Gas Detector
Filter
Showing 31–60 of 833 results
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 211 |
| Instrument Type | Portable |
| Measurement Range | ppm |
| LOD | 1 ppb |
| Response Time | 2 s |
| Zero Drift | <0.5 %/day, <3 %/year |
| Resolution | 0.1 ppb |
| Operating Temperature | 10–50 °C |
| Power Supply | 11–14 V DC or 120/240 V AC, 8 W |
| Dimensions | 43 × 37 × 14 cm |
| Weight | 6.5 kg (14.3 lbs) |
| Data Outputs | USB, RS-232, 0–2.5 V analog, optional 4–20 mA |
| Internal Memory | 16,333 records (scalable via USB flash drive) |
| Averaging Intervals | 10 s to 1 h |
| Units | ppb, ppm, pphm, µg/m³, mg/m³, mbar, torr, °C, K |
| T&P Correction | Yes |
| DewLine™ Humidity Compensation | Yes |
| Integrated Pump Lifetime | 20,000 hours |
| Flow Meter | Optional |
| Accessories | GPS module, heater kit, Bluetooth wireless telemetry |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 211 |
| Instrument Type | Portable |
| Measurement Range | ppm |
| Limit of Detection | 1 ppb |
| Response Time | 2 s |
| Zero Drift | <0.5 %/day, <3 %/year |
| Resolution | 0.1 ppb |
| Operating Temperature | 10–50 °C |
| Power Supply | 11–14 V DC or 120/240 V AC, 8 W |
| Dimensions | 43 × 37 × 14 cm |
| Weight | 6.5 kg (14.3 lb) |
| Data Outputs | USB, RS-232, 0–2.5 V analog, optional 4–20 mA |
| Internal Memory | 16,333 records (scalable via USB flash drive) |
| Pressure & Temperature Compensation | Yes |
| DewLine™ Humidity Compensation | Yes |
| Flow Meter | Optional |
| Built-in Pump Lifetime | 20,000 hours |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 306 |
| Instrument Type | Portable |
| Ozone Concentration Range | 0 ppbv and 30–1,000 ppbv |
| Limit of Detection | 0 ppbv |
| Response Time | ≤10 s (to 95% of step change) |
| Zero Drift | ±2 ppb/24 h |
| Resolution | 1 ppb |
| Output Flow Rate | 2.5 L/min |
| NIST-Traceable Calibration | Yes |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Model 306 OCS |
| Instrument Type | Portable |
| Measurement Range | 0–1,000 ppbv (selectable from 0, 30, 50, 100, 200, 500, 1000 ppbv) |
| Detection Limit | 0 ppbv (zero reference capability) |
| Response Time (t₉₅) | <35 s |
| Zero Drift | ≤1% of full scale per 24 h |
| Resolution | 2 ppbv |
| Ozone Generation Principle | Photolysis of O₂ at 185 nm |
| Total Flow Rate | 2.5 L/min (±5%) |
| Dimensions | 90 × 210 × 290 mm |
| Weight | 2.6 kg |
| Power Supply | 12 VDC or 100–240 VAC, 50/60 Hz, 18 W |
| NIST-Traceable Calibration | Yes |
| Environmental Independence | Controlled ozone mixing ratio unaffected by ambient temperature, pressure, or humidity |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 306 |
| Instrument Type | Portable |
| Measurement Range | 0 and 30–1000 ppb |
| Response Time | <30 s |
| Ozone Generation Method | Photolysis of O₂ at 185 nm |
| Accuracy | ±2 ppb or ±1% of reading (whichever is greater) |
| Flow Rate | ~3.0 L/min |
| Rise Time | <30 s (to 95% of target concentration) |
| Output Interface | RS-232 |
| Power Supply | 12 V DC or 100–240 V AC, 18 W |
| Dimensions | 9 × 21 × 29 cm |
| Weight | 2.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 405 |
| Detection Principle | UV Absorption Spectroscopy at 405 nm |
| Measurement Range | 0–10,000 ppb NO₂ |
| Resolution | 0.1 ppb |
| Accuracy | ±2.5 ppb or ±2.5% of reading (whichever is greater) |
| Detection Limit (2σ) | 3.5 ppb (60 s avg) |
| Response Time (100%) | 40 s (20 s avg) |
| Operating Temperature | 10–50 °C |
| Power Supply | 11–14 V DC or 100–240 V AC, 26 W |
| Dimensions | 43 × 37 × 14 cm (17″ × 14.5″ × 5.5″) |
| Weight | 8.4 kg (18.6 lb) |
| Data Output | USB, RS-232, 0–2.5 V analog, 4–20 mA analog |
| Internal Memory | 8,192 records |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 408 |
| NO Generation Method | Photolytic decomposition of N₂O at 185 nm |
