| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | QT Series |
| Instrument Type | Portable |
| Detectable Gases | H₂S, CO, O₂, LEL (Combustible Gas) |
| Response Time | ≤15 s |
| Measurement Accuracy | ±1 ppm (for H₂S and CO), ±0.1% vol (for O₂), ±1% LEL (for combustibles) |
| Measurement Ranges | 0–200 ppm (H₂S), 0–1000 ppm (CO), 0–30.0% vol (O₂), 0–100% LEL |
| Power Options | Rechargeable Li-ion battery pack or 3× AA alkaline batteries |
| Compliance | CSA/UL Class I, Div 1 |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | QT |
| Type | Portable Multigas Detector |
| Response Time | <15 s (T90) |
| Detection Gases | H₂S (0–200 ppm), CO (0–1000 ppm), O₂ (0–30.0% vol), Combustible Gas (0–100% LEL or 0–5.0% v/v) |
| Resolution | 1 ppm (H₂S, CO), 0.1% vol (O₂), 1% LEL / 0.1% v/v (Combustible) |
| Operating Temperature | −20 to +50 °C |
| Humidity Range | 10–95% RH (non-condensing) |
| Dimensions | 13.0 × 8.1 × 4.7 cm |
| Weight | 316 g (rechargeable battery), 338 g (alkaline) |
| Alarm Types | Visual (6 red LEDs, IntelliFlash beacon), Vibration, Audible (95 dB @ 30 cm) |
| Battery Life | 14 h (alkaline, 20–50 °C), 20 h (rechargeable, 20–50 °C), 18 h (rechargeable, −20–0 °C) |
| Compliance | CSA/UL Class I Div 1, ATEX II 1G Ex ia IIC T4 Ga, IECEx ia IIC T4 Ga, UKCA, RoHS, REACH |
| Data Logging | Internal event and exposure history (≥5,000 records), time-stamped, with user-accessible USB export |
| Calibration | Auto-bump test & calibration via MicroDock II docking station |
| Cross-Sensitivity Mitigation | Enhanced CO & H₂S sensor algorithms for reduced interference from methanol, ethanol, and other common VOCs |
| Language Support | English, French, German, Spanish, Portuguese |
| Brand | BW |
|---|---|
| Origin | Canada |
| Model | M5 Series |
| Instrument Principle | Electrochemical Sensing |
| Type | Portable |
| Response Time | ≤15 s |
| Detectable Gases | H₂S, CO, O₂, SO₂, LEL (Combustible Gases), NH₃, NO₂, Cl₂, HCN, PH₃, O₃, ClO₂, VOCs (PID option), CO₂ (NDIR option) |
| Compliance | CE, ATEX, UL, IECEx, RoHS |
| Brand | BW |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MCXL |
| Instrument Type | Portable |
| Detectable Gases | H₂S, CO, O₂, Combustible Gas (LEL) |
| Response Time | ≤15 s |
| Measurement Accuracy | ±1 ppm (H₂S), ±1 ppm (CO), ±0.1% vol (O₂), ±0.01% vol / ±0.001% vol (Combustible, depending on calibration gas) |
| Measurement Ranges | 0–100 ppm (H₂S), 0–500 ppm (CO), 0–30.0% vol (O₂), 0–100% LEL (Combustible), 0–5.0% vol (Combustible, v/v) |
| Ingress Protection | IP68 (submersible to 1.2 m for 45 min) |
| Battery Life | Up to 18 hours continuous operation |
| Operating Temperature | –20 °C to +50 °C |
| Certifications | ATEX, IECEx, UL, CSA, MSHA (model-specific) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GasAlertMicro 4 |
| Pricing | Available Upon Request |
| Brand | BJBY (Beijing Baoyun) |
|---|---|
| Model | BY-200-CO2 |
| Type | Portable Gas Analyzer |
| Detection Principle | NDIR for CO₂ |
| CO₂ Range | 0–10,000 ppm |
| CO₂ Resolution | 1 ppm |
| CO₂ Accuracy | ±(40 + 3% of reading) ppm |
| HCHO Range | 0.00–5.00 mg/m³ |
| HCHO Resolution | 0.01 mg/m³ |
| HCHO Accuracy | ±5% |
| Dimensions (Analyzer) | 165 × 80 × 30 mm |
