| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Drug Encapsulation System for PLGA Nanoparticles |
| Chip Type | Single-use microfluidic chip |
| Chip Material | Glass/PDMS hybrid (biocompatible, solvent-resistant) |
| Detection Limit | Not applicable (system is a fabrication platform, not an analytical instrument) |
| Channel Dimension | 1–100 µm (customizable per application) |
| Target Payload | Hydrophobic/hydrophilic small-molecule drugs, peptides, siRNA, and other therapeutic actives encapsulated in PLGA |
| Brand | Core Separations |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Subcritical Water Extraction System |
| Price Range | USD 70,000 – 140,000 |
| Max Temperature | 400 °C |
| Max Pressure | 550 bar |
| Flow Rate Range | 5–200 g/min |
| Brand | Core Separations |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Bench Top Series |
| Price Range | USD 70,000 – 140,000 |
| Max Temperature | 150 °C |
| Max Pressure | 689 bar |
| CO₂ Mass Flow Rate | 15 g/min |
| Co-solvent Pump Pressure | 689 bar |
| Separation Method | Cyclonic Separation |
| Collection Options | Solvent Trap, Liquid Cryo-Trap, Solid-Phase Extraction Cartridge |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4010 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (optional O) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully Automated with Microprocessor Control |
| Sample Introduction | Pneumatic or Zero-Blank Electric Autosampler |
| Isotope Ratio Compatibility | Yes (for δ¹³C, δ¹⁵N, δ³⁴S, etc.) |
| Software | PC-based acquisition and reporting suite with audit trail capability |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 8020 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Measured | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Fully automated with microprocessor control and PC integration |
| Sample Introduction Options | Manual, Pneumatic, Electric Zero-Blank autosampler |
| Detector Features | Reference-gas-free TCD with auto-calibration |
| Interface Capability | IDMicro EA port for stable isotope ratio mass spectrometry (IRMS) coupling |
| Compliance Context | Designed for GLP/GMP-aligned workflows |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Polymer Nanoparticle Generation System |
| Price | USD 42,000 (FOB UK) |
| Particle Size Range | 50–500 nm |
| Polydispersity (CV) | 20–30% |
| Sample Volume Capacity | 0.5 mL – several liters |
| Wetted Materials | PEEK, PTFE, Borosilicate Glass |
| Pump Pressure Range | 0–10 bar |
| Flow Rate Range | 5 nL/min – >100 mL/min |
| Droplet/Nanoparticle Generation Frequency | up to 1 GHz (system-dependent) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | CIMPS-Pro Zennium |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A, ±10 A |
| Current Accuracy | 0.02% of reading |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V, ±20 V |
| AC Impedance Frequency Range | 10 µHz – 8 MHz |
| Brand | Dolomite |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mitios-1 |
| Pricing | Available Upon Request |
| Droplet Diameter Range | 10–250 µm |
| Droplet Generation Rate | >10,000 Hz |
| Flow Control | Independent Dual-Channel Pressure-Driven Actuation |
| Max Operating Pressure | 10 bar |
| Pump Type | Pulse-Free Pressure-Driven Microfluidic Pump |
| Chemical Resistance | High (Compatible with Organic Solvents, Acids, Bases) |
| Chip Interface | Standardized PDMS/Glass/Si Modular Cartridge Format |
| Fluid Compatibility | Aqueous, Oil, Surfactant-Stabilized, Viscous (up to 500 mPa·s) |
| Customization | Fully Configurable Chip Geometry, Channel Dimensions, Surface Chemistry, and Integration Ports |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Paeonia IR |
| Price Range | USD 1,400 – 140,000 |
| Brand | Syrris |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Atlas SonoLab |
| Usable Volume | Small-scale |
| Construction Material | Borosilicate Glass |
| Operating Pressure | Low-pressure (up to 1 bar gauge) |
| Capacity Range | 50 mL – 2 L |
| Vacuum Capability | Down to 50 mbar |
| Integrated Ultrasound System | Prosonix Flow Cell + Generator + Peristaltic Pump |
| Optional Sensors | Atlas Turbidity Probe, FBRM Particle Size Probe |
| Control Software | Atlas Platform (Windows-based, GLP-compliant) |
| Brand | Syrris |
|---|---|
| Origin | United Kingdom |
| Model | Asia Flow Photochemical Reactor |
