Gas Detector
Filter
Showing 421–450 of 2968 results
| Brand | BJBY |
|---|---|
| Origin | Beijing, China |
| Model | HX-2800 |
| Instrument Type | Portable |
| Detection Principle | Non-Dispersive Infrared (NDIR) Spectroscopy |
| Measurement Range | CO: 0–100 ppm, CO₂: 0–5000 ppm |
| Resolution | CO: 0.1 ppm, CO₂: 0.001% (10 ppm) |
| Linearity Error | ≤±2% FS |
| Repeatability | ≤1.0% FS |
| Zero Drift | ≤±2% FS/h |
| Span Drift | ≤±2% FS/3h |
| Response Time | CO ≤60 s, CO₂ ≤30 s |
| Preheat Time | 30 min |
| Flow Rate | 0.5–2.0 L/min |
| Digital Interfaces | RS-232, USB, Modbus RTU via RS-485 |
| Data Storage Capacity | Up to 5000 measurement records |
| Display | Color TFT touchscreen |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Alarm | Visual and audible alarm with configurable thresholds |
| Compliance | GB/T 18204.23–2000, GB/T 9801–1988, GB/T 18204.24–2000, JJG 635–2011 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M40•M |
| Price | Upon Request |
| Certification | China MA (Mine Safety Approval), CMC (China Metrology Accreditation), Explosion-Proof Certification |
| IP Rating | IP65 |
| Operating Temperature | −20 °C to +50 °C |
| Humidity Range | 15–95% RH (continuous), 0–99% RH (intermittent, non-condensing) |
| Dimensions | 10.9 cm × 6.22 cm × 3.48 cm |
| Weight | 244 g (instrument only) |
| Battery | Rechargeable Li-ion |
| Runtime | 18 h (detector only), 12 h (with pump) |
| Gas Detection Ranges | O₂ (0–30% vol, ±0.1%), H₂S (0–500 ppm, ±1 ppm), CO (0–999 ppm / 0–1999 ppm, ±1 ppm), CH₄ (0–5% vol, ±0.1%) |
| Data Logging | 50-hour black-box recording (4-gas synchronized) |
| Alarm Types | Visual (high-intensity LED), Audible (90 dB), Vibratory |
| Pump Option | Integrated SP40•M remote sampling pump (up to 15 m suction distance) |
| Brand | BlueJing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | LJ-JK90-CH2O |
| Detection Principle | Electrochemical Sensor (Formaldehyde-Specific) |
| Measurement Range | 0–100 ppm, 500 ppm, 2000 ppm, 5000 ppm, 10,000 ppm, 20,000 ppm, 50,000 ppm, or 0–20% Vol (configurable per application) |
| Repeatability | ≤±2% FS |
| Sampling Method | Built-in diaphragm pump (800 mL/min flow rate) |
| Response Time | T90 ≤ 20 s |
| Operating Temperature | −40 °C to +70 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Display | 3.5″ TFT color LCD (320 × 240 px) |
| Data Storage | Standard 100,000 records |
| Battery | 3.6 V DC, 10,000 mAh rechargeable polymer lithium battery |
| Protection Rating | IP66 |
| Explosion Protection | Ex ia II CT6 (Intrinsic Safety) |
| Dimensions | 230 × 210 × 120 mm (L × H × W) |
| Weight | 2.5 kg |
| Brand | BMI/Brechtel Manufacturing Inc. |
|---|---|
| Origin | USA |
| Model | MCPC |
| Particle Size Range | 5–3000 nm |
| Response Time | 180 ms |
| Minimum Detectable Size | 5 nm |
| Saturation Temperature | 45°C |
| Condenser Temperature | 20°C |
| Optical Block Temperature | 30°C |
| Minimum Detectable Concentration | 0.001 particles/cm³ |
| Maximum Concentration (before coincidence error >5%) | ~60,000 particles/cm³ |
| Coincidence Error at 100,000 particles/cm³ | 35% |
| Aerosol Flow Rate | 0.36 L/min |
| Sheath Air Flow Rate | 0.36 L/min |
| Total Exhaust Flow | 2 L/min |
| Working Fluid | Reagent-Grade n-Butanol |
| Butanol Consumption | 1.5 mL/h (≈250 mL/week) |
| Fluid Reservoir Capacity | 250 mL |
| Output Signal | Digital pulse, 0–5 V TTL-compatible |
| Warm-up Time | 5 min (at 20°C ambient) |
| Dimensions | 20.32 × 14.61 × 13.46 cm |
| Weight | 2.95 kg |
| Accuracy | ±3% (3σ, validated against NIST-traceable CPC standards) |
| Tilt Tolerance | Stable up to 12° inclination |
| Compliance | Designed for GLP-compliant field deployment |
| compatible with ASTM D8196-22 (CPC performance verification), ISO 27891 | 2021 (aerosol instrumentation calibration), and USP <788> particulate matter testing workflows |
