Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAPW-200
Plate Format96-well
Residual Volume≤1 µL per well
Wash Head Options8-channel or 12-channel
Wash Volume Range50–2000 µL (50 µL increments)
Wash Cycles1–99
Wash ModesSingle-point, dual-point, multi-point
Soak & Shake DurationUp to 99 min 00 sec
Number of Wash Solutions3 independent channels
Fluid ContainersThree 2.5 L wash bottles + one 2.5 L waste bottle
Dispense Accuracy≤2% @ 300 µL
Dispense Precision (CV)≤1.5% @ 300 µL
Display4.3-inch color LCD
Onboard Memory100 user-programmable protocols
ConnectivityUSB port for protocol transfer and firmware updates
Power SupplyAC 110/240 V, 50/60 Hz
Weight12 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAMR-100T
Detection PrincipleFilter-based photometric absorbance
Wavelength Range340–750 nm
Absorbance Range0.000–4.000 Abs
Resolution0.001 Abs
Linearity (R²)≥0.995 (0–3.0 Abs)
Wavelength Accuracy≤±2 nm
Absorbance Precision (CV)≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs)
Absorbance Stability≤0.005 Abs (0–3 Abs)
Absorbance Accuracy±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs)
Measurement Speed6 s/96-well (single wavelength, fast mode)
Filter Capacity8-position wheel (standard 4 filters: 405, 450, 492, 630 nm)
Incubation FunctionYes, 25°C to 50°C (RT + 4°C min)
Display7-inch capacitive touchscreen
Data StorageInternal memory for 1000 protocols & results + USB export
Interfaces3× USB (host/device), supports printer, PC, and flash drive
PowerAC 100–240 V, 50–60 Hz, 2 A
Dimensions (W×D×H)295 × 440 × 225 mm
Weight10 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFeyond-MF200 / Feyond-MF280
Absorbance Range190–1000 nm (1 nm step)
Absorbance Accuracy±(1.0% + 0.003 OD) @ 0.0–2.0 OD
Absorbance Precision (CV)<1.0% (standard mode), <0.5% (high-precision mode)
Wavelength Accuracy±2 nm
Wavelength Repeatability (SD)≤0.2 nm
Spectral Bandwidth (FWHM)≤2.5 nm
Optical Density Resolution0.0001 OD
Linear Range (R²)≥0.999 @ 0.0–3.0 OD
Stray Light≤0.1% @ 220 nm
Read Time (96-well plate)<15 s (A1→H1, fast mode)
Fluorescence DetectionTop-read mode, Xenon lamp excitation, PMT detection
Standard Filter Sets470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions)
Fluorescence LOD≤2 pM (96-well black plate, optimized conditions)
Dynamic Range≥6 decades
Plate Compatibility6–384-well standard and micro-volume plates
Incubation Temperature RangeRT+4°C to 45°C
Temp. Uniformity≤1.0°C @ 37°C
Temp. Accuracy±0.5°C @ 37°C
Agitation ModesLinear, orbital, dual-orbital
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
ModelAMR-Mini T
Detection PrincipleAbsorbance (Optical Density)
Wavelength Range340–750 nm
Standard Filters450/630 nm & 405/492 nm
Optional Filters340–750 nm (28 discrete wavelengths available)
Light SourceDual high-stability LED
Detector9-photodiode array
Measurement ModesEndpoint, Kinetic, Dual-Wavelength
Absorbance Range0–4.0 Abs
Resolution0.001 Abs
Accuracy≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs
LinearityR² ≥ 0.995 (0.0–3.0 Abs)
RepeatabilityCV ≤ 0.5% (0–3.0 Abs)
Stability≤0.005 Abs (0.0–2.0 Abs)
Read Time<15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well)
Incubation Temp RangeRT+4°C to 45°C
Dimensions (W×D×H)135 × 245 × 91 mm
Weight2.5 kg
InterfaceUSB-A, USB-C, Bluetooth 5.0
Power12 V DC, 3 A
SoftwareCross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese)
ComplianceDesigned per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFlexA-200HT
Detection PrincipleAbsorbance (UV-Vis)
Wavelength Range200–1000 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability±0.2 nm
Optical SystemGrating-based monochromator, dual-beam with reference channel
Spectral Resolution1 nm step