| Output Concentration Range | 0 and 10–1000 ppb |
| Accuracy | ±3 ppb or ±3% of reading (whichever is greater) |
| Flow Rate | ~3.0 L/min |
| Rise Time | <30 s (to 95% of setpoint) |
| Operating Temperature | 0–40 °C |
| Power Supply | 12 V DC or 120/240 V AC, 21 W |
| Dimensions | 9.4 × 21.6 × 24.1 cm |
| Weight | 2.4 kg |
| Diagnostic Interface | RS-232 |
| Humidity-Matched Output | Yes |
| NIST-Traceable Calibration | Yes |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | 410 |
| Measurement Principle | Chemiluminescence-free ozone titration with UV absorption at 254 nm (NOzone™ Technology) |
| Range | 0–2 ppm NO |
| Detection Limit | <1.5 ppb or ±2% of reading, whichever is greater |
| Data Storage | 14,336 rows (e.g., 10-sec averages for ~1.4 days |
| Sampling Flow Rate | 1.0 L/min |
| Measurement Interval | Configurable (10 s, 1 min, 5 min, 1 hr) |
| Output Interfaces | RS-232 serial, 0–2.5 V analog, LCD display, optional microSD card logging |
| Dimensions | 33.7 × 20.0 × 13.3 cm |
| Weight | 8.3 kg (3.7 kg without portable case) |
| Optional Accessory | 401 NO₂ Converter for NOₓ and NO₂ measurement |
| Compliance | Designed for ambient air quality monitoring per EPA TO-15 and ISO 8573-1 referencing traceable gas standards |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of Setpoint | <30 s |
| Power | 12 V DC, 3.5 A max (42 Wh), or 100–240 V AC, 5 A |
| Dimensions (Rack-Mount) | 43 × 37 × 14 cm (17" × 14.5" × 5.5") |
| Weight | 7.0 kg (15.5 lb) |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −20–60 °C |
| Relative Humidity | 0–80% RH (non-condensing) |
| Altitude | 0–2000 m |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | Model 714 |
| NO₂ Range | 0–500 ppb |
| NO Range | 0–1000 ppb |
| O₃ Range | 0–500 ppb |
| Output Flow | 2.0–3.5 L/min (typ. 2.5–3.0 L/min) |
| Accuracy | ±2.0 ppb or ±2.0% of reading (whichever is greater) |
| Response Time to 95% of target concentration | <30 s |
| Power | 12 V DC / 120–240 V AC, 18 W (operational), 42 Wh (max during warm-up) |
| Dimensions (Rack-mount) | 43 cm × 37 cm × 14 cm (17″ × 14.5″ × 5.5″) |
| Weight | 7.0 kg (15.5 lb) |
| Programmable Sequences | Up to 99 stored methods, each with up to 15 steps (NO: up to 1000 ppb |
| NO₂/O₃ | up to 500 ppb) |
| Operating Temp | 0–40 °C |
| Storage Temp | −20–60 °C |
| RH | 0–80% non-condensing |
| Altitude | 0–2000 m |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | UV-106-W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm (g/m³, µg/mL, mg/L) |
| Detection Limit | 1 ppb (0.001 ppm) |
| Response Time | 20 s |
| Zero Drift | <0.05 ppm/month |
| Resolution | 0.1 ppm |
| Sampling Flow Rate | 12 mL/min |
| Operating Pressure | 0–50 psi (burst pressure >100 psi) |
| Power | 11–14 VDC, 2.2 A @ 12 V (26.4 W) |
| Data Logging Capacity | 16,368 records |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | UV-106-W |
| Instrument Type | Portable |
| Measurement Range | 0–100 ppm (g/m³, µg/mL, mg/L) |
| Detection Limit | 0.1 ppm |
| Response Time | 20 s |
| Zero Drift | <0.05 ppm/month |
| Resolution | 0.1 ppm |
| Data Update Interval | 10 s |
| Accuracy | ±0.05 ppm or ±1% of reading |
| Sampling Flow Rate | 12 mL/min |
| Operating Pressure | 0–50 psi (burst pressure >100 psi) |
| Power | 11–14 VDC, 2.2 A @ 12 V (26.4 W) |
| Data Logger Capacity | 16,368 records |
| Dimensions | 33.8 × 30.5 × 18.5 cm |
| Weight | 6.6 kg |
| Brand | 2B Technologies |
|---|---|
| Origin | USA |
| Model | POM |
| Instrument Type | Portable |
| Measurement Range | 0–10 ppm |
| LOD | 4 ppb |
| Response Time | 10 s |
| Zero Drift | 1.5 ppb |
| Resolution | 1 ppb |
| Detection Principle | UV Absorption at 254 nm |
| FEM Designation | EQOA-0815-227 |
| NIST-Traceable Calibration | Yes |
| Operating Temperature | 0–50 °C |
| Pressure Range | 150–1013 mbar |
| Data Storage Capacity | 8,192 records |