| Brand | BMI/Brechtel Manufacturing Inc. |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | Model 4002 |
| Price | Upon Request |
| Inlet Cut-Off Size | 1.0 µm or 2.5 µm |
| Sample Flow Rate | 15.0 L/min |
| Steam Generator Liquid Flow | 1.5 mL/min |
| Nebulizer Water/Sample Flow (Syringe Pump) | 0.03–1.0 mL/min |
| Nebulizer Tip Temperature | 98.5 ± 1.5 °C |
| Heater Temperature Range | 100–300 °C |
| Droplet Cut-Off Size | 1.0 µm |
| LOD for Inorganic Ions (SO₄²⁻, NO₃⁻, Cl⁻, NH₄⁺, K⁺, Na⁺, Ca²⁺, Mg²⁺) | 100 ng/m³ |
| LOD for Organic Acids (Acetate, Formate, Oxalate) | 50 ng/m³ |
| LOD for Water-Soluble Organic Carbon (WSOC) | 10 ppb |
| Sampler Capacity | 38 or 80 vials |
| Vial Volume Options | 1, 2, 10, 12, 20 mL |
| Minimum/Maximum Collection Time per Vial | 30 s – 12 h |
| Collected Liquid Volume per Vial | 0.03–20 mL |
| Operating Temperature | 15–45 °C |
| Power Input | 100–230 VAC |
| Max Current (Autosampler) | 1.5–2.5 A |
| Dimensions (w×d×h, with autosampler) | 43 × 48 × 69 cm |
| Weight (with autosampler) | 52 kg |
| Brand | Boreal Laser |
|---|---|
| Origin | Canada |
| Model | GasFinder3-DC |
| Type | Portable In-Situ Analyzer |
| Measurement Principle | TDLAS with Wavelength Modulation Spectroscopy (WMS) |
| Response Time | 1 s |
| Accuracy | ±2% FS |
| Repeatability | CH₄, CO₂, H₂S, NH₃, C₂H₂, O₂ |
| Output Options | Up to three 4–20 mA analog outputs and dry-contact relays per channel (enhanced configuration) |
| Communication Protocols | RS-232, RS-485 (Modbus RTU), Ethernet (TCP/IP, Telnet) |
| Display & Control | Integrated HMI touchscreen or remote GasView software |
| Operating Temperature | −40 °C to +50 °C |
| Enclosure Rating | IP66 / NEMA 4X |
| Laser Source | Semiconductor diode laser (~10 mW output) |
| Laser Safety Class | IEC 60825-1 Class 1 AEL |
| Hazardous Area Certification | NA Class I, Zone 2, IIC, T4 (analyzer) |
| Functional Safety | SIL2 compliant |
| Dimensions | 495 × 368 × 160 mm |
| Weight | 14.6 kg (32.2 lbs) |
| Power Supply | 24 VDC, 20 W (optional 120–220 VAC adapter) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BQHL-II (Dual-Channel) / BQHL-IV (Quad-Channel) |
| Pricing | Available Upon Request |
| Flow Rate | 300–600 mL/min |
| Flow Accuracy | ≤ ±3% |
| Sampling Volume Range | 0.1–50 L |
| Operating Temperature | −15°C to +45°C |
| Relative Humidity | ≤95% RH |
| Sound Pressure Level | ≤40 dB(A) |
| Battery Runtime | ≥8 hours (fully charged) |
| Charging Input | AC 220 V, 50 Hz |
| Charge Time | ≤4 hours |
| Dimensions (L×W×H) | 277 × 200 × 275 mm |
| Display | Backlit LCD |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | GC-2020 |
| Pricing | Upon Request |
| Detector Type | Photoionization Detector (PID), 10.6 eV |
| Measurement Range | 0–50 ppm (C₂H₄) |
| Column Configuration | Dual packed columns with backflush capability |
| Carrier Gas | Nitrogen (N₂), regulated flow control |
| Sample Introduction | Six-port multi-position valve with 1 mL sample loop |
| Cycle Time | 420 s typical |
| Data Storage | >2 GB internal flash memory |
| Display Interface | 7-inch capacitive touchscreen LCD (1024 × 600) |
| Rack Mount | 19-inch, 4 HU |
| Analog Output | 4–20 mA / 0–10 V (isolated) |
| Digital Interface | RS-232/RS-485 serial, parallel I/O for PLC integration |
| Auto-Diagnostics | Built-in system self-test with event logging |
| Standby Mode | Low-power operational state with wake-on-trigger capability |
| Compliance | Designed per IEC 61000-6-3 (EMC), EN 61010-1 (Safety), compatible with GLP/GMP data integrity requirements |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GXH-3011A |
| Instrument Type | Portable |
| Detection Target | Single-component (CO only) |
