Empowering Scientific Discovery

Hangzhou Allsheng Instruments Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAPW-200
Plate Format96-well
Residual Volume≤1 µL per well
Wash Head Options8-channel or 12-channel
Wash Volume Range50–2000 µL (50 µL increments)
Wash Cycles1–99
Wash ModesSingle-point, dual-point, multi-point
Soak & Shake DurationUp to 99 min 00 sec
Number of Wash Solutions3 independent channels
Fluid ContainersThree 2.5 L wash bottles + one 2.5 L waste bottle
Dispense Accuracy≤2% @ 300 µL
Dispense Precision (CV)≤1.5% @ 300 µL
Display4.3-inch color LCD
Onboard Memory100 user-programmable protocols
ConnectivityUSB port for protocol transfer and firmware updates
Power SupplyAC 110/240 V, 50/60 Hz
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelHM-3000A
Maximum Operating Temperature825 °C ± 50 °C
Heating Power170 W
Chamber Dimensions (W×D×H)98 mm × 185 mm × 190 mm
Max. Sample DiameterΦ14 mm
Heating Zone Length150 mm
Net Weight1.3 kg
Input VoltageAC 220 V / AC 120 V, 50/60 Hz, 1 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelGene-8C
Sample Capacity8 × 0.2 mL wells (compatible with 8-tube strips)
Reaction Volume20–100 µL (recommended: 25–30 µL)
Excitation Wavelength F1470/30 nm
Emission Wavelength F1535/20 nm
Light SourceHigh-stability LED
Detection MethodReal-time fluorescence monitoring
Temperature RangeAmbient to 99 °C
Max Heating/Cooling Rate2 °C/s
Temperature Uniformity±0.15 °C
Temperature Accuracy±0.1 °C
Thermal LidIntegrated
Display7-inch capacitive touchscreen
Power Supply100–240 VAC, 50–60 Hz
Dimensions (W×D×H)145 × 305 × 100 mm
Weight (without battery)2.3 kg
Compatible DyesFAM/SYBR Green I, HEX/VIC/JOE
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAuto-Pure 96
Instrument TypeMagnetic Bead-Based Extraction
Automation LevelDedicated Fully Automatic
Sample Throughput per Run1–96 (also supports 1–24 configuration)
Sample Volume Range50–1000 µL and 50–10000 µL
Processing Time per Batch30–60 minutes
Heating Capability2 of 8 plate positions with precision temperature control (RT to 120 °C)
Display7-inch color touchscreen interface
Onboard Data StorageInternal SD card
ConnectivityUSB, Ethernet, optional Wi-Fi
UV SterilizationIntegrated
Cross-Contamination ControlAnti-drip baffle, disposable consumables, automated magnetic rod sleeve loading/unloading, barcode recognition
ReproducibilityCV < 5% across wells
Sensitivity>95% positive detection rate for samples containing ≥100 copies
Power Input≤300 W
Dimensions (W×D×H)560 × 620 × 500 mm
Weight54 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAMR-100T
Detection PrincipleFilter-based photometric absorbance
Wavelength Range340–750 nm
Absorbance Range0.000–4.000 Abs
Resolution0.001 Abs
Linearity (R²)≥0.995 (0–3.0 Abs)
Wavelength Accuracy≤±2 nm
Absorbance Precision (CV)≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs)
Absorbance Stability≤0.005 Abs (0–3 Abs)
Absorbance Accuracy±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs)
Measurement Speed6 s/96-well (single wavelength, fast mode)
Filter Capacity8-position wheel (standard 4 filters: 405, 450, 492, 630 nm)
Incubation FunctionYes, 25°C to 50°C (RT + 4°C min)
Display7-inch capacitive touchscreen
Data StorageInternal memory for 1000 protocols & results + USB export
Interfaces3× USB (host/device), supports printer, PC, and flash drive
PowerAC 100–240 V, 50–60 Hz, 2 A
Dimensions (W×D×H)295 × 440 × 225 mm