| Power | 7.4 V Li-ion battery (5–8 h) or AC adapter (100–240 VAC to 12 VDC) |
| Dimensions (with GPS) | 12.7 × 7.6 × 3.8 cm |
| Weight (with battery) | 450 g |
| Brand | 4FD |
|---|---|
| Origin | USA |
| Model | BT200 |
| Instrument Type | Online |
| Measurement Range | 0–1 ppmv to 0–20 vol.% |
| Detection Limit | 0.0001 ppmv (at 0–1 ppmv range) |
| Response Time (t95) | <30 s (low-concentration mode) |
| Zero Drift Compensation | Automatic zero-cleaning cycle |
| Resolution | 0.0001 ppmv |
| Analog Output | 4–20 mA or 0–10 V |
| Power Supply | DC 12 V, 1.5 A (AC 100–240 V, 50–60 Hz) |
| Operating Temperature | 0–40 °C |
| Operating Humidity | <90% RH (non-condensing) |
| UV Lamp Lifetime | 20,000 hours (50% output degradation) |
| Calibration Interval | 12 months |
| Accuracy | ±1% of reading or ±10% of full scale, whichever is greater (within validated range |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Product Category | Domestic |
| Model | Aldehyde & Ketone Analysis Cartridge |
| Pricing | Available Upon Request |
| Brand | 4Labplus |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Producer |
| Instrument Category | Domestic |
| Model | SP1200 |
| Instrument Type | 24-Hour Constant-Temperature & Constant-Flow Gas Sampler |
| Configuration | Dual-Channel Gas Sampler |
| Flow Range | 20–1000 mL/min (Channel A: 20–220 mL/min |
| Channel B | 0.2–1.2 L/min) |
| Vacuum Pressure | 50–130 kPa |
| Flow Stability | ≤5% (low-flow mode), ≤2.5% (standard mode) |
| Temperature Measurement Range | –40 to +85 °C (resolution: 0.1 °C |
| accuracy | ±2 °C for inlet temp, ±1 °C for ambient) |
| Pressure Measurement Range | –45 to 0 kPa (inlet), 50–130 kPa (ambient) |
| resolution | 0.01 kPa |
| accuracy | ±0.4 kPa (inlet), ±0.5 kPa (ambient) |
| Data Storage Capacity | Up to 999 sampling records |
| Battery Life | ≥12 h continuous operation |
| Display | 5-inch capacitive touchscreen |
| Interface | USB-C (for firmware update, data export, and power) |
| Optional Peripheral | Bluetooth thermal printer |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | SV-1A |
| Instrument Type | Handheld |
| Flow Rate | 0.1 ft³/min (2.83 L/min) |
| Particle Size Channels | 0.3 µm, 0.5 µm, 5.0 µm |
| Data Storage Capacity | 10,000 sample records |
| Power Supply | 4× AA Ni-MH rechargeable batteries (included) |
| Weight | 0.68 kg (1.5 lb) |
| Communication Interface | RS-232 / RS-485 |
| Compliance | ISO 21501-4, ISO 14644-1, JIS B 9921 |
| Warranty | 1 year |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 737-11 |
| Zero Air Purity | <1 ppb (for O₃, CH₄, hydrocarbons, NO/NOₓ, H₂S, SO₂, COS, CO, CO₂, SF₆, fluorocarbons) |
| Flow Rate | 10 L/min (adjustable up to 20 L/min) |
| Output Pressure | 80 psi |
| Dew Point | -50°C |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 737-12 |
| Zero Air Purity | <1 ppb (for O₃, CH₄, hydrocarbons, NO/NOₓ, H₂S, SO₂, COS, CO, CO₂, SF₆, fluorocarbons) |
| Flow Rate | 12 L/min |
| Output Pressure | 80 PSI |
| Dew Point | -50°C |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 737-13 |
| Zero Air Purity | <1 ppb (for O₃, CH₄, hydrocarbons, NO/NOₓ, H₂S, SO₂, COS, CO, CO₂, SF₆, fluorocarbons) |
| Flow Rate | 0–50 L/min |
| Output Pressure | 80 psi |
| Dew Point | −50 °C |
| Flow Measurement Accuracy | ±1 L/min |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 737-14 |
| Zero Air Purity | <1 ppb (for O₃, CH₄, hydrocarbons, NO/NOₓ, H₂S, SO₂, COS, CO, CO₂, SF₆, fluorocarbons) |
| Flow Rate | 100 L/min |
| Output Pressure | 80 psi |
| Dew Point | −50 °C |
| Flow Measurement Accuracy | ±1 L/min |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 747-10 |
| Zero Air Purity | <1 ppb hydrocarbons and methane |
| Flow Rate | 10 L/min |
| Output Pressure | 90 psig |
| Dew Point | −50 °C |
| Installation | Rack-mountable or benchtop |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | 747-30 |
