Gas Samplers
Filter
Showing 91–120 of 134 results
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | AirLite® |
| Flow Range | 5–3000 mL/min (5–500 mL/min with optional Low-Flow Kit) |
| Backpressure Compensation | Up to 30 in. H₂O |
| Battery Life | ≥8 hours at full flow range using alkaline AA batteries |
| Flow Accuracy | ±5% after calibration |
| Weight | 340 g |
| Dimensions | 10.1 × 7.9 × 4.8 cm |
| Power Supply | Two 1.5 V AA alkaline batteries |
| Display | LED indicators for sampling status, flow condition, and low-battery warning |
| Auto-Shutdown | Activates when flow error exceeds ±5% |
| Built-in | Flow pulse dampener, particulate filter |
| External Mounting | Dedicated orifice for impactor bottle bracket |
| EMI/RFI Shielding | Conductive polymer housing compliant with IEC 61000-4 series immunity standards |
| Certifications | Meets OSHA, NIOSH, and ISO 13137 requirements for personal air sampling pumps |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported |
| Model | Anasorb CSC Activated Carbon Sorbent Tube |
| Pricing | Available Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Anasorb Sorbent Tubes |
| Type | Pre-packed, Certified Air Sampling Sorbent Tubes for Occupational & Environmental Monitoring |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Chromosorb |
| Pricing | Available Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | TD Tube |
| Adsorbent | Carbopack X |
| Tube Material | SilcoNert 2000-coated stainless steel |
| Dimensions | 3.5 in × 0.25 in OD |
| Diffusion Rate (Benzene) | 0.67 mL/min |
| Compliance | EPA Method 325A, HSE MDHS 104 |
| Analytical Method | GC-FID or GC-MS per EPA Method 325B |
| Storage Requirement | Use within 30 days after conditioning |
| Fitting | Brass Swagelok nut with PTFE ferrule |
| Includes | Diffusion cap (P/N 10526-100), shelter (P/N 526-100), barcode & orientation arrow marking |
| Sample Duration | 14-day integrated sampling |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | DNPH-Silica |
| Dimensions (ID × Length) | 6 mm × 100 mm or 8 mm × 115 mm |
| Sorbent Mass | 300/150 mg (6×100 mm) or 1500/300/150 mg (8×115 mm) |
| Sorbent | High-Purity Silica Coated with DNPH |
| Compliance | HJ 683–2014, HJ/T 400–2007, GB/T 39897–2021, GB/T 27630–2011, NIOSH 2016, EPA TO-11A, MDHS 102, ASTM D5197/D6196 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Flite 3 |
| Flow Range | 2,000–20,000 mL/min |
| Power Options | Rechargeable Lead-Acid Battery (3.2 Ah or 7 Ah) or AC Adapter |
| Operating Temperature | −5 to 50 °C |
| Housing | Rugged Steel Enclosure with Integrated Handle |
| Dimensions | 11.5 × 20.6 × 17.8 cm |
| Weight | 2.24 kg (bare), 3.56 kg (with 3.2 Ah battery), 4.48 kg (with 7 Ah battery) |
| Compliance | Designed for ASTM D6330, ISO 16000-2, NIOSH Method 7400/7402, and OSHA ID-160 applications |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Grab Air |
| Flow Rate | 1.0 L/min |
| Power Source | Single 9V Alkaline Battery |
| Battery Life | ~1000 L at 1.0 L/min |
| Dimensions | 10.8 × 6.3 × 2.7 cm (4.25 × 2.5 × 1.1 in) |
| Weight | 186 g (6.6 oz) |
| Pump Type | Diaphragm |
| Intrinsic Safety | Not certified for hazardous or explosive atmospheres |
| Sample Interface | Direct bag connection via outlet port |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Impingers |
| Pricing | Upon Request |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Leland Legacy |
| Flow Range | 5–15 L/min |
| Constant Flow Accuracy | ±5% of setpoint |
| Battery Runtime | ≥24 h at 5 L/min (typical) |
| Data Logging | Yes (start/end time, volume, temperature, barometric pressure, pump status) |
| Noise Level | 62.5 dB (bare pump), 52 dB (with optional noise-reduction enclosure, 224-89) |
| Operating Temperature | 0–45 °C |
