| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L10001 |
| Counting Time | <10 s (manual focus), <15 s (auto-focus) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Cell Size Range | 3–60 µm (optimal: 8–30 µm) |
| Viability Range | 0–100% |
| Image Resolution | 5 MP |
| Output Formats | TIFF (annotated), PDF reports |
| Dimensions (W×D×H) | 16 × 18 × 28 cm |
| Weight | 1.6 kg |
| Power Input | 100–240 VAC, 50/60 Hz |
| DC output | 12 VDC, 3.3 A |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L30001 |
| Detection Time | 30–60 s |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm and 600 nm (long-pass) |
| Light Source | LED |
| Image Resolution | 5 MP |
| Display | 800 × 480 pixels |
| Dimensions (W×D×H) | 22 × 21 × 9 cm |
| Weight | 1.8 kg |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L20001 |
| Detection Time | 30 s (fluorescence), 10 s (brightfield) |
| Cell Concentration Range | 5 × 10⁴ – 1 × 10⁷ cells/mL |
| Sample Volume | 10 µL |
| Detectable Cell Size Range | 1–90 µm (optimized for 5–60 µm) |
| Excitation Wavelength | 470 ± 20 nm |
| Emission Wavelengths | 530 ± 25 nm (GFP), 600 nm (long-pass, RFP-compatible) |
| Light Source | High-stability LED |
| Image Resolution | 5 MP |
| Display | 800 × 480-pixel TFT LCD touchscreen |
| Dimensions (W×D×H) | 22 × 21 × 9 cm (8.6 × 8.3 × 3.5 in) |
| Weight | 1.8 kg (4 lb) |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | Q10001 |
| Detection Time | 30 s |
| Cell Concentration Range | 2 × 10⁵ to 1 × 10⁹ cells/mL |
| Sample Loading Volume | 5–6 µL |
| Measured Volume per Analysis | 0.09 µL (across 10 fields of view) |
| Detectable Cell Size Range | 0.3–50 µm |
| Brand | Aligned Genetics |
|---|---|
| Origin | South Korea |
| Model | L70001 |
| Detection Concentration Range | 1 × 10⁴ – 5 × 10⁷ cells/mL |
| Detectable Cell Size Range | 1–90 µm |
| Optical Modes | Brightfield, Dual-Fluorescence (Green: Ex 470±20 nm / Em 530±25 nm |
| Red | Ex 530±20 nm / Em 620±30 nm) |
| Autofocus | Motorized Precision Autofocus |
| Display | 7" Capacitive Touch LCD |
| Data Export | USB, Wi-Fi, Ethernet |
| Storage | 250 GB internal |
| Compliance | FDA 21 CFR Part 11 (via optional CountWire™ software) |
| Dimensions | 245 × 280 × 240 mm |
| Weight | 5.0 kg |