| Brand | AP Buck |
|---|---|
| Model | LP-20 |
| Flow Range | 5–20 L/min (constant-flow mode) |
| Accuracy | ±5% of setpoint (at <5 L/min, with APB-109030 controller) |
| Max Backpressure | 60" H₂O (15 kPa) |
| Power | Rechargeable NiCd battery pack (4.8 V, 1.0 Ah) |
| Operating Temperature | 0–40 °C |
| Dimensions | 11.4 × 10.2 × 5.0 cm (H × W × D) |
| Weight | 879 g |
| Inlet Port | 3/8" OD / 1/4" ID |
| Display | EZ-Backlit™ LCD with multilingual UI (English, Spanish, French) |
| Data Logging | Built-in sampling time, flow rate, and total volume tracking |
| Compliance | Designed for OSHA, NIOSH, and ISO 17025-aligned field sampling workflows |
| Brand | AP2E |
|---|---|
| Origin | Imported (France) |
| Model | ProCeas |
| Principle | Tunable Diode Laser Infrared Absorption Spectroscopy (TDLAS) with Optical Feedback Cavity-Enhanced Absorption Spectroscopy (OFCEAS) |
| Configuration | Online, Rack-Mountable (19", 4U) |
| Response Time | <1 s |
| Detection Limits | Sub-ppb to low-ppm (gas-dependent) |
| Measured Gases | HCHO, H₂S, CH₄, CO, CO₂, H₂, H₂O, HCl, HCN, HF, N₂O, NH₃, O₂, NO, NO₂ |
| Sampling | Low-Pressure Sampling (LPS) System with Sonic Nozzle |
| Zero Drift | None (real-time cavity ring-down noise monitoring & auto-zero compensation) |
| Calibration | Factory pre-calibrated |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas COS |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 2 ppb |
| Precision (1σ) | 0.6 ppb + 0.5% of reading |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <60 s |
| Measurement Range | 0–10 ppm |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Control | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA / 0–10 V), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂ |
| Detection Principle | Optical-feedback Cavity Enhanced Absorption Spectroscopy (OF-CEAS) |
| Operating Pressure | <100 mbar (absolute) |
| Detection Limits (3σ) | H₂O ≤ 0.01 ppm, CH₄ ≤ 0.001 ppm, O₂ ≤ 5 ppm, CO₂ ≤ 0.2 ppm, CO ≤ 0.001 ppm, H₂S ≤ 0.001 ppm, HCHO ≤ 0.001 ppm, HCOOH ≤ 0.005 ppm, NH₃ ≤ 0.001 ppm, HCl ≤ 0.001 ppm |
| Compliance | T/CECA-G0015-2017 (equivalent to ISO 14687-2:2019) |
| Calibration | Factory-pre-calibrated, integrated auto-zero and span verification |
| Carrier Gas | None required |
| Sample Volume Requirement | Minimal (<10 mL/min at sub-atmospheric pressure) |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas H₂S |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | 1 ppb |
| Accuracy (1σ) | 0.3 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | <5 s |
| Measurement Range | 0–5000 ppb |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temperature Range | −10 to +45 °C |
| Sample Humidity Limit | <99% RH, non-condensing |
| Sample Flow Rate | >400 mL/min |
| Output Interfaces | Ethernet, Modbus TCP/IP & RTU, 4–20 mA analog, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Form Factor | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCHO |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 60 s) | <1 ppb |
| Accuracy (1σ) | 0.15 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–10 ppm |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH, non-condensing |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HCl |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| HCl Detection Limit (3σ, 300 s) | 1 ppb |
| HCl Accuracy (1σ, 300 s) | 0.3 ppb + 0.1% of reading |
| HCl Measurement Range | 0–1000 ppb |
| H₂O Measurement Range | 0–5% |
| H₂O Detection Limit (3σ, 300 s) | 180 ppm |
| Zero Drift (72 h) | ±0.20 ppb |
| Response Time (10–90%) | <300 s |
| Measurement Interval | 2 s |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Cavity Pressure Stability | ±0.016 mbar |
| Sample Temp. Range | −10 to +45 °C |
| Max. Sample Humidity | <99% RH (non-condensing) |
