- All
- Favorite
- Popular
- Most rated
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | APW-200 |
| Plate Format | 96-well |
| Residual Volume | ≤1 µL per well |
| Wash Head Options | 8-channel or 12-channel |
| Wash Volume Range | 50–2000 µL (50 µL increments) |
| Wash Cycles | 1–99 |
| Wash Modes | Single-point, dual-point, multi-point |
| Soak & Shake Duration | Up to 99 min 00 sec |
| Number of Wash Solutions | 3 independent channels |
| Fluid Containers | Three 2.5 L wash bottles + one 2.5 L waste bottle |
| Dispense Accuracy | ≤2% @ 300 µL |
| Dispense Precision (CV) | ≤1.5% @ 300 µL |
| Display | 4.3-inch color LCD |
| Onboard Memory | 100 user-programmable protocols |
| Connectivity | USB port for protocol transfer and firmware updates |
| Power Supply | AC 110/240 V, 50/60 Hz |
| Weight | 12 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 96 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–96 (also supports 1–24 configuration) |
| Sample Volume Range | 50–1000 µL and 50–10000 µL |
| Processing Time per Batch | 30–60 minutes |
| Heating Capability | 2 of 8 plate positions with precision temperature control (RT to 120 °C) |
| Display | 7-inch color touchscreen interface |
| Onboard Data Storage | Internal SD card |
| Connectivity | USB, Ethernet, optional Wi-Fi |
| UV Sterilization | Integrated |
| Cross-Contamination Control | Anti-drip baffle, disposable consumables, automated magnetic rod sleeve loading/unloading, barcode recognition |
| Reproducibility | CV < 5% across wells |
| Sensitivity | >95% positive detection rate for samples containing ≥100 copies |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-100T |
| Detection Principle | Filter-based photometric absorbance |
| Wavelength Range | 340–750 nm |
| Absorbance Range | 0.000–4.000 Abs |
| Resolution | 0.001 Abs |
| Linearity (R²) | ≥0.995 (0–3.0 Abs) |
| Wavelength Accuracy | ≤±2 nm |
| Absorbance Precision (CV) | ≤0.3% (0–3 Abs), ≤1.0% (3–4 Abs) |
| Absorbance Stability | ≤0.005 Abs (0–3 Abs) |
| Absorbance Accuracy | ±0.005 Abs (0–2 Abs), ±0.01 Abs (2–3 Abs), ±1.5% (3–4 Abs) |
| Measurement Speed | 6 s/96-well (single wavelength, fast mode) |
| Filter Capacity | 8-position wheel (standard 4 filters: 405, 450, 492, 630 nm) |
| Incubation Function | Yes, 25°C to 50°C (RT + 4°C min) |
| Display | 7-inch capacitive touchscreen |
| Data Storage | Internal memory for 1000 protocols & results + USB export |
| Interfaces | 3× USB (host/device), supports printer, PC, and flash drive |
| Power | AC 100–240 V, 50–60 Hz, 2 A |
| Dimensions (W×D×H) | 295 × 440 × 225 mm |
| Weight | 10 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Esan-Gene 696 / Esan-Gene 696A |
| Sample Format | 696 — 0.2 mL tubes & 96-well plates |
| Reaction Volume | 10–100 µL |
| Optical Channels | 6 (F1: FAM/SYBR Green I |
| F2 | HEX/JOE/VIC |
| F3 | ROX/Texas Red |
| F4 | Cy5/Quasar-670 |
| F5 | Cy5.5 |
| F6 | user-definable, default FRET) |
| Dynamic Range | 10⁰–10¹⁰ copies/µL |
| LOD | 1 copy |
| Ct Reproducibility | CV ≤ 1% |
| Temperature Range | 4–99.9 °C |
| Heating Rate | 3.5 °C/s (avg) |
| Cooling Rate | 2.5 °C/s (avg) |
| Block Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Temperature Precision | 0.1 °C |
| Melting Resolution | 0.1 °C |
| Gradient Range | 1–40 °C across 6 zones |
| Heat Lid Temp | 30–110 °C |
| Display | 10.1″ LVDS capacitive touchscreen |
| Interfaces | USB-A ×3, LAN ×1 |
| Data Export | Excel, PDF |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 48 |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–48 |
| Sample Volume Range | 200–3000 µL |
| Processing Time per Batch | 15 min |
