| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | PR140D |
| Tank Capacity | 5 L |
| Ultrasonic Frequency | 35 kHz |
| Ultrasonic Power Output | 120 W |
| Adjustable Power | Yes |
| Adjustable Temperature | No (PR140D) / Yes (PR140DH) |
| Timer Range | 1–30 min |
| Sound-Dampening Lid | Included |
| Drain Valve | Manual |
| Tank Material | AISI 304 Stainless Steel |
| Max. Pipette Length Supported | 755 mm |
| Compliance | CE, RoHS, ISO 9001-certified manufacturing |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | DIGITEC Series (DT/DK/RK) |
| Type | General-purpose ultrasonic cleaner |
| Tank capacity | 0.9–90 L |
| Ultrasonic frequency | 35 kHz |
| Ultrasonic power output | 240–2400 W |
| Power adjustment | Yes, 10–100% in 1% increments |
| Temperature control | Yes, 20–80 °C (±1.5 °C accuracy for DIGITEC 10P |
| Timer | 1–99 min or continuous operation |
| Lid with acoustic damping | Yes |
| Manual fill/drain | Yes |
| Heating element | Optional “H” variants |
| Safety features | Over-temperature cutoff, boil-delay protection (selectable), low-level detection, drip-proof housing (IP32–IP33) |
| Tank material | Stainless steel AISI 304 (1.4301) or AISI 316 (1.4571), thickness up to 2 mm |
| Certifications | CE, Medical Device Directive compliant (except RK 1050) |
| Interface | RS232 (DIGITEC 10P), PC software support (DIGITEC 10P only) |
| Data storage | 10 programmable cleaning protocols (DIGITEC 10P) |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | SONOREX RK1028H |
| Tank Volume | 5.5 L |
| Heating Power | 280 W |
| Operating Frequency | 35 kHz |
| External Dimensions (L×W×D) | 325 × 175 × 295 mm |
| Temperature Range | Ambient to 60 °C (heated operation) |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | DT 1028F |
| Bath Volume | 35 L |
| Temperature Range | 0–100 °C |
| Temperature Stability | ±1 °C |
| Circulation Type | Internal & External |
| Oscillation Platform Dimensions | 410 × 280 mm (L × W) |
| Maximum Load Capacity | 36 × 10 mL vials, 36 × 25 mL vials, 18 × 50 mL vials, 12 × 100 mL vials, or 10 × 250 mL Erlenmeyer flasks |
| Ultrasonic Power (Peak / Nominal) | 1280 W / 320 W |
| Amplitude | 20 mm (load-independent) |
| Reciprocating Motion | 4-step programmable |
| Drain Valve | Yes |
| Optional Clamp | EK10–250 (sold separately) |
| Brand | Bandelin |
|---|---|
| Origin | Germany |
| Model | DL102H |
| Chamber Volume | 3 L |
| Heating Power | 120 W |
| Operating Temperature | Ambient (non-heated mode) |
| Cleaning Solution Compatibility | Single-solution compatible |
| External Dimensions (L×W×D) | 260 × 160 × 250 mm |
| Ultrasonic Peak Power | 480 W |
| Nominal Ultrasonic Power | 120 W |
| Drain Valve | Integrated ball valve |
| Front Panel Material | Anodized aluminum foil |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-03RXD |
| Imaging Principle | CCD-based 30° parallel-light profilometry |
| Sample Type | Silicone replica |
| Quantitative Output | Wrinkle count, volume (triangular cross-section model), depth, width, area ratio, texture parameters (Rz, Rt), 3D surface visualization |
| Compliance | JSCA Guideline for Evaluation of Anti-Wrinkle Products |
| Software Platform | Windows 10 native application with calibration, edge enhancement, and XY/depth conversion modules |
| Optional Modules | Sebum measurement kit (ASS-001 SEBU patch + absorbance analysis software) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-GP1 |
| Measurement Principle | Dual-finger-type quasi-static compression with real-time viscoelastic force feedback |
| Sensor Type | Lightweight, bidirectional tactile probes with adjustable clamping displacement and dwell time |