Weight10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelEsan-Gene 696 / Esan-Gene 696A
Sample Format696 — 0.2 mL tubes & 96-well plates
Reaction Volume10–100 µL
Optical Channels6 (F1: FAM/SYBR Green I
F2HEX/JOE/VIC
F3ROX/Texas Red
F4Cy5/Quasar-670
F5Cy5.5
F6user-definable, default FRET)
Dynamic Range10⁰–10¹⁰ copies/µL
LOD1 copy
Ct ReproducibilityCV ≤ 1%
Temperature Range4–99.9 °C
Heating Rate3.5 °C/s (avg)
Cooling Rate2.5 °C/s (avg)
Block Uniformity±0.2 °C @ 95 °C
Temperature Accuracy±0.15 °C
Temperature Precision0.1 °C
Melting Resolution0.1 °C
Gradient Range1–40 °C across 6 zones
Heat Lid Temp30–110 °C
Display10.1″ LVDS capacitive touchscreen
InterfacesUSB-A ×3, LAN ×1
Data ExportExcel, PDF
ComplianceDesigned for GLP-compliant workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelEsan-Gene 164 Real-Time Fluorescent Quantitative PCR System
QuotationAvailable Upon Request
Throughput16-well (0.2 mL tubes or 8-tube strips)
Sample Volume Range10–100 µL
Dynamic Range1–10¹⁰ copies
Excitation SourceHigh-Stability LED
Detection Channels4 (F1: 515–535 nm
F2535–555 nm
F3600–620 nm
F4665–695 nm)
Fluorescence Detection Range400–770 nm
Detector TypePhotodiode (PD)
Block Temperature Range4–99 °C
Temperature Accuracy±0.15 °C
Temperature Uniformity±0.2 °C @ 95 °C
Max Heating Rate4.0 °C/s
Max Cooling Rate3.0 °C/s
Melting Curve Resolution0.1 °C
Heat Lid Temperature Range30–110 °C (default: block +10 °C)
Heat Lid Accuracy±2 °C
Power Supply220 V AC, 50 Hz
Max Power Consumption200 W
Dimensions (W×D×H)200 × 207 × 148 mm
Weight<3.5 kg
Operating SystemEmbedded Windows-based UI
Display7-inch capacitive touchscreen
ConnectivityUSB 2.0, Ethernet, optional direct thermal printer interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelTD2-24
QuotationUpon Request
Speed Range500–1500 rpm
RCF Range33–294 × g
Capacity24 columns (6- or 8-column immunohematology cards)
Timer Range1–20 min
Noise Level≤55 dB(A)
Power SupplyAC 100–240 V, 50/60 Hz, 3 A
Power Consumption85 W
Dimensions (L×W×H)530 × 410 × 180 mm
Weight11.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAuto-Pure 48
Instrument TypeMagnetic Bead-Based Extraction
Automation LevelDedicated Fully Automatic
Sample Throughput per Run1–48
Sample Volume Range200–3000 µL
Processing Time per Batch15 min
Heating Positions2 of 8 plate stations
Lysis & Elution Temperature RangeAmbient to 120 °C
Inter-Well CV<5%
Detection Sensitivity>95% positive detection rate for 100-copy samples
Display7-inch color touchscreen
Internal StorageSD card
Power Input≤300 W
Dimensions (W×D×H)560 × 620 × 500 mm
Weight54 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAu-Shaker 5012L/3020L/2030L
Rotation Speed Range200–5000 rpm / 200–3000 rpm / 200–2000 rpm
Orbital Diameter1.2 mm / 2.0 mm / 3.0 mm
Timing Range99 h 59 min or 99 min 59 s
Speed Accuracy±7.5 rpm
Acceleration Time1–10 s
Zero-Positioning Accuracy±0.1 mm
Auto-Clamping Positioning Accuracy±0.1 mm
Power Input24 V DC, 48 W
Communication InterfaceDB9 connector, CAN bus protocol
Dimensions (W×D×H)142 × 105 × 94 mm
Weight1.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFeyond-MF200 / Feyond-MF280
Absorbance Range190–1000 nm (1 nm step)
Absorbance Accuracy±(1.0% + 0.003 OD) @ 0.0–2.0 OD
Absorbance Precision (CV)<1.0% (standard mode), <0.5% (high-precision mode)
Wavelength Accuracy±2 nm
Wavelength Repeatability (SD)≤0.2 nm
Spectral Bandwidth (FWHM)≤2.5 nm
Optical Density Resolution0.0001 OD