| Heating Positions | 2 of 8 plate stations |
| Lysis & Elution Temperature Range | Ambient to 120 °C |
| Inter-Well CV | <5% |
| Detection Sensitivity | >95% positive detection rate for 100-copy samples |
| Display | 7-inch color touchscreen |
| Internal Storage | SD card |
| Power Input | ≤300 W |
| Dimensions (W×D×H) | 560 × 620 × 500 mm |
| Weight | 54 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-MF200 / Feyond-MF280 |
| Absorbance Range | 190–1000 nm (1 nm step) |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) @ 0.0–2.0 OD |
| Absorbance Precision (CV) | <1.0% (standard mode), <0.5% (high-precision mode) |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability (SD) | ≤0.2 nm |
| Spectral Bandwidth (FWHM) | ≤2.5 nm |
| Optical Density Resolution | 0.0001 OD |
| Linear Range (R²) | ≥0.999 @ 0.0–3.0 OD |
| Stray Light | ≤0.1% @ 220 nm |
| Read Time (96-well plate) | <15 s (A1→H1, fast mode) |
| Fluorescence Detection | Top-read mode, Xenon lamp excitation, PMT detection |
| Standard Filter Sets | 470/525 nm, 523/564 nm, 624/692 nm (up to 8 filter positions) |
| Fluorescence LOD | ≤2 pM (96-well black plate, optimized conditions) |
| Dynamic Range | ≥6 decades |
| Plate Compatibility | 6–384-well standard and micro-volume plates |
| Incubation Temperature Range | RT+4°C to 45°C |
| Temp. Uniformity | ≤1.0°C @ 37°C |
| Temp. Accuracy | ±0.5°C @ 37°C |
| Agitation Modes | Linear, orbital, dual-orbital |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Pure S24/H24 |
| Principle | Magnetic Bead-Based Extraction with Pipetting & Magnetic Rod Transfer |
| Sample Throughput | 1–24 samples per run |
| Input Volume Range (S24) | 1–15 mL |
| Input Volume Range (H24) | 1–20 mL |
| Elution Volume Range | 20–200 µL |
| Pipetting Range | 20–1000 µL |
| Pipetting Accuracy | ±8% at 20 µL, ±2% at 100 µL, ±1% at 500/1000 µL |
| Pipetting Precision (CV) | ≤5% across all volumes |
| Temperature Control | 37–120 °C |
| Heating Rate | ≤5 min (40–100 °C, ambient 25 °C) |
| Elution Well Capacity | 20–200 µL |
| Reagent Compatibility | Pre-filled 2/8/15 mL strips (S24), 20 mL strips (H24) |
| Software Platform | Android-based 10-inch touchscreen UI with role-based access control |
| Data Interface | USB, LAN, optional barcode scanner integration |
| Contamination Control | Dual UV lamps, HEPA filtration + active exhaust fan, disposable tip architecture |
| Optional Vision Module | Auto-verification of consumable placement and format |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Dimensions (W×D×H) | 740 × 586 × 640 mm |
| Weight | 70 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Ecos-Gene Automated Nucleic Acid Detection and Analysis System |
| Sample Throughput | 1/2/4 samples per unit (scalable to 16) |
| Fluorescence Channels | 4 (470–510 nm, 530–565 nm, 585–620 nm, 630–665 nm) |
| Thermal Block Temperature Range | Ambient to 120 °C |
| Temperature Accuracy | ±0.2 °C |
| PCR Ramp Rates | ≥6 °C/s (avg. heating), ≥8 °C/s (max. heating), ≥4.5 °C/s (avg. cooling), ≥8 °C/s (max. cooling) |
| Extraction CV | ≤5% |
| Sample Input Volume | Up to 3 mL (working volume ~2.5 mL) |
| Software Platform | Windows-based, LIS- and cloud-database–compatible |
| Compliance | Designed for CLIA-waived and IVD-use environments |
| Brand | Allsheng |
|---|---|
| Model | AMR-Mini T |
| Detection Principle | Absorbance (Optical Density) |
| Wavelength Range | 340–750 nm |
| Standard Filters | 450/630 nm & 405/492 nm |
| Optional Filters | 340–750 nm (28 discrete wavelengths available) |
| Light Source | Dual high-stability LED |
| Detector | 9-photodiode array |
| Measurement Modes | Endpoint, Kinetic, Dual-Wavelength |