| Sample Flow Rate | >400 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog Outputs, USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas HF |
| Detection Principle | Optical-Feedback Cavity-Enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.015 ppb |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 s |
| Response Time (10–90%) | < 300 s |
| Measurement Range | 0–1000 ppb HF |
| Optional Co-measurements | O₂ (0–21%), H₂O (0–5%) |
| Cavity Temperature Stability | ±0.002 K (1 s), ±5×10⁻⁵ K (30 min) |
| Pressure Control | ±0.016 mbar |
| Sample Temp. | −10 to +45 °C |
| Sample Humidity | < 99% RH, non-condensing |
| Flow Rate | < 2000 mL/min |
| Data Interfaces | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power | 110–230 VAC, 50–60 Hz, 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Brand | AP2E |
|---|---|
| Origin | France |
| Model | ProCeas NH₃ |
| Detection Principle | Optical-feedback Cavity-enhanced Absorption Spectroscopy (OF-CEAS) |
| Detection Limit (3σ, 300 s) | < 0.05 ppb |
| Accuracy (1σ) | 0.015 ppb + 0.1% of reading @ 300 s |
| Zero Drift (72 h) | ±0.20 ppb |
| Measurement Interval | 1 Hz |
| Measurement Range | 0–1000 ppb (guaranteed), 0–10 ppm (operational) |
| Cavity Volume | 25 mL |
| Temperature Control Stability | ±0.002 K @ 1 s |
| Pressure Control Stability | ±0.016 mbar |
| Sample Flow Rate | >400 mL/min |
| Operating Ambient Temperature | −10 to +45 °C |
| Relative Humidity | <99% RH (non-condensing) |
| Data Outputs | Ethernet, Modbus TCP/IP & RTU, Analog (4–20 mA), USB |
| Power Supply | 110–230 VAC, 50–60 Hz |
| Power Consumption | 150 VA |
| Dimensions | 19″ rack-mount, 4U |
| Weight | 20 kg |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | APC Peltier & Compressor-Based Gas Cooler |
| Pricing | Upon Request |
| Brand | API |
|---|---|
| Model | N901 |
| Detection Principle | Gas Chromatography–Flame Ionization Detection (GC-FID) |
| Measured Parameters | Total Hydrocarbons (THC), Methane (CH₄), Non-Methane Hydrocarbons (NMHC) |
| NMHC Calculation Method | NMHC = THC − CH₄ |
| Detector Type | Flame Ionization Detector (FID) |
| Sample Inlet Filtration | Stainless Steel Sintered Filter |
| Control & Data Processing | Integrated NumaView™ Software (NVS), Standalone Operation |
| Compliance Context | Designed for EPA Method 25A, ASTM D6348, ISO 8573-5, and EU Directive 2008/50/EC ambient air monitoring requirements |
| Power Consumption | Low-power embedded architecture |
| Design Philosophy | Modular hardware, field-serviceable electronics, maintenance-minimized gas path |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T100 |
| Detection Principle | Ultraviolet Fluorescence |
| Measurement Range | 0–50 ppb or 0–20 ppm (selectable dual range) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5%/24 h, <1%/7 d |
| Response Time (T95) | <100 s |
| Sample Flow Rate | 700 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Compensation | Yes |
| Pressure Compensation | Yes |
| Operating Temperature | 5–40 °C |
| Power Supply | 100–240 VAC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 16 kg |
| Certifications | U.S. EPA EQPM Designated, Eignungsgeprüft, CE |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T200 |
| Type | Online Gas Analyzer |
| Measurement Principle | Chemiluminescence |
| Detection Targets | NO, NO₂, NOₓ (simultaneously independent) |
| Range Options | 0–50 ppb or 0–20 ppm (dual-range selectable) |
| Zero Noise | 0.2 ppb (RMS) |
| LOD | 0.4 ppb |
| Zero Drift | <0.5 ppb/24 h, <1 ppb/7 d |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 d |
| Response Time (T95) | <60 s |
| Lag Time | 20 s |
| Sample Flow Rate | 500 cm³/min ±10% |
| Linearity | ±1% of full scale |
| Accuracy | ±0.5% of reading |
| Temperature Range | 5–40 °C |
| Temp. Coefficient | <0.1%/°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Voltage Coefficient | <0.1%/V |
| Dimensions (H×W×D) | 178 mm × 432 mm × 597 mm |
