- All
- Favorite
- Popular
- Most rated
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | HM-3000A |
| Maximum Operating Temperature | 825 °C ± 50 °C |
| Heating Power | 170 W |
| Chamber Dimensions (W×D×H) | 98 mm × 185 mm × 190 mm |
| Max. Sample Diameter | Φ14 mm |
| Heating Zone Length | 150 mm |
| Net Weight | 1.3 kg |
| Input Voltage | AC 220 V / AC 120 V, 50/60 Hz, 1 A |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Gene-8C |
| Sample Capacity | 8 × 0.2 mL wells (compatible with 8-tube strips) |
| Reaction Volume | 20–100 µL (recommended: 25–30 µL) |
| Excitation Wavelength F1 | 470/30 nm |
| Emission Wavelength F1 | 535/20 nm |
| Light Source | High-stability LED |
| Detection Method | Real-time fluorescence monitoring |
| Temperature Range | Ambient to 99 °C |
| Max Heating/Cooling Rate | 2 °C/s |
| Temperature Uniformity | ±0.15 °C |
| Temperature Accuracy | ±0.1 °C |
| Thermal Lid | Integrated |
| Display | 7-inch capacitive touchscreen |
| Power Supply | 100–240 VAC, 50–60 Hz |
| Dimensions (W×D×H) | 145 × 305 × 100 mm |
| Weight (without battery) | 2.3 kg |
| Compatible Dyes | FAM/SYBR Green I, HEX/VIC/JOE |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 96 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 (also supports 1–24 configuration) |
| Sample Volume Range | 50–1000 µL and 50–10000 µL |
| Processing Time per Batch | 30–60 minutes |
| Heating Capability | 2 of 8 plate positions with precision temperature control (RT to 120 °C) |
| Display | 7-inch color touchscreen interface |
| Onboard Data Storage | Internal SD card |
| Connectivity | USB, Ethernet, optional Wi-Fi |
| UV Sterilization | Integrated |
| Cross-Contamination Control | Anti-drip baffle, disposable consumables, automated magnetic rod sleeve loading/unloading, barcode recognition |
| Reproducibility | CV < 5% across wells |
| Sensitivity | >95% positive detection rate for samples containing ≥100 copies |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Esan-Gene 696 / Esan-Gene 696A |
| Sample Format | 696 — 0.2 mL tubes & 96-well plates |
| Reaction Volume | 10–100 µL |
| Optical Channels | 6 (F1: FAM/SYBR Green I |
| F2 | HEX/JOE/VIC |
| F3 | ROX/Texas Red |
| F4 | Cy5/Quasar-670 |
| F5 | Cy5.5 |
| F6 | user-definable, default FRET) |
| Dynamic Range | 10⁰–10¹⁰ copies/µL |
| LOD | 1 copy |
| Ct Reproducibility | CV ≤ 1% |
| Temperature Range | 4–99.9 °C |
| Heating Rate | 3.5 °C/s (avg) |
| Cooling Rate | 2.5 °C/s (avg) |
| Block Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Precision | 0.1 °C |
| Melting Resolution | 0.1 °C |
| Gradient Range | 1–40 °C across 6 zones |
| Heat Lid Temp | 30–110 °C |
| Display | 10.1″ LVDS capacitive touchscreen |
| Interfaces | USB-A ×3, LAN ×1 |
| Data Export | Excel, PDF |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Esan-Gene 164 Real-Time Fluorescent Quantitative PCR System |
| Quotation | Available Upon Request |
| Throughput | 16-well (0.2 mL tubes or 8-tube strips) |
| Sample Volume Range | 10–100 µL |
| Dynamic Range | 1–10¹⁰ copies |
| Excitation Source | High-Stability LED |
| Detection Channels | 4 (F1: 515–535 nm |
| F2 | 535–555 nm |
| F3 | 600–620 nm |
| F4 | 665–695 nm) |
| Fluorescence Detection Range | 400–770 nm |
| Detector Type | Photodiode (PD) |
| Block Temperature Range | 4–99 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Uniformity | ±0.2 °C @ 95 °C |
| Max Heating Rate | 4.0 °C/s |
| Max Cooling Rate | 3.0 °C/s |
| Melting Curve Resolution | 0.1 °C |
| Heat Lid Temperature Range | 30–110 °C (default: block +10 °C) |
| Heat Lid Accuracy | ±2 °C |
| Power Supply | 220 V AC, 50 Hz |
| Max Power Consumption | 200 W |
| Dimensions (W×D×H) | 200 × 207 × 148 mm |
| Weight | <3.5 kg |
| Operating System | Embedded Windows-based UI |
| Display | 7-inch capacitive touchscreen |
| Connectivity | USB 2.0, Ethernet, optional direct thermal printer interface |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TD2-24 |
| Quotation | Upon Request |
| Speed Range | 500–1500 rpm |
| RCF Range | 33–294 × g |
| Capacity | 24 columns (6- or 8-column immunohematology cards) |
| Timer Range | 1–20 min |
| Noise Level | ≤55 dB(A) |
| Power Supply | AC 100–240 V, 50/60 Hz, 3 A |
| Power Consumption | 85 W |
| Dimensions (L×W×H) | 530 × 410 × 180 mm |