| Absorbance Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Accuracy | ≤±(0.5% + 0.01 Abs) @ 0.0–2.0 Abs |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Repeatability | CV ≤ 0.5% (0–3.0 Abs) |
| Stability | ≤0.005 Abs (0.0–2.0 Abs) |
| Read Time | <15 s (single-wavelength, 96-well), <28 s (dual-wavelength, 96-well) |
| Incubation Temp Range | RT+4°C to 45°C |
| Dimensions (W×D×H) | 135 × 245 × 91 mm |
| Weight | 2.5 kg |
| Interface | USB-A, USB-C, Bluetooth 5.0 |
| Power | 12 V DC, 3 A |
| Software | Cross-platform PC application (Windows 7/10 64-bit) and mobile app (iOS/Android), bilingual UI (English/Chinese) |
| Compliance | Designed per ISO 15197:2013 and CLSI EP17-A2 guidelines for quantitative absorbance-based immunoassays |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure Mini |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput per Run | 1–16 samples |
| Sample Volume Range | 20–1000 µL |
| Processing Time per Batch | ~15 minutes |
| Principle | Magnetic Rod-Based Bead Separation with Vertical Mixing |
| Inter-Well CV | ≤3% |
| Magnetic Bead Recovery Rate | >95% |
| Temperature Control Range | Ambient +5°C to 120°C (Lysis & Elution) |
| Mixing Modes | Programmable Vortex, Aspiration/Dispense, Vertical Oscillation |
| Display | 4.3-inch Touchscreen + 3 Physical Shortcut Keys + Optional External Mouse |
| Onboard Program Storage | 100 protocols |
| Connectivity | USB, Ethernet, Wi-Fi |
| Dimensions (W×D×H) | 20 × 26 × 30 cm |
| Weight | 7 kg |
| Power Input | DC 24 V / 5 A (Battery-Compatible) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200HT |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator, dual-beam with reference channel |
| Spectral Resolution | 1 nm step |
| Absorbance Range | 0–4.0 OD |
| Linearity (at 450 nm) | R ≥ 0.999 [0.0–3.0 Abs] |
| Absorbance Accuracy (at 450 nm) | ±(1.0% + 0.003 Abs) [0–2.0 Abs], ±2.0% [2.0–2.5 Abs] |
| Absorbance Precision (CV) | <0.5% (precise mode), <1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Incubation | Integrated plate and cuvette chamber |
| Vibration | Linear, 3-speed adjustable |
| Detector | Dual silicon photodiodes (sample + reference) |
| Bandwidth | <2.5 nm |
| Light Source | Xenon flash lamp (>1×10⁹ flashes lifetime) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay records) |
| Connectivity | 2× USB-A, 1× USB-B, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-A500 |
| Detection Modes | Absorbance, Fluorescence (Top-Read), Chemiluminescence, Time-Resolved Fluorescence (TRF), Fluorescence Polarization (FP) |
| Wavelength Range (Abs) | 200–1000 nm, 1 nm step |
| Absorbance Range | 0–4 OD |
| Absorbance Accuracy | ±(1.0% + 0.003 OD) at 450 nm (0.0–2.0 OD) |
| Absorbance Precision | CV < 1.0% or SD < 0.003 OD (96-well, precise mode) |
| Read Time (96-well) | <15 s (fast mode) |
| Luminescence Sensitivity | ≤15 amol/plate (ATP assay) |
| Dynamic Range (Luminescence) | 6 decades |
| Fluorescence Sensitivity | ≤1 pM (FITC in 96-well) |
| TRF Sensitivity | ≤0.05 pM (Eu-labeled conjugate) |
| FP Sensitivity | ≤5 mP (standard assay) |
| Excitation/Emission Filter Capacity | 3 pre-installed dual-filter sets (e.g., EX470/EM525), modular & barcode-readable |
| Incubation | PID-controlled, dual-zone (top/bottom), 25–45 °C ±0.5 °C |
| Display | 10-inch motorized rotatable touchscreen (standalone operation) |
| Software | Onboard analysis suite including endpoint, kinetics, spectral scan, standard curve fitting (4PL/5PL), qualitative/quantitative modules, GLP-compliant audit trail (optional PC software: ReaderLT-I) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-Pure S32 |