| Weight (Analyzer) | 18 kg |
| External Pump Weight | 7 kg |
| Power | 100–240 VAC, 50/60 Hz, 250 W |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, isolated 4–20 mA, dual bidirectional RS-232 |
| Certifications | U.S. EPA EQPM Designated, CE, Eignungsgeprüft (German PTB Verification) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T300 |
| Instrument Type | Online Gas Analyzer |
| Detection Principle | Gas Filter Correlation Infrared Absorption (GFC-IR) |
| Measurement Range | 0–1 ppm or 0–1000 ppm (selectable dual range) |
| Repeatability | ±1% of Full Scale (F.S.) |
| Resolution | 0.1 ppm |
| Response Time (T95) | <60 s |
| Zero Drift | <0.1 ppm/24 h, <0.2 ppm/7 days |
| Span Drift | <0.5% of reading/24 h, <1% of reading/7 days |
| Linearity Error | ±1% of full scale |
| Zero Noise (RMS) | <0.02 ppm |
| Span Noise | <0.5% of reading |
| LOD (Limit of Detection) | <0.04 ppm |
| Optical Path Length | 14 m |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Pressure & Temperature Compensation | Yes |
| Output Signals | 10 V, 5 V, 1 V, 100 mV, 4–20 mA (isolated), dual RS-232 (bidirectional) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Certifications | U.S. EPA Designated Method, Eignungsgeprüft (German Performance Verification), CE |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T400 |
| Instrument Type | Fixed-mount |
| Measurement Range | 0–10 ppb (standard), optional dual-range 0–100 ppb / 0–10 ppm |
| LOD | <0.6 ppb |
| Response Time (T95) | <20 s |
| Zero Drift | <1.0 ppb/24 h |
| Span Drift | <1% of reading/7 days |
| Resolution | 0.1 ppb (0–50 ppb range) |
| Sample Flow Rate | 800 cm³/min ±10% |
| Operating Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Power Supply | 100–240 V AC, 50/60 Hz, 250 W |
| Dimensions (H×W×D) | 178 × 432 × 597 mm |
| Weight | 18 kg |
| Output Signals | 0–10 V, 0–5 V, 0–1 V, 0–100 mV, 0–20 mA, or 4–20 mA (isolated) |
| Brand | API |
|---|---|
| Origin | USA |
| Model | T751 |
| Output Flow Rate | 5 SLPM @ 30 psig |
| Maximum Output Pressure | 30 psig |
| Dew Point | < –20 °C (until desiccant saturation) |
| SO₂, NO, NO₂, O₃, H₂S Removal | < 0.5 ppb |
| CO Removal (with optional CO scrubber) | < 0.025 ppm |
| Compressor Type | Single-cylinder, oil-free piston pump |
| Power Input | 110–240 VAC, 50–60 Hz, 130 W |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 178 × 470 × 356 mm |
| Weight | 10.9 kg |
| Desiccant | Silica gel with dew point LED indicator |
| Warm-up Time | 30 minutes |
| Brand | API |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | T751H |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Flow Rate | 10 SLPM @ 30 psig |
| Max Output Pressure | 30 psig |
| Dew Point | < −20 °C (until desiccant saturation) |
| Desiccant Type | Regenerable, heatless silica gel |
| Desiccant Lifetime | >5 years |
| SO₂ Output Concentration | < 0.025 ppb |
| NO Output Concentration | < 0.025 ppb |
| NO₂ Output Concentration | < 0.025 ppb |
| O₃ Output Concentration | < 0.3 ppb |
| CO Output Concentration | < 10 ppb |
| Hydrocarbon (HC) Output Concentration | < 0.25 ppb |
| Compressor | Single-cylinder, oil-free piston pump |
| Power Input | 110–240 VAC, 50–60 Hz, 425 W |
| Operating Temperature | 5–40 °C |
| Dimensions (L×W×H) | 229 × 559 × 351 mm |
| Weight | 21.3 kg |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX-PPAM |
| Type | Portable Multicomponent Gas Analyzer Module |
| Principle | Silicon-Microfabricated Gas Chromatography with Integrated NEMS/μTCD Detection |
| Response Time | ≤10 ms (injection) |
| Repeatability | <0.1% RSD for sample injection |
| Sample Compatibility | Natural gas, ambient air, permanent gases, hydrocarbons (C1–C10), VOCs, sulfur compounds, halogenated organics, oxygenates |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Carrier Flow Rate | ~1 mL/min |
| Injection Volume | <15 µL |
