Gas Samplers
Filter
Showing 121–128 of 128 results
| Brand | URG |
|---|---|
| Origin | USA |
| Model | URG-2000-30x242-3CSS |
| Number of Channels | 3 |
| Annular Spacing | 1 mm |
| Length | 242 mm |
| End Fittings | Dual #30 Threaded Ports |
| Flow Straightener | PTFE-Coated on One End |
| Housing Material | Stainless Steel |
| Etched Glass Surface | Yes |
| Protective End Caps | Included |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XC-30B |
| Instrument Type | 24-Hour Temperature- and Flow-Controlled Gas Sampler |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0.1–2500 mL/min |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ±5% over 24 h |
| Flowmeter Accuracy | ±2.5% FS (dry gas meter), ±2% FS (mass flow sensor) |
| Rated Service Life at Max Flow & Backpressure | 5000 hours |
| Continuous Operation Time at Max Flow & Backpressure | 8 h |
| Brand | Xonteck |
|---|---|
| Origin | USA |
| Model | 960 |
| Instrument Type | Automated Whole-Air Canister Purge and Bakeout System |
| Configuration Options | Benchtop Split-Unit or Integrated Oven-Type |
| Maximum Simultaneous Canisters | 4 × 6-L or 2 × 15-L (Oven-Type) |
| Vacuum Base Pressure | < 50 mTorr (≤ 6.7 Pa) |
| Heating Temperature Range | Ambient to 100 °C |
| Vacuum Pump | Integrated High-Capacity Scroll Vacuum Pump |
| Ultimate Pumping Speed | ≥ 100 L/min (at atmospheric inlet) |
| Pressure Sensing | Dual-Range Absolute Pressure Transducers (0–300 kPa, resolution 0.1 kPa |
| Flow Control | Programmable Mass Flow Controllers for Inert Gas Purge (N₂ or Zero Air) |
| Humidification Capability | Integrated Saturated Moisture Delivery Module (optional, for hydrophobic surface conditioning) |
| Flow Stability | ±5% over full operational cycle |
| Flowmeter Accuracy | ±2.5% FS |
| Pump Service Life at Max Load | ≥ 5,000 hours |
| Continuous Bakeout Runtime at Max Flow & Backpressure | 8 hours |
| Construction Materials | 316L Stainless Steel Tubing & Fittings, PTFE-Sealed Valves, Electropolished Internal Surfaces |
| Control System | Microprocessor-Based Embedded Controller with Real-Time Cycle Monitoring, Audible End-of-Cycle Alert, and Non-Volatile Parameter Storage |
| Acoustic Noise Level | < 65 dB(A) |
| Dimensions (Oven-Type) | 860 mm (H) × 945 mm (W) × 680 mm (D) |
| Dimensions (Split-Unit Host) | 665 mm (H) × 640 mm (W) × 270 mm (D) |
| Stand | 830 mm (H) × 770 mm (W) × 750 mm (D) |
| Weight (Oven-Type) | 75 kg |
| Weight (Split-Unit) | 50 kg |
| Brand | Xonteck |
|---|---|
| Origin | USA |
| Instrument Type | 24-Hour Isothermal & Isokinetic Gas Sampler |
| Configuration | Multi-Channel Gas Sampler |
| Flow Range | 3–50 psig |
| Maximum Vacuum Pressure | 30,000 Pa |
| Flow Stability | ±5% |
| Mass Flow Controller Accuracy | ±2.5% FS |
| Service Life at Max Flow & Backpressure | 5,000 hours |
| Continuous Operation Duration at Max Flow & Backpressure | 8 hours |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 924 |
| Pricing | Upon Request |
| Brand | Zhongyi Yusheng |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic (China) |
| Model | SMCS-1 |
| Instrument Type | Conventional Automated Gas Sampler |
| Flow Control | Integrated Mass Flow Controller (MFC) with Pressure Sensor (kPa-level) |
| Leak Detection | Automated Pre-sampling Canister Leak Check |
| Power Supply | Rechargeable Lithium Battery (24 h continuous operation) |
| Data Output | Digital pressure display, flow logging, canister pressure monitoring, USB data export |
| Accessories | Portable protective case, optional particulate inlet filter, optional sampling tripod |
| Compliance | Designed for EPA Method TO-14/TO-15, ASTM D5466, ISO 16017-1 workflows |
| Brand | ZHYUSM |
|---|---|
| Model | SMCC-1 |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Power | 400 W |
| Pump Type | Oil-Free Scroll Vacuum Pump |
| Ultimate Vacuum | <1.6 Pa (12 mTorr) |
| Pumping Speed | 250 L/min |
| Max Simultaneous Heating Capacity | 8 × 6 L Summa® Canisters |
| Cleaning Cycles | Programmable (1–99), Manual Mode Available |
| Humidification | Integrated High-Purity N₂ Humidifier |
| Surface Treatment | Silanized Gas Path Components |
| Control Interface | Capacitive Touchscreen with Method Storage |
| Leak Check | Automated Pre-Valve-Opening Vacuum Integrity Test |
| Thermal Uniformity | Forced-Air Circulation via Vortex Fan in Heated Chamber |
| Real-Time Monitoring | Pressure, Temperature, Elapsed Time, Valve Status |
| Cooling | Active Heat Dissipation System |
| Mobility | Heavy-Duty Swivel Casters |