| Dimensions | 20.0 × 10.0 × 7.0 cm |
| Weight | 1000 g |
| Enclosure | ESD-safe thermoplastic with rubber overmold and integrated belt clip |
| Power | Rechargeable Li-ion battery |
| Timer Range | 1–99999 min (up to 69 days) |
| Flow Compensation | Automatic restart on blockage |
| Built-in particle trap | Yes |
| Compliance | CE-marked per EU directives |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | OVS |
| Tube Dimensions | 138 mm × 7.5 mm OD |
| Flow Rate | 1 L/min (typical) |
| Analytical Compatibility | GC or HPLC |
| Adsorbent Configurations | Dual-bed (e.g., XAD-2 270/140 mg, Tenax, Silica Gel, XAD-7) |
| Filter Type | Glass fiber (G), PTFE (T), Quartz (Q), Foam (F) |
| Storage Requirement | Refrigerated or frozen |
| Compliance | Designed for OSHA, NIOSH, and EPA sampling methods |
| Packaging | Individually sealed in inert, low-background packaging |
| Shelf Life | Limited — refer to lot-specific expiration date |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Pocket Pump TOUCH (220-1000TC) |
| Flow Range | 20–500 mL/min (constant-flow mode) |
| Backpressure Compensation | Up to 20 in. H₂O |
| Flow Stability | ±5% of setpoint or ±3 mL/min, whichever is greater |
| Flowmeter Accuracy | ±0.5% of reading |
| Operating Time | ≥20 hours at maximum flow and backpressure |
| Power Source | Rechargeable Li-ion battery (3.6 V, 2.6 Ah) |
| Dimensions | 8.1 × 9.7 × 3.8 cm |
| Weight | 235 g |
| Ingress Protection | IP64 |
| Certifications | CE, UL Intrinsically Safe |
| Brand | SKC |
|---|---|
| Origin | USA |
| Product Line | Porapak Series |
| Tube Dimensions (OD × Length) | 6 mm × 40–110 mm |
| Sorbent Mass | 35–175 mg per section |
| Dual-Bed Configuration | Yes (e.g., 88/44 mg, 100/50 mg, 150/75 mg) |
| End Caps | Glass Wool or Polyethylene Frit |
| Separator | Stainless Steel or Glass |
| Packaging | Individually sealed in foil pouches, 10 tubes per pack |
| Part Numbers | 50226-59-01, 50226-114, 50226-115, 50226-59-03, 50226-59-04, 50226-116A |
| Compliance | Compatible with EPA Methods TO-1, TO-2, TO-14A, TO-15, and ISO 16017-1 |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | PUF Tube |
| Compliance | EPA TO-10A, EPA IP-8, ASTM D4861, ASTM D4947, ASTM D6209, EPA IP-7, EPA TO-4A, TO-9A, TO-13A, EPA Method 600/8-80-038 |
| Dimensions (Small) | 22 mm OD × 100 mm L |
| Dimensions (Large) | 65 mm OD × 125 mm L |
| Flow Rate Range (Small) | 1–5 L/min |
| Sampling Duration (Small) | Up to 24 h |
| Adsorbent Configuration | Pure PUF, PUF/Glass Fiber, PUF/Tenax/PUF, PUF/XAD-2/PUF |
| Pre-cleaned Adsorbent | Yes |
| Background Performance | Low-blank, solvent-rinsed |
| Packaging | Individually sealed in inert foil pouches |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | SamplePro FlexFilm |
| Material | Proprietary low-adsorption polymer film |
| Max Operating Temperature | 60°C (140°F) |
| VOC Background | Lower than Tedlar® |
| VOC Stability | Equivalent to Tedlar® |
| Compatible Gases | VOCs, CO, CO₂, CH₄, SF₆, VSCs |
| Volume Range | 0.5 L to 100 L |
| Fitting Options | Single polypropylene valve/septum or dual stainless steel valves |
| Sterility | Non-sterile, single-use only |
| Compliance | Designed for EPA Method TO-15, ASTM D5466, ISO 16000-6, and OSHA ID-253 sampling protocols |
| Brand | SKC |
|---|---|
| Origin | USA |
| Type | Imported Gas Sampling Sorbent Tube |
| Model | Silica Gel Sorbent Tube |
| Compliance | NIOSH, OSHA, ASTM, EPA Methods |
| Key Dimensions | 6–10 mm OD × 70–210 mm Length |
| Adsorbent Mass Range | 100–3750 mg per segment |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | SWYPEs |
| Type | Single-use, compound-specific colorimetric surface and skin wipe indicator for workplace chemical contamination detection |