Linear Range (R²)≥0.999 @ 0.0–3.0 OD
Stray Light≤0.1% @ 220 nm
Read Time (96-well plate)<15 s (A1→H1, fast mode)
Fluorescence DetectionTop-read mode, Xenon lamp excitation, PMT detection
Standard Filter Sets470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions)
Fluorescence LOD≤2 pM (96-well black plate, optimized conditions)
Dynamic Range≥6 decades
Plate Compatibility6–384-well standard and micro-volume plates
Incubation Temperature RangeRT+4°C to 45°C
Temp. Uniformity≤1.0°C @ 37°C
Temp. Accuracy±0.5°C @ 37°C
Agitation ModesLinear, orbital, dual-orbital
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelLeap-Pure S24/H24
PrincipleMagnetic Bead-Based Extraction with Pipetting & Magnetic Rod Transfer
Sample Throughput1–24 samples per run
Input Volume Range (S24)1–15 mL
Input Volume Range (H24)1–20 mL
Elution Volume Range20–200 µL
Pipetting Range20–1000 µL
Pipetting Accuracy±8% at 20 µL, ±2% at 100 µL, ±1% at 500/1000 µL
Pipetting Precision (CV)≤5% across all volumes
Temperature Control37–120 °C
Heating Rate≤5 min (40–100 °C, ambient 25 °C)
Elution Well Capacity20–200 µL
Reagent CompatibilityPre-filled 2/8/15 mL strips (S24), 20 mL strips (H24)
Software PlatformAndroid-based 10-inch touchscreen UI with role-based access control
Data InterfaceUSB, LAN, optional barcode scanner integration
Contamination ControlDual UV lamps, HEPA filtration + active exhaust fan, disposable tip architecture
Optional Vision ModuleAuto-verification of consumable placement and format
Power SupplyAC 220 V, 50 Hz, 450 W
Dimensions (W×D×H)740 × 586 × 640 mm
Weight70 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelK30 Economical Dry Block Heater
Temperature RangeAmbient +5°C to 100°C
Temperature Accuracy±0.5°C
Heating Time (20°C to 100°C)≤15 min
Dimensions (W×D×H)225 mm × 160 mm × 197 mm
Net Weight3 kg
Power SupplyAC 220 V / 120 V, 50 / 60 Hz
Rated Power100 W
CertificationsCE
Timer Range1 min – 99 h 59 min
Safety FeaturesOver-temperature protection, auto-shutdown, audible alarm at end of cycle
Cooling MethodIntegrated fan-assisted cooling
Block TypeInterchangeable circular aluminum block
DisplayDual LED display showing real-time temperature and countdown timer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelEcos-Gene Automated Nucleic Acid Detection and Analysis System
Sample Throughput1/2/4 samples per unit (scalable to 16)
Fluorescence Channels4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm)
Thermal Block Temperature RangeAmbient to 120 °C
Temperature Accuracy±0.2 °C
PCR Ramp Rates≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling)
Extraction CV≤5%
Sample Input VolumeUp to 3 mL (working volume ~2.5 mL)
Software PlatformWindows-based, LIS- and cloud-database–compatible
ComplianceDesigned for CLIA-waived and IVD-use environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelMK-10
Temperature RangeRoom Temperature +5°C to 100°C
Temperature Stability @100°C±0.5°C
Display Resolution±0.1°C
Heating Time (25°C to 100°C)≤12 min
Dimensions (W×D×H)300×220×180 mm
Net Weight2.5 kg
Power SupplyAC 220 V / 120 V, 50 / 60 Hz
Rated Power200 W
CertificationsCE
Programmable StepsUp to 5 temperature/time segments
Safety FeaturesOver-temperature protection, self-diagnostic alarm, automatic error detection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
ModelAMR-Mini T
Detection PrincipleAbsorbance (Optical Density)
Wavelength Range340–750 nm
Standard Filters450/630 nm & 405/492 nm