| Sensor Module Size | 123 × 45 × 15 mm |
| Display | Color TFT LCD |
| Power | Replaceable alkaline batteries |
| Data Connectivity | Bluetooth-enabled smartphone app with cloud upload capability |
| Data Logging | Internal storage with query function |
| Compliance | Designed for indoor air quality (IAQ) assessment per ISO 16814, ASHRAE Standard 62.1, and GB/T 18883–2022 (China IAQ guideline) |
| Brand | Beijing Baoyun (BJBY) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BY-PM10 |
| Pricing | Available Upon Request |
| Length Options | 2-Section (1.2 m), 3-Section (1.8 m) |
| Brand | California Instruments |
|---|---|
| Origin | USA |
| Model | 700 |
| Spectral Resolution | 0.5 cm⁻¹ |
| Spectral Range | 305–7500 cm⁻¹ |
| Detector | MCT-A |
| Interferometer | RockSolid™ Cube Corner Retroreflector Design |
| Sample Cell Temperature | 50 °C or 191 °C (heated, 316 stainless steel) |
| Optical Path Length | 10.2 m |
| Data Output Rate | 1 Hz |
| Response Time | <1 s to 5 min (application-dependent) |
| Detection Range | ppb to % v/v |
| Sample Flow Rate | 0.2–5 LPM |
| Dimensions | 26.7 × 48.3 × 71.1 cm (H×W×D) |
| Weight | 57.6 kg |
| Environmental Operating Range | 5–40 °C, <90% RH (non-condensing) |
| Power Supply | 230 VAC / 50 Hz |
| Window Material | ZnSe (standard), optional alternatives available |
| Sealing | Parafluor O-rings |
| Inlet/Outlet Fittings | 3/8″ tubing |
| Purge Fitting | 1/4″ Swagelok® compression |
| Brand | Casella |
|---|---|
| Origin | United Kingdom |
| Model | CEL-712 |
| Measurement Principle | Forward Light Scattering (880 nm Infrared) |
| Safety Rating | Intrinsically Safe (ATEX/IECEx Certified) |
| Measurement Range | 0.001 mg/m³ to 250 g/m³ |
| Resolution | 0.001 mg/m³ |
| Operating Temperature | 0–55 °C (non-condensing) |
| Zero Drift Stability | <2 µg/m³/°C |
| Data Storage Capacity | 86,000 data points |
| Sampling Interval | Adjustable from 1 second to 60 minutes |
| Display | TFT color LCD with real-time trend graphing |
| Power Supply | 3 × AA NiCd rechargeable or alkaline batteries (13 h typical operation) |
| Weight | 0.6 kg (including batteries) |
| Dimensions | 172 × 72 × 33 mm |
| Analog Output | 0–2.5 V DC |
| Communication Interface | Mini-B USB |
| Compliance | Meets ISO 7706:2022 (ambient aerosol monitoring), EN 481 (inhalable fraction), EN 13205 (PM₁₀ and PM₂.₅ sampling conventions), ATEX Directive 2014/34/EU (Category 2G, Zone 1) |
| Brand | Casella |
|---|---|
| Origin | United Kingdom |
| Model | GUARDIAN2 |
| Dust Detection Sensitivity | 1 µg/m³ |
| Zero Stability | ±2 µg/m³ |
| Particle Size Selectors | TSP, PM₁₀, PM₂.₅ |
| Noise Accuracy | IEC 61672-1 Class 1 |
| Noise Metrics | L<sub>Aeq</sub>, L<sub>Amax</sub>, L<sub>A10%</sub>, L<sub>A90%</sub> |
| Noise Range | 20–140 dB RMS |
| Included Acoustic Calibrator | CEL-120/1 |
| Vibration Sensor | Triaxial Geophone |
| Vibration Frequency Range | 2–250 Hz |
| Vibration Resolution | 0.01 mm/s |
| Wind Speed Range | 0–60 m/s |
| Wind Speed Accuracy | ±2% |
| Wind Speed Resolution | 0.01 m/s |
| Wind Direction Range | 0–359° |
| Wind Direction Accuracy | ±3% |
| Wind Direction Resolution | 0.1° |
| VOC Range | 0–6000 ppm |
| VOC Resolution | 0.1 ppm |