| Output Parameters | Maximum Stress (kPa), Skin Hardness Index, Elastic Recoil Ratio (%), Viscoelastic Relaxation Time Constant (s), Collagen Aging Index (unitless derived metric), Initial Rebound Velocity (mm/s), Sagging Index (normalized strain recovery deficit) |
| Compliance | Designed for GLP-aligned dermatological research workflows |
| Software Interface | PC-based acquisition with waveform visualization, timestamped data export (CSV, PNG), and multi-point protocol storage |
| Brand | Asahi Spectra |
|---|---|
| Origin | Japan |
| Model | HAL-320 |
| Light Source | 300 W Xenon Arc Lamp |
| Spectral Range | 350–1100 nm |
| Spectral Match Class | JIS/IEC Class A (AM1.5G) |
| Spatial Uniformity | ≤±2% (over 30×30 mm, ND-filtered) |
| Temporal Stability | ≤±1% (over 1 h, RMS) |
| Illumination Mode | Steady-State |
| Control Interface | RS232C |
| Power Input | AC 90–264 V, 50/60 Hz |
| Max Power Consumption | <510 VA |
| Cooling | Forced Air |
| Lamp Lifetime | 500 h (avg.) |
| Dimensions (Host) | 200 × 300 × 292 mm |
| Weight (Host) | 11.3 kg |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-TZ1 |
| Measurement Principle | Low-frequency AC impedance |
| Impedance Range | 0.5–99 kΩ |
| Phase Angle Range | 0–90° |
| Repeatability | ±2% (0.1–10 kΩ), ±1% (10–99 kΩ) |
| Excitation Voltage | 5 V DC |
| Test Frequency | 12 Hz |
| Electrodes | Ag/AgCl (donor side), Ag (receiver side) |
| Display | 65 × 15 mm LCD |
| Dimensions | 190 × 60 × 200 mm |
| Power Supply | 6 V DC (battery-operated) |
| Brand | Asahi Spectra |
|---|---|
| Origin | Japan |
| Model | MAX-350 |
| Output Wavelength Range | 250–1050 nm (dependent on mirror module) |
| Light Output Intensity | 0–900 mW/cm² (spectrally dependent, continuously adjustable) |
| Light Source | Cermax® 300W xenon arc lamp |
| Lamp Lifetime | ≥500 h |
| Cooling Method | Forced-air cooling |
| Shutter Type | Pulsed motor-driven, exposure time 0.5 s – 24 h |
| ND Attenuation | 1000–50 steps (continuous) |
| Filter Wheel | 8-position, accepts 25 mm diameter × <6 mm thick filters |
| Mirror Modules | UV (250–385 nm), UV-VIS (300–600 nm), VIS (385–740 nm), IR (750–1050 nm) |
| Control Interface | Built-in touchscreen + RS-485 remote control |
| Safety Features | Lamp fault detection, fan failure monitoring, thermal overheat protection |
| Operating Environment | 10–35 °C, 20–80% RH (non-condensing) |
| Dimensions | 196 × 330 × 302 mm (W×D×H) |
| Weight | 12.2 kg |
| Power Input | AC 100–240 V, 50/60 Hz |
| Max Power Consumption | <540 VA (100 V/50 Hz), <520 VA (240 V/50 Hz) |
| Beam Alignment | Alignment-free (integrated optical housing) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CMSN-141 |
| Instrument Type | Benchtop |
| Parameters Measured | pH and mV |
| Measurement Accuracy | ±0.01 pH |
| pH Range | 4.0–9.0 |
| Resolution | 0.01 pH |
| Calibration Buffers | pH 4.01 and 6.86 |
| Electrode Tip Diameter | 0.65 mm |
| Sensing Element | Antimony |
| Operating Temperature | 0–60 °C |
| Reference Electrode | CMR-545 (BNC, stainless steel body) |
| Salt Bridge | SB-010 |
| Cable Length | 1.0 m |
| Liquid Junction | None |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CL-9D02 |
| Instrument Type | Benchtop |
| Parameters Measured | pH and Temperature |
| pH Accuracy | ±0.01 pH |
| pH Range (Glass Electrode) | 0.00–14.00 |
| pH Range (Antimony Electrode) | 4.00–9.00 |
| Resolution | 0.01 pH |
| Temperature Compensation | Automatic & Manual (0–100 °C) |
| Input Impedance | >10¹³ Ω |
| Output Signal | 0–1.4 V / ±1999 mV |
| Power Supply | 220 V, 50/60 Hz |
| Power Consumption | ~1.0 VA |