| Temperature Range | −40 °C to +80 °C (requires optional Asia Heater or Asia Cryo Controller) |
| Temperature Setpoint Accuracy | ±1 °C, Display Resolution: 0.1 °C |
| LED Module Capacity | Up to 8 interchangeable modules per reactor |
| Wavelength Options | 365, 385, 405, 420, 450, and 525 nm (monochromatic, high-power LEDs) |
| Reaction Volumes | 4 mL or 16 mL |
| Light Power Output | Adjustable from 10% to 100% (up to 120 W total optical output) |
| Safety | Fully interlocked housing with zero-light-leak design |
| Compatibility | Integrates natively with Syrris Asia flow chemistry platforms |
| Brand | Syrris |
|---|---|
| Origin | United Kingdom |
| Model | Potassium-02 |
| Vessel Volume | 250 mL – 2 L |
| Construction Material | Borosilicate Glass |
| Operating Pressure | Low-pressure (vacuum to slight overpressure) |
| Vacuum Level | 50 mbar |
| Temperature Range | −40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C (dependent on external circulator performance) |
| Max PCC Power | 50 W |
| Max HFC Power Density | 100 W/L |
| Thermal Sensitivity | <0.1 W/kg |
| Mechanical Stirring | 0–800 rpm |
| Magnetic Stirring | 0–1200 rpm |
| Gas Inlet/Outlet Ports | Yes (inert gas compatible) |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mitos |
| Chip Type | Not Specified |
| Chip Material | Not Specified |
| Detection Limit | Not Specified |
| Channel Dimension | Not Specified |
| Analyte Range | Not Specified |
| Brand | VIALUX |
|---|---|
| Origin | Germany |
| Model | comsmart |
| Camera Resolution | 5.7 MP (standard), upgradable to 20 MP optics |
| Measurement Area (single capture) | 390 × 340 mm² |
| Node Processing Speed | 15,000 nodes/min |
| Calibration Time | ~3 min (fully automated) |
| Test Duration | 3–5 min |
| Strain Range | ≥100% (major/minor principal strain) |
| Output Formats | BMP, TIFF, PNG, JPG, VRML, PS, EPS (images) |
| Compliance | Designed for ISO/IEC 17025-aligned QA workflows, supports GLP/GMP traceability via audit-ready log export |
| Brand | Syrris |
|---|---|
| Origin | United Kingdom |
| Model | Atlas-Sodium |
| Vessel Capacities | 100 mL, 160 mL, 300 mL, 450 mL |
| Construction Material | Stainless Steel 316 (standard), optional Hastelloy or Titanium |
| Maximum Operating Pressure | 200 bar |
| Maximum Temperature | 250 °C |
| Vacuum Capability | 10 mbar |
| Stirring | Mechanical up to 800 rpm, Magnetic up to 1200 rpm |
| Gas Selection | Up to 3 gases via front-panel or PC software control |
| Pressure Control | Automated setpoint regulation with venting logic |
| Data Logging | Real-time recording of temperature, pressure, stirring speed, gas selection, and timing events |
| Safety Certification | PED 2014/68/EU and ASME BPVC Section VIII compliant |
| Optional Extensions | Custom configurations up to 350 °C, 60 bar, 10 L capacity |
| Brand | Dolomite |
|---|---|
| Origin | United Kingdom |
| Model | Mitos Dropix |
| Type | Microfluidic Droplet Coalescence Platform |
| Application Domain | Life Sciences, Synthetic Biology, High-Throughput Screening |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium XC |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.04% |
| Potential Accuracy | 100 µV |
| Potentiostatic Range | ±14 V |
| EIS Frequency Range | 10 µHz – 5 MHz |
| ADC Resolution | 32-bit |
| Voltage Resolution | 2.5 nV / 7.5 nV |
| Input Impedance | 10 TΩ (optional Hi-Z: 1000 TΩ) |
| EIS Accuracy | ±0.2% (100 mΩ–10 MΩ), ±2% (1 mΩ–100 mΩ or 10 MΩ–10 GΩ) |
| AC Perturbation Amplitude | 0–6 V (18-bit resolution) |
| Grounding Modes | Grounded & Switchable Floating Ground |
| IR Compensation | Real-time, automatic, 0–10 MΩ range |
| Bandwidth | 6 MHz |
| CV Scan Rate | up to 10,000 V/s (with ADF high-speed option) |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | Zennium X |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±4 A |
| Current Accuracy | ±0.02% of reading + ±0.01% of full scale (1 µA–100 mA), ±0.2% of reading + ±0.1% of full scale (100 mA–3 A), ±0.2% of reading + ±0.1% of full scale (10 nA–1 µA) |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| Compliance Voltage | ±32 V |
| EIS Frequency Range | 10 µHz–12 MHz |
| Frequency Accuracy | 0.0025% |
| Frequency Resolution | 10,000 steps/decade |
| Input Impedance | >10 TΩ |
| Voltage Resolution | 3 nV |
| Current Resolution | ±5 aA (32-bit DAC/ADC) |
| Bandwidth | 15 MHz |