| Enclosure Rating | IP65 |
| Operating Humidity | 5–100% RH |
| Data Storage | Internal Flash Memory |
| Communication | GPRS |
| Power Supply | 220–240 VAC or Hybrid Solar/Wind |
| Mounting | Wall or Pole (50 mm diameter) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TUFF |
| Price | Upon Request |
| Brand | CASP |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | AGHJ-I-LIDAR(HPL) |
| Price Range | USD 140,000 – 280,000 |
| Laser Source | Nd:YAG / Solid-State Laser Diode |
| Detector | High-Sensitivity, Low-Noise Photomultiplier Tube (PMT) |
| Operating Wavelength | 532 nm |
| Maximum Detection Altitude | 20 km |
| Pulse Repetition Rate | 2–2.5 kHz |
| Brand | Catalytic |
|---|---|
| Origin | Germany |
| Model | CS015 |
| Operating Temperature | 350 °C |
| Standard Flow Rate | 1.5 L/min (STP) |
| Oxidation Efficiency | ≥99.9% for n-tetradecane (PMP-compliant) |
| Power Supply | 100–240 V AC, 50/60 Hz, 210 W |
| Communication Interface | USB with MODBUS protocol |
| Inlet/Outlet Diameter | 6 mm |
| Exit Temperature | Ambient + 25 °C |
| Particle Loss Optimization | Minimized for solid particles ≥50 nm at 1 mg/m³ mass concentration |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CCHZ-1000 |
| Pricing | Available Upon Request |
| Dust Measurement Range | 0–1000 mg/m³ |
| Measurement Accuracy | < ±10% |
| Stability Relative Error | ±2.5% |
| Sampling Flow Rate | 2 L/min |
| Flow Rate Accuracy | < ±2.5% |
| Intrinsic Safety Rating | ibdI (150 °C) |
| Compliance | MT163–1997 |
| Brand | 1124123/13213112 |
|---|---|
| Origin | Jiangsu, China |
| Model | CCHZ-1000 |
| Measurement Principle | Light Scattering |
| Safety Rating | Exib I (150 °C) Intrinsically Safe |
| Measurement Range | 0–1000 mg/m³ |
| Resolution | 0.001 mg/m³ |
| Accuracy | ±10% |
| Relative Stability Error | ±2.5% |
| Sampling Flow Rate | 2.0 L/min (±2.5%) |
| Data Storage Capacity | 50 test records |
| Dimensions | 220 × 150 × 82 mm |
| Weight | 1.9 kg |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | CD4(A) |
| Price | Upon Request |
| Gas Detection Capabilities | O₂, NH₃, NO, H₂ |
| Detection Principle | Potentiostatic Electrolytic Sensors |
| Measurement Ranges | NO (0–250 ppm), O₂ (0.0–30.0 %vol), H₂ (0–1000 ppm), NH₃ (0.0–100 ppm) |
| Accuracy | NO (±10% of true value, 0–250 ppm), O₂ (±5% vol for 0.0–5.0%, ±3% FS for >5.0–30.0%), H₂ (±4 ppm for 0–100 ppm |
| Alarm Accuracy | NO (±1 ppm at 10 ppm setpoint), O₂ (±0.3% vol at 15.0% vol setpoint), H₂ (±1 ppm at 50 ppm setpoint), NH₃ (±1 ppm at 10 ppm setpoint) |
| Response Time (200 mL/min flow) | O₂ ≤35 s, NO ≤45 s, NH₃ ≤60 s, H₂ ≤60 s |
| Audible Alarm Level | ≥75 dB(A) at 1 m |
| Visual Alarm Visibility | ≥20 m in darkness |
| Battery Life | >10 h continuous operation |
| Dimensions & Weight | 135 × 60 × 20 mm / 200 g |
| Power Supply | Rechargeable Li-ion, nominal 7.2 V, max open-circuit voltage 8.0 V, max short-circuit current 2.5 A, operating current ≤120 mA |
| Ingress Protection | IP55 |
| Explosion Protection | Exib I Mb |
| Operating Temperature | −20 to +55 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Housing Material | Antistatic ABS + PC soft-touch overmold |
| Sensor Lifespan | >2 years (O₂, NH₃, NO, H₂) |
