Empowering Scientific Discovery

Guining (Shanghai) Laboratory Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBandelin
OriginGermany
ModelPR140D
Tank Capacity5 L
Ultrasonic Frequency35 kHz
Ultrasonic Power Output120 W
Adjustable PowerYes
Adjustable TemperatureNo (PR140D) / Yes (PR140DH)
Timer Range1–30 min
Sound-Dampening LidIncluded
Drain ValveManual
Tank MaterialAISI 304 Stainless Steel
Max. Pipette Length Supported755 mm
ComplianceCE, RoHS, ISO 9001-certified manufacturing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBandelin
OriginGermany
ModelDIGITEC Series (DT/DK/RK)
TypeGeneral-purpose ultrasonic cleaner
Tank capacity0.9–90 L
Ultrasonic frequency35 kHz
Ultrasonic power output240–2400 W
Power adjustmentYes, 10–100% in 1% increments
Temperature controlYes, 20–80 °C (±1.5 °C accuracy for DIGITEC 10P
Timer1–99 min or continuous operation
Lid with acoustic dampingYes
Manual fill/drainYes
Heating elementOptional “H” variants
Safety featuresOver-temperature cutoff, boil-delay protection (selectable), low-level detection, drip-proof housing (IP32–IP33)
Tank materialStainless steel AISI 304 (1.4301) or AISI 316 (1.4571), thickness up to 2 mm
CertificationsCE, Medical Device Directive compliant (except RK 1050)
InterfaceRS232 (DIGITEC 10P), PC software support (DIGITEC 10P only)
Data storage10 programmable cleaning protocols (DIGITEC 10P)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBandelin
OriginGermany
ModelSONOREX RK1028H
Tank Volume5.5 L
Heating Power280 W
Operating Frequency35 kHz
External Dimensions (L×W×D)325 × 175 × 295 mm
Temperature RangeAmbient to 60 °C (heated operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBandelin
OriginGermany
ModelDT 1028F
Bath Volume35 L
Temperature Range0–100 °C
Temperature Stability±1 °C
Circulation TypeInternal & External
Oscillation Platform Dimensions410 × 280 mm (L × W)
Maximum Load Capacity36 × 10 mL vials, 36 × 25 mL vials, 18 × 50 mL vials, 12 × 100 mL vials, or 10 × 250 mL Erlenmeyer flasks
Ultrasonic Power (Peak / Nominal)1280 W / 320 W
Amplitude20 mm (load-independent)
Reciprocating Motion4-step programmable
Drain ValveYes
Optional ClampEK10–250 (sold separately)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBandelin
OriginGermany
ModelDL102H
Chamber Volume3 L
Heating Power120 W
Operating TemperatureAmbient (non-heated mode)
Cleaning Solution CompatibilitySingle-solution compatible
External Dimensions (L×W×D)260 × 160 × 250 mm
Ultrasonic Peak Power480 W
Nominal Ultrasonic Power120 W
Drain ValveIntegrated ball valve
Front Panel MaterialAnodized aluminum foil
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASA-03RXD
Imaging PrincipleCCD-based 30° parallel-light profilometry
Sample TypeSilicone replica
Quantitative OutputWrinkle count, volume (triangular cross-section model), depth, width, area ratio, texture parameters (Rz, Rt), 3D surface visualization
ComplianceJSCA Guideline for Evaluation of Anti-Wrinkle Products
Software PlatformWindows 10 native application with calibration, edge enhancement, and XY/depth conversion modules
Optional ModulesSebum measurement kit (ASS-001 SEBU patch + absorbance analysis software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-GP1
Measurement PrincipleDual-finger-type quasi-static compression with real-time viscoelastic force feedback
Sensor TypeLightweight, bidirectional tactile probes with adjustable clamping displacement and dwell time
Output ParametersMaximum Stress (kPa), Skin Hardness Index, Elastic Recoil Ratio (%), Viscoelastic Relaxation Time Constant (s), Collagen Aging Index (unitless derived metric), Initial Rebound Velocity (mm/s), Sagging Index (normalized strain recovery deficit)
ComplianceDesigned for GLP-aligned dermatological research workflows
Software InterfacePC-based acquisition with waveform visualization, timestamped data export (CSV, PNG), and multi-point protocol storage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsahi Spectra
OriginJapan
ModelHAL-320
Light Source300 W Xenon Arc Lamp
Spectral Range350–1100 nm
Spectral Match ClassJIS/IEC Class A (AM1.5G)
Spatial Uniformity≤±2% (over 30×30 mm, ND-filtered)
Temporal Stability≤±1% (over 1 h, RMS)
Illumination ModeSteady-State
Control InterfaceRS232C
Power InputAC 90–264 V, 50/60 Hz
Max Power Consumption<510 VA
CoolingForced Air
Lamp Lifetime500 h (avg.)