| Pricing | Upon Request |
| Principle | Magnetic Bead-Based Separation |
| Sample Throughput | 1–32 samples per run |
| Compatible Plate Format | 96-Deep-Well Plate |
| Processing Volume | 30–1000 µL |
| Inter-Well CV | ≤5% |
| Lysis Temperature Range | Ambient to 120°C |
| Elution Temperature Range | Ambient to 120°C |
| Heating Time (RT to 120°C) | ≤4 min |
| Cooling Time (100°C to 40°C) | ≤10 min (at 25°C ambient) |
| Temperature Accuracy | ±0.5°C |
| Temperature Uniformity | ±1°C at 100°C |
| Mixing Intensity | 10 Adjustable Levels |
| Display | 7-inch Color Touchscreen |
| Onboard Program Storage | Up to 500 Protocols |
| Interface Ports | 2× USB-A, 1× USB-B, 1× Ethernet |
| Wireless Connectivity | Built-in Wi-Fi (4G optional) |
| Barcode Scanning | External Scanner Support with Auto-Protocol/ID Recognition |
| UV Sterilization | Integrated Germicidal UV Lamp |
| Air Filtration | HEPA-Grade Aerosol Filtration System |
| Power Supply | AC 110–240 V, 50/60 Hz, 450 VA |
| Dimensions (W×D×H) | 417 × 410 × 426 mm |
| Weight | 20 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Emos-Gene 600 / Emos-Gene 600A |
| Sample Capacity | 3 × 32-well (0.2 mL for 600 |
| Detection Channels | 6 independent optical channels (C1–C6) |
| Excitation Source | High-power white LED array |
| Detection Sensor | High-sensitivity CMOS imaging system with precision filter wheel |
| Temperature Range | 4 °C to 99.9 °C |
| Temperature Uniformity | ±0.2 °C @ 95 °C |
| Temperature Accuracy | ±0.15 °C |
| Ramp Rate | 4 °C/s (both heating and cooling) |
| Thermal Lid | Auto-adjustable pressure, 30–110 °C |
| Gradient Capability | Single-module gradient control |
| Display | 13.3-inch capacitive touchscreen |
| OS | Windows 10 or later |
| Power Input | 100–240 V~, 50 Hz, 1400 VA |
| Dimensions (D×W×H) | 504 × 360 × 410 mm |
| Weight | 35 kg |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-NGS 180S |
| Sample Throughput | 8–24 samples per run (full automation) |
| Pipetting Channels | 24-channel adjustable (1/8/16/24-channel modes) |
| Pipetting Range | 0.5–200 µL |
| Accuracy (A) | ±10% at 0.5 µL, ±2% at 20 µL, ±1% at 100/200 µL |
| Precision (CV) | ≤5% at 0.5 µL, ≤2% at 20 µL, ≤1% at 100/200 µL |
| Minimum Sample Volume for Fluorometric Quantification | 2 µL |
| dsDNA Detection Limit | 0.4 ng |
| Fluorescence Module | 24-well integrated fluorometer, CV ≤1.5% repeatability |
| Thermal Modules | Dual 4–105 °C refrigeration units (±0.5 °C accuracy/uniformity), one heating module (RT–105 °C), one heating-shaking module (RT–105 °C, 200–3000 RPM, 2 mm orbit), one PCR thermal cycler (block: 4–99 °C, lid: 30–120 °C, uniformity ±0.7 °C, accuracy ≤±0.3 °C) |
| Magnetic Bead Purification | 96-well circular magnetic stand (compatible with PCR/deep-well plates) |
| Tip Capacity | Up to 10 tip boxes (6 single-layer + 2 double-layer positions) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Feyond-L100 |
| Detection Principle | Chemiluminescence (PMT-based) |
| Detection Limit | 5 amol ATP per well |
| Linear Dynamic Range | 6 logs |
| Well-to-Well Crosstalk | ≤0.005% |
| Wavelength Range | 200–850 nm |
| Plate Formats | 6–384-well microplates |
| Automation Level | Fully Automated (integrated dispensers) |
| Compliance | GLP-ready architecture, audit-trail capable software (ReaderLT-I), supports 21 CFR Part 11-compliant configurations |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | FCM-2 |
| Pricing | Available Upon Request |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Leap-Count 100 / Leap-Count 100A |
| Measurement Principle | Brightfield optical imaging with AI-powered image segmentation |
| Cell Diameter Range | 3–60 µm |