| Certifications | MA (Mine Safety Mark), CNEx explosion-proof certification, third-party calibration and verification reports |
| Optional Features | Configurable data logging interval, USB interface for data download and report generation |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | CD4(B) |
| Pricing | Available Upon Request |
| Detection Gases | CO₂, CO, H₂S, SO₂ |
| Detection Principles | Non-Dispersive Infrared (NDIR) for CO₂ |
| Measurement Ranges | CO: 0–1000 ppm |
| SO₂ | 0.0–100.0 ppm |
| H₂S | 0.0–100.0 ppm |
| CO₂ | 0.00–5.00% vol |
| Accuracy | CO: ±2 ppm (0–20 ppm), ±4 ppm (20–100 ppm), ±5% FS (100–500 ppm), ±6% FS (500–1000 ppm) |
| SO₂ | ±5.0 ppm (0–50 ppm), ±10% FS (50–100 ppm) |
| H₂S | ±3 ppm (0–49 ppm), ±10% FS (50–100 ppm) |
| CO₂ | ±0.10% (0–0.50%), ±(0.05% + 5% of reading) (0.50–5.00%) |
| Alarm Accuracy | CO: ±1 ppm at 25 ppm |
| SO₂ | ±0.2 ppm at 10 ppm |
| H₂S | ±1 ppm at 10 ppm |
| CO₂ | ±0.05% at 1.00% |
| Response Time (200 mL/min) | ≤45 s (CO, SO₂, H₂S), ≤60 s (CO₂) |
| Audible Alarm | ≥75 dB(A) at 1 m |
| Visual Alarm | Blue LED strobe visible ≥20 m in darkness |
| Vibration Alert | Integrated haptic feedback |
| Display | 2.4″ TFT color LCD with bilingual (English/Chinese) UI |
| Data Logging | Optional internal storage with configurable interval |
| Interface | USB 2.0 for data export and firmware update |
| Battery | Rechargeable Li-ion, 7.2 V nominal, ≤120 mA avg. current draw |
| Runtime | >10 h continuous operation |
| Enclosure | ABS+PC dual-material impact- and ESD-resistant housing |
| Dimensions & Weight | 135 × 60 × 20 mm / 200 g |
| Environmental Rating | IP55 |
| Hazardous Area Certification | Exib I Mb (for use in coal mine methane environments) |
| Operating Temp. | −20 °C to +55 °C |
| Operating Humidity | 0–95% RH non-condensing |
| Sensor Lifespan | CO₂: >5 years |
| CO/H₂S/SO₂ | >2 years each |
| Regulatory Compliance | MA (Mine Safety Mark), CNEx explosion-proof certification, CNAS-accredited test reports |
| Brand | — |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | P-51 |
| Pricing | Upon Request |
| Detection Principle | Colorimetric Gas Detection Tube Method |
| Compliance | Designed to meet CDC-recommended field screening protocols for emergency response and occupational health assessments |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CE318 |
| Pricing | Available Upon Request |
| Brand | Cerex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Open Path-FTIR |
| Detection Principle | Fourier Transform Infrared (FTIR) Spectroscopy |
| Instrument Type | Online Continuous Emission Monitor |
| Typical Configuration | Multi-Gas VOC & HAPs Analyzer |
| Detection Range | 0–100 ppb (gas-dependent) |
| Spectral Resolution | 0.05–0.5 cm⁻¹ (not nm — corrected per FTIR standard) |
| Accuracy | ±1–3% of reading |
| Response Time | 1 Hz (1 spectrum per second) |
| Detector | Liquid-Nitrogen-Free Stirling-Cooled MCT |
| Cooling System | Integrated Stirling Cryocooler (MTBF ≥20,000 hrs) |
| Consumables | IR Source & Cryocooler (replacement interval: every 3 years) |
| Gas Coverage | >385 gases, including 100+ EPA-listed Hazardous Air Pollutants (HAPs), acids, aldehydes, aromatics, CFCs, greenhouse gases, hydrocarbons, and combustion byproducts |