Dimensions (Host)200 × 300 × 292 mm
Weight (Host)11.3 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-TZ1
Measurement PrincipleLow-frequency AC impedance
Impedance Range0.5–99 kΩ
Phase Angle Range0–90°
Repeatability±2% (0.1–10 kΩ), ±1% (10–99 kΩ)
Excitation Voltage5 V DC
Test Frequency12 Hz
ElectrodesAg/AgCl (donor side), Ag (receiver side)
Display65 × 15 mm LCD
Dimensions190 × 60 × 200 mm
Power Supply6 V DC (battery-operated)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAsahi Spectra
OriginJapan
ModelMAX-350
Output Wavelength Range250–1050 nm (dependent on mirror module)
Light Output Intensity0–900 mW/cm² (spectrally dependent, continuously adjustable)
Light SourceCermax® 300W xenon arc lamp
Lamp Lifetime≥500 h
Cooling MethodForced-air cooling
Shutter TypePulsed motor-driven, exposure time 0.5 s – 24 h
ND Attenuation1000–50 steps (continuous)
Filter Wheel8-position, accepts 25 mm diameter × <6 mm thick filters
Mirror ModulesUV (250–385 nm), UV-VIS (300–600 nm), VIS (385–740 nm), IR (750–1050 nm)
Control InterfaceBuilt-in touchscreen + RS-485 remote control
Safety FeaturesLamp fault detection, fan failure monitoring, thermal overheat protection
Operating Environment10–35 °C, 20–80% RH (non-condensing)
Dimensions196 × 330 × 302 mm (W×D×H)
Weight12.2 kg
Power InputAC 100–240 V, 50/60 Hz
Max Power Consumption<540 VA (100 V/50 Hz), <520 VA (240 V/50 Hz)
Beam AlignmentAlignment-free (integrated optical housing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelCMSN-141
Instrument TypeBenchtop
Parameters MeasuredpH and mV
Measurement Accuracy±0.01 pH
pH Range4.0–9.0
Resolution0.01 pH
Calibration BufferspH 4.01 and 6.86
Electrode Tip Diameter0.65 mm
Sensing ElementAntimony
Operating Temperature0–60 °C
Reference ElectrodeCMR-545 (BNC, stainless steel body)
Salt BridgeSB-010
Cable Length1.0 m
Liquid JunctionNone
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelCL-9D02
Instrument TypeBenchtop
Parameters MeasuredpH and Temperature
pH Accuracy±0.01 pH
pH Range (Glass Electrode)0.00–14.00
pH Range (Antimony Electrode)4.00–9.00
Resolution0.01 pH
Temperature CompensationAutomatic & Manual (0–100 °C)
Input Impedance>10¹³ Ω
Output Signal0–1.4 V / ±1999 mV
Power Supply220 V, 50/60 Hz
Power Consumption~1.0 VA
Dimensions165(W) × 180(D) × 70(H) mm
Weight~1000 g
Compatible ElectrodeMCS-30S Antimony Composite Electrode
Minimum Sample Volume50–1000 µL
Calibration BufferspH 4.01 and 6.86
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASA-MX100
Measurement PrincipleConductivity-based Corneal Hydration & Transepidermal Electrical Resistance (TEER)
Probe TypesC3D-MX (3D skin models), R2-MX (scalp), T4-MX (nail)
Measurement Time5 s per reading
Electrode ConfigurationSeparated excitation/detection electrodes
Output InterfaceRS-232 digital port
CalibrationFully digital one-button calibration
ComplianceDesigned for GLP-compliant dermatological research and cosmetic efficacy testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASE
OriginJapan
ModelLHT-04
Measurement PrincipleVentilated Capsule Method
Measurement Range0.00–3.00 mg/cm²/min (at 30 °C, 40 % RH)
Accuracy±10 %
Response Time1 s
Measurement Area1 cm²
Channel Count1
Probe Length0.9 m (standard), up to 1.2 m (optional)
Data Logging Duration4 h
Power Supply2 × AA batteries
Operating Temperature15–35 °C
Operating Humidity40–60 % RH
Dimensions (W×H×D)76 × 35 × 135 mm
Weight350 g
ComplianceDesigned for ISO 9241-305 (human thermal comfort), ASTM E1980 (sweat rate in physiological testing), and GLP-aligned data integrity workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelAS-VT100RS
Measurement PrincipleClosed-chamber dynamic humidity gradient analysis
TEWL Range0–300 g/m²/h
Resolution0.1 g/m²/h
Measurement Time5–14 s
Probe Aperture Options6, 8, 10, or 12 mm (DIP-switch configurable)
Dimensions165 × 70 × 28 mm
Weight200 g
Power SupplyAC adapter or AA batteries
Environmental MonitoringIntegrated temperature & relative humidity sensors
Data OutputRS-232 serial interface
Sample TypesHuman skin (in vivo), excised animal skin (rat, pig, rabbit), 3D reconstructed human epidermis (RHE), and cultured skin models
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelCM-191
Measurement PrincipleAntimony Electrode Potentiometry (pH 4.00–9.00) & Glass Electrode Potentiometry (pH 0.00–14.00)
Temperature CompensationAutomatic/Manual (0°C to 100°C)
Input Impedance>10¹³ Ω
Resolution0.01 pH / 1 mV
Accuracy (pH)±0.01 pH
Accuracy (mV)±1 mV
DisplayDigital LCD
Power SupplyAC 100 V, 50/60 Hz (12 V DC adapter)
Power Consumption~1 VA
Dimensions (W×D×H)165 × 180 × 70 mm
Weight~1000 g
Data Output0–1.4 V analog signal (compatible with external data loggers)
Standard AccessoriespH 4.01 & 6.86 calibration buffers (1× each), 12 V AC adapter, 0–100°C thermometer
Optional ElectrodesCMS-191 antimony micro-catheter electrode (1.0 mm OD), CM-181 glass electrode (2.4 mm OD)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandASCH
OriginJapan
ModelASP-02
Measurement Range0–9 pH
Resolution0.1 pH
Accuracy±0.2 pH
Response Time≤10 s
CalibrationTwo-point with pH 4.0 and pH 7.0 standard buffers
Operating Temperature0–50 °C
Storage Environment5–50 °C, 5–85% RH (non-condensing)
Power Supply2 × AA alkaline batteries
Main Unit Dimensions122 × 80 × 33.5 mm (H×W×D)
Main Unit Weight~200 g
Electrode Dimensions135 mm length × φ12 mm diameter
Cable Length1 m
Electrode Weight~60 g
Sample InterfaceFlat-surface combination pH electrode for direct skin contact
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcroEdge
OriginJapan
ModelCurea
Excitation Wavelength365 nm
Spot Diameter2 mm
Working Distance43 mm
Measurement Time0.1 s
Dimensions (W×D×H)50×75×125 mm
Weight~900 g
ApplicationReal-time non-contact UV-curable resin cure monitoring
Added to wishlistRemoved from wishlist 0
Add to compare
KeyBrand: AcroEdge
ModelStency
OriginImported
Force Range1–20 N (configurable)
Force Accuracy±0.1% F.S.