| Dimensions | 165(W) × 180(D) × 70(H) mm |
| Weight | ~1000 g |
| Compatible Electrode | MCS-30S Antimony Composite Electrode |
| Minimum Sample Volume | 50–1000 µL |
| Calibration Buffers | pH 4.01 and 6.86 |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASA-MX100 |
| Measurement Principle | Conductivity-based Corneal Hydration & Transepidermal Electrical Resistance (TEER) |
| Probe Types | C3D-MX (3D skin models), R2-MX (scalp), T4-MX (nail) |
| Measurement Time | 5 s per reading |
| Electrode Configuration | Separated excitation/detection electrodes |
| Output Interface | RS-232 digital port |
| Calibration | Fully digital one-button calibration |
| Compliance | Designed for GLP-compliant dermatological research and cosmetic efficacy testing |
| Brand | ASE |
|---|---|
| Origin | Japan |
| Model | LHT-04 |
| Measurement Principle | Ventilated Capsule Method |
| Measurement Range | 0.00–3.00 mg/cm²/min (at 30 °C, 40 % RH) |
| Accuracy | ±10 % |
| Response Time | 1 s |
| Measurement Area | 1 cm² |
| Channel Count | 1 |
| Probe Length | 0.9 m (standard), up to 1.2 m (optional) |
| Data Logging Duration | 4 h |
| Power Supply | 2 × AA batteries |
| Operating Temperature | 15–35 °C |
| Operating Humidity | 40–60 % RH |
| Dimensions (W×H×D) | 76 × 35 × 135 mm |
| Weight | 350 g |
| Compliance | Designed for ISO 9241-305 (human thermal comfort), ASTM E1980 (sweat rate in physiological testing), and GLP-aligned data integrity workflows |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | AS-VT100RS |
| Measurement Principle | Closed-chamber dynamic humidity gradient analysis |
| TEWL Range | 0–300 g/m²/h |
| Resolution | 0.1 g/m²/h |
| Measurement Time | 5–14 s |
| Probe Aperture Options | 6, 8, 10, or 12 mm (DIP-switch configurable) |
| Dimensions | 165 × 70 × 28 mm |
| Weight | 200 g |
| Power Supply | AC adapter or AA batteries |
| Environmental Monitoring | Integrated temperature & relative humidity sensors |
| Data Output | RS-232 serial interface |
| Sample Types | Human skin (in vivo), excised animal skin (rat, pig, rabbit), 3D reconstructed human epidermis (RHE), and cultured skin models |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | CM-191 |
| Measurement Principle | Antimony Electrode Potentiometry (pH 4.00–9.00) & Glass Electrode Potentiometry (pH 0.00–14.00) |
| Temperature Compensation | Automatic/Manual (0°C to 100°C) |
| Input Impedance | >10¹³ Ω |
| Resolution | 0.01 pH / 1 mV |
| Accuracy (pH) | ±0.01 pH |
| Accuracy (mV) | ±1 mV |
| Display | Digital LCD |
| Power Supply | AC 100 V, 50/60 Hz (12 V DC adapter) |
| Power Consumption | ~1 VA |
| Dimensions (W×D×H) | 165 × 180 × 70 mm |
| Weight | ~1000 g |
| Data Output | 0–1.4 V analog signal (compatible with external data loggers) |
| Standard Accessories | pH 4.01 & 6.86 calibration buffers (1× each), 12 V AC adapter, 0–100°C thermometer |
| Optional Electrodes | CMS-191 antimony micro-catheter electrode (1.0 mm OD), CM-181 glass electrode (2.4 mm OD) |
| Brand | ASCH |
|---|---|
| Origin | Japan |
| Model | ASP-02 |
| Measurement Range | 0–9 pH |
| Resolution | 0.1 pH |
| Accuracy | ±0.2 pH |
| Response Time | ≤10 s |
| Calibration | Two-point with pH 4.0 and pH 7.0 standard buffers |
| Operating Temperature | 0–50 °C |
| Storage Environment | 5–50 °C, 5–85% RH (non-condensing) |
| Power Supply | 2 × AA alkaline batteries |
| Main Unit Dimensions | 122 × 80 × 33.5 mm (H×W×D) |
| Main Unit Weight | ~200 g |
| Electrode Dimensions | 135 mm length × φ12 mm diameter |
| Cable Length | 1 m |
| Electrode Weight | ~60 g |
| Sample Interface | Flat-surface combination pH electrode for direct skin contact |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | Curea |