| Weight | 11.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 48 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–48 |
| Sample Volume Range | 200–3000 µL |
| Processing Time per Batch | 15 min |
| Heating Positions | 2 of 8 plate stations |
| Lysis & Elution Temperature Range | Ambient to 120 °C |
| Inter-Well CV | <5% |
| Detection Sensitivity | >95% positive detection rate for 100-copy samples |
| Display | 7-inch color touchscreen |
| Internal Storage | SD card |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Au-Shaker 5012L/3020L/2030L |
| Rotation Speed Range | 200–5000 rpm / 200–3000 rpm / 200–2000 rpm |
| Orbital Diameter | 1.2 mm / 2.0 mm / 3.0 mm |
| Timing Range | 99 h 59 min or 99 min 59 s |
| Speed Accuracy | ±7.5 rpm |
| Acceleration Time | 1–10 s |
| Zero-Positioning Accuracy | ±0.1 mm |
| Auto-Clamping Positioning Accuracy | ±0.1 mm |
| Power Input | 24 V DC, 48 W |
| Communication Interface | DB9 connector, CAN bus protocol |
| Dimensions (W×D×H) | 142 × 105 × 94 mm |
| Weight | 1.8 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Pure S24/H24 |
| Principle | Magnetic Bead-Based Extraction with Pipetting & Magnetic Rod Transfer |
| Sample Throughput | 1–24 samples per run |
| Input Volume Range (S24) | 1–15 mL |
| Input Volume Range (H24) | 1–20 mL |
| Elution Volume Range | 20–200 µL |
| Pipetting Range | 20–1000 µL |
| Pipetting Accuracy | ±8% at 20 µL, ±2% at 100 µL, ±1% at 500/1000 µL |
| Pipetting Precision (CV) | ≤5% across all volumes |
| Temperature Control | 37–120 °C |
| Heating Rate | ≤5 min (40–100 °C, ambient 25 °C) |
| Elution Well Capacity | 20–200 µL |
| Reagent Compatibility | Pre-filled 2/8/15 mL strips (S24), 20 mL strips (H24) |
| Software Platform | Android-based 10-inch touchscreen UI with role-based access control |
| Data Interface | USB, LAN, optional barcode scanner integration |
| Contamination Control | Dual UV lamps, HEPA filtration + active exhaust fan, disposable tip architecture |
| Optional Vision Module | Auto-verification of consumable placement and format |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Dimensions (W×D×H) | 740 × 586 × 640 mm |
| Weight | 70 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | K30 Economical Dry Block Heater |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Accuracy | ±0.5°C |
| Heating Time (20°C to 100°C) | ≤15 min |
| Dimensions (W×D×H) | 225 mm × 160 mm × 197 mm |
| Net Weight | 3 kg |
| Power Supply | AC 220 V / 120 V, 50 / 60 Hz |
| Rated Power | 100 W |
| Certifications | CE |
| Timer Range | 1 min – 99 h 59 min |
| Safety Features | Over-temperature protection, auto-shutdown, audible alarm at end of cycle |
| Cooling Method | Integrated fan-assisted cooling |
| Block Type | Interchangeable circular aluminum block |
| Display | Dual LED display showing real-time temperature and countdown timer |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Ecos-Gene Automated Nucleic Acid Detection and Analysis System |
| Sample Throughput | 1/2/4 samples per unit (scalable to 16) |
| Fluorescence Channels | 4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm) |
| Thermal Block Temperature Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C |
| PCR Ramp Rates | ≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling) |
| Extraction CV | ≤5% |
| Sample Input Volume | Up to 3 mL (working volume ~2.5 mL) |
| Software Platform | Windows-based, LIS- and cloud-database–compatible |
| Compliance | Designed for CLIA-waived and IVD-use environments |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MK-10 |
| Temperature Range | Room Temperature +5°C to 100°C |
| Temperature Stability @100°C | ±0.5°C |
| Display Resolution | ±0.1°C |
| Heating Time (25°C to 100°C) | ≤12 min |
| Dimensions (W×D×H) | 300×220×180 mm |
| Net Weight | 2.5 kg |
| Power Supply | AC 220 V / 120 V, 50 / 60 Hz |
| Rated Power | 200 W |
| Certifications | CE |
| Programmable Steps | Up to 5 temperature/time segments |
| Safety Features | Over-temperature protection, self-diagnostic alarm, automatic error detection |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | SealBio-1 Automated Microplate Heat Sealer |
| Temperature Range | Ambient to 200 °C (±1 °C accuracy) |
| Temperature Adjustment | 1 °C increments |
| Preheat Time | 5 min |
| Cycle Time | <20 s per plate |
| Sealing Time Adjustment | 0.5–9.9 s (0.1 s resolution) |
| Compatible Plate Heights | 3–62 mm |