Optional Filters340–750 nm (28 discrete wavelengths available)
Light SourceDual high-stability LED
Detector9-photodiode array
Measurement ModesEndpoint, Kinetic, Dual-Wavelength
Absorbance Range0–4.0 Abs
Resolution0.001 Abs
Accuracy≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs
LinearityR² ≥ 0.995 (0.0–3.0 Abs)
RepeatabilityCV ≤ 0.5% (0–3.0 Abs)
Stability≤0.005 Abs (0.0–2.0 Abs)
Read Time<15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well)
Incubation Temp RangeRT+4°C to 45°C
Dimensions (W×D×H)135 × 245 × 91 mm
Weight2.5 kg
InterfaceUSB-A, USB-C, Bluetooth 5.0
Power12 V DC, 3 A
SoftwareCross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese)
ComplianceDesigned per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelSealBio-1 Automated Microplate Heat Sealer
Temperature RangeAmbient to 200 °C (±1 °C accuracy)
Temperature Adjustment1 °C increments
Preheat Time5 min
Cycle Time<20 s per plate
Sealing Time Adjustment0.5–9.9 s (0.1 s resolution)
Compatible Plate Heights3–62 mm
Plate StandardsANSI/SBS-compliant (12-, 24-, 48-, 96-, and 384-well formats)
Roll Film Width78 mm
Film TypesPiercable film, aluminum foil, high-strength thermal sealing film
LoadingAutomatic pre-load roll mechanism
Integrated Air SourceYes (no external compressor required)
Interface7″ capacitive touchscreen (1024×600), USB-B port, Ethernet port
PowerAC 100–240 V, 50/60 Hz
Max Power Consumption300 W
Safety FeaturesPlate presence detection, film presence detection, standby mode (low-power idle)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelMPC-P25
Instrument TypeBenchtop Centrifuge
CategoryLow-Speed Centrifuge (≤2,200 rpm)
Rotor ConfigurationHorizontal Swinging-Bucket Rotor
Max Capacity2 × microplates (96-well or 384-well PCR/ELISA plates), 24 × 0.2 mL PCR strips, or 192 × 0.2 mL PCR tubes
Max Speed2,200 rpm
Max RCF480 × g
Timer Range0–10 min
Dimensions (W×D×H)290 × 360 × 140 mm
Weight3.6 kg
Power SupplyAC 120 V / 220 V, 50 / 60 Hz
Safety FeaturesAutomatic braking (brake time ≈ 30 s), transparent lid with interlock, soft-start/soft-stop control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelMini-7K
Instrument TypePalm-Sized Centrifuge
Maximum Speed7,000 rpm
Maximum RCF2,300 × g
Capacity6 × 1.5 mL / 2.0 mL tubes or 2 × 8 × 0.2 mL PCR strips
Power SupplyAC 100–240 V, 50/60 Hz
Motor TypeBrushless DC Motor
Housing MaterialImpact-Resistant Composite
Safety FeaturesLid-Actuated Auto-Stop & Auto-Start, No-Coast Braking
Noise Level<45 dB(A)
Dimensions (W × D × H)165 × 155 × 115 mm
Weight1.2 kg
Power Consumption30 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
ModelAu-Shaker 3020TL/2030TL
Heating RangeRT +5°C to 105°C
Temperature Uniformity±0.5°C
Temperature Accuracy±0.5°C
Setpoint Resolution0.1°C
Max Speed3000 rpm (3020TL) / 2000 rpm (2030TL)
Orbit Diameter3 mm (3020TL) / 2 mm (2030TL)
Acceleration Time1–10 sec
Zero-Positioning Accuracy±0.1 mm
Clamping Precision±0.1 mm
Power Supply24 V DC, 120 W
Communication InterfaceDB9 connector with CAN protocol
Dimensions (W×D×H)142 × 105 × 94 mm
Compatible Plate Formats96-well, 384-well, 1536-well microplates, 0.5–2.5 mL deep-well plates, PCR plates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAuto-Pure Mini
Instrument TypeMagnetic Bead-Based Extraction
Automation LevelDedicated Fully Automatic
Sample Throughput per Run1–16 samples
Sample Volume Range20–1000 µL
Processing Time per Batch~15 minutes