| IR Compensation | Real-time, automatic EIS-based compensation |
| Grounding Mode | Switchable floating/grounded configuration |
| ADC/DAC Resolution | 32-bit HDP (High Dynamic Precision) architecture |
| Brand | NC Technologies |
|---|---|
| Origin | Italy |
| Model | ECS 4024 |
| Analysis Principle | High-Temperature Catalytic Combustion (Dumas Method) |
| Elements Determined | C, H, N, S (O optional) |
| Detection Method | Thermal Conductivity Detection (TCD) |
| Chromatographic Separation | Isothermal GC column (30–110 °C) |
| Automation Level | Semi-automatic |
| Software Interface | PC-based dedicated acquisition and reporting software |
| Isotope Compatibility | Compatible with IRMS (Isotope Ratio Mass Spectrometry) coupling |
| Sample Type | Homogeneous solid or liquid organic samples (micro-weighing capable) |
| Regulatory Alignment | Designed for GLP-compliant workflows |
| Brand | Zahner |
|---|---|
| Origin | Germany |
| Model | ZenniumPro |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±3 A |
| Current Resolution | ±5 aA |
| Potential Accuracy | ±50 µV |
| Potentiostatic Range | ±15 V |
| EIS Frequency Range | 10 µHz – 8 MHz |
| Input Impedance | >10 TΩ |
| ADC Resolution | 32-bit |
| Bandwidth | 10 MHz |
| Voltage Resolution | 3 nV |
| IR Compensation | Real-time, automatic |
| Grounding Modes | Switchable floating/grounded |
| Small-Signal Rise Time | 150 ns – 200 µs (5 steps) |
| Impedance Accuracy | 1 mΩ–10 GΩ (±2%), 100 mΩ–10 MΩ (±0.2%) in POT mode |
| Software | Thales XT + Zahner Analysis (EIS fitting, CIMPS, Z-HIT, NFRA) |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Prime |
| Instrument Type | Benchtop Multi-Channel Electrochemical Workstation |
| Number of Channels | 4 Independent Channels |
| Current Range per Channel | ±250 mA |
| Current Resolution | 750 fA (0.003% of range) |
| Current Accuracy | 0.1% of full scale, down to 10 nA |
| Potential Range | ±10 V |
| Potential Accuracy | ±1 mV (0.1% of range) |
| Potentiostatic/Galvanostatic/ZRA Modes | Yes |
| Input Impedance | 10 TΩ |
| ADC Resolution | 16-bit |
| Sampling Rate | 40 kS/s |
| Onboard Memory | 16 GB |
| Electrode Configurations Supported | 2-, 3-, 4-, and 5-electrode |
| Standard Cable Length | 90 cm |
| AC Impedance Frequency Range | 10 µHz – 1 MHz (typical, dependent on cell configuration) |
| Compliance | ASTM G5, G59, G102 |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | Squidstat Ace |
| Instrument Type | Portable Electrochemical Workstation |
| Number of Channels | 1 |
| Current Range | ±1 A |
| Current Resolution | 3 pA (0.003% of full scale) |
| Potential Range | ±10 V |
| Potential Resolution | 300 µV |
| Time Resolution | 10 µs |
| AC Impedance Capability | Not Supported |
| Supported DC Techniques | Cyclic Voltammetry, Linear Sweep Voltammetry, Open Circuit Potential, Chronoamperometry/Chronocoulometry, Linear Sweep Chronoamperometry, Chronopotentiometry, Differential Pulse Voltammetry, Normal Pulse Voltammetry, Square Wave Voltammetry, Relaxation Voltammetry, Staircase Voltammetry, Tafel Scan, Pulse Plating, Stripping Voltammetry |
| Supported Battery Testing Modes | Galvanostatic Charge/Discharge, Potentiostatic Charge/Discharge, Constant Resistance Discharge, Constant Power Discharge, High-Power Discharge, Capacity-Limited Cycling, Steady-State I–V Profiling |
| Brand | Admiral |
|---|---|
| Origin | USA |
| Model | Squidstat Plus |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±1 A |
| Potential Accuracy | ±300 µV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Current Resolution | 3 pA (0.003% of full scale) |
| Voltage Resolution | 300 µV |
| Data Storage | Internal 16 GB Flash Memory |
| Output Format | CSV (up to millions of data points) |
| Brand | Erichsen |
|---|---|
| Origin | Germany |
| Model | 145-60 / 145-100 |
| Maximum Punch Force | 600 kN / 1000 kN |
| Maximum Blank Holder Force | 600 kN / 1000 kN |
| Maximum Shearing Force | 700 kN / 1000 kN |
| Max. Punch Diameter | 100 mm |
| Max. Stroke | 150 mm (250 mm optional) |
| Blank Holder Stroke | 38 mm |
| Ejector Stroke | 150 mm |
| Max. Specimen Diameter | 220 mm |
| Punch Speed | up to 750 mm/min |
| Cupping Test Thickness Range | 0.1–6.0 mm |
| Deep Drawing Thickness Range | 0.2–3.0 mm (up to 6.0 mm for Model 145-100) |
| Hole Expansion Thickness Range | 0.2–3.0 mm |
| Operating Temperature | up to 550 °C (high-temp configuration available) |