| Column Temperature Range | 50–160 °C (stability <0.1 °C) |
| Detector Operating Range | Ambient to 120 °C |
| Detection Range | sub-ppb (with preconcentration) to % v/v |
| Module Dimensions | 27 × 10 × 3 cm |
| Weight | 900 g |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | ChromPix 2 |
| Type | Portable GC-based Analyzer |
| Principle | Microfabricated Gas Chromatography with Silicon-based μ-TCD and NEMS Detection |
| Response Time | <0.01 s (detector response) |
| Sample Types | Natural gas, biogas, industrial stack emissions, VOCs (including BTEX), permanent gases (N₂, O₂, CO₂), sulfur compounds (H₂S, THT, mercaptans), and specialty gases |
| Column Capacity | Up to 4 parallel capillary columns |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Operating Temperature | −10–40 °C |
| Power | 100–240 V AC, 50–60 Hz, 150 W (config-dependent) |
| Dimensions | 450 × 460 × 220 mm |
| Weight | 10 kg |
| Column Temp Range | 50–160 °C (stability <0.1 °C) |
| Detection Range | sub-ppm to % v/v |
| LOD (VOCs w/ preconcentration) | <1 ppb |
| LOD (H₂S) | 7 ± 0.7 ppm (with sample conditioning) |
| LOD (THT) | 2 ± 0.2 ppm (with sample conditioning) |
| LOD (C₁–C₆ hydrocarbons) | <5 ppm |
| LOD (C₆–C₁₂) | <1 ppm |
| LOD (N₂/O₂/CO₂) | <10 ppm |
| LOD (BTEX) | <1 ppm |
| Analysis Time | ≤1 min (separation), ≤2 min (incl. backflush) |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Model | APIX MAX-One™ |
| Type | Portable |
| Response Time | 0.01 s |
| Detection Principle | MEMS-based Micro-Gas Chromatography with μTCD |
| Compliance | ATEX II 2G Ex IIB+H2 T6, CSA Div 1 Class I, Group B, C, D, AEx d IIB+H2 T6, NeSSI-compatible |
| Dimensions | 360 × 350 × 170 mm |
| Weight | 25 kg |
| Power Input | 100–240 V AC, 50–60 Hz |
| Max Power Consumption | 750 W |
| Operating Temperature | −10 to +40 °C |
| GC Column Temp Range | 50–160 °C (stability < 0.1 °C) |
| Carrier Gases | He, H₂, N₂, Ar, synthetic dry air |
| Sample Injection Pressure | 1–15 bar |
| Injection Volume | < 15 µL |
| Detector | Micro-Thermal Conductivity Detector (μTCD), ambient-120 °C |
| Detection Range | sub-ppm to % v/v |
| LOD (typical) | Permanent gases (N₂, CO₂, O₂) < 10 ppm |
| Brand | APIX Analytics |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC Series |
| Pricing | Available Upon Request |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | APL-GDS-100 |
| Price Range | USD 1,400 – 2,800 |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MO-200 |
| Measurement Principle | Electrochemical (Galvanic Cell) |
| Range | 5–100 % O₂ |
| Repeatability | ±0.1 % at 20.9 % O₂ |
| Nonlinearity | <1 % |
| Response Time (t₉₀) | 14 s |
| Operating Temperature | 0–50 °C |
| Relative Humidity Limit | <90 % RH |
| Pressure Range | 60–150 kPa |
| Gas Interference | Immune to CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ |
| Probe Body Dimensions | Ø32 mm × 68 mm |
| Diffusion Cap (A0-001) | Ø35 mm × 35 mm |
| Flow-Through Cap (A0-002) | Ø32 mm × 91 mm |
| Cable Length | 2 m |
| Data Logger Capacity | 99 manual entries |
| Display Unit Dimensions | 126 mm × 70 mm × 24 mm |
| Integrated Temperature Sensor | Yes |
| Heated Membrane | Yes |
| Enclosure Material | Acid-resistant polymer |
| Compliance | CE-marked per EN 61326-1 (EMC), EN 61010-1 (Safety) |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SO-100 |
| Output | 0–50 mV (SO-100), 0–12 mV (SO-200) |
| Measurement Range | 0–100% O₂ |
| Accuracy | <0.02% drift/day |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Response Time | 60 s (SO-100), 12 s (SO-200) |
| Operating Temperature | –20 to +60 °C |
| Relative Humidity | 0–100% RH |
| Pressure Range | 60–140 kPa |
| Power Supply | 12 V for heater |
| Sensor Housing | Polypropylene valve body |
| Cable Length | 2 m |
| Weight | 210 g |
| Lifetime | >10 years (SO-100), >5 years (SO-200) |