| Measurement Range | 0–50 ppm |
| Repeatability | ≤1% F.S. |
| Resolution | 0.1 ppm |
| Response Time (t₀–t₉₀) | ≤30 s |
| Zero Drift | ≤±2% F.S./4 h |
| Span Drift | ≤±2% F.S./4 h |
| Linearity Error | ≤±2% F.S. |
| Power Supply | AC 220 V (±10%) or rechargeable Li-ion battery |
| Dimensions | 245 × 190 × 85 mm |
| Weight | ≤3 kg |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer | AMETEK Arizona |
| Type | Online Fixed-Station Monitor |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | ≤60 s |
| Measurement Accuracy | ±0.001 mg/m³ |
| Measurement Range | 0.003–0.999 mg/m³ |
| Sensor Technology | Gold Film Amalgamation |
| Environmental Rating | IP65 Enclosure |
| Operating Temperature | –20 °C to +50 °C |
| Data Output | Modbus RTU/TCP, Ethernet, Optional 4G LTE |
| Alarm Outputs | Relay + Email/SMS Notification |
| Compliance | OSHA PEL (0.1 mg/m³), NIOSH REL (0.05 mg/m³), ACGIH TLV (0.025 mg/m³), MSHA Standards |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J405 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 2 seconds |
| Measurement Accuracy | ±0.01 µg/m³ (±0.00001 mg/m³) |
| Measurement Range | 0.5–999 µg/m³ |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | J505 |
| Instrument Type | Portable |
| Target Gas | Elemental Mercury Vapor (Hg⁰) |
| Response Time | 8 s (Search Mode) |
| Measurement Accuracy | ±15% at 0.3 µg/m³ |
| Measurement Range | 0.05 µg/m³ to 500 µg/m³ |
| Brand | LANScientific |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | AOA Series |
| Pricing | Upon Request |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MATRIX II-MG |
| Detection Scope | Simultaneous Quantification of Major, Minor, and Trace Gaseous Impurities (ppb to % v/v) |
| Optical Path Length Options | 10 cm – 26 m (Heated Up to >180 °C for Condensable Gases) |
| Compliance | Designed for ISO 14644-8, ASTM D7538, IEC 62409, and GLP/GMP-Ready Data Integrity Architecture |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | MGA10-GP |
| Measurement Principle | Mid-Infrared Quantum Cascade Laser Absorption Spectroscopy (QCLAS) |
| Simultaneous Target Gases | CH₄, CO, CO₂, SO₂, NH₃, N₂O, NO, NO₂, H₂O, O₃, COS, HCHO, HONO |
| Measurement Frequency | 1 Hz or 10 Hz (user-selectable) |
| Detection Limit | Sub-ppb to low-ppb range for most analytes |
| Interference Resistance | High specificity due to narrow-linewidth QCL emission and spectral fingerprint matching |
| Operating Environments | Laboratory, mobile platforms (aircraft, vehicle, ship), and unattended ground stations |
| Compliance | Designed to support ISO 14064-1/2, EPA Method TO-15 & ASTM D6348, and GLP/GMP-aligned data integrity workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | OMEGA 5 |
| Principle | Infrared Absorption Spectroscopy (FTIR) |
| Type | Online, Real-time |
| Response Time | <1 s |
| Detection Range | ppb to 100% |
| Sample Compatibility | >300 gas compounds |
| Gas Cell | 5 m multipass reflective cell with nickel-plated body and gold-coated mirrors |
| Interferometer | RockSolid™ permanent alignment |
| Detector | Thermoelectrically cooled MCT |
| Light Source | CenterGlow™ broadband IR source |
| Software | OPUS GA v8.x with spectral library and nonlinear fitting engine |
| Compliance | ASTM D6348, ISO 12039, USP <1227>, GLP/GMP-ready audit trail |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | BS-B2/H2 |
| Pricing | Available Upon Request |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | BS-H2 |
| Quotation | USD 920 (FOB Beijing) |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Gas Sampler |
| Instrument Configuration | Dual-Independent Sampling Channels |
| Flow Range | 100–500 sccm |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | ≤±1% FS |
| Flowmeter Accuracy | ±2.5% FS |