| Brand | Cerex |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Open Path UV-DOAS |
| Detection Principle | Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Instrument Type | Online Continuous Emission Monitor |
| Typical Configuration | Multi-Component VOC & Inorganic Gas Analyzer |
| Detection Range | 0.1–10 ppb (gas-dependent) |
| Resolution | 0.1 ppb |
| Accuracy | ±0.1% of full scale |
| Response Time | <1 s |
| Optical Path Length | 0–2000 m |
| Compliance | ASTM D6348, ISO 12039, EN 15267-3 (configurable), US EPA Method TO-14/TO-15 compatible (with optional calibration gas manifold) |
| Brand | CerexMS |
|---|---|
| Origin | USA |
| Model Variants | Mini Hound-FR (8.5 m optical path), Hound-FR (17 m optical path), Micro Hound-FR (2 m optical path) |
| Portability | Portable |
| Response Time | < 1 s |
| Detection Principle | Ultraviolet Differential Optical Absorption Spectroscopy (UV-DOAS) |
| Detection Capability | Simultaneous real-time quantification of up to 15 gas species |
| Detection Limit | Sub-ppb level for key analytes (e.g., SO₂, NO₂, O₃, benzene, toluene, formaldehyde) |
| Integrated Components | Rechargeable battery pack, high-resolution UV spectrometer (200–400 nm), 15 CFM sampling pump, sub-micron particulate filter |
| Regulatory Alignment | Designed to support EPA Method TO-15 / TO-14A compliance workflows, compatible with ISO 12039 and ASTM D6348 validation frameworks |
| Brand | CerexMS |
|---|---|
| Origin | USA |
| Model | Shepherd |
| Instrument Principle | Infrared Absorption Spectroscopy (FTIR) |
| Type | Portable |
| Response Time | <1 s |
| Repeatability | High for all IR-active species |
| Detection Range | Sub-ppb to % v/v |
| Gas Library | 385+ compounds (including >100 HAPs) |
| Optical Path Length | 20 m (fixed, multipass) |
| Detector | Liquid-nitrogen-free cryogenically cooled MCT |
| Data Output | Raw interferograms, calibrated spectra, concentration time-series, CSV export |
| Compliance | Designed for EPA Method 320 / ASTM D6348 / ISO 12039 alignment |
| Software | CMS Continuous Monitoring Software (Windows Embedded, touchscreen UI) |
| Connectivity | Wi-Fi, Ethernet, USB |
| Alarm Options | Visual, audible, email, remote notification |
| Calibration | Built-in reference cell + user-definable multi-point calibration |
| Maintenance | Two consumables only — IR source and thermoelectric cooler compressor |
| Brand | CHINYEE |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 5-100-1 |
| Instrument Type | Online Analyzer |
| Typical Configuration | TVOC Analyzer |
| Detection Range | 0–1000 ppm |
| Resolution | 0.1 ppm |
| Accuracy | ±5% of reading |
| Response Time | <60 s |
| Detection Principle | Flame Ionization Detection (FID) |
| Sensitivity (CH₄) | ≤1 ppm full-scale |
| Detector Heating Zone Temperature | 190 °C |
| Carrier/Combustion Air Supply | Integrated zero-air generator |
| Measurement Ranges (selectable) | 0–10, 0–100, 0–1,000, 0–10,000, 0–100,000 ppm (as C₁ equivalent) |
| Brand | Chu Ding Technology |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (PRC) |
| Model | HAS-100B |
| Instrument Type | Handheld Air Sampling Pump |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0–10 L/min |