PrincipleMagnetic Rod-Based Bead Separation with Vertical Mixing
Inter-Well CV≤3%
Magnetic Bead Recovery Rate>95%
Temperature Control RangeAmbient +5°C to 120°C (Lysis & Elution)
Mixing ModesProgrammable Vortex, Aspiration/Dispense, Vertical Oscillation
Display4.3-inch Touchscreen + 3 Physical Shortcut Keys + Optional External Mouse
Onboard Program Storage100 protocols
ConnectivityUSB, Ethernet, Wi-Fi
Dimensions (W×D×H)20 × 26 × 30 cm
Weight7 kg
Power InputDC 24 V / 5 A (Battery-Compatible)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFlexA-200HT
Detection PrincipleAbsorbance (UV-Vis)
Wavelength Range200–1000 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability±0.2 nm
Optical SystemGrating-based monochromator, dual-beam with reference channel
Spectral Resolution1 nm step
Absorbance Range0–4.0 OD
Linearity (at 450 nm)R ≥ 0.999 [0.0–3.0 Abs]
Absorbance Accuracy (at 450 nm)±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs]
Absorbance Precision (CV)<0.5% (precise mode), <1.0% (fast mode)
96-well Plate Read Time~8 s (fast), <28 s (precise, endpoint)
Temperature Control RangeAmbient +4 °C to 45 °C
Temp. Uniformity & Accuracy±0.5 °C at 37 °C
IncubationIntegrated plate and cuvette chamber
VibrationLinear, 3-speed adjustable
DetectorDual silicon photodiodes (sample + reference)
Bandwidth<2.5 nm
Light SourceXenon flash lamp (>1×10⁹ flashes lifetime)
Display10-inch capacitive touchscreen (Android OS)
Onboard Storage16 GB (≥20,000 assay records)
Connectivity2× USB-A, 1× USB-B, 1× Ethernet
Dimensions (W×D×H)300 × 500 × 260 mm
Weight15.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelNano-300
Instrument ArchitectureSingle-beam
Detector2048-element linear CCD array
Wavelength Range200–800 nm
Wavelength AutomationMotorized scanning
Spectral Bandwidth1.5 nm (100 µm slit)
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.5 nm
Stray Light<0.05 % at 400 nm
OD600 ModeLED source at 600 ± 8 nm, Absorbance Range: 0–4 A
Sample Volume0.5–2.0 µL
Optical Path Lengths0.2 mm (high-concentration), 1.0 mm (standard)
Absorbance Accuracy±1 % (at 7.332 A, 260 nm)
Absorbance Precision±0.003 A
Absorbance Range (10-mm equivalent)0.04–90 A
dsDNA Detection Range2–4500 ng/µL
Measurement Time<5 s
Light SourcePulsed xenon lamp (OD600 mode: high-stability LED)
Data InterfaceUSB 2.0
Operating SystemCustom Android OS (v8.1), 7-inch capacitive touchscreen
Power SupplyDC 24 V, 2 A
Max Power Consumption25 W
Standby Power5 W
Dimensions (W×D×H)210 × 268 × 181 mm
Weight2.8 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFeyond-A500
Detection ModesAbsorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP)
Wavelength Range (Abs)200–1000 nm, 1 nm step
Absorbance Range0–4 OD
Absorbance Accuracy±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD)
Absorbance PrecisionCV < 1.0% or SD < 0.003 OD (96-well, precise mode)
Read Time (96-well)<15 s (fast mode)
Luminescence Sensitivity≤15 amol/plate (ATP assay)
Dynamic Range (Luminescence)6 decades
Fluorescence Sensitivity≤1 pM (FITC in 96-well)
TRF Sensitivity≤0.05 pM (Eu-labeled conjugate)
FP Sensitivity≤5 mP (standard assay)
Excitation/Emission Filter Capacity3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable
IncubationPID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C
Display10-inch motorized rotatable touchscreen (standalone operation)
SoftwareOnboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I)
Show next