| Compliance | Designed for OSHA, NIOSH, and ACGIH exposure assessment workflows |
| Intended Use | Qualitative on-site detection of surface-resident and dermal chemical residues (e.g., aldehydes, amines, hydrazines, organophosphates, heavy metal ions) |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Tedlar |
| Material | DuPont™ Tedlar® Polyvinyl Fluoride (PVF) Film |
| Thickness | 2 mil (50.8 µm) |
| Temperature Range | -72°C to +107°C |
| VOC Recovery | ≥80% after ≥48 hours |
| Compliance | EPA Method TO-14A, TO-15, and TCLP-compatible |
| Fitting Options | Single polypropylene inlet/outlet or dual stainless steel valves |
| Volume Options | 1 L, 3 L, 5 L |
| Base Contamination | Ultra-low VOC background |
| Brand | SKC |
|---|---|
| Origin | USA |
| Model | Tenax |
| Type | Thermal Desorption Sorbent Tube for Volatile Organic Compounds (VOCs) Sampling |
| Compliance | NIOSH 1501, OSHA ID-259, ASTM D6196, EPA TO-17, IP-1B |
| Adsorbent Options | Tenax TA (poly(2,6-diphenyl-p-phenylene oxide)), Tenax GR (graphitized carbon black–Tenax composite) |
| Tube Dimensions | 6 mm × 70 mm to 16 mm × 125 mm |
| Adsorbent Mass Range | 20 mg to 11.6 g per bed |
| Construction | Stainless steel (SS) or glass (GS) tube body with precision-sieved adsorbent beds and optional backup layer |
| Brand | SKC |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Vac-U-Chamber |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Import Status | Imported |
| Model | Thermo Scientific 5030 SHARP (High-Volume Sampling Configuration) |
| Instrument Type | High-Volume Ambient Air Sampler |
| Sampling Path | Single-Channel |
| Flow Range | PM₁₀ & PM₂.₅: 40 SCFM (1,133 L/min) |
| Flow Accuracy | Mass Flow Control: ±2.5% deviation over 24 h |
| Volumetric Flow Control | <1% deviation over 24 h |
| Power | 750 W (Mass Flow) / 840 W (Volumetric Flow) |
| Motor | 0.6 HP (Mass Flow) / 0.1 HP (Volumetric Flow) |
| Compliance | EPA Reference Method for PM₁₀/PM₂.₅ (40 CFR Part 53), ISO 12103-1, ASTM D1424 |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-1000H |
| Instrument Type | 24-Hour Constant-Temperature Constant-Flow Gas Sampler |
| Configuration | Multi-Channel Gas Sampler |
| Flow Range | 0.8–2.0 L/min |
| Maximum Vacuum Pressure | 30,000 Pa |
| Flow Stability | ≤3% |
| Flowmeter Accuracy | ±2.5% |
| Service Life at Max Flow & Backpressure | 6,000 hours |
| Continuous Operation Time at Max Flow & Backpressure | 10 hours |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-110E |
| Instrument Type | Dual-Channel Constant-Flow Air Sampler |
| Flow Control | Microprocessor-Controlled Constant Flow |
| Power Supply | Rechargeable DC Battery (≥20 h runtime) |
| Compliance | HJ/T 375–2007, JJG 956–2013, GB/T 17061–1997, HJ 644–2013 |
| Display & Interface | Full Chinese LCD with Real-Time Parameter Feedback |
| Environmental Sensors | Integrated Barometric Pressure & Ambient Temperature Measurement |
| Data Logging | Dual-Channel Independent Volume Accumulation (Actual & Standard Conditions), Onboard Historical Storage |
| Calibration | Software-Based Pressure & Flow Calibration Functionality |
| Physical Design | Compact, Lightweight, Field-Deployable Chassis |
| Sampling Modes | Timed, Volume-Triggered (Actual or Standard), and Conditional (e.g., Workload-Based) Sampling |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-110F |
| Instrument Type | 24-hour constant-temperature and constant-flow air sampler |
| Configuration | Dual-channel gas sampler |
| Flow Range | 0.1–1.0 L/min |
| Maximum Vacuum Pressure | >25,000 Pa |
| Flow Stability | ±5% |
| Flowmeter Accuracy | ±0.1% |
| Service Life Under Max Flow & Backpressure | ≥6,000 hours |