| Interference | None from CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SO-210 Ambient Oxygen Sensor |
| Measurement Range | 0–100% O₂ |
| Accuracy (Stability) | ±0.05% O₂ (under stable ventilation) |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Operating Temperature | −20 to +60 °C |
| Relative Humidity Range | 0–100% RH |
| Pressure Range | 60–140 kPa |
| Response Time (t₉₀) | 12 s |
| Output Signal | 12 mV at 20.95% O₂ |
| O₂ Consumption Rate | 2.2 µmol/day at 20.95% O₂, 23 °C |
| Cross-Sensitivity | Negligible to CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ |
| Power Supply | 12 V for heater, 2.5 V for thermistor excitation |
| Cable | 5 m foil-shielded twisted pair |
| Optional Diffusion Cap | 3.5 cm L × 3.5 cm Ø, 125 vent holes |
| Optional Flow-Through Cap | 3.2 cm L × 3.2 cm Ø, 1/8″ conical hose adapter |
| Integrated Temperature Sensor | NTC thermistor |
| Weight | 175 g |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SO-220 |
| Measurement Range | 0–100% O₂ |
| Accuracy (Stability) | ±0.05% O₂ (under stable ventilation) |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Operating Temperature | −20 to +60 °C |
| Relative Humidity Range | 0–100% RH |
| Pressure Range | 60–140 kPa |
| Response Time (t₉₀) | 12 s |
| Output Signal | 12 mV at 20.95% O₂ |
| O₂ Consumption Rate | 2.2 µmol/day at 20.95% O₂, 23 °C |
| Interferent Resistance | CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ — no interference |
| Power Supply | 12 V for heater, 2.5 V for thermistor activation |
| Cable | 5 m foil-shielded |
| Diffusion Cap (optional) | 3.5 cm L × 3.5 cm Ø, 125 vent holes |
| Flow-through Cap (optional) | 3.2 cm L × 3.2 cm Ø, 1/8″ conical adapter for tubing |
| Integrated Temperature Sensor | Thermocouple |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | APS |
| Pricing | Upon Request |
| Brand | Aquaria |
|---|---|
| Origin | Italy |
| Model | CF20 α |
| Compliance | UNI EN 12919 |
| Cabinet Material | Front & Sides – High-Density Polyurethane |
| Viewing Panel | Lockable Transparent Acrylic |
| Vacuum Gauge | Integrated for System Leak Detection & Diaphragm Integrity Verification |
| Volumetric Measurement | Barometric Pressure-Compensated Flow Integration (±0.2 L accuracy) |
| Temperature Monitoring | Real-Time Digital Thermometer |
| Drain Port | Rear-Mounted Condensate Drain |
| Brand | Aquaria |
|---|---|
| Origin | Italy |
| Model | MICROFLOW α |
| Sampling Principle | Impaction-Based |
| Flow Rates | 28.3–120 L/min (up to 180 L/min peak) |
| Culture Dish Compatibility | Ø60 ± 2 mm and Ø90 ± 2 mm Petri Dishes |
| Display | LCD with Multilingual Interface (English, Italian, French, German, Spanish) |
| Housing Material | Medical-Grade Polyurethane |
| Sampling Head | Anodized Aluminum, Autoclavable |
| On-Site Sterilization | Integrated UV Sterilization Pen |
| Operating Modes | Programmable, Continuous Programmed, Delayed Start, Remote-Controlled Sampling |
| Weight | <2.5 kg |
| Dimensions | 220 × 140 × 180 mm (W × D × H) |
| Brand | ARA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | FTS |
| Pricing | Available Upon Request |
| Enclosure Dimensions | 10.62" × 9.68" × 4.87" (27 cm × 24.6 cm × 12.4 cm) |
| Enclosure Weight | 5 lbs (2.27 kg) |
| Flow Ranges | 1–3 LPM, 2–9 LPM, and 9–25 LPM |
| Flow Accuracy | ±1% of reading |
| Temperature Range | −30°C to +50°C |
| Temperature Accuracy | ±0.5°C |
| Barometric Pressure Range | 250–800 mmHg |
| Pressure Accuracy | ±5 mmHg |
| Battery Type | Rechargeable NiMH |
| Battery Life | Up to 60 hours |
| Calibration Traceability | NIST-traceable |
| Flow Measurement Principle | Venturi-based differential pressure |
| Environmental Rating | IP65-rated weather-resistant enclosure |
| Connectivity | Integrated Bluetooth 5.0 for iOS/Android mobile devices |
| Standard Conditions Configuration | User-definable STP (Standard Temperature and Pressure) settings |