| Maximum Vacuum Pressure | >26 kPa |
| Flow Stability | <5% deviation over 1 h |
| Flowmeter Accuracy | ±2.5% FS |
| Service Life at Max Flow & Backpressure | >500 h |
| Continuous Operation at Max Flow & Backpressure | 0–30 min |
| Power Source | Rechargeable Ni-MH Battery |
| Display | Dot-Matrix LCD with Real-Time Flow & Battery Status |
| Auto-Power Management | Backlight Off After 30 s Inactivity |
| Compliance | Designed per GB/T 18883–2002 and Anderson Cascade Impaction Principle for Viable Airborne Microorganism Enumeration |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE318 |
| Instrument Type | Aerosol Optical Depth (AOD) & Sky Radiance Spectroradiometer |
| Standard Spectral Channels | 340, 380, 440, 500, 675, 870, 936, 1020, 1640 nm (FWHM ≤ 10 nm) |
| Field of View | 1.3° (full width at half maximum) |
| Detector Configuration | Enhanced silicon photodiode (direct sun), silicon photodiode (sky radiance) |
| Solar Tracking Accuracy | < 0.1° (dual-axis stepper motor + quadrant detector fine adjustment) |
| Operating Temperature Range | −30 °C to +60 °C |
| Power Supply | Internal battery (optical head), external battery (motor drive) |
| Data Interfaces | RS-232 serial, USB, optional Wi-Fi/3G/Geostationary Satellite (Meteosat/GOES/GMS) telemetry |
| Environmental Protection | Automatic rain shutdown via integrated hygrometer |
| Brand | CIMEL |
|---|---|
| Origin | France |
| Model | CE370-2 |
| Eye-Safe Laser Pulse Energy | 8–12 µJ |
| Laser Wavelength | 532 nm |
| Pulse Repetition Rate | 5 kHz |
| Pulse Width | <12 ns |
| Telescope Type | Galilean |
| Aperture Diameter | 200 mm |
| Effective Focal Length | 900 mm |
| Field Stop | Double |
| Total Field of View (FOV) | 55 µrad (standard fiber) / 55/110 µrad (enhanced fiber) |
| Detector | Si APD with 55% Quantum Efficiency |
| Filter Bandwidth | 0.2 nm |
| Spatial Resolution | 15 m |
| Maximum Detection Range | Up to 30 km (atmosphere-dependent) |
| Range Gates | 2048 |
| Data Acquisition Mode | Photon Counting |
| Maximum Counting Rate | 20 Mc/s |
| Operating Temperature | –10 °C to +40 °C |
| Power Supply | 100/115/230 VAC, ≤500 W |
| Weight | 35 kg |
| Enclosure | 6U Rack-mounted Electronics + Telescope (Ø220 mm × 500 mm) |
| Fiber Interconnect | 10 m optical fiber |
| Optional Dual-Axis Scanner | Azimuth –180° to +180°, Zenith 0° to 90°, Positional Accuracy ±3′ |
| Brand | Cimel |
|---|---|
| Origin | France |
| Model | CE376 |
| Laser Sources | Frequency-doubled Nd:YAG (532 nm), Pulsed Laser Diode (<850 nm) |
| Detectors | APD with QE 55% / 70% |
| Operating Wavelengths | 532 nm (green) and <850 nm (NIR) |
| Maximum Detection Altitude | 13 km |
| Pulse Repetition Rate | 5000 Hz |
| Brand | CMI (California Measurements, Inc.) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AFS |
| Pricing | Available Upon Request |
| UV Excitation Source | 280 ±20/−40 nm |
| Fluorescence Channel 1 (UV) | 330–650 nm |
| Fluorescence Channel 2 (Visible) | 420–650 nm |
| Sample Volume per Measurement | 2.5 cm³ |
| Dimensions (L×W×H) | 30 × 28 × 24 cm |
| Weight | 5.3 kg (11.3 lbs) |
| Power Supply | 90–260 VAC, 47–63 Hz |
| Operating Temperature | +5 to +30 °C |
| Relative Humidity Range | 0–95 % RH |