Operating Range | 0–40 °C, 10–75% RH |
| Compliance | JJF 1190–2008, GB/T 6167–2007, ISO 14644-1, ISO 209, EU GMP Annex 1 (dynamic/static), USP <788>, FDA 21 CFR Part 11 (audit trail enabled) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AAG-1000 |
| Negative Ion Output | ≥ 3 × 10⁶ pcs/cm³ |
| Residual Ozone Concentration | ≤ 0.05 ppm |
| Operating Voltage | 21–27 V DC |
| Operating Current | ≤ 30 mA |
| Output High Voltage | –3.5 ± 0.5 kV (1 G) |
| Protection Impedance | 20 ± 2 MΩ |
| Dielectric Withstand Voltage | ≥ 3750 V AC |
| Dimensions | 67.8 × 44.9 × 22 mm (W × H × D) |
| EMC Compliance | ISO 11452-4 & ISO 16750-2 |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ACDS-1001 |
| Detection Principle | Dual-channel NDIR (Non-Dispersive Infrared) |
| Gas Measured | CO₂ |
| Measurement Range | 0–10,000 ppm (extended capability up to 40,000 ppm) |
| Resolution | 1 ppm |
| Accuracy | ±(50 ppm + 5% of reading) |
| Response Time (T90) | ≤25 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | LIN bus |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +95 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Operating Pressure | 80–120 kPa |
| IP Rating | IP54 |
| Supply Voltage | 9–16 VDC (nominal 12 VDC) |
| Average Current Consumption | ≤100 mA @ 12 VDC |
| Standby Current | <100 µA |
| Design Lifetime | 15 years |
| Compliance | AEC-Q200 qualified circuit architecture, automotive-grade EMI/EMC robustness |