| Plate Standards | ANSI/SBS-compliant (12-, 24-, 48-, 96-, and 384-well formats) |
| Roll Film Width | 78 mm |
| Film Types | Piercable film, aluminum foil, high-strength thermal sealing film |
| Loading | Automatic pre-load roll mechanism |
| Integrated Air Source | Yes (no external compressor required) |
| Interface | 7″ capacitive touchscreen (1024×600), USB-B port, Ethernet port |
| Power | AC 100–240 V, 50/60 Hz |
| Max Power Consumption | 300 W |
| Safety Features | Plate presence detection, film presence detection, standby mode (low-power idle) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MPC-P25 |
| Instrument Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge (≤2,200 rpm) |
| Rotor Configuration | Horizontal Swinging-Bucket Rotor |
| Max Capacity | 2 × microplates (96-well or 384-well PCR/ELISA plates), 24 × 0.2 mL PCR strips, or 192 × 0.2 mL PCR tubes |
| Max Speed | 2,200 rpm |
| Max RCF | 480 × g |
| Timer Range | 0–10 min |
| Dimensions (W×D×H) | 290 × 360 × 140 mm |
| Weight | 3.6 kg |
| Power Supply | AC 120 V / 220 V, 50 / 60 Hz |
| Safety Features | Automatic braking (brake time ≈ 30 s), transparent lid with interlock, soft-start/soft-stop control |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Mini-7K |
| Instrument Type | Palm-Sized Centrifuge |
| Maximum Speed | 7,000 rpm |
| Maximum RCF | 2,300 × g |
| Capacity | 6 × 1.5 mL / 2.0 mL tubes or 2 × 8 × 0.2 mL PCR strips |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Motor Type | Brushless DC Motor |
| Housing Material | Impact-Resistant Composite |
| Safety Features | Lid-Actuated Auto-Stop & Auto-Start, No-Coast Braking |
| Noise Level | <45 dB(A) |
| Dimensions (W × D × H) | 165 × 155 × 115 mm |
| Weight | 1.2 kg |
| Power Consumption | 30 W |
| Brand | Allsheng |
|---|---|
| Model | Au-Shaker 3020TL/2030TL |
| Heating Range | RT +5°C to 105°C |
| Temperature Uniformity | ±0.5°C |
| Temperature Accuracy | ±0.5°C |
| Setpoint Resolution | 0.1°C |
| Max Speed | 3000 rpm (3020TL) / 2000 rpm (2030TL) |
| Orbit Diameter | 3 mm (3020TL) / 2 mm (2030TL) |
| Acceleration Time | 1–10 sec |
| Zero-Positioning Accuracy | ±0.1 mm |
| Clamping Precision | ±0.1 mm |
| Power Supply | 24 V DC, 120 W |
| Communication Interface | DB9 connector with CAN protocol |
| Dimensions (W×D×H) | 142 × 105 × 94 mm |
| Compatible Plate Formats | 96-well, 384-well, 1536-well microplates, 0.5–2.5 mL deep-well plates, PCR plates |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure Mini |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–16 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | ~15 minutes |
| Principle | Magnetic Rod-Based Bead Separation with Vertical Mixing |
| Inter-Well CV | ≤3% |
| Magnetic Bead Recovery Rate | >95% |
| Temperature Control Range | Ambient +5°C to 120°C (Lysis & Elution) |
| Mixing Modes | Programmable Vortex, Aspiration/Dispense, Vertical Oscillation |
| Display | 4.3-inch Touchscreen + 3 Physical Shortcut Keys + Optional External Mouse |
| Onboard Program Storage | 100 protocols |
| Connectivity | USB, Ethernet, Wi-Fi |
| Dimensions (W×D×H) | 20 × 26 × 30 cm |
| Weight | 7 kg |
| Power Input | DC 24 V / 5 A (Battery-Compatible) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Nano-300 |
| Instrument Architecture | Single-beam |
| Detector | 2048-element linear CCD array |
| Wavelength Range | 200–800 nm |
| Wavelength Automation | Motorized scanning |
| Spectral Bandwidth | 1.5 nm (100 µm slit) |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.5 nm |
| Stray Light | <0.05 % at 400 nm |
| OD600 Mode | LED source at 600 ± 8 nm, Absorbance Range: 0–4 A |
| Sample Volume | 0.5–2.0 µL |
| Optical Path Lengths | 0.2 mm (high-concentration), 1.0 mm (standard) |
| Absorbance Accuracy | ±1 % (at 7.332 A, 260 nm) |
| Absorbance Precision | ±0.003 A |
| Absorbance Range (10-mm equivalent) | 0.04–90 A |
| dsDNA Detection Range | 2–4500 ng/µL |
| Measurement Time | <5 s |
| Light Source | Pulsed xenon lamp (OD600 mode: high-stability LED) |
| Data Interface | USB 2.0 |
| Operating System | Custom Android OS (v8.1), 7-inch capacitive touchscreen |
| Power Supply | DC 24 V, 2 A |
| Max Power Consumption | 25 W |
| Standby Power | 5 W |
| Dimensions (W×D×H) | 210 × 268 × 181 mm |
| Weight | 2.8 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
Show next