| Zero Air Purity | <1 ppb hydrocarbons & methane |
| Flow Rate | 30 L/min |
| Output Pressure | 90 psi |
| Dew Point | −50 °C |
| Brand | AADCO |
|---|---|
| Origin | USA |
| Model | ZA-737-250 |
| Zero Air Purity | <1 ppb (for CO, NO, NO₂, SO₂, H₂S, NH₃, O₃, hydrocarbons, COS, SF₆, fluorocarbons) |
| Flow Rate | 250 L/min |
| Output Pressure | 80 psi |
| Dew Point | −50 °C |
| Flow Accuracy | ±1 L/min |
| Electrical Supply | 115 V, 60 Hz (15 A) or 220–240 V, 50/60 Hz |
| Dimensions (H×W×D) | 533 mm × 464 mm × 711 mm |
| Weight | 396 kg |
| Warranty | 1 year |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | AAM Adsorbent Material Filter |
| Price | Upon Request |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA131-GGA |
| Detection Gases | CH₄ (0–100 ppm, optional 0–5%), CO₂ (0–20,000 ppm), H₂O (0–30,000 ppm) |
| Response Time | 3 s (1/e) |
| Warm-up to Data Logging | ≤20 s |
| Dimensions | 12 cm H × 34 cm W × 29.5 cm D |
| Weight (incl. battery) | <5.5 kg |
| Power Consumption | <35 W |
| Precision (1σ, 1s/10s/100s) | CH₄: 1 ppb / 0.4 ppb / 0.2 ppb |
| CO₂ | 0.4 ppm / 0.2 ppm / 0.1 ppm |
| H₂O | 200 ppm / 60 ppm / 30 ppm |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −40–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Data Output | SD card storage, Wi-Fi, USB, Ethernet, analog outputs |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA132 |
| Price | Upon Request |
| Accuracy | < 1% uncertainty (uncalibrated, 5–45 °C) |
| Measured Gases & Ranges | CH₄ (0.01–100 ppm), CO₂ (200–20,000 ppm), NH₃ (1–10,000 ppb), H₂O (500–30,000 ppm) |
| Detection Principle | Fourth-Generation Cavity-Enhanced Absorption Spectroscopy (CEAS) |
| Power Consumption | < 70 W |
| Warm-up Time | < 2 min |
| Data Output Rate | 0.01–1 Hz (user-selectable) |
| Operating Temperature | 5–45 °C |
| Sample Temperature Range | −10–50 °C |
| Relative Humidity | 0–98% RH (non-condensing) |
| Dimensions | 47 × 35.6 × 17.8 cm (18.5″ × 14″ × 7″) |
| Weight | 17 kg |
| Compliance | CE, RoHS, FCC Class A |
| Data Storage | Internal Linux-based SSD with indefinite logging |
| Remote Access | Web-based GUI via Ethernet (HTTPS), full instrument control and diagnostics |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA133 |
| Detection Gases & Ranges | CH₄ (0–100 ppm standard |
| Response Time | 2.5 Hz (1/e) |
| Power Consumption | <35 W |
| Weight | <3 kg |
| Measurement Rate | Up to 10 Hz |
| Technology | Off-Axis Integrated Cavity Output Spectroscopy (OA-ICOS) |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GLA151-N2OCM |
| Price | Upon Request |
| Measured Gases & Ranges | Simultaneous N₂O and CO detection |
| Detection Limits (1σ, 10 sec) | N₂O ≤ 0.2 ppb, CO ≤ 0.2 ppb, H₂O ≤ 40 ppm |
| Linear Range | N₂O up to 4 ppm, CO up to 4 ppm, H₂O up to 30,000 ppm |
| Operating Temperature | 5–45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Measurement Rate | 0.01–10 Hz (user-selectable) |
| Flow Response Time | <30 s (1/e), <10 s (1/e) with ACC-DP3H external diaphragm pump |
| Water Vapor Correction | Real-time spectroscopic correction for dilution and pressure broadening effects |
| Brand | ABB |
|---|---|
| Origin | Canada |
| Model | GLA231 |
| Detection Gases | H₂O, NH₃, HCl, HF |
| Detection Range | Sub-ppb to % level (gas-dependent) |
| Output Options | 0–5 V DC, 4–20 mA, Modbus TCP (optional) |
| Operating System | Embedded Linux |
| Data Storage | Internal HDD with full spectral logging |
| Remote Access | Web-based GUI via Ethernet/IP |
| Calibration | Factory-certified, field-zero capable |
| Display | Integrated touchscreen interface |
| Security | Password-protected configuration and data access |
| Compliance | Designed for industrial process safety and AMC monitoring per SEMI F21, ISO 14644-8, and EPA Method TO-15 context |