Absorbance Range0–4.0 OD
Linearity (at 450 nm)R ≥ 0.999 [0.0–3.0 Abs]
Absorbance Accuracy (at 450 nm)±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs]
Absorbance Precision (CV)<0.5% (precise mode), <1.0% (fast mode)
96-well Plate Read Time~8 s (fast), <28 s (precise, endpoint)
Temperature Control RangeAmbient +4 °C to 45 °C
Temp. Uniformity & Accuracy±0.5 °C at 37 °C
IncubationIntegrated plate and cuvette chamber
VibrationLinear, 3-speed adjustable
DetectorDual silicon photodiodes (sample + reference)
Bandwidth<2.5 nm
Light SourceXenon flash lamp (>1×10⁹ flashes lifetime)
Display10-inch capacitive touchscreen (Android OS)
Onboard Storage16 GB (≥20,000 assay records)
Connectivity2× USB-A, 1× USB-B, 1× Ethernet
Dimensions (W×D×H)300 × 500 × 260 mm
Weight15.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFeyond-A500
Detection ModesAbsorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP)
Wavelength Range (Abs)200–1000 nm, 1 nm step
Absorbance Range0–4 OD
Absorbance Accuracy±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD)
Absorbance PrecisionCV < 1.0% or SD < 0.003 OD (96-well, precise mode)
Read Time (96-well)<15 s (fast mode)
Luminescence Sensitivity≤15 amol/plate (ATP assay)
Dynamic Range (Luminescence)6 decades
Fluorescence Sensitivity≤1 pM (FITC in 96-well)
TRF Sensitivity≤0.05 pM (Eu-labeled conjugate)
FP Sensitivity≤5 mP (standard assay)
Excitation/Emission Filter Capacity3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable
IncubationPID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C
Display10-inch motorized rotatable touchscreen (standalone operation)
SoftwareOnboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFeyond-L100
Detection PrincipleChemiluminescence (PMT-based)
Detection Limit5 amol ATP per well
Linear Dynamic Range6 logs
Well-to-Well Crosstalk≤0.005%
Wavelength Range200–850 nm
Plate Formats6–384-well microplates
Automation LevelFully Automated (integrated dispensers)
ComplianceGLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelAMR-Mini
Light SourceDual high-stability LED (340–750 nm)
Detection PrincipleAbsorbance (Optical Density)
Standard Filters450/630 nm & 405/492 nm
Custom Filter Options340–750 nm (28 wavelengths available)
Detector9-photodiode array
Measurement Range0–4.0 Abs
Resolution0.001 Abs
Wavelength Accuracy≤ ±2 nm
LinearityR² ≥ 0.995 (0.0–3.0 Abs)
Photometric Accuracy≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs)
Precision (CV)≤ 0.5% [0–3.0 Abs)
Stability≤ 0.005 Abs [0.0–2.0 Abs)
Read Time<15 s (single wavelength), <28 s (dual wavelength) for 96-well plate
Dimensions (W×D×H)135 × 225 × 89 mm
Weight2.0 kg
PowerUSB-powered (12 V, 3 A)
Interface1 × USB-C, 1 × USB-A
ConnectivityBluetooth 5.0, USB cable
SoftwareCross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese)
Optional ModuleAMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAllsheng
OriginZhejiang, China
ModelFlexA-200
Detection PrincipleAbsorbance (UV-Vis)
Wavelength Range200–1000 nm
Wavelength Accuracy±2 nm
Wavelength Repeatability±0.2 nm
Optical SystemGrating-based monochromator with 1 nm step resolution
Read Range0–4.0 OD
Bandwidth<2.5 nm
Photometric Accuracy @450 nm±(1.0% + 0.003 Abs) for 0–2.0 Abs
Photometric Precision @450 nmCV < 0.5% (precise mode), CV < 1.0% (fast mode)
96-well Plate Read Time~8 s (fast), <28 s (precise, endpoint)
Temperature Control RangeAmbient +4 °C to 45 °C
Temp. Uniformity & Accuracy±0.5 °C at 37 °C
DetectorDual silicon photodiodes (sample + reference beam)
Display10-inch capacitive touchscreen (Android OS)
Onboard Storage16 GB (≥20,000 assay files)
Connectivity1× USB-B, 2× USB-A, 1× Ethernet
Dimensions (W×D×H)300 × 500 × 260 mm
Net Weight15.5 kg