- All
- Favorite
- Popular
- Most rated
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-L100 |
| Detection Principle | Chemiluminescence (PMT-based) |
| Detection Limit | 5 amol ATP per well |
| Linear Dynamic Range | 6 logs |
| Well-to-Well Crosstalk | ≤0.005% |
| Wavelength Range | 200–850 nm |
| Plate Formats | 6–384-well microplates |
| Automation Level | Fully Automated (integrated dispensers) |
| Compliance | GLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-Mini |
| Light Source | Dual high-stability LED (340–750 nm) |
| Detection Principle | Absorbance (Optical Density) |
| Standard Filters | 450/630 nm & 405/492 nm |
| Custom Filter Options | 340–750 nm (28 wavelengths available) |
| Detector | 9-photodiode array |
| Measurement Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ≤ ±2 nm |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Photometric Accuracy | ≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs) |
| Precision (CV) | ≤ 0.5% [0–3.0 Abs) |
| Stability | ≤ 0.005 Abs [0.0–2.0 Abs) |
| Read Time | <15 s (single wavelength), <28 s (dual wavelength) for 96-well plate |
| Dimensions (W×D×H) | 135 × 225 × 89 mm |
| Weight | 2.0 kg |
| Power | USB-powered (12 V, 3 A) |
| Interface | 1 × USB-C, 1 × USB-A |
| Connectivity | Bluetooth 5.0, USB cable |
| Software | Cross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese) |
| Optional Module | AMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200 |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator with 1 nm step resolution |
| Read Range | 0–4.0 OD |
| Bandwidth | <2.5 nm |
| Photometric Accuracy @450 nm | ±(1.0% + 0.003 Abs) for 0–2.0 Abs |
| Photometric Precision @450 nm | CV < 0.5% (precise mode), CV < 1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Detector | Dual silicon photodiodes (sample + reference beam) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay files) |
| Connectivity | 1× USB-B, 2× USB-A, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Net Weight | 15.5 kg |