| Service Life Under Max Load & Resistance | 5–10 years |
| Continuous Operation Duration at Max Flow & Backpressure | 2–8 h |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | C90M |
| Price | Upon Request |
| Sampling Principle | Reverse Cyclonic Separation |
| Flow Rate | 16.6 LPM |
| Sample Collection Vessel | 1.5 mL Centrifuge Tube |
| Collection Efficiency | ≥90% for particles <1 µm, 19.9% of total collected particles <2.5 µm |
| Weight | 4.6 kg |
| Dimensions | 17 × 22 × 33 cm |
| Power Supply | Rechargeable NiCd Battery (20 LPM capacity), 120/240 VAC auto-switching charger |
| Timer Range | Up to 99 minutes with audible end-of-cycle alarm |
| Operating Noise Level | Near-silent turbine fan |
| Material | Precision-machined aerospace-grade aluminum alloy, natural anodized for corrosion resistance |
| Inlet Configuration | Standard 9 × 3 mm vertical orifice |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Model | C90Ma |
| Sampling Principle | Reverse-Flow Cyclonic Separation |
| Flow Rate | 16.5 LPM |
| Sample Collection Vessel | 1.5 mL Eppendorf Tubes |
| Power Supply | Rechargeable NiCd Battery (120/240 VAC Charging) |
| Compliance | Designed for GLP-compliant environmental microbiology workflows |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Model | HIRST |
| Sampling Principle | Single-Stage Slit Impaction |
| Flow Rate | 10 L/min (0.35 CFM) |
| Sampling Area | 0.89 m² (radius 53 cm) |
| Sampling Duration | 7 days (or configurable for 24 h) |
| Cut-Off Diameter (D₅₀) | 5.2 µm |
| Drum Linear Speed | 2 mm/h |
| Drive Mechanism | Precision 7-Jewel Clockwork Movement |
| Slit Aperture | 2 mm × 14 mm |
| Tape | Melinex® Transparent Polyester Adhesive Tape (Grade 200) |
| Power Supply | 220–240 V, 50 Hz or 110 V, 60 Hz |
| Optional Battery Operation | 12 V DC |
| Net Weight | 16 kg |
| Gross Weight | 30 kg |
| Packaging Dimensions | 57 × 65 × 65 cm |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Miniature Air Sampler |
| Price | Upon Request |
| Sampling Flow Rate | 10 LPM |
| Slide Dimensions | 76 × 26 mm (3 × 1 in) |
| Cut-Off Diameter (D₅₀) | 2.5 µm |
| Height | 115 mm |
| Diameter | 88 mm |
| Weight | 590 g |
| Power Options | 110 V / 60 Hz, 230 V / 50 Hz, or 700 mAh NiCd rechargeable battery |
| Timer Range | 1–9 min (continuous mode at “0”) |
| Motor | Precision Swiss DC motor with precious-metal brush gear |
| Compliance | Designed for ISO 14644-1 classified environments, compatible with ASTM D6305 and EN 13098 for viable and non-viable particle sampling |
| Brand | Burkard |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Not Specified |
| Price | Upon Request |
| Sampling Flow Rate | 20 L/min |
| Stage 1 Cut-Off Size | >10 µm |
| Stage 2 Cut-Off Size | 10–4 µm |
| Stage 3 Cut-Off Size | <4 µm |
| Collection Liquid Volume per Stage | 6 mL |
| Vacuum Hose Port Diameter | 6 mm |
| Dimensions (L×W×H) | 115 × 100 × 145 mm |
| Net Weight | 670 g |
| Brand | Burkard |
|---|---|
| Origin | UK |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PASA/B (Battery) / PASA/M (Mains) |
| Price | Upon Request |
| Sampling Flow Rate | 10–20 LPM |
| Height | 148 mm |
| Collection Efficiency D₅₀ | ~2.56 µm |
| Petri Dish Diameter | 90 mm |
| Overall Diameter | 114 mm |
| Weight | 690 g |
| Power Options | Rechargeable 6 V NiCd (700 mAh), or 110 V / 60 Hz & 240 V / 50 Hz AC adapters |
| Timer Range | 1–9 min (or continuous at “0”) |
| Inlet Configurations | Open Grille Cap or Conical Pre-sterilization Cap |
| Operating Duration (Battery) | 3–4 hours continuous |
| Motor | Swiss-sourced brushed DC gearmotor with precious-metal brushes |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS20X |
| Price | Upon Request |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FS24X |