Displacement Resolution0.01 mm
Maximum Stroke60 mm (uniaxial)
Positioning Accuracy±0.02 mm
Test Speed0.1–100 mm/s
Data Acquisition Rate10 Hz (100 ms interval)
Max Data Points per Test60,000
Sample Widthup to 50 mm (biaxial), 30 mm (uniaxial)
Sample Length≥5 mm + gauge length
Power SupplyAC 100 V ±10%, 2–3 A
Operating Temperature0–40 °C
ComplianceDesigned for ASTM D638, ISO 527, and ISO 11843-compliant tensile evaluation of micro-scale specimens
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcroEdge
OriginJapan
ModelEU201
Measurement PrincipleLaser Displacement + Load Cell-Based Stress Monitoring
Temperature Control Range–50 °C to 300 °C (programmable ramp/soak)
Laser Source655 nm Class 1 semiconductor diode (220 µW)
Displacement Resolution2 µm
Force Sensing Range5 N (standard), optional ranges: 500 mN, 1 N, 2 N, 10 N, 20 N
Force Nonlinearity±0.5 % RO
Force Repeatability±0.5 % RO
Heating Power450 W (3×50 W elements)
Cooling Unit Capacity450 W (10–25 °C adjustable)
Sample Volume~1 mL
ComplianceISO 4216:2021, JIS K6941:2019
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcroEdge
OriginJapan
ModelEU501
Laser Wavelength655 nm (red semiconductor, visible)
Laser ClassFDA CDRH 21 CFR Part 1040.10 Class 2
Output Power220 μW
Thickness Measurement Repeatability±2 μm
Sample Volume Requirement< 5 mL
Host Dimensions (mm)W130 × D150 × H105
Detector Dimensions (mm)W120 × D165 × H180
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAcroEdge
OriginImported
Manufacturer TypeAuthorized Distributor
ModelSyclus
Instrument CategoryCompact Vibration-Based Fatigue Tester
Frequency Range1–20 Hz
Maximum Displacement Amplitude±600 µm
Load Capacity±25 N (±0.5% nonlinearity)
Sample DimensionsLength 25–35 mm
GeometryFilms, Fibers, Thin Specimens
Control InterfaceUSB-connected PC with Dedicated Software
Sampling RateUp to 2000 pts/sec
Data Storage ModesLinear (N cycles per T minutes) or Logarithmic (10, 100, 1000, …, 10ⁿ cycles)
Failure DetectionProgrammable load threshold trigger with pre-failure cycle preservation (3 cycles prior to failure)
System Dimensions (Tester)L100 × W100 × H500 mm (vertical orientation)
Controller DimensionsL250 × W250 × H150 mm
Tester Mass~3 kg
Controller Mass~5 kg
Power Supply100 V, 10 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandA.KRÜSS / A.KRÜSS Optronic
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelAR4
Product TypeBenchtop Abbe Refractometer
Temperature ControlYes
Digital DisplayNo
Measurement Range1.3000 – 1.7000 nD
Accuracy±0.0002 nD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandA.KRÜSS / A.KRÜSS Optronic
OriginGermany
ModelDR301-95
Sample Measurement Range1.3330–1.5318 nD
Measurement Accuracy±0.00015 nD
Temperature Range5–40 °C
Temperature Accuracy±0.5 °C
Resolution0.0001 nD
DisplayDigital LCD
Power Supply9 V battery (detachable AC adapter optional)
Prism MaterialOptical glass
Housing MaterialStainless steel sample stage + polymer body
Dimensions180 × 100 × 60 mm
Weight500 g
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0