| Cell Concentration Range | 1×10⁴–1×10⁹ cells/mL |
| Optimal Concentration Range | 1×10⁵–1×10⁷ cells/mL |
| Viability Detection Range | 0–100% |
| Sample Volume per Chamber | 10 µL |
| Analysis Time (Leap-Count 100) | ≤8 s |
| Analysis Time (Leap-Count 100A) | ≤2 s |
| Imaging Sensor | 6 MP CMOS |
| Objective Magnification | 3× |
| Repeatability (CV) | <5% |
| Storage Capacity | 1 TB (Leap-Count 100), External PC only (Leap-Count 100A) |
| Display | 10.1″ LCD, 1920×1200 (Leap-Count 100), None (Leap-Count 100A) |
| Data Export Formats | PDF, XLS, TIFF, PNG, JPG |
| Operating System | Windows 10 or later |
| Interface | USB 3.2 Gen 2 ×2 + Ethernet (Leap-Count 100) |
| Dimensions (W×D×H) | 260×268×246 mm (flat) / 260×268×376 mm (vertical) (Leap-Count 100) |
| Weight | 6.5 kg (Leap-Count 100), 5.0 kg (Leap-Count 100A) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-Pure 10BS |
| Instrument Type | Magnetic Bead-Based Extraction |
| Automation Level | Dedicated Fully Automatic |
| Sample Throughput | 1–10 samples/batch |
| Sample Volume Range | 50–5000 µL |
| Processing Time per Batch | 15–30 min |
| Heating Block Temperature Range | Room Temp +5°C to 105°C |
| Lysis/Elution Temperature Range | Room Temp to 120°C |
| Magnetic Bead Recovery Rate | >95% |
| Inter-Well CV | <5% |
| Detection Sensitivity | ≥100 copies |
| Display | 4.3″ Color Touchscreen |
| Internal Storage | SD Card |
| Connectivity | USB, Ethernet, Wi-Fi |
| Power Input | Max 350 W |
| Dimensions (W×D×H) | 340 × 350 × 410 mm |
| Weight | 18.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | AMR-Mini |
| Light Source | Dual high-stability LED (340–750 nm) |
| Detection Principle | Absorbance (Optical Density) |
| Standard Filters | 450/630 nm & 405/492 nm |
| Custom Filter Options | 340–750 nm (28 wavelengths available) |
| Detector | 9-photodiode array |
| Measurement Range | 0–4.0 Abs |
| Resolution | 0.001 Abs |
| Wavelength Accuracy | ≤ ±2 nm |
| Linearity | R² ≥ 0.995 (0.0–3.0 Abs) |
| Photometric Accuracy | ≤ ±(0.5% + 0.01 Abs) [0.0–2.0 Abs), ≤ ±(1.0% + 0.01 Abs) [2.0–3.0 Abs) |
| Precision (CV) | ≤ 0.5% [0–3.0 Abs) |
| Stability | ≤ 0.005 Abs [0.0–2.0 Abs) |
| Read Time | <15 s (single wavelength), <28 s (dual wavelength) for 96-well plate |
| Dimensions (W×D×H) | 135 × 225 × 89 mm |
| Weight | 2.0 kg |
| Power | USB-powered (12 V, 3 A) |
| Interface | 1 × USB-C, 1 × USB-A |
| Connectivity | Bluetooth 5.0, USB cable |
| Software | Cross-platform PC application (Windows 7/10 64-bit), bilingual UI (English/Chinese) |
| Optional Module | AMR-Mini T with integrated incubation (up to 45 °C) and orbital shaking (200–1,200 rpm) |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | FlexA-200 |
| Detection Principle | Absorbance (UV-Vis) |
| Wavelength Range | 200–1000 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Optical System | Grating-based monochromator with 1 nm step resolution |
| Read Range | 0–4.0 OD |
| Bandwidth | <2.5 nm |
| Photometric Accuracy @450 nm | ±(1.0% + 0.003 Abs) for 0–2.0 Abs |
| Photometric Precision @450 nm | CV < 0.5% (precise mode), CV < 1.0% (fast mode) |
| 96-well Plate Read Time | ~8 s (fast), <28 s (precise, endpoint) |
| Temperature Control Range | Ambient +4 °C to 45 °C |
| Temp. Uniformity & Accuracy | ±0.5 °C at 37 °C |
| Detector | Dual silicon photodiodes (sample + reference beam) |
| Display | 10-inch capacitive touchscreen (Android OS) |
| Onboard Storage | 16 GB (≥20,000 assay files) |
| Connectivity | 1× USB-B, 2× USB-A, 1× Ethernet |
| Dimensions (W×D×H) | 300 × 500 × 260 mm |
| Net Weight | 15.5 kg |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TSR-300 |