| Pricing | Upon Request |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GasAlert MCXL-4 |
| Type | Portable Multigas Detector |
| Response Time | <15 s (T90) |
| Detection Gases | H₂S (0–100 ppm), CO (0–500 ppm), O₂ (0–30.0% vol), Combustible Gas (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (Combustible) |
| Operating Temperature | –20 to +58 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| IP Rating | IP66/IP67 |
| Battery Life | Up to 12 h (typical, Li-polymer) |
| Charging Time | <3 h |
| Alarm Types | Visual (bright LED strobe), Audible (95 dB), Vibration |
| Compliance | CSA/UL Class I Div 1, ATEX II 1G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga, UKCA, RoHS, REACH |
| Calibration | Auto-bump test & calibration compatible with BW MicroDock II system |
| Data Logging | Internal event logging (alarm triggers, calibration events, bump tests, faults) |
| Display | Backlit LCD with real-time gas concentration readouts |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GAXT-Series |
| Instrument Type | Portable |
| Detectable Gases | H₂S, SO₂, HCN, CO, NH₃, Cl₂, PH₃, O₃, NO, NO₂, ClO₂, ETO, O₂ |
| Response Time | ≤15 s |
| Measurement Accuracy | ±0.1 ppm |
| Measurement Ranges | 0–1 ppm, 0–50 ppm, 0–100 ppm, 0–1000 ppm |
| Display | Backlit LCD with real-time concentration readout |
| Alarm | Dual-mode (audible ≥95 dB @ 30 cm, visual high-intensity LED strobe), optional vibration alert |
| Calibration | Auto-zero and span calibration |
| Battery Life | Up to 2 years (typical usage, alkaline or rechargeable options) |
| Enclosure Rating | IP66/IP67 |
| Operating Temperature | –20 °C to +50 °C |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UL 913 Class I, Div 1, Groups A–D, T4, CSA C22.2 No. 152, EN 60079-0, EN 60079-11, EN 60079-26 |
| Data Logging | Internal memory for >100,000 timestamped events (gas readings, alarms, calibrations, faults) |
| User Interface | Multilingual (English, French, German, Spanish, Portuguese) with password-protected configuration |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | GAMAX-XT4 |
| Type | Portable Pumped Multigas Detector |
| Response Time | <15 s (typical, per sensor) |
| Repeatability | ±2% of reading (H₂S, CO, O₂, combustible gas) |
| Gas Channels | H₂S (0–200 ppm), CO (0–1000 ppm), O₂ (0–30.0% vol), Combustible (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (combustible) |
| Dimensions | 13.1 × 7.0 × 5.2 cm |
| Weight | 316 g |
| Operating Temp. | –20 to 50 °C |
| Humidity | 10–95% RH (non-condensing) |
| IP Rating | IP66/IP67 |
| Certifications | ATEX II 1G Ga Ex ia IIC T4, IECEx Ga Ex ia IIC T4, CSA Class I, Div. 1, Groups A, B, C, D |
| Alarm Types | Visual (LED strobe), Audible (95 dB), Vibration |
| Pump Draw Distance | Up to 20 m |
| Data Logging | Internal event & sample logging with time stamp |
| Compliance | Meets IEC 61508 SIL 2 (for safety functions), EN 45544-1, EN 45544-2, and supports GLP/GMP audit trails via Fleet Manager II |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | XT-4 |
| Instrument Type | Portable |
| Detectable Gases | H₂S, CO, O₂, LEL (configurable 1–4 gas combinations) |
| Response Time | ≤30 s |
| Measurement Accuracy | ±1 ppm (H₂S), ±1 ppm (CO), ±0.1% vol (O₂), ±1% LEL (combustibles), ±0.1% v/v (optional hydrocarbons) |
| Measurement Ranges | 0–100 ppm (H₂S), 0–500 ppm (CO), 0–30.0% vol (O₂), 0–100% LEL, 0–5.0% v/v (hydrocarbons) |
| Pump Type | Integrated diaphragm pump with SmartSample™ technology |
| IP Rating | IP66/IP67 |
| Operating Temperature | –20 °C to +50 °C |
| Battery Life | Up to 18 hours (alkaline) / 24+ hours (rechargeable Li-ion) |
| Compliance | ATEX II 2G Ex ib IIC T4 Gb, IECEx Ex ib IIC T4 Gb, UL 913 Class I, Div 1, Groups A–D, CSA C22.2 No. 152, EN 60079-0/-11, EN 61000-6-2/-6-3, RoHS, REACH |