Empowering Scientific Discovery

Harvard Bioscience

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEKA
OriginGermany
ModelEPC 10 USB 3.0
Detection PrincipleVoltage Clamp & Current Clamp
Instrument TypeFully Automated Electrophysiology Workstation
Cell TypesIsolated neurons, cardiomyocytes, and related cell lines
Seal QualityHigh
Success Rate>90%
Recording Channels1/2/4/8
Sampling RateUp to 2 MHz
ADC Channels5
DAC Channels3
Integrated Data AcquisitionLIH3.x Low-Noise Digitization Engine
Software PlatformPATCHMASTER NEXT & FITMASTER NEXT
ComplianceDesigned for GLP/GMP-aligned electrophysiology workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMulti Channel Systems
OriginGermany
ManufacturerMulti Channel Systems GmbH
ModelRoboocyte2
Detection PrincipleTwo-Electrode Voltage Clamp (TEVC)
Instrument TypeFully Automated High-Throughput Electrophysiology Platform
Cell TypeXenopus laevis oocytes
Seal Resistance>1 GΩ
Throughput Format96-well plate
Amplifier ArchitectureIntegrated High-Stability TEVC Amplifier
Liquid Handling CompatibilityRoboFlow or Gilson Pipetting Systems (Optional)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWarner Instruments
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelSmart USSING
Instrument TypeAutomated
Dimensions (W × D × H)380 mm × 75 mm × 20 mm
Temperature Control Range10 °C to 40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBiochrom
OriginUSA
ModelBioDrop 125
Detection Time2 s
Wavelength Accuracy±2 nm
BSA Detection Range0.1–134 mg/mL
DNA Detection Range1–12,000 ng/µL
Sample TypeNucleic Acids & Proteins
Sample Volume Requirement0.6–2 µL
Optical Path Length0.125 mm
Beam Height15 mm
CompatibilityUniversal with Standard UV-Vis Spectrophotometers
Cuvette TypeFixed-pathlength, Quartz-based Microvolume Cuvette
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBTX
OriginUSA
ModelBTX Hybrimune
Capacity Options2 mL (microscope-compatible transparent chamber) & 9 mL fusion chambers
AC Pre-Fusion Pulse0.2–2.0 MHz (0.2 MHz step), 5–75 V (0.1 V step), 0–60 s (1 s step), non-sinusoidal ramp-up waveform
AC Post-Fusion Pulsesame frequency/voltage range, ramp-down waveform
DC Fusion Pulsesquare wave, 100–1000 V (5 V step), 20–1000 µs (10 µs step), 0–10 pulses, 0.125–10 s inter-pulse interval
Cycles1–10 sets
Operating Temperature20–30 °C
ComplianceDesigned for GLP-compliant lab environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEKA
OriginGermany
ModelEPC 10 USB
InterfaceUSB 2.0
Operating SystemsWindows 7/10/11, macOS (via Pulse/TIDA compatibility layers), legacy Mac OS 9/X
CalibrationFully automated self-calibration & self-test
Capacitance CompensationFast/slow, series resistance, liquid junction potential — all software-controlled
Lock-in AmplifierIntegrated for membrane capacitance measurement (ΔCm)
Stimulus GeneratorProgrammable multi-segment waveform editor with sub-millisecond timing resolution
Data Acquisition16-bit ADC/DAC (ITC-1600 interface integrated via optical fiber)
BandwidthDC to 15 kHz (true low-noise performance up to 15 kHz)
Input Voltage Range±10 V
Current Range±1 nA to ±100 nA (12 gain settings)
Power Supply100–130 V AC or 200–260 V AC, 50/60 Hz
Probe ConfigurationsSingle-, dual-, triple-, and quad-patch headstage options available
Compliance StandardsCE-marked
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMulti Channel Systems
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelMEA2100-mini
Instrument TypeSingle-Well Format
Application ScopeIn Vitro Electrophysiological Recording & Stimulation
Electrode Pitch200 µm
Electrode Diameter30 µm
Electrode Layout8×8 (60 active + 4 ground/ reference electrodes, or 120-channel variant)
Physical Dimensions186 × 80 × 12 mm
Amplifier Resolution24-bit
Max Sampling Rate per Channel50 kHz
Stimulator ModesCurrent Source (±1 mA), Voltage Source (±10 V)
Signal Acquisition Units per MCS-IFB Interface BoardUp to 2
Probes per Acquisition UnitUp to 4
Integrated On-Probe ElectronicsAmplification, Stimulation, and ADC
Operating EnvironmentStandard CO₂ incubators (37 °C, 5% CO₂, humidified)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0