| Pricing | Upon Request |
| Light Source Wavelength | 525 ± 30 nm |
| Detection Element | Silicon Photocell |
| Sample Width Compatibility | 3–6 mm |
| Minimum Test Line Spacing | 3 mm |
| Detection Output | Qualitative, Semi-quantitative, and Quantitative |
| Data Storage | NAND Flash memory |
| Display | 7-inch high-resolution capacitive touchscreen |
| Interface | Dual USB-A ports, optional Ethernet port |
| Built-in Printer | Thermal mini-printer |
| Power Supply | DC 12–24 V, 2 A (grounded) |
| Power Consumption | ≤ 30 W |
| Dimensions (W × D × H) | 185 × 186 × 97 mm |
| Net Weight | 2.2 kg |
| Shipping Weight | 4.0 kg |
| Operating System | Linux + Qt framework |
| Analysis Algorithms | Linear, Logarithmic, Polynomial curve fitting |
| T/C Ratio CV | ≤1% (T/C > 0.2), ≤2% (T/C ≤ 0.2) |
| Stability CV | ≤3% (T/C > 0.2), ≤5% (T/C ≤ 0.2) |
| Scan Time | < 10 s per strip or cassette |
| Result Validation | Automatic invalid result rejection |
| Brand | Allsheng (Hangzhou) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SealBio-2 Semi-Automatic Microplate Sealer |
| Pricing | Upon Request |
| Heating Temperature Range | 80–200 °C (1.0 °C increment) |
| Temperature Accuracy | ±1.0 °C |
| Temperature Uniformity | ±1.0 °C |
| Sealing Time Range | 0.5–10.0 s (0.1 s increment) |
| Plate Height Detection | Automatic (9–48 mm) |
| Max. Power Input | 300 W |
| Dimensions (D×W×H) | 370 × 178 × 330 mm |
| Weight | 9.6 kg |
| Compatible Plate Materials | PP, PS, PE |
| Compatible Plate Types | Standard ELISA/cell culture plates, 96-well/384-well PCR plates (full-skirted, half-skirted, non-skirted), deep-well storage plates |
| Compatible Sealing Films | Polypropylene foil, PET-PP laminates, transparent polymer films, thin-gauge thermoplastic films, aluminum foil membranes |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Auto-NGS 200 NGS Library Preparation Workstation |
| Quotation | Available Upon Request |
| Dimensions (W×D×H) | 740 mm × 640 mm × 640 mm |
| Weight | 85 kg |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Sample Throughput | 1–96 samples per run |
| Plate Positions | 26 standard SBS-compliant positions |
| Pipetting System | 24-channel, 1–200 µL (capable of single-channel operation with pressure-capacitive liquid level detection) |
| Minimum Detectable Volume | 20 µL |
| Pipetting Accuracy | ≤±8% at 1 µL |
| Pipetting Precision | ≤±6% at 1 µL |
| Inter-well CV for Purification | ≤5% |
| Lysis/Binding Block Temperature Range | 10–110 °C (active rapid cooling) |
| Elution Block Temperature Range | 37–120 °C |
| Heating Rate (Lysis Block) | 25–110 °C in ≤5 min (from 25 °C ambient) |
| Cooling Rate (Lysis Block) | 110–25 °C in ≤7 min (from 25 °C ambient) |
| Temperature Uniformity | ±1 °C at 95 °C (lysis block) |
| Temperature Accuracy | ±1 °C at 95 °C (lysis block) |
| Integrated Fluorometer | 24-well, real-time concentration quantification |
| Integrated Thermal Module | PCR amplification and hybridization-compatible heating/mixing |
| Mixing Module | Au-Shaker — thermostatic vortex mixer with auto-clamping, 24 V DC, 120 W |
| Cooling Module | Au-Cooler — Peltier-based metal bath, 24 V DC, 160 W, CAN-enabled |
| Onboard Software | Android OS, 10-inch capacitive touchscreen, role-based user accounts, audit-trail-ready protocol editing, USB/LAN connectivity |
| Optional Vision System | For consumables recognition and position validation |
| Contamination Control | Built-in HEPA filtration + UV sterilization |
| Compatible Consumables | SBS-format plates, 8-tube strips, 96-well PCR plates (non-skirted), 60 mL reagent reservoirs, magnetic stands, tip boxes (<700 tips) |
Show next