| Operating Duration at Max Flow & Resistance | 0–24 h (±1% time accuracy) |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-110H AC/DC Dual-Channel Ambient Air Sampler |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Dual-Channel Sampling System |
| Flow Range | 0.1–1.0 L/min |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ±5% |
| Mass Flow Meter Accuracy | ±5% |
| Service Life at Max Flow & Backpressure | ≥60,000 min |
| Continuous Operation Time at Max Flow & Backpressure | ≥10 h |
| Power Supply | AC 220 V / DC Rechargeable Lithium Battery |
| Display | 4.3″ TFT Touchscreen |
| Environmental Sensors | Integrated Barometric Pressure & Ambient Temperature Measurement |
| Thermal Control | Sample Bottle Heater (activated below 20 °C) |
| Data Storage | Dual-Independent Channels, ≥200 Entries per Channel |
| Compliance | HJ/T 375–2007, JJG 956–2013 |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-110H |
| Instrument Type | 24-Hour Constant-Temperature & Constant-Flow Ambient Air Sampler |
| Sampling Configuration | Single-Channel |
| Compliance | HJ/T 375–2007, HJ/T 376–2007, JJG 956–2013, Q/WTH24–2016 |
| Display | 4.3-inch High-Brightness Color Touchscreen |
| Temperature Control | Semiconductor-Based, Maintained at 24 ± 2 °C |
| Data Storage | ≥500 sampling records per channel |
| Power Options | AC/DC Input |
| Optional Modules | Integrated GPS, Remote Status Upload (via Cellular Network), Thermal Printer Interface |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-110H |
| Instrument Type | Dual-Channel Constant-Flow Ambient Air Sampler |
| Compliance | HJ/T 375–2007, JJG 956–2013, Q/WTH 24–2016 |
| Display | 4.3-inch high-brightness color touch screen |
| Power Supply | AC/DC dual-mode with built-in rechargeable battery (≥20 h operation on battery) |
| Data Storage | ≥500 sampling records per channel |
| Environmental Parameter Measurement | Real-time ambient temperature, atmospheric pressure, pre-flowmeter pressure, and flow rate |
| Flow Control | Microprocessor-based digital flow regulation with automatic compensation |
| Optional Features | Thermal control for sampling bottles (activation <20 °C), GPS positioning, remote status/data upload via cellular network, thermal printer interface, external DC input |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-150C |
| Instrument Type | Dual-Channel Gas & TSP Sampler |
| Flow Range | 0.1–1.0 L/min (gas), 100 L/min (TSP mode) |
| Maximum Vacuum Pressure | 30 kPa |
| Flow Stability | ±5% |
| Flowmeter Accuracy | ±2.5% |
| Rated Service Life at Max Flow & Backpressure | 6,000 hours |
| Continuous Operation Time at Max Flow & Backpressure | 10 hours |
| Compliance | HJ/T 374–2007, JJG 943–2011, Q/WTH 04–2013 |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-150DII |
| Sampling Flow Range | 60–130 L/min (extendable to 180 L/min) |
| Flow Accuracy | ±2.5% of reading |
| Flow Control Resolution | 0.1 L/min |
| Flow Stability | <0.5% over time |
| Pump Service Life | >10,000 hours |
| Minimum Sustained Flow at 20 kPa Backpressure | >100 L/min |
| Data Retention | Non-volatile memory with power-loss recovery |
| Environmental Compliance | HJ 664-2013, HJ 194-2017, HJ/T 374-2007, HJ/T 375-2007, Q/WTH 04-2017 |
| Brand | Tianhong |
|---|---|
| Model | TH-150E |
| Origin | Hubei, China |
| Instrument Type | Single-Channel Gas Sampler |
| Flow Range | 10–100 L/min |
| Flow Accuracy | ±2% of setpoint |
| Flow Resolution | 0.1 L/min |
| Flow Stability | <5% deviation under variable backpressure |
| Pump Lifetime | >10,000 hours (brushless DC motor) |
| Operating Backpressure Tolerance | ≥50 L/min at −20 kPa |
| Data Retention | Non-volatile memory with power-loss recovery |
| Environmental Rating | Weather-resistant enclosure for unattended outdoor operation |
| Compliance | HJ 664-2013, HJ 194-2017, HJ/T 374-2007, HJ/T 375-2007, HJ 955-2018 |