| Excitation Wavelength | 365 nm |
| Spot Diameter | 2 mm |
| Working Distance | 43 mm |
| Measurement Time | 0.1 s |
| Dimensions (W×D×H) | 50×75×125 mm |
| Weight | ~900 g |
| Application | Real-time non-contact UV-curable resin cure monitoring |
| Key | Brand: AcroEdge |
|---|---|
| Model | Stency |
| Origin | Imported |
| Force Range | 1–20 N (configurable) |
| Force Accuracy | ±0.1% F.S. |
| Displacement Resolution | 0.01 mm |
| Maximum Stroke | 60 mm (uniaxial) |
| Positioning Accuracy | ±0.02 mm |
| Test Speed | 0.1–100 mm/s |
| Data Acquisition Rate | 10 Hz (100 ms interval) |
| Max Data Points per Test | 60,000 |
| Sample Width | up to 50 mm (biaxial), 30 mm (uniaxial) |
| Sample Length | ≥5 mm + gauge length |
| Power Supply | AC 100 V ±10%, 2–3 A |
| Operating Temperature | 0–40 °C |
| Compliance | Designed for ASTM D638, ISO 527, and ISO 11843-compliant tensile evaluation of micro-scale specimens |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU201 |
| Measurement Principle | Laser Displacement + Load Cell-Based Stress Monitoring |
| Temperature Control Range | –50 °C to 300 °C (programmable ramp/soak) |
| Laser Source | 655 nm Class 1 semiconductor diode (220 µW) |
| Displacement Resolution | 2 µm |
| Force Sensing Range | 5 N (standard), optional ranges: 500 mN, 1 N, 2 N, 10 N, 20 N |
| Force Nonlinearity | ±0.5 % RO |
| Force Repeatability | ±0.5 % RO |
| Heating Power | 450 W (3×50 W elements) |
| Cooling Unit Capacity | 450 W (10–25 °C adjustable) |
| Sample Volume | ~1 mL |
| Compliance | ISO 4216:2021, JIS K6941:2019 |
| Brand | AcroEdge |
|---|---|
| Origin | Japan |
| Model | EU501 |
| Laser Wavelength | 655 nm (red semiconductor, visible) |
| Laser Class | FDA CDRH 21 CFR Part 1040.10 Class 2 |
| Output Power | 220 μW |
| Thickness Measurement Repeatability | ±2 μm |
| Sample Volume Requirement | < 5 mL |
| Host Dimensions (mm) | W130 × D150 × H105 |
| Detector Dimensions (mm) | W120 × D165 × H180 |
| Brand | AcroEdge |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Syclus |
| Instrument Category | Compact Vibration-Based Fatigue Tester |
| Frequency Range | 1–20 Hz |
| Maximum Displacement Amplitude | ±600 µm |
| Load Capacity | ±25 N (±0.5% nonlinearity) |
| Sample Dimensions | Length 25–35 mm |
| Geometry | Films, Fibers, Thin Specimens |
| Control Interface | USB-connected PC with Dedicated Software |
| Sampling Rate | Up to 2000 pts/sec |
| Data Storage Modes | Linear (N cycles per T minutes) or Logarithmic (10, 100, 1000, …, 10ⁿ cycles) |
| Failure Detection | Programmable load threshold trigger with pre-failure cycle preservation (3 cycles prior to failure) |
| System Dimensions (Tester) | L100 × W100 × H500 mm (vertical orientation) |
| Controller Dimensions | L250 × W250 × H150 mm |
| Tester Mass | ~3 kg |
| Controller Mass | ~5 kg |
| Power Supply | 100 V, 10 A |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | AR4 |
| Product Type | Benchtop Abbe Refractometer |
| Temperature Control | Yes |
| Digital Display | No |
| Measurement Range | 1.3000 – 1.7000 nD |
| Accuracy | ±0.0002 nD |
| Brand | A.KRÜSS / A.KRÜSS Optronic |
|---|---|
| Origin | Germany |
| Model | DR301-95 |
| Sample Measurement Range | 1.3330–1.5318 nD |
| Measurement Accuracy | ±0.00015 nD |
| Temperature Range | 5–40 °C |
| Temperature Accuracy | ±0.5 °C |
| Resolution | 0.0001 nD |
| Display | Digital LCD |
| Power Supply | 9 V battery (detachable AC adapter optional) |
| Prism Material | Optical glass |
| Housing Material | Stainless steel sample stage + polymer body |
| Dimensions | 180 × 100 × 60 mm |
| Weight | 500 g |